首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Particle emissions caused by railway traffic have hardly been investigated in the past, due to their obviously minor influence on air quality compared to automotive traffic. In this study, emissions related to particle abrasion from wheels and tracks were investigated next to a busy railway line in Zürich (Switzerland), where trains run nearly exclusively with electrical locomotives. Hourly size-segregated aerosol samples (0.1–1, 1–2.5 and 2.5–10 μm) were collected with a rotating drum impactor (RDI) and subsequently analyzed by synchrotron radiation X-ray fluorescence spectrometry (SR-XRF). In this way, hourly elemental mass concentrations were obtained for chromium, manganese, iron and copper, which are the elements most relevant for railway abrasion. Additionally, daily aerosol filters were collected at the same site as well as at a background site for subsequent analysis by gravimetry and wavelength dispersive XRF (WD-XRF). Railway related ambient air concentrations of iron and manganese were calculated for the coarse (2.5–10 μm) and fine (<2.5 μm) particle fraction by means of a Mn/Fe ratio investigation. The comparison to train type and frequency data showed that 75% and 60% of the iron and manganese mass concentrations related to cargo and passenger trains, respectively, were found in the coarse mode. The railway related iron mass concentration normalized by the train frequency ranges between 10 and 100 ng m−3 h iron in 10 m distance to the tracks, depending on train type. It is estimated that the personal exposure next to a busy railway line above ground is more than a magnitude lower than inside a subway station.  相似文献   

2.
In August 2003 during the anticipated month of the 2008 Beijing Summer Olympic Games, we simultaneously collected PM10 and PM2.5 samples at 8, 100, 200 and 325 m heights up a meteorological tower and in an urban and a suburban site in Beijing. The samples were analysed for organic carbon (OC) and elemental carbon (EC) contents. Particulate matter (PM) and carbonaceous species pollution in the Beijing region were serious and widespread with 86% of PM2.5 samples exceeding the daily National Ambient Air Quality Standard of the USA (65 μg m−3) and the overall daily average PM10 concentrations of the three surface sites exceeding the Class II National Air Quality Standard of China (150 μg m−3). The maximum daily PM2.5 and PM10 concentrations reached 178.7 and 368.1 μg m−3, respectively, while those of OC and EC reached 22.2 and 9.1 μg m−3 in PM2.5 and 30.0 and 13.0 μg m−3 in PM10, respectively. PM, especially PM2.5, OC and EC showed complex vertical distributions and distinct layered structures up the meteorological tower with elevated levels extending to the 100, 200 and 300 m heights. Meteorological evidence suggested that there exist fine atmospheric layers over urban Beijing. These layers were featured by strong temperature inversions close to the surface (<50 m) and more stable conditions aloft. They enhanced the accumulation of pollutants and probably caused the complex vertical distributions of PM and carbonaceous species over urban Beijing. The built-up of PM was accompanied by transport of industrial emissions from the southwest direction of the city. Emissions from road traffic and construction activities as well as secondary organic carbon (SOC) are important sources of PM. High OC/EC ratios (range of 1.8–5.1 for PM2.5 and 2.0–4.3 for PM10) were found, especially in the higher levels of the meteorological tower suggesting there were substantial productions of SOC in summer Beijing. SOC is estimated to account for at least 33.8% and 28.1% of OC in PM2.5 and PM10, respectively, with higher percentages at the higher levels of the tower.  相似文献   

3.
Trace elements and metals in the ultrafine (<0.18 μm) and accumulation (0.18–2.5 μm) particulate matter (PM) modes were measured during the winter season, next to a busy Southern California freeway with significant (∼20%) diesel traffic. Both ambient and concentrated size-segregated impactor samples were taken in order to collect enough mass for chemical analysis. Data at this location were compared to a site located 1 mile downwind of the freeway, which was reflective of urban background. The most abundant trace elements in the accumulation mode detected by inductively coupled plasma mass spectroscopy (ICPMS) were S (138 ng m−3), Na (129 ng m−3), and Fe (89 ng m−3) while S (35 ng m−3) and Fe (35 ng m−3) were the most abundant in the ultrafine mode. The concentrations of several trace elements, including Mg, Al, and Zn, and in particular Ca, Cu, and Pb, did not uniformly increase with size within fine PM, an indication that various roadway sources exist for these elements. Calculation of crustal enrichment factors for the two sites indicates that the freeway traffic contributed to enriched levels of ultrafine Cu, Ba, P and Fe and possibly Ca. The results of this study show that trace elements constitute a small fraction of PM mass in the nanoparticle size range, but these can and should be characterized due to their likely importance to human health.  相似文献   

4.
This paper evaluates the role of Saharan dust advection in the exceeding of the PM10 thresholds in the city of Rome, Italy. To this purpose, a series of observations and model forecasts recorded in the year 2001 are analysed and discussed. Lidar profiles collected over 168 days of the year are employed to both assess the presence and magnitude of Saharan dust layers over the city and to evaluate the depth of the planetary boundary layer. Backtrajectories are used to verify the Saharan origin of the lidar-sounded air masses. Model predictions of the presence of Saharan dust over the area are employed to fill the time gaps between lidar observations. PM10 and carbon monoxide records of both a city background (Villa Ada) and a heavy traffic station (Magna Grecia) are cross-analysed with the dust events record and meteorological data. The analysis shows that: (1) Saharan dust was advected over Rome on about 30% of the days of 2001; (2) mean contribution of Saharan dust transport events to daily PM10 levels was of the order of 20 μg m−3; (3) at the urban background station of Villa Ada, the Saharan contribution caused the surpassing of the maximum number of days in excess of 50 μg m−3 fixed by the current legislation (35 per year). Conversely, at the heavy traffic station of Magna Grecia the Saharan contribution was not determinant at causing the observed large exceeding of that limit, as well as of the maximum yearly average of 40 μg m−3; (4) 25% of the Saharan advection days (of the order of 100/year at Rome) led to a PM10 increase >30 μg m−3, 4% caused an increase >50 μg m−3, thus leading on their own to surpassing the 50 μg m−3 daily limit.  相似文献   

5.
Carbonaceous aerosol particles were observed in a residential area with wood combustion during wintertime in Northern Sweden. Filter samples were analyzed for elemental carbon (EC) and organic carbon (OC) content by using a thermo-optical transmittance method. The light-absorbing carbon (LAC) content was determined by employing a commercial Aethalometer and a custom-built particle soot absorption photometer. Filter samples were used to convert the optical signals to LAC mass concentrations. Additional total PM10 mass concentrations and meteorological parameters were measured. The mean and standard deviation mass concentrations were 4.4±3.6 μg m−3 for OC, and 1.4±1.2 μg m−3 for EC. On average, EC accounted for 10.7% of the total PM10 and the contribution of OC to the total PM10 was 35.4%. Aethalometer and custom-built PSAP measurements were highly correlated (R2=0.92). The hourly mean value of LAC mass concentration was 1.76 μg m−3 (median 0.88 μg m−3) for the winter 2005–2006. This study shows that the custom-built PSAP is a reliable alternative for the commercial Aethalometer with the advantage of being a low-cost instrument.  相似文献   

6.
Aerosol samples were collected using a stacked filter unit (SFU) for PM10-2.0 and PM2.0 size fractions on the platform of a metropolitan underground railway station in downtown Budapest. Temporal variations in the PM10 mass concentration and wind speed and direction were determined with time resolutions of 30 and 4 s using a tapered-element oscillating microbalance (TEOM) and a wind monitor, respectively. Sample analysis involved gravimetry for particulate mass, and particle-induced X-ray emission spectrometry (PIXE) for elemental composition. Diurnal variation of the PM10 mass concentration exhibited two peaks, one at approximately 07:00 h and the other at approximately 17:00 h. The mean±SD PM10 mass concentration for working hours was 155±55 μg m−3. Iron, Mn, Ni, Cu, and Cr concentrations were higher than in outdoor air by factors between 5 and 20, showing substantial enrichment compared to both the average crustal rock composition and the average outdoor aerosol composition. Iron accounted for 40% and 46% of the PM10-2.0 and PM2.0 masses, respectively, and 72% of the PM10 mass was associated with the PM10-2.0 size fraction. The aerosol composition in the metro station (in particular the abundance of the metals mentioned above) is quite different from the average outdoor downtown composition. Mechanical wear and friction of electric conducting rails and bow sliding collectors, ordinary rails and wheels, as well as resuspension, were identified as the primary sources. Possible health implications based on comparison to various limit values and to data available for other underground railways are discussed.  相似文献   

7.
In this paper, results on a PM10 daytime–nighttime measurement campaign carried out in Milan to study the evolution of PM10 concentration and composition in relation to atmospheric dispersion conditions are shown. To account for the evolution of atmospheric dispersion conditions, Radon hourly concentration measurements were performed. The significant correlation between PM10 and 222Rn daytime concentrations evidences the dominant role of atmospheric dispersion in determining the temporal variation of PM10 levels. Whenever 222Rn concentrations accumulate during the night (indicating the formation of nocturnal atmospheric stability conditions), PM10 concentrations are higher than those registered during the daytime before, despite a decrease in emissions from active sources. On the contrary, when 222Rn concentrations do not accumulate during night hours, PM10 levels are lower than those measured during the daytime before.As concerns the average elemental concentrations (in ng m−3), the nighttime–daytime variations are in the range −17% to +37%; during the night, soil-related elements (Al, Si, Ca, Ti) decrease while anthropogenic elements (Zn, Cu, Fe, Pb) increase.A case study concerning a ‘green’ Sunday (when traffic was forbidden from 8 a.m. to 8 p.m.) is also discussed. The difference of PM10 concentration and elemental composition registered during the ‘green’ Sunday daytime and the following nighttime, together with the information on atmospheric dilution power obtained by Radon measurements, allowed the characterisation of the traffic source elemental profile and increased the comprehension of the low effectiveness of some PM10 reduction strategies.  相似文献   

8.
This study examined commuter’s exposure to respirable suspended particulate matters while commuting in public transportation modes. The survey was conducted between October 1999 and January 2000 in Hong Kong. A total of eight public transportation modes, that are bus, tram, public light bus, taxi, ferry, Kowloon–Canton Railway, Mass Transit Railway and Light Rail Transit, were selected in the study. They were grouped into four categories: (T1) railway transport; (T2) non-air-conditioned roadway transport; (T3) air-conditioned roadway transport and (T4) marine transport. Both PM10 and PM2.5 levels were investigated. The results indicate that the particulate level is greatly affected by the mode of transport as well as the ventilation system of the transport. The overall average PM10 concentration level in T2 (147 μg m−3) is the highest and is followed by T4 (81 μg m−3) and T3 (65 μg m−3). The PM10 level in T1 (50 μg m−3) is the lowest. Notably, the commuter exposure in tram (175 μg m−3) is the highest among all the monitored commuting modes. Commuting modes such as railway and air-conditioned vehicle are recommended as a substitute for non-air-conditioned vehicle. The PM2.5 to PM10 ratio in transports ranged from 63% to 78%. Higher PM2.5 to PM10 ratio is found in vehicles with air-conditioning system. For the double deck vehicle, higher PM10 level has resulted in the lower deck. The average upper-deck to lower-deck PM10 ratio is 0.836, 0.751 and 0.738 in air-conditioned bus, non-air-conditioned bus and non-air-conditioned tram, respectively. Typical concentration profiles in different transports are also presented.  相似文献   

9.
PM10 aerosols at McMurdo Station, Antarctica were sampled continuously during the austral summers of 1995–1996 and 1996–1997. PM10 (particles with aerodynamic diameters less than 10 μm) mass concentrations at Hut Point, located less than 1 km from downtown McMurdo, averaged 3.4 μg m−3, more than an order of magnitude lower than the USEPA annual average National Ambient Air Quality Standard (NAAQS) of 50 μg m−3. Concentrations of methanesulfonate and nitrate were similar to those measured at other Antarctic coastal sites. Non-sea-salt sulfate (NSS) concentrations on Ross Island were higher than those found at other coastal locations. The average elemental carbon concentration (129 ng m−3) downwind of the station was two orders of magnitude higher than those measured at remote coastal and inland Antarctic sites during summer. Average sulfur dioxide concentrations (746 ng m−3) were 3–44 times higher than those reported for coastal Antarctica. Concentrations of Pb and Zn were 17 and 46 times higher than those reported for the South Pole. A methanesulfonate to biogenic sulfate ratio (R) of 0.47 was derived that is consistent with the proposed temperature dependence of R.  相似文献   

10.
The analysis of PM10 and TSP levels recorded in rural areas from Southern and Eastern Spain (1996–1999) shows that most of the PM10 and TSP peak events are simultaneously recorded at monitoring stations up to 1000 km apart. The study of the atmospheric dynamics by back-trajectory analysis and simulations with the SKIRON Forecast System show that these high PM10 and TSP events occur when high-dust Saharan air masses are transported over the Iberian Peninsula. In the January–June period, this dust transport is mainly caused by cyclonic activity over the West or South of Portugal, whereas in the summer period this is induced by anticyclonic activity over the East or Southeast Iberian Peninsula. Most of the Saharan intrusions which exert a major influence on the particulate levels occur from May to September (63%) and in January and October. In rural areas in Northeast Spain, where the PM10 annual mean is around 18 μg PM10 m−3, the Saharan dust accounts for 4–7 annual daily exceedances of the forthcoming PM10-EU limit value (50 μg PM10 m−3 daily mean). Higher PM10 background levels are recorded in Southern Spain (30 μg PM10 m−3 as annual mean for rural areas) and very similar values are recorded in industrial and urban areas. In rural areas in Southern Spain, the Saharan dust events accounts for 10–23 annual daily exceedances of the PM10 limit value, a high number when compared with the forthcoming EU standard, which states that the limit value cannot be exceeded more than 7 days per year. The proportion of Sahara-induced exceedances with respect to the total annual exceedances is discussed for rural, urban and industrial sites in Southern Spain.  相似文献   

11.
Sampling and analysis of carbonaceous compounds in particulate matter presents a number of difficulties related to artefacts during sampling and to the distinction between organic (OC) and elemental carbon (EC) during analysis. Our study reports on a comparative analysis of OC, EC and WSOC (water-soluble organic carbon) concentrations, as well as sampling artefacts, for PM2.5 aerosol in three European cities (Amsterdam, Barcelona and Ghent) representing Southern and Western European urban environments. Comparability of results was ensured by using a single system for sample analysis from the different sites. OC and EC concentrations were higher in the vicinity of roads, thus having higher levels in Amsterdam (3.9–6.7 and 1.7–1.9 μg m−3, respectively) and Barcelona (3.6–6.9 and 1.5–2.6 μg m−3) than in Ghent (2.7–5.4 and 0.8–1.2 μg m−3). A relatively larger influence of secondary organic aerosols (SOA), as deduced from a larger OC/EC ratio, was observed in Ghent. In absolute sense, WSOC concentrations were similar at the three sites (1.0–2.3 μg m−3). Positive artefacts were higher in Southern (11–16% of the OC concentration in Barcelona) than in Western Europe (5–12% in Amsterdam, 5–7% in Ghent). During special episodes, the contribution of carbonaceous aerosols from non-local sources accounted for 67–69% of the OC concentration in Western Europe, and for 44% in Southern Europe.  相似文献   

12.
A study of carbonaceous particulate matter (PM) was conducted in the Middle East at sites in Israel, Jordan, and Palestine. The sources and seasonal variation of organic carbon, as well as the contribution to fine aerosol (PM2.5) mass, were determined. Of the 11 sites studied, Nablus had the highest contribution of organic carbon (OC), 29%, and elemental carbon (EC), 19%, to total PM2.5 mass. The lowest concentrations of PM2.5 mass, OC, and EC were measured at southern desert sites, located in Aqaba, Eilat, and Rachma. The OC contribution to PM2.5 mass at these sites ranged between 9.4% and 16%, with mean annual PM2.5 mass concentrations ranging from 21 to 25 ug m?3. These sites were also observed to have the highest OC to EC ratios (4.1–5.0), indicative of smaller contributions from primary combustion sources and/or a higher contribution of secondary organic aerosol. Biomass burning and vehicular emissions were found to be important sources of carbonaceous PM in this region at the non-southern desert sites, which together accounted for 30%–55% of the fine particle organic carbon at these sites. The fraction of measured OC unapportioned to primary sources (1.4 μgC m?3 to 4.9 μgC m?3; 30%–74%), which has been shown to be largely from secondary organic aerosol, is relatively constant at the sites examined in this study. This suggests that secondary organic aerosol is important in the Middle East during all seasons of the year.  相似文献   

13.
Biomass quantities at three different sites in tropical moist mixed secondary deciduous forests before and after burning have been quantified in the forest patches cleared for shifting cultivation purposes. The main objective of the experiments was to study the spatial variability in the amount of biomass burnt and the contribution of different components viz., bole, branch, and mixed leaf litter in the burning process affecting the combustion factors. Species composition at the three sites varied with respect to each other. The total density of species before burning at the three sites for more than 10 cm diameter were found to be 3192 (site 1), 1194 (site 2) and 1444 (site 3) stems/area, respectively. Analysis of the results from girth-class and density relationships suggests that nearly 80% of the stems occurred in the range from 10–40 cm girth for site one, 64.2% in 10–55 cm girth class for the site two and more than 80% of stems in 10–40 cm girth class for the site three, indicating very poor and secondary nature of the forest. The fire intensity is found to be high for site one with 60 847 kJ s−1 m−1, when compared to 31 086 and 42 789 kJ s−1 m−1 for second and third sites, respectively. The values are comparatively higher than the mean value of 2566 kJ s−1 m−1 reported for savanna fires. The individual combustion completeness suggested that among the different components of biomass, branch material with less than 10 cm and upto 5 cm dbh contributed to more than 60% of combustion. Mixed leaf litter contributed to about more than 50% of individual combustion completeness at all the sites, with third site having the highest (84%). The contribution of dry biomass material having more than 70 cm diameter is found to be very low indicating that most of the trunks were burnt superficially. The overall combustion completeness suggested that mixed leaf litter and branch material contributed to most of the combustion. Of all the three sites, site three had been found to be having highest combustion completeness of about 30.04% when compared to 20.18% and 16.1% for first and second sites, respectively. In the study, comparison of combustion factors for different vegetation types has also been made.  相似文献   

14.
From 1 May to 25 May 2001, the BAB II campaign was carried out at the motorway BAB (656) near Heidelberg. Atmospheric concentrations of particulate matter and gases were measured together with the meteorological conditions. This paper is focused on the particulate matter measured upwind and downwind from the motorway at ground level. In order to determine the source contribution from the motorway traffic, it was necessary to measure upwind and downwind simultaneously due to variations in background concentrations. The particle number contribution from the motorway was found to be 35,000 particles cm−3 for particles with diameters close to 20 nm and 5000 particles cm−3 for particles with diameters close to 70 nm. Bimodal size distributions were observed on the downwind side, whereas the upwind side showed unimodal size distributions. For particulate mass, it can be estimated that the contribution from the motorway to the PM1 concentrations is in a range 0.6–1.3 μg m−3 for the chosen measurement sites approximately 60 m from the road at a height of 6 m. The soot measurements showed diurnal variation; however, the upwind downwind difference was not measured. Correlation factors showed good correlation between total particle number and number of particles with diameters below 80 nm, CO and NO. There was no correlation between particle number and PM10, which is due to the observation that particle number was dominated by the 20 nm particles.  相似文献   

15.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were measured in bulk deposition at three Danish rural forest sites with a mutual maximum distance of 450 km. At one of the forest sites concentrations in the ambient atmosphere were sampled from a 12 m high tower. Sampling was carried out within a period of 3 years with sampling intervals of 1–2 months. Mean bulk deposition fluxes were 1 ng m−2 yr−1 I-TEQ and deviated less than 30% between the sites. Yearly average PCDD/F concentrations in the atmosphere were 24 fg m−3 I-TEQ with maximum values in the winter period. During winter months atmospheric concentrations of PCDD/F and oxidized sulphur compounds showed a positive correlation, furthermore seasonal bulk deposition showed correlation between PCDD/F and sulphate.  相似文献   

16.
A detailed study of resuspension of 1.85 μm MMAD silica particles from five horizontal layers within a small scale spruce canopy was carried out in a wind tunnel in which saplings were exposed to a constant free stream wind speed of 5 m s−1. This provided quantitative estimates of the potential for a tree canopy contaminated with an aerosol deposit to provide (i) an airborne inhalation hazard within the forest environment and (ii) a secondary source of airborne contamination after an initial deposition event. Resuspension occurred with a flux of 1.05×10−7 g m−2 s−1 from spruce saplings initially contaminated at a level of 4.1×10−2 g m−2. An average resuspension rate (Λ) of 4.88×10−7 s−1 was obtained for the canopy as a whole. Values of Λ were significantly different (ANOVA, p<0.001) between canopy layers and Λ was markedly greater at the top of the canopy than lower down although there was a slight increase in Λ at the base of the canopy. The resuspended silica particles deposited onto the soil surface at an average rate of about 5.3×10−8 μg cm−2 s−1. It is concluded that resuspension under wind velocities similar to that used in the reported experiments is likely to pose a relatively small inhalation hazard to humans and a relatively minor source of secondary contamination of adjacent areas. Furthermore, resuspension rates are likely to diminish rapidly with time. The results are discussed in relation to the growing interest in the tree planting schemes in urban areas to reduce the impacts of air pollution.  相似文献   

17.
The influence of two intensive low-altitude atmospheric-dust intrusions on the activity levels of 137Cs and 40K as well as atmospheric particle matter (PM10) concentrations in the lower atmosphere of the Canary Islands are analysed here. These two events took place at the beginning of January 2002 and March 2004, respectively. 3D atmospheric back-trajectories indicated that the main source of dust material involved in the considered atmospheric intrusions came from NW Africa. A consequence of these dust intrusions was the major increase of PM10 concentrations in the lower atmosphere. Both episodes were characterised by having weekly averages of PM10 concentration surpassing 150 μg m−3, higher than the daily PM10 limit value established by the EC/1999/30 directive for PM10 from 2005. Similarly, during these two events, both 137Cs and 40K activities increased by a factor of 6 and 13 as well as 13 and 14, respectively, over the basal values calculated for each radionuclide and time period (0.59±0.02 and 0.88±0.07 μBq m−3 as well as 12±6 and 24±8 μBq m−3).  相似文献   

18.
During the month of August 2004, the size-resolved number concentration of water-insoluble aerosols (WIA) from 0.25 to 2.0 μm was measured in real-time in the urban center of Atlanta, GA. Simultaneous measurements were performed for the total aerosol size distribution from 0.1 to 2.0 μm, the elemental and organic carbon mass concentration, the aerosol absorption coefficient, and the aerosol scattering coefficient at a dry (RH=30%) humidity. The mean aerosol number concentration in the size range 0.1–2.0 μm was found to be 360±175 cm−3, but this quantity fluctuated significantly on time scales of less than one hour and ranged from 25 to 1400 cm−3 during the sample period. The mean WIA concentration (0.25–2.0 μm) was 13±7 cm−3 and ranged from 1 to 60 cm−3. The average insoluble fraction in the size range 0.25–2.0 μm was found to be 4±2.5% with a range of 0.3–38%. The WIA population was found to follow a consistent diurnal pattern throughout the month with concentration maxima concurring with peaks in vehicular traffic flow. WIA concentration also responded to changes in meteorological conditions such as boundary layer depth and precipitation events. The temporal variability of the absorption coefficient followed an identical pattern to that of WIA and ranged from below the detection limit to 55 Mm−1 with a mean of 8±6 Mm−1. The WIA concentration was highly correlated with both the absorption coefficient and the elemental carbon mass concentration, suggesting that WIA measurements are dominated by fresh emissions of elemental carbon. For both the total aerosol and the WIA size distributions, the maximum number concentration was observed at the smallest sizes; however the WIA size distribution also exhibited a peak at 0.45 μm which was not observed in the total population. Over 60% of the particles greater than 1.0 μm were observed to be insoluble in the water sampling stream used by this instrumentation. Due to the refractive properties of black carbon, it is highly unlikely that these particles could be composed of elemental carbon, suggesting a crustal source for super-micron WIA.  相似文献   

19.
PM10 levels of the mineral components Si, Al, Fe, Ca, Mg and some trace metals were measured at three different sites in the urban area of Vienna (Austria). Observed trace metal concentrations varied between less than 0.1 ng m?3 (Cd) and approximately 200 ng m?3 (Zn), mineral components showed enhanced concentrations ranging from 0.01 μg m?3 (Ca) to 16.3 μg m?3 (Si). The contribution of the respective mineral oxides to PM10 mass concentrations accounted on average for 26.4 ± 16% (n = 1090) of the PM10 mass, with enhanced rates in spring and autumn (monthly averages of up to 40%) and decreased contributions in the cold season (monthly averages below 10%). The atmospheric occurrence of Al, Ti and Sr could be assigned to crustal sources, whereas for the elements Ba, Ca, Fe, Mg, Mn and V an increased contribution of non-crustal origin was observed. PM10 levels of As, Cd, Co, Cr, Cu, Ni, Pb, Sb, Sn and Zn were predominantly derived from man-made emissions. Intersite comparison indicated that urban PM10 mass concentrations and PM10 levels of As, Pb and Zn were predominantly influenced from the transport of aerosols from outside into the city, whereas for the elements Ba, Mg, Ca, Cu and Fe a distinctly increased impact of local emissions was observed. The contribution of these urban emissions to total PM10 concentrations was estimated by calculating the so-called “urban impact”, which was found to be 32.7 ± 18% (n = 392) in the case of PM10 mass concentrations. The investigated elements accounted on average for 31.3 ± 19% (n = 392) of the observed PM10 mass increase. The mean values for the “urban impacts” of individual elements varied between 25.5% (As) and 77.0% (Ba).  相似文献   

20.
A portable radiance research nephelometer was used to measure the variation in woodsmoke pollution in Armidale (a small town of 22,000 people), New South Wales, Australia, on 14 winter nights in 1996. Winter nights are characterised by inversions that trap the air within the valley and reduce winds to very low speeds (averaging 0.15 m s−1). Pollution varied considerably with location. Mean scattering coefficients (bsp/10 km) for 14 measurement nights ranged from less than 1.0 on the undeveloped fringes of the city to 8.7, the latter representing a 14-night average of 200 μg m−3 of PM2.5. Pollution was generally highest in the residential areas on either side of the valley, where the smoke was generated, rather than the low-lying central creeklands. In places, average pollution levels increased 4-fold within 41 m. The correlation between nephelometer and gravimetric pollution measurements ranged 0.95–0.99. The presence of large, sudden but repeatable changes in air pollution, and high correlations between nephelometer and gravimetric measurements, indicate that mobile pollution monitoring devices provide a useful and accurate estimate of spatial variability. Estimated exposure for the town as a whole was 1.02 for the 6 months from April to September, 0.25 in October as heater use declines, and 0.12 in normal summer months. For comparison, published 25th, 50th and 75th percentiles of the distribution of nephelometer coefficients in Sydney were 0.15, 0.24 and 0.37, respectively. Thus annual exposure to PM2.5 pollution in Armidale from woodsmoke is more than double that from all sources in Sydney, a city of 4 million. Overseas estimates of 6% increased mortality for each additional 10 μg m−3 of PM2.5 suggest that wood heaters in Armidale may increase mortality in Armidale by about 7%, with estimated cost of about $4270 per woodheater per year. Alternative cheap and environmentally friendly methods of keeping houses warm in winter, such as solar heating, should therefore be developed.  相似文献   