首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
On-site measurement of lead in workplace air filter samples and paint chip samples by ultrasonic extraction and anodic stripping voltammetry (UE-ASV) was evaluated in the field during renovation and remodeling activities in residences having leaded paint. Aerosol and paint samples were collected using standard techniques, and the samples were analyzed on-site for lead content by portable UE-ASV. Lead in sample extracts was subsequently determined by atomic absorption (AA) spectrometry in a fixed-site laboratory. The remaining sample extracts plus undissolved material (air filters or paint particles) were then subjected to hot plate digestion in concentrated nitric acid-30% hydrogen peroxide prior to AA analysis for lead. Field UE-ASV lead data were thereby compared to UE-AA and hot plate digestion-AA results from fixed-site laboratory lead measurement. Determination of lead in air filter samples by UE-ASV (over the range of 5 microg to approximately 800 microg Pb per sample) was extremely well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, a significant negative bias associated with ASV measurement was observed, and this was attributed to a matrix effect. Lead measurement in paint chip samples by UE-ASV (over the range of approximately 10 to approximately 550 microg Pb g(-1)) was well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, correlation and precision were lower for lead measurement in paint samples as compared to aerosol samples, and a negative bias was also observed. Lead measurements by UE-AA were compared to lead determinations by hot plate digestion-AA; these data were highly correlated and demonstrated no significant bias. Thus it was concluded that the ultrasonic extraction procedure performed equivalently to hot plate digestion. It was reasoned that matrix effects due to the preparation and analysis of paint chip particles resulted in greater imprecision as well as negative bias by ASV measurement. Despite significant negative bias in this sample set, UE-ASV offers promise for on-site measurement of lead in samples of interest in occupational and environmental health.  相似文献   

2.
Analytical methods for the determination of trace beryllium in soils are needed so that anthropogenic sources of this element can be distinguished from native (background) levels of beryllium. In this work, a collaborative interlaboratory evaluation of a new extraction and fluorescence-based procedure for determining beryllium in soil samples was carried out to fulfil method validation requirements for ASTM International voluntary consensus standard test methods. A Canadian reference material, CCRMP Till-1 soil, with a background beryllium concentration of 2.4 microg g(-1), was selected for study. This certified reference material (CRM) was spiked and homogenized with varying levels of beryllium oxide in order to give batches of material with beryllium concentrations of 4.36 +/- 0.69, 11.5 +/- 0.7, 124 +/- 7 and 246 +/- 16 microg g(-1) (+/- values are standard deviations). In the interlaboratory study (ILS), which was carried out in accordance with an applicable ASTM International standard practice (ASTM E691), samples of these spiked soils were subjected to extraction in dilute ammonium bifluoride at approximately 90 degrees C for 40 h. Fluorescence measurement of the extracted beryllium was carried out via detection using the high quantum yield fluorophore, hydroxybenzoquinoline sulfonate (HBQS). Interlaboratory precision estimates from six participating laboratories ranged from 0.048 to 0.103 (relative standard deviations) for the five different beryllium concentrations. Pooled bias estimates resulting from this ILS were between -0.049 and 0.177 for the various beryllium levels. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method.  相似文献   

3.
Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter(-1), with three different filter loadings denoted "Low", "Medium" and "High". Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter(-1). Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study.  相似文献   

4.
Beryllium is widely used in industry for its unique properties; however, occupational exposure to beryllium particles can cause potentially fatal disease. Consequently, exposure limits for beryllium particles in air and action levels on surfaces have been established to reduce exposure risks for workers. Field-portable monitoring methods for beryllium are desired in order to facilitate on-site measurement of beryllium in the workplace, so that immediate action can be taken to protect human health. In this work, a standardized, portable fluorescence method for the determination of trace beryllium in workplace samples, i.e., air filters and dust wipes, was validated through intra- and inter-laboratory testing. The procedure entails extraction of beryllium in 1% ammonium bifluoride (NH(4)HF(2), aqueous), followed by fluorescence measurement of the complex formed between beryllium ion and hydroxybenzoquinoline sulfonate (HBQS). The method detection limit was estimated to be less than 0.02 microg Be per air filter or wipe sample, with a dynamic range up to greater than 10 microg. The overall method accuracy was shown to satisfy the accuracy criterion (A< or = +/-25%) for analytical methods promulgated by the US National Institute for Occupational Safety and Health (NIOSH). Interferences from numerous metals tested (in >400-fold excess concentration compared to that of beryllium) were negligible or minimal. The procedure was shown to be effective for the dissolution and quantitative detection of beryllium extracted from refractory beryllium oxide particles. An American Society for Testing and Materials (ASTM) International voluntary consensus standard based on the methodology has recently been published.  相似文献   

5.
The purposes of this study are: (1) to determine whether proficiency analytical test (PAT) materials from the American Industrial Hygiene Association can be used to provide quality data for portable X-ray fluorescence analysis (XRF) of lead in dust wipe surface samples; (2) to provide data to determine whether the on-site analysis of field dust wipe samples by XRF and the laboratory method of inductively coupled plasma emission analysis (ICP) are comparable; and (3) to determine if differences exist between different wipe materials. Several wipes meet the ASTM E1792 performance requirements of lead background level less than 5 microg per wipe, be only one layer thick, yield recovery rates of 80- 120% from spiked samples, remain damp throughout the sampling procedure, and do not contain aloe. The wipes used in this study were Pace Wipes, which are used for the PAT materials, and, for the field samples, Palintest Wipes, which were supplied by the instrument manufacturer, and Ghost Wipes, which are popular because they digest in hot, concentrated acid, so that chemical analysis is simplified. Twenty PAT wipe samples were obtained from four different proficiency test rounds. Surface wipe samples were taken at three different locations representing different industry types. All samples were analyzed using a portable XRF spectrometer and by ICP. Strong linear relationships were found for the analysis of wipe samples by ICP and by portable XRF. For the PAT samples, the results from the ICP and XRF analysis were not statistically equivalent, which indicates a bias in the ICP analysis. The bias was not excessive, since all ICP analyses fell within the acceptable range for the proficiency samples. The good correlation between the proficiency sample reference values and the XRF determinations is not surprising considering similar proficiency samples were used to calibrate the instrument response. Users of this portable XRF analyzer could enroll in the proficiency test program as part of their quality assurance program. For field samples, the relationship was strongest for Palintest wipes, and the values found for all three industries could be combined. However, the results from the ICP and XRF analysis were not statistically equivalent using the correction factor in the calculation algorithm as supplied with the instrument, and a new coefficient was derived. The mean relative error for the XRF analysis versus the ICP analysis was greater than 25%, such that the method falls within the realm of screening procedures. For Ghost Wipe samples, the precision was different for different industries, and the results could not be pooled. Differences between the two wipe materials may be related to the number of folds required for analysis.  相似文献   

6.
ICP-AES法和分光光度法测定工业废水中总磷的方法比较   总被引:1,自引:0,他引:1  
用ICP-AES法和分光光度法同时测定4种不同工业废水中的总磷含量,将2种方法的测定结果作比对。试验表明,ICP-AES法对国家标准样品的测定结果具有较高的准确度和精密度,4种废水样品测定结果的加标回收率为94.0%~110%,RSD在0.9%~3.2%之间。分光光度法适用于低浓度、低干扰样品的测定,对于高浓度含磷废水,取样体积和样品稀释倍数均会对其测定结果产生显著影响。消解样品经浊度-色度补偿后,分光光度法的测定结果精密度较低。  相似文献   

7.
Control of workplace exposure to beryllium is a growing issue in the United States and other nations. As the health risks associated with low-level exposure to beryllium are better understood, the need increases for improved analytical techniques both in the laboratory and in the field. These techniques also require a greater degree of standardization to permit reliable comparison of data obtained from different locations and at different times. Analysis of low-level beryllium samples, in the form of air filters or surface wipes, is frequently required for workplace monitoring or to provide data to support decision-making on implementation of exposure controls. In the United States and the United Kingdom, the current permissible exposure level is 2 microg m(-3) (air) and the United States Department of Energy has implemented an action level of 0.2 microg m(-3) (air) and 0.2 microg/100 cm(2) (surface). These low-level samples present a number of analytical challenges, including (1) a lack of suitable standard reference materials, (2) unknown robustness of sample preparation techniques, (3) interferences during analysis, (4) sensitivity (sufficiently low detection limits), (5) specificity (beryllium speciation) and (6) data comparability among laboratories. Additionally, there is a need for portable, real-time (or near real-time) equipment for beryllium air monitoring and surface wipe analysis that is both laboratory-validated and field-validated in a manner that would be accepted by national and/or international standards organizations. This paper provides a review of the current analytical requirements for trace-level beryllium analysis for worker protection and also addresses issues that may change those requirements. The current analytical state of the art and relevant challenges facing the analytical community will be presented, followed by suggested criteria for real-time monitoring equipment. Recognizing and addressing these challenges will present opportunities for laboratories, research and development organizations, instrument manufacturers and others.  相似文献   

8.
对便携式催化氧化-FID法测定非甲烷总烃的检出限、精密度、准确度、催化效率等性能指标开展研究,考察该方法测定固定污染源废气中非甲烷总烃的适用性。结果表明:催化氧化装置的转化效率为98.1%~99.7%,方法检出限为0.05 mg/m3(以碳计);2个质量浓度水平的甲烷和丙烷混合标准气体测定结果的相对误差分别为-6.4%~6.1%、-4.7%~-0.5%,实验室内、实验室间测定结果的RSD分别为2.9%~5.9%和1.6%~2.5%、1.5%和0.6%。用该方法和国标法同时测定实际样品,两种方法测定结果的相对误差为6.4%~21.4%。  相似文献   

9.
Portable X-ray fluorescence (XRF) technology may provide faster turn-around without compromising accuracy when assessing personal exposures to metals such as lead, but it has only been tested in limited field environments. This study is part of a series, where various types of sampler are used to collect airborne lead in different environments for presentation to a portable XRF analyzer. In this case personal samples were taken at a manufacturer of solder alloys consisting mainly of lead and tin, using the closed-face 37 mm cassette (CFC), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. Following XRF analysis the samples were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP). The internal surfaces of CFC's and 25 mm open-face cassettes were also wiped, and the wipes analyzed for lead to assess wall-losses in these two samplers. Analysis of all elements present is useful to ascertain contributions to matrix interference effects. In addition to lead, other metals such as tin, copper, iron, silver, cadmium and antimony were also detected in some or all of the samples by ICP analysis, but only copper and iron could be determined using the XRF analyzer under test. After the removal of a few outliers, all five samplers gave good correlations (r(2) > 0.9) between the two analytical methods over the entire range of found lead mass, which encompassed both the action level and the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects, particularly from tin, which was the most common element after lead. The average of three XRF readings across filters from the GSP samplers gave the best results with 96.7% of results within +/-25% and 100% within +/-30% of the associated ICP values. Using the center reading only was almost as good with 90.0% of results within +/-25% and 96.7% within +/-30% of the associated ICP values, and results can be obtained faster with a single reading. The use of an algorithm developed by OSHA for three readings from the CFC filter samples gave the next best results with 93.3% of XRF results within +/-25% of the corresponding ICP values. However, analysis of wipes from the interior of the cassettes indicated a substantial loss of sample to the walls, and even larger wall-losses were encountered in the 25 mm open-face cassette. Neither this latter sampler nor the IOM or button sampler met the 95% criterion, even for +/-30% accuracy.  相似文献   

10.
建立了王水水浴消解-原子荧光法测定土壤中砷汞的方法,确定还原剂为硼氢化钾,测砷和汞时硼氢化钾的最优质量分数分别为2%和0.05%,载流为5%盐酸。该法砷和汞分别在质量浓度0.0~40.0μg/L和0.00~4.00μg/L范围内线性良好,相关系数均0.999 5,砷和汞的检出限分别为0.009和0.001 mg/kg,相对标准偏差分别为3.90%和2.67%,加标回收率分别为94.1%~107.6%和92.0%~104.0%。采用本法对国家标准土壤样品和东海县部分农田土壤样品进行测定分析,结果良好,表明该法操作简单、灵敏度高、实用性好,适用于土壤中砷和汞的测定。  相似文献   

11.
Occupational sampling and analysis for multiple elements is generally approached using various approved methods from authoritative government sources such as the National Institute for Occupational Safety and Health (NIOSH), the Occupational Safety and Health Administration (OSHA) and the Environmental Protection Agency (EPA), as well as consensus standards bodies such as ASTM International. The constituents of a sample can exist as unidentified compounds requiring sample preparation to be chosen appropriately, as in the case of beryllium in the form of beryllium oxide (BeO). An interlaboratory study was performed to collect analytical data from volunteer laboratories to examine the effectiveness of methods currently in use for preparation and analysis of samples containing calcined BeO powder. NIST SRM(?) 1877 high-fired BeO powder (1100 to 1200 °C calcining temperature; count median primary particle diameter 0.12 μm) was used to spike air filter media as a representative form of beryllium particulate matter present in workplace sampling that is known to be resistant to dissolution. The BeO powder standard reference material was gravimetrically prepared in a suspension and deposited onto 37 mm mixed cellulose ester air filters at five different levels between 0.5 μg and 25 μg of Be (as BeO). Sample sets consisting of five BeO-spiked filters (in duplicate) and two blank filters, for a total of twelve unique air filter samples per set, were submitted as blind samples to each of 27 participating laboratories. Participants were instructed to follow their current process for sample preparation and utilize their normal analytical methods for processing samples containing substances of this nature. Laboratories using more than one sample preparation and analysis method were provided with more than one sample set. Results from 34 data sets ultimately received from the 27 volunteer laboratories were subjected to applicable statistical analyses. The observed performance data show that sample preparations using nitric acid alone, or combinations of nitric and hydrochloric acids, are not effective for complete extraction of Be from the SRM 1877 refractory BeO particulate matter spiked on air filters; but that effective recovery can be achieved by using sample preparation procedures utilizing either sulfuric or hydrofluoric acid, or by using methodologies involving ammonium bifluoride with heating. Laboratories responsible for quantitative determination of Be in workplace samples that may contain high-fired BeO should use quality assurance schemes that include BeO-spiked sampling media, rather than solely media spiked with soluble Be compounds, and should ensure that methods capable of quantitative digestion of Be from the actual material present are used.  相似文献   

12.
A comprehensive clean-up method for quantitative analysis of polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples was developed. Since the chemical nature and toxicity of planar PCBs are similar to those of PCDD/Fs, dioxin-like PCBs and PCDD/Fs are often surveyed together in their exposure assessments. The development of a method for the simultaneous analysis of PCBs and PCDD/Fs in environmental samples is invaluable. The automated clean-up system evaluated in this work consists of three additional steps after traditional extraction: the chromatography on gel permeation (GPC), the concentration of the solvent through the use of an in-line evaporation module and the further purification and separation of PCDDs/Fs and dl-PCBs on an alumina cartridge in the 'SPE module'. In this work, three fly ash samples from an interlaboratory study with different PCDD/F and PCB levels were Soxhlet-extracted and then cleaned up using an automated system. PCDD/Fs and PCBs were determined using isotope dilution and high resolution gas chromatography/high resolution mass spectrometry. The determined values of 17 PCDD/Fs were consistent with the certified values and the relative standard deviations (RSDs) of the determined values were less than 20%. The recoveries of (13)C labeled PCDD/Fs and planar PCBs, and their RSDs were within the ranges specified in EPA1613 and 1668a methods, respectively. An accurate and reliable method was successfully developed and can be used in the simultaneous analysis of PCDD/Fs and planar PCBs in environmental samples.  相似文献   

13.
Extending wipe sampling methodologies to elements other than lead   总被引:1,自引:0,他引:1  
Wipe sampling is the USA regulatory protocol for determination of "dust lead loadings" in residential environments. Few studies have applied the wipe sampling method to metals other than lead (Pb) for the purpose of residential exposure assessments. This study was undertaken to develop and expand the wipe method for quantifying additional metal(loid)s including arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), and antimony (Sb); and to provide information on typical background loadings for these metals in urban Canadian homes. A total of 932 wipe samples, 220 field blanks, and 220 duplicate wipes were collected from 222 homes located in three cities in Ontario, Canada using the ASTM 1728 standard. The wipes were digested using a modified version of the ASTM 1644 standard for Pb, which prescribes a hot nitric acid/hydrogen peroxide digestion. The key modification was the addition of hydrofluoric acid to improve recoveries of the target elements, and determination using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Generally, a large proportion of the results fell below the limits of detection (LOD) and quantification (LOQ). To distinguish "elevated" metal loadings from loadings characterized as "urban background", an upper background threshold for each element was derived using a normality (Q-Q) plot. LOQ was determined to be the appropriate minimum threshold based on quality assurance criteria. It is concluded that wipes are a useful sampling option to investigate multi-element loadings in residential environments.  相似文献   

14.
An effective and sensitive method for simultaneous analysis of malachite green (MG), enrofloxacin (ENFLX) and ciprofloxacin (CPFLX) by liquid chromatography-diode array detection with solid-phase extraction (SPE) is developed. The conditions of SPE and LC were investigated and optimised. The effective separation of these compounds was achieved using a ZY1104 C18 column (250 × 4.6 mm, 5 μm) with 20 mM tetrabutyl ammonium bromide (pH 3.0)-acetonitrile as mobile phase and gradient elution. The diode array detection was used at 278 nm for ENFLX and CPFLX and at 613 nm for MG. Under the optimal conditions, the method LOD values of MG, ENFLX and CPFLX were 0.01, 0.07 and 0.10 μg L(?-1) for fish farming water samples and 1.5, 10.5 and 15 μg kg(?-1) for fish feed samples, respectively. The relative recoveries of the three analytes were achieved to be 76.7-82.3% with the RSDs (n = 5) of 3.2-4.6% for spiked fish farming water samples and 78.8-93.7% with the RSDs (n = 5) of 3.1-4.8% for spiked fish feed samples.  相似文献   

15.
改进的还原偶氮光度法同时快速测定水中硝基苯和苯胺   总被引:1,自引:1,他引:0  
对测定方法进行了改进,建立了用还原-偶氮分光光度法同时快速测定水中硝基苯和苯胺的分析方法。根据实验原理,对样品前处理装置进行了改进,实验步骤得到了简化,避免了样品溶液过滤转移过程造成样品损失,使样品前处理实验效率提高了90%以上;改进后的测定方法不仅可快速测定样品中硝基苯,还可同时测定样品中苯胺;达到了用一种分析方法同时测定样品中两种污染物的目的。方法精密度测定结果,相对标准偏差(n=6,RSD)为1.9%~3.2%;对硝基苯、苯胺混合标准样品以及实际废水样品进行了测定,并与原测定方法及苯胺国标测定方法进行了比对实验;测定结果具有一致性。加标实验回收率为96%~101%,表明方法准确可靠,可用于水和废水中硝基苯或硝基苯和苯胺的同时测定。  相似文献   

16.
Trichloroacetic acid (TCA) and dichloroacetic acid (DCA) are possible minor atmospheric degradation products of perchloroethylene and trichloroethylene, respectively. These acids may be wet- or dry-deposited from the atmosphere to land surfaces and hence possibly affect plant growth. However, the existing database on TCA levels in soil is limited to a few studies carried out in the late 1980's and the early to mid-1990's and it was concluded that there is a need for further measurements of concentrations of TCA and DCA in soils. In this study soil samples from 10 locations in 5 European countries, as well as vegetation samples, and a limited number of rainwater and air samples were collected and analysed for DCA and TCA to determine the concentrations of these compounds. An isotope dilution method using GC-MS was used for the determination of these acids in the samples. The method was briefly validated and the performance characteristics are presented. The results of the analysis of the soil samples show that the DCA and TCA concentrations in soil from different sites in Europe are more or less comparable, with the exception of Germany, especially Freudenstadt, where significantly higher TCA concentrations (up to 12 microg kg(-1) dw) were found. The average DCA and TCA concentrations in soil in this study were 0.25 +/- 0.12 and 0.64 +/- 1.40 microg kg(-1) dw, respectively. Generally, the concentration in soils from forest areas are about twice those from open-land areas. The DCA and TCA concentrations in vegetation samples ranged from 2.1 to 73 microg kg(-1) dw for DCA and from 4.7 to 17 microg kg(-1) dw for TCA. Thus, the concentrations in vegetation samples are 10-20 times higher than the soil concentrations. DCA and TCA concentrations in wet deposition samples and air samples collected in The Netherlands were 0.14 and 0.15 microg l(-1) for wet deposition samples and <0.5 and 0.7 ng m(-3) for air samples respectively. For these samples taken in The Netherlands, the estimated values for soil and air concentrations calculated from the wet deposition concentrations are in agreement with the concentrations measured in this study.  相似文献   

17.
土壤重金属监测过程及其质量控制   总被引:12,自引:8,他引:4  
重点探讨了土壤中典型重金属含量监测过程中样品制备、含水率、预处理等因素对分析结果的影响。实验结果表明,充分风干土壤的含水率在2%~3%左右,200目土壤颗粒度可满足分析精度的要求。硝酸-氢氟酸-高氯酸的多元混酸消解体系可实现对土壤重金属的充分溶解,对标准土壤样品中各元素的回收率可达84%~98%。批次内平行样品以及批次间质控样品各元素的相对标准偏差大都小于10%,符合《土壤环境监测技术规范》的要求,表明该研究建立的系统土壤重金属检测方法结果准确可靠。  相似文献   

18.
气相色谱法测定土壤中五氯酚   总被引:2,自引:0,他引:2  
采用索氏提取-气相色谱法测定土壤中的五氯酚,优化了试验条件。方法在0wg/kg-200wg/kg范围内线性良好,检出限为0.03μg/kg,空白土壤加标样测定的RSD为2.6%,回收率为95.4%~101%。  相似文献   

19.
An analytical method to determine a selection of 27 frequently prescribed and consumed pharmaceuticals in biosolid enriched soils and digested sludges is presented. Using a combination of pressurized liquid extraction, solid phase extraction and liquid chromatography with tandem mass spectrometry, it was possible to detect all analytes in each sample type at the low-sub ng g(-1) level. Solid phase extraction efficiencies were compared for 6 different sorbent types and it was found that Waters Oasis HLB cartridges offered enhanced selectivities with 20 analytes showing final method recoveries > or =60% in both soils and digested sludges. The method was validated for linearity, range, precision and limits of detection in both sample matrices. All analytes were then determined in sludge enriched soils as well as the precursor thermally dried sludge fertilizer produced from a primary wastewater treatment plant. Levels of the antibacterial agent triclosan were found to exceed 20 microg g(-1) in digested sludge and 5 microg g(-1) in thermally dried sludge cake. Significant traces of carbamazepine and warfarin were also detected in the above samples.  相似文献   

20.
The aims of this study were to determine the contents of cadmium (Cd), copper (Cu), lead (Pb), zinc (Zn), aluminium (Al), and iron (Fe) (aqua regia-extractable) in 27 soil plots (54 samples) from Manresa, NE Spain, and to establish relationships between heavy metals and some soil properties. The main soil types were surveyed and the median concentrations (mg kg(-1)) obtained were Cd 0.28, Cu 20.3, Pb 18.6, Zn 67.4, Al 22,572, and Fe 21,551. Element concentrations for these soils were lower than the published values for the Valencia region (Spain) and Torrelles and Sant Climent municipal districts (Catalonia, Spain). In terms of soil properties, the results of this study suggest that, in Manresa soils, both trace element adsorption and retention are influenced by several properties such as clay minerals, carbonates, organic matter, and pH. All element contents were positively correlated with clay content. Pb and Zn were negatively correlated with pH and CaCO(3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号