共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Disinfection. 总被引:1,自引:0,他引:1
3.
4.
Disinfection by-products in Finnish drinking waters 总被引:11,自引:0,他引:11
Disinfection by-products (DBPs) were measured in plant effluents of 35 Finnish waterworks, which utilized different treatment processes and raw water sources. DBPs were measured also from the distribution systems of three waterworks. Di- and trichloroacetic acids, and chloroform were the major DBPs found in treated water samples. The concentration of six haloacetic acids (HAA6) exceeded the concentrations of trihalomethanes (THMs). Chlorinated drinking waters (DWs) originating from surface waters contained the highest concentration of HAA6 and THMs: 108 and 26 microg/l, respectively. The lowest concentrations of DBPs were measured from ozonated and/or activated carbon filtrated and chloraminated DWs. Higher concentrations of HAA6, THMs, and adsorbable organic halogens were measured in summer compared to winter. The levels of chlorinated acetic acids, chloroform, and bromodichloromethane correlated positively with mutagenicity. Past mutagenicity levels of DWs were examined. A major reduction in the use of prechlorination, increased use of chloramine disinfection, and better removal of organic carbon were the most important reasons for the 69% decrease in mutagenicity from 1985 to 1994. 相似文献
5.
6.
Direct current applied to a tin oxide anode submersed in water has the potential to generate hydroxyl radicals, a strong chemical oxidant. Tin oxide anode systems, which may represent a viable alternative disinfectant, were investigated for the disinfection of secondary effluents. Coliform bacteria in the effluent were effectively inactivated in a bench-scale tin oxide disinfection system. The number of anodes in the tin oxide disinfection system influenced the steady-state concentration of hydroxyl radicals and, consequently, the contact time necessary to achieve a specified dose. The life expectancy of the anodes was greater than 30 days and no appreciable loss of tin was observed over a 5-day period. A preliminary estimate of the capital and operating costs of a pilot- or full-scale tin oxide disinfection system designed to meet a discharge requirement of 23 most probable number/100 mL at a 3 785-m3/d (1-mgd) facility was comparable to UV and chlorination/dechlorination facilities. Based on this preliminary assessment, tin oxide disinfection systems are a promising alternative disinfectant for secondary effluents. 相似文献
7.
管道分质供水消毒副产物及其安全性评价 总被引:2,自引:0,他引:2
消毒副产物是饮用水中应主要控制的毒害物。然而,管道分质供水中消毒副产物特征及污染水平很少研究。以某一管道分质供水工程为例,对其中消毒副产物进行了详细研究。研究结果表明,管道分质供水消毒副产物在量与质上与其源水自来水存在很大差别。在管道分质供水中消毒副产物量少,一般不到自来水的1/10,且主要是一些毒性较低、与供水管材有关的溶出物。据此计算出管道分质供水由消毒副产物引起的致癌风险性一般不到其源水的1/10,其安全性大大提高。 相似文献
8.
Wastewaters of private household septic tanks and cesspools have been treated with peracetic acid (1-2 g L(-1)). Adding 1 g L(-1) peracetic acid to wastewaters was easy and has been found to be effective in destroying enteric indicator microorganisms. The careful mixing of peracetic acid and wastewater was found to be important. Winter periods with frozen soil, ice and snow did not constitute extra problems. The bad smell of these wastewaters almost totally disappeared during the treatment. When wastewaters treated with peracetic acid were emptied into animal slurry tanks, hygienization still continued in the mixture of animal slurry and the wastewaters. These wastewaters could thus be released into agricultural soil without risk of microbiological pollution to groundwaters. 相似文献
9.
Disinfection of wastewater solids (waste activated solids [WAS]) by interstitial vapor generation was investigated. In addition to the magnitude of disinfection, the amount of water removed and cost relative to traditional residuals disinfection processes was also examined. The process of interstitial vapor generation occurs as a result of the rapid heating of liquid in the interstices of the solid-liquid array. Intense heating causes boiling of the slurry liquid, resulting in an expanding vapor front that simultaneously dewaters the wastewater solids and contributes to the destruction of viable pathogenic microorganisms. Objectives of the study were threefold: (1) to validate disinfection of WAS using the interstitial vapor technique; (2) establish the degree of possible drying of the residuals using the techniques; and (3) establish the key operating variables for the process. Results showed a significant reduction in the most probable number of total coliforms and Escherichia coli (E. coli). Specifically, greater than four-log unit reductions were produced for both total coliform and E. coli bacteria. In addition to quantifying the reduction in bacteria, the percent solids were increased from an initial amount of 7.6% (mass basis) to a final solids content greater than 90% using optimal processing conditions. Cost comparisons were also conducted and shown to be quite favorable when compared with traditional disinfection methods such as lime addition. Because of the high level of E. coli reduction achieved, the process of interstitial vapor generation is shown to be capable of converting a class B biosolids into a class A pathogen reduced product. For example, an initial most probable number (MPN) of 1.2 x 10(6) E. coli bacteria were reduced to 19 at the extreme conditions of the process, well below the requirement of an MPN of 1000 for fecal coliform bacteria. Given its ability to disinfect and dewater wastewater solids, the interstitial vapor generation process was found to be a robust and beneficial technique to produce an environmental and publicly acceptable recyclable biosolids resource. 相似文献
10.
Disinfection of surfaces by photocatalytic oxidation with titanium dioxide and UVA light 总被引:11,自引:0,他引:11
Kühn KP Chaberny IF Massholder K Stickler M Benz VW Sonntag HG Erdinger L 《Chemosphere》2003,53(1):71-77
Particularly in microbiological laboratories and areas in intensive medical use, regular and thorough disinfection of surfaces is required in order to reduce the numbers of bacteria and to prevent bacterial transmission. The conventional methods of disinfection with wiping are not effective in the longer term, cannot be standardized, are time- and staff-intensive and use aggressive chemicals. Disinfection with hard ultraviolet C (UVC) light is usually not satisfactory, as the depth of penetration is inadequate and there are occupational medicine risks. Photocatalytic oxidation on surfaces coated with titanium dioxide (TiO2) might offer a possible alternative. In the presence of water and oxygen, highly reactive OH-radicals are generated by TiO2 and mild ultraviolet A (UVA). These radicals are able to destroy bacteria, and may therefore be effective in reducing bacterial contamination. Direct irradiation with UVC however can produce areas of shadow in which bacteria are not inactivated. Using targeted light guidance and a light-guiding sheet (out of a UVA-transmittant, Plexiglas, for example), as in the method described in the present study, bacterial inactivation over the entire area is possible. The effectiveness of the method was demonstrated using bacteria relevant to hygiene such as Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Enterococcus faecium. For these bacteria, a reduction efficiency (RE) more than 6log10 steps in 60 min was observed. Using Candida albicans, a RE of 2log10 steps in 60 min was seen. Light and scanning electron microscopic examinations suggest that the germ destruction achieved takes place through direct damage to cell walls caused by OH-radicals. 相似文献
11.
12.
Yannan Huang Lisbeth Truelstrup Hansen Colin M. Ragush Rob C. Jamieson 《Environmental science and pollution research international》2018,25(33):32881-32893
Wastewater stabilization ponds (WSPs) are commonly used to treat municipal wastewater in Arctic Canada. The biological treatment in the WSPs is strongly influenced by climatic conditions. Currently, there is limited information about the removal of fecal and pathogenic bacteria during the short cool summer treatment season. With relevance to public health, the objectives of this paper were to determine if treatment in arctic WSPs resulted in the disinfection (i.e., removal of fecal indicator bacteria, Escherichia coli) and removal of selected human bacterial pathogens from the treated effluent. The treatment performance, with focus on microbial removal, was assessed for the one-cell WSP in Pond Inlet (Nunavut [NU]) and two-cell WSP in Clyde River (NU) over three consecutive (2012–2014) summer treatment seasons (late June-early September). The WSPs provided a primary disinfection treatment of the wastewater with a 2–3 Log removal of generic indicator E. coli. The bacterial pathogens Salmonella spp., pathogenic E. coli, and Listeria monocytogenes, but not Campylobacter spp. and Helicobacter pylori, were detected in the untreated and treated wastewater, indicating that human pathogens were not reliably removed. Seasonal and annual variations in temperature significantly (p < 0.05) affected the disinfection efficiency. Improved disinfection and pathogen removal was observed for the two-cell system in Clyde River as compared to the one-cell system in Pond Inlet. A quantitative microbial risk assessment should be performed to determine if the release of low levels of human pathogens into the arctic environment poses a human health risk. 相似文献
13.
MBR出水氯、紫外、臭氧单独与组合消毒 总被引:1,自引:0,他引:1
采用氯、紫外和臭氧单独与2种组合工艺对MBR工艺中试出水进行了消毒实验,研究了不同消毒方式对指示性微生物的去除效果以及消毒副产物三卤甲烷(THMs)生成量随有效氯投加量的变化.结果表明,组合工艺消毒效果明显优于单独消毒效果,紫外剂量为25 mJ/cm2与有效氯投加量为3 mg/L的紫外与氯组合、臭氧投加量为6 mg/L与有效氯投加量为4 mg/L的臭氧与氯组合2种工艺消毒后出水中的总大肠菌群指标均满足《污水再生利用城市杂用水水质》(GB/T 18920-2002)的要求.THMs生成量随着有效氯投加量的增加而增加.相对紫外与氯组合消毒,臭氧与氯组合消毒可以大幅度降低THMs生成量,有效氯投加量为4 mg/L时,THMs生成浓度为14.11 μg/L,比氯单独消毒过程降低了37.19%. 相似文献
14.
15.
以南方某市具有代表性的7个自来水厂为研究对象,对不同季节和不同处理工艺下的原水、出厂水和管网水的9个常规水质参数和2类含碳消毒副产物进行了检测,考察了水质指标随季节的变化规律和处理工艺对不同水质指标的影响,分析了常规水质参数与消毒副产物生成量之间的关系。结果表明:7个自来水厂出厂水均检出三卤甲烷(trihalomethanes,THMs)和卤乙酸(haloacetic acids,HAAs);THMs平均质量浓度为8.70~29.35 μg·L−1,HAAs平均质量浓度为13.22~39.06 μg·L−1;管网水中2类消毒副产物浓度水平较出厂水略有增加;THMs的季节变化规律为冬季>春季≈秋季>夏季,HAAs的季节变化性不强。利用IBM SPSS Statistics 20进行了Spearman秩相关系数分析,并分别以原水和出厂水水质参数来建立出厂水THMs或HAAs生成量的回归方程。结果表明:THMs质量浓度预测效果良好,可用于自来水厂水质的化学安全性预警;但对于HAAs质量浓度预测,无论采用原水还是出厂水水质参数所建立的预测方程,预测结果均不理想。 相似文献
16.
Peiyong Ning Dan Shan Enlv Hong Lumin Liu Yun Zhu Runmeng Cui 《Journal of the Air & Waste Management Association (1995)》2020,70(7):721-728
ABSTRACT
Gaseous chlorine dioxide (ClO2) is one of the most promising air disinfectants. In this study, an ultra-low concentration of ClO2 gas (< 1.2 mg/m3) was generated in an office at various levels of humidity and illuminance to investigate the decay law. The disinfection efficiency and metal corrosiveness of ultra-low concentrations of ClO2 gas were also studied using an experimental chamber. At 48% and 75% humidity, the decay rate constants of ClO2 gas were 0.0034 min?1 and 0.0036 min?1, respectively. The rate of decline of the ClO2 concentration increased as the humidity of the environment increased. The decay rate constant of ClO2 gas at an illuminance of 76 lux and 3429 lux was 0.0034 min?1 and 0.00427 min?1, respectively; hence, the decay rate increased with increased illumination. At a humidity of 72% and illuminance of 2112 lux, the decay rate constant reached 0.00880 min?1. The effects of humidity and illuminance on the attenuation of the ClO2 concentration were strongly synergistic. When the gas concentration was maintained below 0.9 mg/m3, the disinfection rate of ClO2 on bacteria (P. aeruginosa, V. mimicus and S. aureus) exceeded 99.9%; thus, ClO2 gas exhibited a high disinfection efficiency. In addition, there was no corrosion to various metals by ClO2 under the same conditions. Consequently, gaseous ClO2 at ultra-low concentrations has a high sterilization efficiency and is non-corrosive to metals. 相似文献
17.
Chlorination for drinking water forms various disinfection byproducts (DBPs) of trihalomethanes (THMs) and haloacetic acids (HAAs). Chlorination has been attributed to the destruction of activated aromatic sites of the natural organic matter (NOM) predominantly at electron rich sites. Experiments with Istanbul surface waters showed that the magnitude of the decrease in the ultraviolet (UV) absorbance at 272 nm (UV272) was an excellent indicator of destruction of these sites by chlorine. The main objective of the present study is to develop the differential UV272 absorbance (ΔUV272) related models for the prediction of the formation of THM, HAA, and their species in raw water samples from Terkos, Buyukcekmece, and Omerli lakes under different chlorination conditions. Significant factors affecting DBP formation in the raw waters were identified through numerical and graphical techniques. The R2 values of the models varied between 0.94 and 0.97, indicating excellent predictive ability for THM4 and HAA9 in the raw waters. The models were validated using additional data. The results of this study concluded that addition of ΔUV272 parameter into THM4 and HAA9 models make the prediction of these DBP compounds more precisely than those of DBP models developed in the past. A better understanding of these modeling systems will help the water treatment plant operators to minimize the DBP formation, providing a healthier and better drinking water quality as well as identifying strategies to improve water treatment and disinfection processes. 相似文献
18.
Disinfection of an advanced primary effluent using a continuous-flow combined peracetic acid/ultraviolet (PAA/UV) radiation system was evaluated. The purpose was to determine whether the maximum microbial content, established under Mexican standards for treated wastewaters meant for reuse--less than 240 most probable number fecal coliforms (FC)/100 mL--could be feasibly accomplished using either disinfectant individually, or the combined PAA/UV system. This meant achieving reduction of up to 5 logs, considering initial concentrations of 6.4 x 10(+6) to 5.8 x 10(+7) colony forming units/100 mL. During the tests performed under these experiments, total coliforms (TC) were counted because FC, at the most, will be equal to TC. Peracetic acid disinfection achieved less than 1.5 logs TC reduction when the C(t) x t product was less than 2.26 mg x minimum (min)/L; 3.8 logs for C(t) x t 4.40 mg x min/L; and 5.9 logs for C(t) x t 24.2 mg x min/L. In continuous-flow UV irradiation tests, at a low-operating flow (21 L/min; conditions which produced an average UV fluence of 13.0 mJ/cm2), the highest TC reduction was close to 2.5 logs. The only condition that produced a disinfection efficiency of approximately 5 logs, when both disinfection agents were used together, was the combined process dosing 30 mg PAA/L at a pilot plant flow of 21 L/min and contact time of 10 minutes to attain an average C(t) x t product of 24.2 mg x min/L and an average UV fluence of 13 mJ/cm2. There was no conclusive evidence of a synergistic effect when both disinfectants were employed in combination as compared to the individual effects achieved when used separately, but this does not take into account the nonlinearity (tailing-off) of the dose-response curve. 相似文献
19.
Vedat Uyak Senay Soylu Tufan Topal Nazan Karapinar Kadir Ozdemir Sahin Ozaydin 《Environmental Forensics》2014,15(2):190-205
This study presents the seasonal and spatial variations of trihalomethanes (THMs) and haloacetic acids (HAAs) in 30 sampling points within three water distribution systems of Istanbul City, Turkey. The effects of surface water quality, seasonal variation, and species differences were examined. The occurrence of chlorinated THMs and HAAs levels was considerably lower in the system in which raw water is subjected to pre-ozonation versus pre-chlorination. Seasonal analysis of the data indicated that the median concentration of four THMs (THM4) was higher than nine HAAs (HAA9) concentrations in all three distribution systems sampling points. For all distribution systems monitored, the highest median THM4 and HAA9 concentrations were observed in the spring and summer season, while the lowest concentrations of these disinfection byproduct (DBP) compounds were obtained in the fall and winter period. Due to the higher level of bromide in supplying waters of these two systems, moderate levels of brominated DBP species have been observed in the Kagithane and Buyukcekmece distribution systems districts. In fact, Spearman partial correlations (Spearman rank correlation coefficients [rs]) tend to be higher among analogues in terms of number and types of substituent, especially TCAA with TCM (rs 0.91), and DBAA with DBCM (rs 0.90). In contrast, the hydraulic (residence time and flow rate) and chemical mechanisms (hydrolysis, volatilization, and adsorption) affect the fate and transport of DBPs in distribution systems. Seasonal and spatial variations of DBPs presented in this study have important implications on regulatory issues and from an epidemiological point of view. 相似文献