首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A GC-MS method for the quantification of bacterial lipopolysaccharides (LPS, endotoxin) is presented. After hydrolytic cleavage of 3-hydroxy fatty acids (3-OH FAs) from the lipid A region of LPS, derivatisation of both the hydroxyl and the carboxyl group was performed in one step with a mixture of methyl-bis(trifluoracetamide)(MBTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoracetamide (MTBSTFA). Using GC-MS in the EI mode with selected ion monitoring (SIM) for analysis, baseline separation of 3-OH FAs (and of possibly interfering 2-OH FAs) was achieved. The sensitivity of the method (LOD 7-50 pg/injection for the different 3-OH FAs investigated) allows for the efficient quantification of LPS in occupational and environmental samples. Degradation of 3-OH FAs as well as of their derivatives during sample preparation and GC-MS separation as a possible source of errors in analytical methods based on 3-OH FA determination is reported for the first time. Thermal elimination of water from the underivatised 3-OH FAs and of trifluoroacetic acid from the derivatives was identified as the cause of degradation. The resulting alpha,beta-unsaturated compounds showing the same mass spectra as the 3-OH FA derivatives were detected as more or less prominent satellite peaks. By using alkaline instead of acidic hydrolysis and cool on-column instead of split/splitless injection, elimination was reduced to an acceptable level.  相似文献   

2.
Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and assay media, to endotoxin estimates previously obtained by Limulus amebocyte lysate (LAL) assay and amounts of 3-hydroxy fatty acids (3-OHFA) in lipopolysaccharide (LPS) using gas-chromatography mass spectroscopy (GC-MS). We found that lot-to-lot variability of the rFC assay kits does not significantly alter endotoxin estimates in house dust samples when performed using three of the four assay media tested and that choice of assay media significantly altered endotoxin estimates obtained by rFC assay of house dust samples. Our findings demonstrate lot-to-lot reproducibility of rFC assay of environmental samples and suggest that use of rFC assay performed with Tris buffer or water as the extraction and assay medium for measurement of endotoxin in dust samples may be a suitable choice for developing a standardized methodology.  相似文献   

3.
Muramic acid (MA) is a unique amino sugar that is a constituent of the peptidoglycan (PG) present in prokaryotic cell walls. MA can serve as a marker for quantifying bacterial load, e.g. in indoor environments, by using gas chromatography-tandem mass spectrometry (GC-MS-MS). We demonstrated recently that the methyl ester O-methyl acetate (MMA) derivative can be used to detect MA in house dust by ion-trap GC-MS-MS. However, since the MMA derivative is not formed from free MA quantification was not optimal. Here we report 1) significant improvements in sample preparation of the MMA derivative and 2) an evaluation of the performance of derivative, using for comparison the alditol acetate derivative, the gold standard in quantitative trace analysis of MA in complex matrices. The MMA derivative was analysed using an MS instrument with internal ionization and the alditol acetate derivative was analysed using an instrument with external ionization. 13C-labelled cyanobacteria, containing MA in their PG, were used as the internal standard. A linear relationship was found between the two methods in studies on 27 parallel samples of airborne dust from school classes collected on filters. Although the analytical sensitivity of the MMA derivatives was somewhat slightly lower than of the alditol acetate derivative, this may be due to differences in yield of derivative, sample clean-up efficiency, or different performance of the GC columns or MS instruments. However preparation of the MMA derivative is quick and compatible with preparation of methyl esters of 3-hydroxy fatty acids (used as markers of Gram negative endotoxin) allowing the levels of both markers to be determined in the same dust sample. In conclusion, the MMA procedure can be used to determine MA in environmental samples with good reproducibility provided the concentration of the 13C-labelled MA internal standard in the cyanobacteria is first determined with an alternative method.  相似文献   

4.
Our group previously demonstrated that carbon dioxide (CO2) levels in heavily occupied schools correlate with the levels of airborne bacterial markers. Since CO2 is derived from the room occupants, it was hypothesized that in schools, bacterial markers may be primarily increased in indoor air because of the presence of children; directly from skin microflora or indirectly, by stirring up dust from carpets and other sources. The purpose of this project was to test the hypothesis. Muramic acid (Mur) is found in almost all bacteria whereas 3-hydroxy fatty acids (3-OH FAs) are found only in Gram-negative bacteria. Thus Mur and 3-OH FA serve as markers to assess bacterial levels in indoor air (pmol m(-3)). In our previous school studies, airborne dust was collected only from occupied rooms. However, in the present study, additional dust samples were collected from the same rooms each weekend when unoccupied. Samples were also collected from outside air. The levels of dust, Mur and C10:0, C12:0, C14:0, and C16:0 3-OH FAs were each much higher (range 5-50 fold) in occupied rooms than in unoccupied school rooms. Levels in outdoor air were much lower than that of indoor air from occupied classrooms and higher than the levels in the same rooms when unoccupied. The mean CO2 concentrations were around 420 parts per million (ppm) in unoccupied rooms and outside air; and they ranged from 1017 to 1736 ppm in occupied rooms, regularly exceeding 800-1000 ppm, which are the maximum levels indicative of adequate indoor ventilation. This indicates that the children were responsible for the increased levels of bacterial markers. However, the concentration of Mur in dust was also 6 fold higher in occupied rooms (115.5 versus 18.2 pmole mg(-1)). This further suggests that airborne dust present in occupied and unoccupied rooms is quite distinct. In conclusion in unoccupied rooms, the dust was of environmental origin but the children were the primary source in occupied rooms.  相似文献   

5.
Endotoxin exposure is associated with wheeze and asthma morbidity, while early life exposure may reduce risk of allergy and asthma. Unfortunately, it is difficult to compare endotoxin results from different laboratories and environments. We undertook this study to determine if lipopolysaccharide (LPS) extraction efficiency could account for differences among laboratories. We generated and collected aerosols from chicken and swine barns, and corn processing. We randomly allocated side-by-side filter samples to five laboratories for Limulus assay of endotoxin. Lyophilized aliquots of filter extracts were analyzed for 3-hydroxy fatty acids (3-OHFAs) as a marker of LPS using gas chromatography-mass spectrometry. There were significant differences in endotoxin assay and GC-MS (LPS) results between laboratories for all dust types (p < 0.01). Patterns of differences between labs varied by dust type. Relationships between assay and GC/MS results also depended on dust type. The percentages of individual 3-OHFA chain lengths varied across labs (p < 0.0001) suggesting that each lab recovered a different fraction of the LPS available. The presence of large amounts of particle associated LPS and absence of a freezing thawing cycle were associated with lower correlations between LPS and bioactivity, consistent with an absence of Limulus response to cell-bound endotoxin. These data suggest that extraction methods affect endotoxin measurements. The LAL methods may be most suitable when comparing exposures within similar environments; GC-MS offers additional information helpful in optimizing sample treatment and extraction. GC-MS may be of use when comparing across heterogeneous environments and should be considered for inclusion in future studies of human health outcomes.  相似文献   

6.
Muramic acid (Mur) is found in bacterial peptidoglycan (PG) whereas 3-hydroxy fatty acids (3-OH FAs) are found in Gram-negative bacterial lipopolysaccharide (LPS). Thus Mur and 3-OH FAs serve as markers to assess bacterial levels in indoor air. An initial survey, in a school, demonstrated that the levels of dust, PG and LPS (pmol m(-3)) were each much higher in occupied rooms than in the same rooms when unoccupied. In each instance, the Mur content of dust was increased and the hydroxy fatty acid distribution changed similarly suggesting an alteration in the bacterial population. Here, findings are compared with results from two additional schools. Follow-up aerosol monitoring by particle size was also performed for the first time for all 3 schools. The particle size distribution was shown to be quite different in occupied versus unoccupied schoolrooms. Within individual classrooms, concentrations of airborne particles [greater-than-or-equal]0.8 [micro sign]m in diameter, and CO(2) were correlated. This suggests that the increased levels of larger particles are responsible for elevation of bacterial markers during occupation. Release of culturable and non-culturable bacteria or bacterial aggregates from children (e.g. from flaking skin) might explain this phenomenon.  相似文献   

7.
Elevated concentrations of endotoxin in indoor air due to cigarette smoking   总被引:1,自引:0,他引:1  
Exposure to environmental tobacco smoke (ETS) is an important worldwide public health issue. The present study demonstrates that cigarette smoke can be a major source of endotoxin (lipopolysaccharide, LPS) in indoor environments. Gas-chromatography/mass-spectrometry was used to determine 3-hydroxy fatty acids as markers of endotoxin in air-borne house dust in homes of smokers and non-smokers. Air concentrations of endotoxin were 4-63 times higher in rooms of smoking students than in identical rooms of non-smoking students. The fact that cigarette smoke contains large amounts of endotoxin may partly explain the high prevalence of respiratory disorders among smokers and may also draw attention to a hitherto neglected risk factor of ETS.  相似文献   

8.
Studies on personal dust and endotoxin concentrations among animal farmers have been either small or limited to a few sectors in their investigations. The present study aimed to provide comparable information on the levels and variability of exposure to personal dust and endotoxin in different types of animal farmers. 507 personal inhalable dust samples were collected from 327 farmers employed in 54 pig, 26 dairy, 3 poultry, and 3 mink farms in Denmark. Measurements in pig and dairy farmers were full-shift and performed during summer and winter, while poultry and mink farmers were monitored during 4 well-defined production stages. The collected samples were measured for dust gravimetrically and analyzed for endotoxin by the Limulus amebocyte lysate assay. Simple statistics and random-effect analysis were used to describe the levels and the variability in measured dust and endotoxin exposure concentrations. Measured inhalable dust levels had an overall geometric mean of 2.5 mg m(-3) (range 相似文献   

9.
10.
A method using GC-MS and derivatization with N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) was developed for the analysis of 20 phenolic compounds in atmospheric samples (gas and particles). Air sampling was carried out using a Hi-Vol sampler with glass fibre filter and XAD-2 resin at a flow rate of 60 m(3) h(-1). The particle and gas phases were collected separately over a period of 4 h. Samples were Soxhlet extracted, evaporated to dryness under nitrogen and refilled with acetonitrile. 100 microl of these extracts were derivatized with 100 microl of MTBSTFA at 80 degrees C for 1 h under strong stirring. Phenolic compounds were injected into a GC-MS in splitless mode and quantified as their TBDMS derivatives in the SIM mode. Mass spectral analysis of the derivatives of the 20 compounds studied indicates that the spectra are highly specific showing an ion at [M - 57]+ which is useful for structure confirmation or analysis at low levels using selected ion monitoring. Quantification limits varied between 5 microg l(-1) and 10 microg l(-1) which correspond to 20 pg m(-3) and 40 pg m(-3) for 250 m(3) of air sampled. This method was successfully applied to atmospheric samples.  相似文献   

11.
Symptoms such as shortness of breath and cough have been noted in woodworking facilities even where wood dust itself is well-controlled. Suspicion has fallen on other possible contaminants in the workplace atmosphere, including bacterial endotoxin. A few studies have indicated potentially high endotoxin exposure with exposure to fresh wood in sawmills and in the production of fiberboard and chipboard, but fewer studies have been carried out on exposure to endotoxin in dry wood work, for example in joineries. A study of the endotoxin content of airborne wood dust samples from US woodworking facilities is presented, from the re-analysis of samples which previously had been taken to establish mass collection relationships between the IOM sampler, the closed-face 37 mm plastic cassette (CFC) sampler and the Button sampler. Endotoxin was strongly correlated with total dust, but the endotoxin content of a few fresh wood samples was found to be up to ten times higher per unit of wood dust than for dried-wood samples, and this difference was significant. No long-term time-weighted average sample exceeded the recommended limit value of 50 EU m(-3) (EU, endotoxin units)used in the Netherlands, although a number of the IOM samples came close (seven samples or 44% exceeded 20 EU m(-3)) and one short-term (48 minute) sample registered a high value of 73 EU m(-3). The geometric mean concentration from the IOM samples (11 EU m(-3)) is within the range of geometric means found from Australian joineries (3.7-60, combined: 24 EU m(-3)). In contrast, the corresponding values from the CFC (3.6 EU m(-3)), and the Button sampler (2.1 EU m(-3)) were much lower and no samples exceeded 20 EU m(-3). Endotoxin is likely only to be a significant problem in working with dried woods when associated with very high dust levels, where the wood dust itself is likely to be a cause for concern. The results from the few samples in this study where fresh wood was being worked were similar to results from other studies involving fresh woods. The agreement between these studies is encouraging given the difficulties of endotoxin analysis and the wide variation often expected between different laboratories.  相似文献   

12.
Presence of Stachybotrys chartarum in indoor environments has been linked to building-associated disease, however, the causative agents are unknown. Verrucarol (VER) and trichodermol (TRID) are hydrolysis products of some major S. chartarum mycotoxins, i.e. macrocyclic trichothecenes and trichodermin. We optimized gas chromatography-mass spectrometry (GC-MS) methods for detecting VER and TRID in S. chartarum-contaminated indoor environmental samples. Heptafluorobutyryl derivatives of both VER and TRID exhibited little MS fragmentation and gave much higher detection sensitivity (sub-picogram injected onto the GC column), both in GC-MS and GC-MSMS, than trimethylsilyl derivatives. Optimal detection sensitivity and specificity was achieved by combining chemical ionization and negative ion (NICI) detection with MSMS. With this method, VER and TRID were detected in building materials colonized by S. chartarum and TRID was demonstrated in dust settled in the breathing zone in a house where an inner wall was colonized. In summary, we have shown that NICI-GC-MSMS can be used to demonstrate mycotoxins in house dust in S. chartarum-contaminated dwellings.  相似文献   

13.
The aim of this study was to assess the associations between airborne and dustborne microbial contaminants (endotoxin and β-D-glucan) and estimate the effects of home characteristics on exposure levels of these microbial contaminants. Endotoxin and β-D-glucan concentrations in airborne inhalable particles, airborne PM1 (<1 μm) and vacuumed dust from 184 residential homes were determined using specific Limulus amebocyte assays. Home characteristics were recorded by visual inspection and questionnaires. Linear regression and correlation analyses were performed. Inhalable endotoxin correlated with dust endotoxin (r = 0.34, p < 0.001) and PM1 endotoxin (r = 0.33, p < 0.001). Inhalable β-D-glucan correlated with dust β-D-glucan (r = 0.18, p < 0.01), but not with PM1 β-D-glucan. Significant correlation was also found between PM1 and dust concentrations for endotoxin (r = 0.26, p < 0.001), but not for β-D-glucan. Multivariate regression analyses showed only one significant association between airborne contaminants and environmental characteristics: inhalable β-D-glucan was positively associated with relative humidity with an effect size (change in the dependent variable corresponding to a unit increase in the independent variable) of 2.32 and p < 0.05. In contrast, several associations were found between dust concentrations and environmental characteristics. Dust endotoxin was positively associated with temperature (2.87, p < 0.01) and number of inhabitants (2.76, p < 0.01), whereas dust β-D-glucan was inversely associated with the presence of dogs (-2.24, p < 0.05) and carpet (-3.05, p < 0.01) in the home. In conclusion, dustborne contaminants were more strongly affected by home characteristics than airborne contaminants. Furthermore, even though statistically significant, the correlations between airborne and dustborne contaminants were weak. This indicates that airborne concentrations cannot be reliably predicted based on dustborne concentrations.  相似文献   

14.
Endotoxin is a toxic, pro-inflammatory compound that has been detected in indoor air and dust in homes and occupational settings, and also in outdoor air. Data on the outdoor sampling of endotoxin are limited. Currently, little is known about the seasonal variation and influence of temperature on outdoor endotoxin levels. In the present study, we report endotoxin levels in fine fraction particulate matter with a 50% aerodynamic cutoff diameter of 2.5 microm (PM2.5) and describe the seasonal variation of endotoxin in Munich, Germany. In 1999-2000, PM2.5 was collected at forty outdoor monitoring sites across Munich. Approximately four samples were collected at each site for a total of 158 samples. Endotoxin concentrations in the PM2.5 samples were determined using the kinetic chromogenic Limulus Amebocyte Lysate (LAL) assay. The geometric mean endotoxin concentration was 1.07 EU mg PM2.5(-1) (95% C.I.: 0.915-1.251) or 0.015 EU m(-3) of sampled air (95% C.I.: 0.013-0.018). Munich endotoxin levels were significantly related to ambient temperature (p < 0.0001) and percent relative humidity (p < 0.0001). Sampling periods with higher average temperatures yielded higher levels of endotoxin in PM2.5 (r = 0.641), whereas decreases in percent relative humidity were associated with increased endotoxin levels in PM2.5 (r = -0.388). Endotoxin levels were significantly higher during the warmer seasons of spring [means ratio (MR): 2.5-2.7] and summer (MR: 2.1-3.0) than during winter. Although temperature and relative humidity do not explain all of the variability in endotoxin levels, their effects were significant in our data set. Temperature effects and seasonal variation of endotoxin should be considered in future studies of outdoor endotoxin.  相似文献   

15.
Advances in polymerase chain reaction (PCR) have permitted accurate, rapid and quantitative identification of microorganisms in pure cultures regardless of viability or culturability. In this study, a simple sample processing method was investigated for rapid identification and quantification of fungal spores from dust samples using both conventional and real-time PCR. The proposed method was evaluated for susceptibility to interference from environmental dust samples. Stachybotrys chartarum and Aspergillus fumigatus were used as test organisms. The sensitivity of detection in pure culture was 0.1 spore DNA equivalents per PCR reaction corresponding to 20 spores ml(-1) in the sample. However, 1 spore DNA equivalent per PCR reaction corresponding to 200 spores ml(-1) in the sample was the lowest amount of spores tested without interference in dust samples spiked with spores of either fungal species. The extent of inhibition was calculated using conventional and real-time PCR reactions containing fungal spores, specific primers, specific probes (for real-time PCR) and various amounts of dust. The results indicate that the extent of inhibition by dust on PCR varies with the type and amount of dust, and number of spores. No interference in the analysis of spiked samples was detected from 0.2 mg ml(-1) of four real-life dust samples at p-value >0.05 using 2 x 10(4) spores for conventional PCR and 2 x 10(5) spores for real-time PCR. However, samples containing >0.2 mg ml(-1) real-life dust compromised the PCR assay. These results suggest the potential usefulness of a simple sample processing method in conjunction with PCR for monitoring the fungal content of aerosols collected from indoor environments.  相似文献   

16.
The United States National Institute for Occupational Safety and Health, through an informal partnership with industry, labor, and the United States Mine Safety and Health Administration, has developed and tested a new instrument known as the Personal Dust Monitor (PDM). The new dust monitor is an integral part of the cap lamp that coal miners normally carry to work and provides continuous information about the concentration of respirable coal mine dust within the breathing zone of that individual. Previous laboratory testing demonstrated that there is a 95% confidence that greater than 95% of individual PDM measurements fall within +/-25% of reference measurements. The work presented in this paper focuses on the relationship between the PDM and respirable dust concentrations currently measured by a coal mine dust personal sampler unit utilizing a 10 mm Dorr-Oliver nylon cyclone. The United Kingdom Mining Research Establishment instrument, used as the basis for coal mine respirable dust standards, had been designed specifically to match the United Kingdom British Medical Research Council (BMRC) criterion. The personal sampler is used with a 1.38 multiplier to convert readings to the BMRC criterion. A stratified random sampling design incorporating a proportionate allocation strategy was used to select a sample of mechanized mining units representative of all US underground coal mines. A sample of 180 mechanized mining units was chosen, representing approximately 20% of the mechanized mining units in production at the time the sample was selected. A total of 129 valid PDM/personal sampler dust sample sets were obtained. A weighted linear regression analysis of this data base shows that, in comparison with the personal sampler, the PDM requires a mass equivalency conversion multiplier of 1.05 [95% C.I.=(1.03, 1.08)] when the small intercept term is removed from the analysis. Removal of the intercept term results in a personal sampler-equivalent concentration increase of 2.9% at a PDM measurement of 2.0 mg m(-3).  相似文献   

17.
北京市大气PM10源解析研究   总被引:10,自引:5,他引:10  
于2004年在北京市定陵、车公庄、古城、亦庄、房山和奥体中心6个采样点采集大气PM10环境样品,针对北京市颗粒物主要排放源采集土壤尘、建筑水泥尘、燃煤等污染源PM10样品,分别对其中的无机元素、离子、有机碳(OC)和元素碳(EC)进行测定。采用代表北京市颗粒物主要排放源PM10组分特征的成分谱,利用CMB受体模型对PM10来源进行解析。结果表明,PM10的最大来源为土壤尘,其它贡献源类依次为燃煤排放、机动车/燃油排放、二次粒子(SO42-、NO3-和NH4 )、建筑水泥尘。污染源贡献具有明显的季节变化,并存在一定的地域变化。  相似文献   

18.
Miners face a variety of respiratory hazards while on the job, including exposure to silica dust which can lead to silicosis, a potentially fatal lung disease. Currently, field-collected filter samples of silica are sent for laboratory analysis and the results take weeks to be reported. Since the mining workplace is constantly moving into new and often different geological strata with changing silica levels, more timely data on silica levels in mining workplaces could help reduce exposures. Improvements in infrared (IR) spectroscopy open the prospect for end-of-shift silica measurements at mine sites. Two field-portable IR spectrometers were evaluated for their ability to quantify the mass of silica on filter samples loaded with known amounts of either silica or silica-bearing coal dust (silica content ranging from 10-200 μg/filter). Analyses included a scheme to correct for the presence of kaolin, which is a confounder for IR analysis of silica. IR measurements of the samples were compared to parallel measurements derived using the laboratory-based U.S. Mine Safety and Health Administration P7 analytical method. Linear correlations between Fourier transform infrared (FTIR) and P7 data yielded slopes in the range of 0.90-0.97 with minimal bias. Data from a variable filter array spectrometer did not correlate as well, mainly due to poor wavelength resolution compared to the FTIR instrument. This work has shown that FTIR spectrometry has the potential to reasonably estimate the silica exposure of miners if employed in an end-of-shift method.  相似文献   

19.
In this study, air samples were taken using a BioSampler and gelatin filters from six sites in Beijing: office, hospital, student dormitory, train station, subway, and a commercial street. Dust samples were also collected using a surface sampler from the same environments. Limulus amoebocyte lysate (LAL) and Glucatell assays were used to quantify sample endotoxin and (1,3)- ${\rm{\beta}} $ -d-glucan concentration levels, respectively. Enzyme-linked immunosorbent assay (ELISA) was used to measure the dust mite allergens (Der p 1 and Der f 1). Ultrafine particle and lead concentrations in these sampling sites were also measured using P-Trak and atomic absorption spectrometer, respectively. Analysis of variance (ANOVA) and linear regression analysis were used to analyze the concentration data. Higher culturable bacteria (12,639 CFU/m3) and fungi (1,806 CFU/m3) concentrations were observed for the train station and the subway system, respectively. For the rest of sampling sites, their concentrations were comparable to those found in western countries, ranging from 990 to 2,276 CFU/m3 for bacteria, and from 119 to 269 CFU/m3 for fungi. ANOVA analysis indicated that there were statistically significant differences between the culturable bacterial and fungal concentration levels obtained for different sites (p value = 0.0001 and 0.0047). As for dust allergens, endotoxin, and (1,3)-β -d-glucan, their concentrations also seemed to be comparable to those found in the developed countries. Airborne allergen concentrations ranged from 16 to 68 ng/m3. The dust-borne allergen concentration was observed to range from 0.063 to 0.327 ng/mg. As for endotoxin, the highest airborne concentration of 25.24 ng/m3 was observed for the commercial street, and others ranged from 0.0427 to 0.1259 ng/m3. And dust-borne endotoxin concentration ranged from 58.83 to 6,427.4 ng/mg. For (1,3)-β -d-glucan, the airborne concentration ranged from 0.02 to 1.2 ng/m3. Linear regression analyses showed that there existed poor correlations between those in airborne and dust-borne states (R2?=?0.002~0.43). In our study, the lowest ultrafine particle concentration about 5,203 pt/cm3 was observed in office and the highest was observed at the train station, up to 32,783 pt/cm3. Lead concentration was shown to range from 80 to 170 ng/mg with the highest also observed at the train station. The information provided in this work can be used to learn the general situation of relevant health risks in Beijing. And the results here suggested that when characterizing exposure both airborne and dust-borne as well as the environments should be considered.  相似文献   

20.
建立了以液-液萃取、三重串联四极杆气相质谱多反应监测法同时测定饮用水源地水体中18种多氯联苯的方法,给出了测量线性范围,线性关系良好,相关系数大于0.998。水中加标浓度为1.00、5.00、10.0ng/L时,平均加标回收率分别为75.6%~96.0%、90.6%~105%和92.4%~102%,相对标准偏差分别为19.8%~11.8%、4.2%~12.9%和4.3%~9.9%,检出限为0.29~0.57ng/L。结果表明,在测定水体中痕量多氯联苯方面,三重串联四极杆气相质谱相对于气相色谱-电子捕获检测和气相色谱质谱-选择离子检测具有更高的灵敏度和准确度,具有更广泛的应用。  相似文献   