共查询到20条相似文献,搜索用时 15 毫秒
1.
Modeling relationships between indoor and outdoor air quality 总被引:4,自引:0,他引:4
Information about the ratio between indoor and outdoor concentrations (IO ratios) of air pollutants is a crucial component in human exposure assessment. The present study examines the relationship between indoor and outdoor concentrations as influenced by the combined effect of time patterns in outdoor concentrations, ventilation rate, and indoor emissions. Two different mathematical approaches are used to evaluate IO ratios. The first approach involves a dynamic mass balance model that calculates distributions of transient IO ratios. The second approach assumes a linear relationship between indoor and outdoor concentrations. We use ozone and benzene as examples in various modeling exercises. The modeled IO ratio distributions are compared with the results obtained from linear fits through plots of indoor versus outdoor concentrations. 相似文献
2.
Christer Johansson Lars Burman Bertil Forsberg 《Atmospheric environment (Oxford, England : 1994)》2009,43(31):4843-4854
The “Stockholm Trial” involved a road pricing system to improve the air quality and reduce traffic congestion. The test period of the trial was January 3–July 31, 2006. Vehicles travelling into and out of the charge cordon were charged for every passage during weekdays. The amount due varied during the day and was highest during rush hours (20 SEK = 2.2 EUR, maximum 60 SEK per day). Based on measured and modelled changes in road traffic it was estimated that this system resulted in a 15% reduction in total road use within the charged cordon. Total traffic emissions in this area of NOx and PM10 fell by 8.5% and 13%, respectively. Air quality dispersion modelling was applied to assess the effect of the emission reductions on ambient concentrations and population exposure. For the situations with and without the trial, meteorological conditions and other emissions than from road traffic were kept the same. The calculations show that, with a permanent congestion tax system like the Stockholm Trial, the annual average NOx concentrations would be lower by up to 12% along the most densely trafficked streets. PM10 concentrations would be up to 7% lower. The limit values for both PM10 and NO2 would still be exceeded along the most densely trafficked streets. The total population exposure of NOx in Greater Stockholm (35 × 35 km with 1.44 million people) is estimated to decrease with a rather modest 0.23 μg m?3. However, based on a long-term epidemiological study, that found an increased mortality risk of 8% per 10 μg m?3 NOx, it is estimated that 27 premature deaths would be avoided every year. According to life-table analysis this would correspond to 206 years of life gained over 10 years per 100 000 people following the trial if the effects on exposures would persist. The effect on mortality is attributed to road traffic emissions (likely vehicle exhaust particles); NOx is merely regarded as an indicator of traffic exposure. This is only the tip of the ice-berg since reductions are expected in both respiratory and cardiovascular morbidity. This study demonstrates the importance of not only assessing the effects on air quality limit values, but also to make quantitative estimates of health impacts, in order to justify actions to reduce air pollution. 相似文献
3.
The authors of this paper chose several target compounds that have been found in average US homes, applied the current United States Environmental Protection Agency (USEPA) Superfund risk assessment methodologies to indoor air quality, and produced risk numbers for hazard quotients and predicted increases in incidence of cancer which would be unacceptable at US hazardous waste sites. The calculations were made for the average child and adult with USEPA default exposure values. Calculations were also made for a worst case scenario using maximum concentrations and exposure estimates defined by the USEPA as describing the reasonable exposure (RME). Significant cancer risks and non-cancer hazard quotients were predicted. 相似文献
4.
S R Hayes 《Journal of the Air & Waste Management Association》1991,41(2):161-170
Currently, outdoor ozone levels in many U.S. cities exceed the primary health-based national ambient air quality standard. While outdoor ozone levels are an important measure of the severity of those exceedances, people typically spend more than 80 percent of their time indoors, where ozone levels are lower. Indoor ozone levels range from 10 to 80 percent of outdoor levels, with many people receiving a substantial portion of their ozone exposure while indoors. This paper uses an indoor air quality model (IAQM) to estimate indoor ozone levels by microenvironment type (home, office, and vehicle) and configuration (windows open, windows closed, older construction, weatherized, and air conditioned). The formulation of IAQM is discussed, along with specification of model parameters for ozone. The multicompartment version of IAQM is described, with a single-compartment version used for the analyses. IAQM-calculated ozone indoor-outdoor ratios compare well with research-reported values. Results indicate that ozone peak-concentration indoor-outdoor ratios range as follows: home--0.65 (windows open), 0.36 (air conditioned), 0.23 (typical construction, windows closed), and 0.05 (energy-efficient construction, windows closed); office--0.82 (heating, ventilation and air conditioning systems supplying 100 percent outdoor air), 0.60 (typical HVAC), and 0.32 (energy-efficient HVAC); and vehicle--0.41 (85 mph), 0.33 (55 mph), and 0.21 (10 mph). Analysis results are presented to characterize IAQM's sensitivity to assumed model parameters. 相似文献
5.
Takeshi Ohura Takashi Amagai Xueyou Shen Shuang Li Ping Zhang Lizhong Zhu 《Atmospheric environment (Oxford, England : 1994)》2009,43(40):6352-6359
We conducted a comparative study on the indoor air quality for Japan and China to investigate aromatic volatile organic compounds (VOCs) in indoor microenvironments (living room, bedroom, and kitchen) and outdoors in summer and winter during 2006–2007. Samples were taken from Shizuoka in Japan and Hangzhou in China, which are urban cities with similar latitudes. Throughout the samplings, the indoor and outdoor concentrations of many of the targeted VOCs (benzene, toluene, ethylbenzene, xylenes, and trimethylbenzenes) in China were significantly higher than those in Japan. The indoor concentrations of VOCs in Japan were somewhat consistent with those outdoors, whereas those in China tended to be higher than those outdoors. Here, we investigated the differences in VOC concentrations between Japan and China. Compositional analysis of indoor and outdoor VOCs showed bilateral differences; the contribution of benzene in China was remarkably higher than that in Japan. Significant correlations (p < 0.05) for benzene were observed among the concentrations in indoor microenvironments and between the outdoors and living rooms or kitchens in Japan. In China, however, significant correlations were observed only between living rooms and bedrooms. These findings suggest differences in strengths of indoor VOC emissions between Japan and China. The source characterizations were also investigated using principal component analysis/absolute principal component scores. It was found that outdoor sources including vehicle emission and industrial sources, and human activity could be significant sources of indoor VOC pollution in Japan and China respectively. In addition, the lifetime cancer risks estimated from unit risks and geometric mean indoor concentrations of carcinogenic VOCs were 2.3 × 10?5 in Japan and 21 × 10?5 in China, indicating that the exposure risks in China were approximately 10 times higher than those in Japan. 相似文献
6.
7.
杭州某高校室内空气质量状况调查分析 总被引:1,自引:0,他引:1
为了解高校室内污染状况,调查选取杭州市某高校75间教室按照装修完成后时间长短分成5组,分别于2011年3、6月进行氡、氨、甲醛和苯系物(苯、甲苯和二甲苯),浓度的检测.结果显示,甲醛和苯系物浓度与装修完成后时间长短、通风情况、温度、湿度密切相关,装修完成后1.0年内的教室浓度显著高于其余组(P<0.05).除装修完成后5.0年以上组外,各组甲醛和苯系物含量6月都呈现极显著增高趋势(p<0.01).所有室内氡和氨浓度均未超标.总体来说,该校室内空气质量状况总体良好,但新建建筑物的室内空气污染存在一定的安全隐患. 相似文献
8.
Hua-Hsien Chiu Hsiu-Mei Chiang Cho-Ching Lo Ching-Yen Chen Hung-Lung Chiang 《Atmospheric environment (Oxford, England : 1994)》2009,43(36):5743-5749
Essential oils containing aromatic compounds can affect air quality when used indoors. Five typical and popular essential oils—rose, lemon, rosemary, tea tree and lavender—were investigated in terms of composition, thermal characteristics, volatile organic compound (VOC) constituents, and emission factors. The activation energy was 6.3–8.6 kcal mol?1, the reaction order was in the range of 0.6–0.8, and the frequency factor was 0.01–0.24 min?1. Toluene, 1,2,3-trimethylbenzene, 1,2,4-trimethylbenzene, n-undecane, p-diethylbenzene and m-diethylbenzene were the predominant VOCs of evaporating gas of essential oils at 40 °C. In addition, n-undecane, p-diethylbenzene, 1,2,4-trimethylbenzene, m-diethylbenzene, and 1,2,3-trimethylbenzene revealed high emission factors during the thermogravimetric (TG) analysis procedures. The sequence of the emission factors of 52 VOCs (137–173 mg g?1) was rose ≈ rosemary > tea tree ≈ lemon ≈ lavender. The VOC group fraction of the emission factor of aromatics was 62–78%, paraffins were 21–37% and olefins were less than 1.5% during the TG process. Some unhealthy VOCs such as benzene and toluene were measured at low temperature; they reveal the potential effect on indoor air quality and human health. 相似文献
9.
Salthammer T 《Chemosphere》2011,82(11):1507-1517
The importance of good indoor air quality for the health of the individual was recognized as long as 150 years ago and that period also saw recommendations, which essentially related to questions of ventilation and carbon dioxide. The first evaluation standards for organic and inorganic substances were laid down in the 1970s, often on an empirical basis. It was in the mid-1980s of the 20th century that a shift occurred towards systematically evaluating the results of indoor air measurements, carrying out representative environmental surveys and deriving guideline values and reference values on the basis of toxicological, epidemiological and statistical criteria. Generally speaking the indoor environment is an area which can only be assessed with difficulty since its occupants are in most cases exposed to mixtures of substances and there can be great local and temporal variations in the substance spectrum. Data are available today for a large number of substances and this makes it possible, with the aid of statistically derived reference values and toxicologically based guideline values, to make useful recommendations regarding good indoor air quality. Nevertheless, it is still difficult to evaluate reactive compounds and reaction products. What is disadvantageous, however, is the fact that different guideline values may be published for one and the same substance, whose justification and area of application are often not transparent. A guideline or reference value can only be regarded as rational when necessary and when a strategy for its verification is available. 相似文献
10.
Youn-Suk Son Jae-Sik Jeon Hyung Joo Lee In-Cheol Ryu 《Journal of the Air & Waste Management Association (1995)》2014,64(9):1054-1061
In this study, variations of particulate matter (PM) concentrations in subway trains following installation of platform screen doors (PSDs) in the Seoul subway system were investigated. PM samples were collected in the trains on subway lines 1–8 before and after installation of PSDs. It was found that the mean PM10 concentration in the trains after PSDs installation increased significantly by 29.9% compared to that before installation. In particular, the increase of PM10 in line 6 was the highest at 103%. When the relationship between PM10 and PM2.5 was compared, coefficients of determination (r2) before and after PSDs installations were 0.696 and 0.169, respectively. This suggests that air mixing between the platform and the tunnel after PSDs installation was extremely restricted. In addition, the indoor/outdoor PM10 ratio following PSDs installation increased from 1.32 to 2.97 relative to the period with no installed PSDs. Furthermore, this study revealed that PM levels in subway trains increased significantly after all underground PSDs were put in use. Several potential factors were examined that could result in this PM increase, such as train ventilation systems, operational conditions, passenger volume, subway depth, and the length of underground segments.
ImplicationsPM10 concentrations inside the subway trains increased after PSDs installation. This indicates that air quality in trains was very seriously impacted by PSDs. PM10 levels were also influenced by the tunnel depth and length of the underground segments. To prevent the adverse effect on human health by PM10 emitted from the tunnel, an applicable ventilation system to reduce PM10 is required inside trains and tunnels. 相似文献
11.
Jyun-Hong Shen Yeoung-Sheng Wang Jhan-Ping Lin Sheng-Hung Wu 《Journal of the Air & Waste Management Association (1995)》2014,64(1):13-18
This study investigated the indoor air quality (IAQ) conditions of carbon dioxide (CO2), carbon monoxide (CO), ozone (O3), formaldehyde (HCHO), total volatile organic compounds (TVOCs), and bio-aerosols (bacteria and fungi) in a respiratory type of medical facility in Chia-Yi County in southern Taiwan. Among those IAQ conditions, the concentrations of CO, O3, and HCHO exceeded the regulation values of the Taiwan Environmental Protection Administration (EPA) mostly in the morning. The concentrations of bacteria and fungi did not exceed the regulation values but still posed potential health and environment problems for workers, patients, and visitors. Therefore, self-made silver-coated zeolite (AgZ) was used as a filter material in air cleaners to remove bio-aerosols in the respiratory care ward (RCW), and the removals were still effective after 120 hr. The cumulative bio-aerosol removals for bacteria and fungi were 900 and 1,088 colony-forming units (CFU) g?1 after 24 hr and were above 3,100 and 2,700 CFU g?1 after 120 hr. From the research results, it is suggested that AgZ filtering could be used as a feasible engineering measure for hospitals to control their bacteria and fungi parameters in IAQ management. Hospitals should maintain their environmental management and monitoring programs and use different engineering measures to improve different IAQ parameters.
Implications: This study investigated the IAQ conditions in the field at a hospital in Chia-Yi County in southern Taiwan. Although concentrations of most parameters were still within the regulation values, the concentrations of CO, O3, and HCHO were partially exceeded. We propose a method using an air cleaner with silver-coated zeolite (AgZ) as a possible engineering measure, and there were effective reductions of bacteria and fungi to lower levels with antibacterial effects after 120 hr. Furthermore, this study implies that hospitals should continuously maintain environmental monitoring programs and adopt optimal engineering measures for different needs. 相似文献
12.
Chang TJ 《Journal of the Air & Waste Management Association (1995)》2002,52(9):1043-1053
A computational fluid dynamics technique was used to evaluate the effect of traffic pollution on indoor air quality of a naturally ventilated building for various ventilation control strategies. The transport of street-level nonreactive pollutants emitted from motor vehicles through the indoor environment was simulated using the large eddy simulation (LES) of the turbulent flows and the pollutant transport equations. The numerical model developed herein was verified by available wind-tunnel measurements. Good agreement with the measured velocity and concentration data was found. Twelve sets of numerical scenario simulations for various roof- and side-vent openness and outdoor wind speeds were carried out. The effects of the air change rate, the indoor airflow pattern, and the external pollutant dispersion on indoor air quality were investigated. The control strategies of ventilation rates and paths for reducing incoming vehicle pollutants and maintaining a desirable air change rate are proposed to reduce the impact of outdoor traffic pollution during traffic rush hours. It was concluded that the windward side vent is a significant factor contributing to air change rate and indoor air quality. Air intakes on the leeward side of the building can effectively reduce the peak and average indoor concentration of traffic pollutants, but the corresponding air change rate is relatively low. Using the leeward cross-flow ventilation with the windward roof vent can effectively lower incoming vehicle pollutants and maintain a desirable air change rate during traffic rush hours. 相似文献
13.
Evaluating sources of indoor air pollution 总被引:2,自引:0,他引:2
B A Tichenor L A Sparks J B White M D Jackson 《Journal of the Air & Waste Management Association》1990,40(4):487-492
Evaluation of indoor air pollution problems requires an understanding of the relationship between sources, air movement, and outdoor air exchange. Research is underway to investigate these relationships. A three-phase program is being implemented: 1) Environmental chambers are used to provide source emission factors for specific indoor pollutants; 2) An IAQ (Indoor Air Quality) model has been developed to calculate indoor pollutant concentrations based on chamber emissions data and the air exchange and air movement within the indoor environment; and 3) An IAQ test house is used to conduct experiments to evaluate the model results. Examples are provided to show how this coordinated approach can be used to evaluate specific sources of indoor air pollution. Two sources are examined: 1) para-dichlorobenzene emissions from solid moth repellant; and 2) particle emissions from unvented kerosene heaters. The evaluation process for both sources followed the three-phase approach discussed above. Para-dichlorobenzene emission factors were determined by small chamber testing at EPA's Air and Energy Engineering Research Laboratory. Particle emission factors for the kerosene heaters were developed in large chambers at the J. B. Pierce Foundation Laboratory. Both sources were subsequently evaluated in EPA's IAQ test house. The IAQ model predictions showed good agreement with the test house measurements when appropriate values were provided for source emissions, outside air exchange, in-house air movement, and deposition on "sink" surfaces. 相似文献
14.
Sarah E. Frey Hugo Destaillats Sebastian Cohn Sherry Ahrentzen 《Journal of the Air & Waste Management Association (1995)》2014,64(11):1251-1259
A survey of key indoor air quality (IAQ) parameters and resident health was carried out in 72 apartments within a single low-income senior housing building in Phoenix, Arizona. Air sampling was carried out simultaneously with a questionnaire on personal habits and general health of residents. Mean PM10 concentrations are 66±16, 58±13, and 24±3 μg/m3 and mean PM2.5 concentrations are 62±16, 53±13, and 20±2 μg/m3 for the living room, kitchen, and outdoor balcony, respectively. Median PM10 concentrations are 17, 18 and 17 μg/m3 and median PM2.5 concentrations are 13, 14, and 13 μg/m3, respectively. The initial results indicate that increased indoor particle concentrations coincide with residents who report smoking cigarettes. Indoor formaldehyde concentrations revealed median levels of 36.9, 38.8, and 4.3 ppb in the living room, kitchen, and balcony, respectively. Results show that 36% of living room samples and 44% of kitchen samples exceeded the Health Canada REL for chronic exposure to formaldehyde (40 ppb). Associations between occupants’ behavior, self-reported health conditions, and IAQ are evaluated.
Implications:This study provides a characterization of indoor air quality (IAQ) of subsidized apartments for seniors in Phoenix, Arizona. It is important for policy makers to understand the environments in which low-income seniors live, as they are vulnerable to the health impacts from poor IAQ. Formaldehyde concentrations were found to exceed the Health Canada 8-hr reference exposure level (REL) for up to 44% of indoor samples. Particulate matter exposure was governed by resident behavior (i.e., smoking). Associations between occupants’ behavior, IAQ, and self-reported health conditions are evaluated. This work can provide a foundation for subsequent remediation of IAQ conditions. 相似文献
15.
Viswanathan S Eria L Diunugala N Johnson J McClean C 《Journal of the Air & Waste Management Association (1995)》2006,56(1):56-67
The impact of major gaseous and particulate pollutants emitted by the wildfire of October 2003 on ambient air quality and health of San Diego residents before, during, and after the fire are analyzed using data available from the San Diego County Air Pollution Control District and California Air Resources Board. It was found that fine particulate matter (PM) levels exceeded the federal daily 24-hr average standard during the fire. There was a slight increase in some of the gaseous pollutants, such as carbon monoxide, which exceeded federal standards. Ozone (O3) precursors, such as total hydrocarbons and methane gases, experienced elevated concentration during the fire. Fortunately, the absence of sunlight because of the cloud of thick smoke that covered most of the county during the fire appears to have prevented the photochemical conversion of the precursor gases to harmful concentrations of O3. Statistical analysis of the compiled medical surveillance data has been used to establish correlations between pollutant levels in the region and the resultant health problems experienced by the county citizens. The study shows that the increased PM concentration above the federal standard resulted in a significant increase in hospital emergency room visits for asthma, respiratory problems, eye irritation, and smoke inhalation. On the basis of the findings, it is recommended that hospitals and emergency medical facilities engage in pre-event planning that would ensure a rapid response to an impact on the healthcare system as a result of a large wildfire and appropriate agencies engage in the use of all available meteorological forecasting resources, including real-time satellite imaging assets, to accurately forecast air quality and assist firefighting efforts. 相似文献
16.
Present day Mexico City was established on the banks of the now dead Lake Texcoco by Aztec Indians in a.d. 1325. Over time, increasing population growth, urbanization, vehicular traffic and the number of diverse stationary sources, coupled with its topography and the resultant frequency of prevalent stagnant air masses make Mexico City one of the most polluted areas in the world. Use of biological indicator plants since the early 1970s has shown the critical nature of phytotoxic photochemical oxidants in the region. More recent empirical studies with bean, soybean and pine species confirm these observations and raise concern regarding the geographic magnitude of the problem. Surface measurements of air quality in the region are inadequate and require much additional support. Ultimately, ambient air quality measurements must be coupled with the observations on responses of sensitive vegetation. While the results presented in this paper are primarily observational or qualitative, they hopefully serve the purpose of bringing attention to a critical air quality issue in a developing country. 相似文献
17.
18.
Shelly L. Miller Peter Scaramella Joseph Campe Cynthia W. Goss Sandra Diaz-Castillo Ed Hendrikson Carolyn DiGuiseppi Jill Litt 《Atmospheric environment (Oxford, England : 1994)》2009,43(35):5661-5667
An indoor air quality assessment was conducted on 100 homes of recent Mexican immigrants in Commerce City, Colorado, an urban industrial community north of Denver. Head of households were administered a family health survey, filled out an activity diary, and participated in a home inspection. Carbon monoxide (CO) and carbon dioxide (CO2) were measured for 24 h inside the main living area and outside of the homes. Harvard Impactors were used to collect 24-h samples of PM2.5 at the same locations for gravimetric analysis. Dust samples were collected by vacuuming carpeting and flooring at four locations within the home and analyzed by ELISA for seven allergens. Mean indoor and outdoor PM2.5 levels were 27.2 and 8.5 μg m−3, respectively. Indoor PM2.5 and CO2 were elevated in homes for which the number of hours with door/window open was zero compared to homes in which the number of hours was high (>15 h). Indoor PM2.5 levels did not correlate with outdoor levels and tended to increase with number of inhabitants, and results indicate that the source of indoor particles were occupants and their activities, excluding smoking and cooking. Mean indoor CO2 and CO levels were 1170 and 2.4 ppm, respectively. Carbon monoxide was higher than the 24-h National Ambient Air Quality Standard in 3 of the homes. The predominant allergens were cat (Fel d 1) and mouse (Mus m 1) allergens, found in 20 and 34 homes, respectively. 相似文献
19.
Wanyang Liu Satoshi Takahashi Yui Sakuramachi Kouji H. Harada Akio Koizumi 《Chemosphere》2013,90(5):1672-1677
The fluorotelomer alcohols (FTOHs) have been detected in various environmental compartments, including indoor and outdoor air, in North America and Europe. In our previous studies, FTOHs were detected at a relative higher concentration in outdoor air in the Keihan (Kyoto–Osaka, one of the major industrial zones) area, Japan compared to reported data. The exposure level of FTOHs in indoor air in the Keihan area remains unclear. In the present study, indoor air FTOH concentrations were investigated using a passive air sampler containing activated carbon felts. The indoor air sampling was conducted in 49 households of the Keihan area, during winter and summer 2008. Most samples contained 6:2 FTOH, 8:2 FTOH, 10:2 FTOH and 8:2 FTOAc. The median concentration of 8:2 FTOH (5.84 ng m?3) was highest among fluorotelomers, followed by those of 10:2 FTOH (1.12 ng m?3), 6:2 FTOH (0.29 ng m?3), and others. Significant correlations among fluorotelomers were observed in collected samples. The association between housing conditions and 8:2 FTOH concentrations showed that samples collected from bed rooms have higher 8:2 FTOH concentrations than those collected from other locations. In addition, samples collected in winter showed lower levels of 8:2 FTOH than those collected in summer. These findings suggest that 8:2 FTOH is the predominant component among fluorotelomers in indoor air, and that there are emission sources of fluorotelomers in indoor environments of the Keihan area. Further investigations into the origins of fluorotelomers are needed to evaluate indoor contamination with fluorotelomers. 相似文献
20.
《Atmospheric environment (Oxford, England : 1994)》2007,41(5):959-973
An indoor air quality model was used to predict dynamic particle mass concentrations based on homogeneous chemical mechanisms and partitioning of semi-volatile products to particles. The ozone–limonene reaction mechanism was combined with gas-phase chemistry of common atmospheric organic and inorganic compounds and incorporated into the indoor air quality model. Experiments were conducted in an environmental chamber to investigate secondary particle formation resulting from ozone/limonene reactions. Experimental results indicate that significant fine particle growth occurs due to the interaction of ozone and limonene and subsequent intermediate by-products. Secondary particle mass concentrations were estimated from the measured particle size distribution. Predicted particle mass concentrations were in good agreement with experimental results—generally within ∼25% at steady-state conditions. Both experimental and predicted results suggest that air exchange rate plays a significant role in determining secondary fine particle levels in indoor environments. Secondary particle mass concentrations are predicted to increase substantially with lower air exchange rates, an interesting result given a continuing trend toward more energy efficient buildings. Lower air exchange rates also shifted the particle size distribution toward larger particle diameters. Secondary particle mass concentrations are also predicted to increase with higher outdoor ozone concentrations, higher outdoor particle concentrations, higher indoor limonene emission rates, and lower indoor temperatures. 相似文献