首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Factors affecting the concentrations of PM10 in central Taiwan   总被引:1,自引:0,他引:1  
Kuo CY  Chen PT  Lin YC  Lin CY  Chen HH  Shih JF 《Chemosphere》2008,70(7):1273-1279
In this study, the synoptic weather types that have high probability and low probability of producing PM10 episode are referred to as HPE and LPE, respectively. Multiple linear regressions analysis showed that NO2 was the most important contributor (35.61%) to the concentrations of PM10 for HPE weather. For LPE weather, the season factor had the greatest contribution (48.11%) to the concentrations of PM10. Using the correlation coefficients between the concentrations of PM10 and SO2 or NO2 on HPE and LPE to calculate the increase of PM10 from LPE to HPE, we found that the increase of PM10 owing to the increase of SO2 and NO2 from LPE to HPE was 12.93microg/m3 which was about 51% of the total amount of PM10 increased from LPE to HPE. Results of factor analysis showed that the first component could be attributed to the result of local pollution especially for the weather patterns of types P3 and P6, while the secondary component for the weather patterns of types P1 and P4 can be attributed to the long-range transport of SO2 pollutants from China.  相似文献   

3.
During the last 10 years, high atmospheric concentrations of airborne particles recorded in the Mexico City metropolitan area have caused concern because of their potential harmful effects on human health. Four monitoring campaigns have been carried out in the Mexico City metropolitan area during 2000-2002 at three sites: (1) Xalostoc, located in an industrial region; (2) La Merced, located in a commercial area; and (3) Pedregal, located in a residential area. Results of gravimetric and chemical analyses of 330 samples of particulate matter (PM) with an aerodynamic diameter less than 2.5 microm (PM2.5) and PM with an aerodynamic diameter less than 10 microm (PM10) indicate that (1) PM2.5/PM10 average ratios were 0.42, 0.46, and 0.52 for Xalostoc, La Merced, and Pedregal, respectively; (2) the highest PM2.5 and PM10 concentrations were found at the industrial site; (3) PM2.5 and PM10 concentrations were lower at nighttime; (4) PM2.5 and PM10 spatial averages concentrations were 35 and 76 microg/m3, respectively; and (5) when the PM2.5 standard was exceeded, nitrate, sulfate, ammonium, organic carbon, and elemental carbon concentrations were high. Twenty-four hour averaged PM2.5 concentrations in Mexico City and Sao Paulo were similar to those recorded in the 1980s in Los Angeles. PM10 concentrations were comparable in Sao Paulo and Mexico City but 3-fold lower than those found in Santiago.  相似文献   

4.
An integrated approach to identify the origin of PM10 exceedances   总被引:1,自引:1,他引:0  

Purpose

This study was aimed to the development of an integrated approach for the characterization of particulate matter (PM) pollution events in the South of Italy.

Methods

PM10 and PM2.5 daily samples were collected from June to November 2008 at an urban background site located in Bari (Puglia Region, South of Italy). Meteorological data, particle size distributions and atmospheric dispersion conditions were also monitored in order to provide information concerning the different features of PM sources.

Results

The collected data allowed suggesting four indicators to characterize different PM10 exceedances. PM2.5/PM10 ratio, natural radioactivity, aerosol maps and back-trajectory analysis and particle distributions were considered in order to evaluate the contribution of local anthropogenic sources and to determine the different origins of intrusive air mass coming from long-range transport, such as African dust outbreaks and aerosol particles from Central and Eastern Europe. The obtained results were confirmed by applying principal component analysis to the number particle concentration dataset and by the chemical characterization of the samples (PM10 and PM2.5).

Conclusions

The integrated approach for PM study suggested in this paper can be useful to support the air quality managers for the development of cost-effective control strategies and the application of more suitable risk management approaches.  相似文献   

5.
PM10 measurements were started in November 1992 at Melpitz site. The mean PM10 concentration in 1993 was 38 μg m?3 in the summer season (May until October) and about 44 μg m?3 in the winter season (November until April). The mean PM10 level decreased until 1999 and varies now in ranges from 20–34 μg m?3 to 17–24 μg m?3 (minimum and maximum mean values for 1999–2008) in winter and summer seasons, respectively. High volume filter samples of particles PM10, PM2.5 and PM1 were characterized for mass, water-soluble ions, organic and elemental carbon from 2004 until 2008. The percentage of PM2.5 in PM10 varies between summer (71.6%) and winter seasons (81.9%). Mean concentrations of PM10, PM2.5 and PM1 in Melpitz were 20, 15, and 13 μg m?3 in 2004, 22, 18, and 13 μg m?3 in 2005, 24, 19, and 12 μg m?3 in 2006 and 22, 17, and 12 μg m?3 in 2007, respectively. In the four winters the rural background concentration PM10 at Melpitz exceeded the daily 50 μg m?3 limit for Europe on 8, 8, 7 and 6 days, respectively.Findings for a simple two-sector-classification of the samples (May 2004 until April 2008) using 96-h backward trajectories for the identification of source regions are: Air masses were transported most of time (60%) from the western sector and secondly (17%) from the eastern sector. The lowest daily mean mass concentration PM10 were found during western inflow in summer (17 μg m?3) containing low amounts of sulphate (2.4 μg m?3), nitrate (1.7 μg m?3), ammonium (1.1 μg m?3) and TC (3.7 μg m?3). In opposite the highest mean mass concentration PM10 was found during eastern inflow in winter (35 μg m?3) with high amounts of sulphate (6.1 μg m?3), nitrate (5.4 μg m?3), ammonium (3.8 μg m?3) and TC (9.4 μg m?3). An estimation of secondary formed OC (SOA) shows 0.8–0.9 μg m?3 for air masses from West and 2.1–2.2 μg m?3 from East. The seasonal difference can be neglected.The half-hourly measurements of the particle mass concentration PM10 evaluated as mean daily courses using a TEOM® show low values (14–21 μg m?3) in summer and winter for air masses transported from West and the highest concentrations (31–38 μg m?3) in winter for air masses from East.The results demonstrate the influence of meteorological parameters on long-range transport, secondary particle mass formation and re-emission which modify mass concentration and composition of PM10, PM2.5 and PM1. Melpitz site is located in the East of Germany faraway from strong local anthropogenic emissions (rural background). Therefore, this site is suitable for investigation of the influence of long-range transport of air pollution in continental air masses from the East with source regions inside and outside of the European Union.  相似文献   

6.
It will be many years before the recently deployed network of fine particulate matter with an aerodynamic diameter less than 2.5 microm (PM2.5) Federal Reference Method (FRM) samplers produces information on nonattainment areas, trends, and source impacts. However, data on PM2.5 and its major constituents have been routinely collected in California for the past 20 years. The California Air Resources Board operated as many as 20 dichotomous (dichot) samplers for PM2.5 and coarse PM (PM10-2.5). The California Acid Deposition Monitoring Program (CADMP) collected 12-h-average PM2.5 and PM10 from 1988 to 1995 at ten urban and rural sites and 24-h-average PM2.5 at five urban sites since 1995. Beginning in 1994, the Children's Health Study collected 2-week averages of PM2.5 in 12 communities in southern California using the Two-Week Sampler (TWS). Comparisons of collocated samples establish relationships between the dichot, CADMP, and TWS samplers and the 82-site network of PM2.5 FRM samplers deployed since 1999 in California. PM mass data from the different monitoring programs have modest to high correlation to FRM mass data, fairly small systematic biases and negative proportional biases ranging from 7 to 22%. If the biases are taken into account, all of the programs should be considered comparable with the FRM program. Thus, historical data can be used to develop long-term PM trends in California.  相似文献   

7.
Between November 1995 and October 1996, particulate matter concentrations (PM10 and PM2.5) were measured in 25 study areas in six Central and Eastern European countries: Bulgaria, Czech Republic, Hungary, Poland, Romania and Slovak Republic. To assess annual mean concentration levels, 24-h averaged concentrations were measured every sixth day on a fixed urban background site using Harvard impactors with a 2.5 and 10 μm cut-point. The concentration of the coarse fraction of PM10 (PM10−2.5) was calculated as the difference between the PM10 and the PM2.5 concentration. Spatial variation within study areas was assessed by additional sampling on one or two urban background sites within each study area for two periods of 1 month. QA/QC procedures were implemented to ensure comparability of results between study areas. A two to threefold concentration range was found between study areas, ranging from an annual mean of 41 to 98 μg m−3 for PM10, from 29 to 68 μg m−3 for PM2.5 and from 12 to 40 μg m−3 for PM10−2.5. The lowest concentrations were found in the Slovak Republic, the highest concentrations in Bulgaria and Poland. The variation in PM10 and PM2.5 concentrations between study areas was about 4 times greater than the spatial variation within study areas suggesting that measurements at a single sampling site sufficiently characterise the exposure of the population in the study areas. PM10 concentrations increased considerably during the heating season, ranging from an average increase of 18 μg m−3 in the Slovak Republic to 45 μg m−3 in Poland. The increase of PM10 was mainly driven by increases in PM2.5; PM10−2.5 concentrations changed only marginally or even decreased. Overall, the results indicate high levels of particulate air pollution in Central and Eastern Europe with large changes between seasons, likely caused by local heating.  相似文献   

8.
The Aerodynamic Particle Sizer (APS 3321, TSI, Inc., Shoreview, MN) rapidly measures particle number concentration by size from 0.5 to 20 microm. This work used simple assumptions for particle shape factor and density to estimate ambient coarse mode particulate matter, PM10-2.5, from APS number concentration data. This estimate was compared with that measured with time-integrated, filter-based federal reference method (FRM) samplers in four U.S. field studies: two in Phoenix, AZ; one in Gary, IN; and one in Riverside, CA. Near one-to-one agreement and a strong linear relationship were observed between APS-estimated and FRM-measured PM10-2.5 in the first Phoenix, AZ study (slope = 0.90, R2 = 1.00); the second Phoenix, AZ study (slope = 0.99, R2 = 0.99); and the Riverside, CA study (slope = 1.00, R2 = 0.84). In the Gary, IN study, PM10-2.5 estimates made with data from the APS tended to be less than that measured with the FRM samplers (slope = 0.57), but the linear relationship between the two methods was still strong (R2 = 0.90). Particle-bound water associated with wet atmospheric conditions may account for these differences. Additional testing is required to resolve this issue.  相似文献   

9.
Geographic and temporal variations in the concentration and composition of particulate matter (PM) provide important insights into particle sources, atmospheric processes that influence particle formation, and PM management strategies. In the nonurban areas of California, annual-average PM2.5 and PM10 concentrations range from 3 to 10 microg/m3 and from 5 to 18 microg/m3, respectively. In the urban areas of California, annual-averages for PM2.5 range from 7 to 30 microg/m3, with observed 24-hr peaks reaching levels as high as 160 microg/m3. Within each air basin, exceedances are a mixture of isolated events as well as periods of elevated PM2.5 concentrations that are more prolonged and regional in nature. PM2.5 concentrations are generally highest during the winter months. The exception is the South Coast Air Basin, where fairly high values occur throughout the year. Annual-average PM2.5 mass, as well as the concentrations of major components, declined from 1988 to 2000. The declines are especially pronounced for the sulfate (SO4(2-)) and nitrate (NO3-) components of PM2.5 and PM10) and correlate with reductions in ambient levels of oxides of sulfur (SOx) and oxides of nitrogen (NOx). Annual averages for PM10-2.5 and PM10 exhibited similar downwind trends from 1994 to 1999, with a slightly less pronounced decrease in the coarse fraction.  相似文献   

10.
In this work we present a detailed study of atmospheric PM10 pollution in Andalusia (Southern Spain) based on geochemical maps. The study includes determination of PM10 levels and bulk chemical composition with samples from 17 representative monitoring stations (rural, urban background, traffic hot spot, and urban zones with industrial influence) during 2007. The knowledge of background levels and concentrations of relevant chemical compounds and elements allows the quantification of the main sources of pollution in relevant cities and sites of ecological interest.In comparison to other stations in Spain and mainland Europe, PM10 in Andalusia is characterized by high levels of crustal matter and secondary inorganic components (SIC). This has been attributed to the following causes: 1) High road traffic and industrial emissions, 2) High frequency of North African air mass outbreaks contributing between 3 and 4 μg m?3 in western Andalusia and 4–7 μg m?3 in eastern Andalusia, and 3) Climate factors such as low rainfall, dry soils favouring resuspension, and high photochemical activity.Atmospheric particulate matter in urban areas located in the vicinity of industrial estates is enriched in secondary inorganic compounds and metals. Three main hot spots have been identified according their high trace element concentrations: Huelva (As, Cu, Zn, Se, and Bi), Strait of Gibraltar (V, Ni, Cr, and Co) and Bailén (V and Ni). The transport of pollutants from cities and industrial estates to areas of ecological interest (e.g. Doñana National Park) has been found to cause the increase in background levels in a number of trace elements (e.g. As) in the air. An important outcome of this study is that geochemical maps of atmospheric matter are a powerful tool for illustrating spatial variation patterns of geochemical components and identifying specific pollution hot spots.  相似文献   

11.
The particulate matter (PM) concentration and composition, the PM10, PM2.5, PM1 fractions, were studied in the urban area of Genoa, a coastal town in the northwest of Italy. Two instruments, the continuous monitor TEOM and the sequential sampler PARTISOL, were operated almost continuously on the same site from July 2001 to September 2004. Samples collected by PARTISOL were weighted to obtain PM concentration and then analysed by PIXE (particle induced X-ray emission) and by ED-XRF (energy dispersion X-ray fluorescence), obtaining concentrations for elements from Na to Pb. Some of the filters used in the TEOM microbalance were analysed by ED-XRF to calculate Pb concentration values averaged over 7-30 d periods.  相似文献   

12.
使用β射线法在线监测仪连续监测了贵阳市白云区PM_(10)和PM_(2.5)浓度,分析了2014年6月1日—12月31日7个月内PM_(10)、PM_(2.5)的浓度水平、时变规律和PM_(2.5)/PM_(10)的变化情况。结果表明,监测时段内PM_(10)和PM_(2.5)的日均浓度平均值分别为76.8μg/m~3和40.0μg/m~3,均达到国家二级标准;浓度超标的天数占总观测天数的5.1%和9.3%,属污染轻微的地区。PM_(2.5)/PM_(10)在25.3%~78.8%之间周期性波动,平均值为52.1%。PM_(10)和PM_(2.5)的浓度变化具有很好的正相关性(r=0.919 8,p0.000 1);日均值在7个月中呈现明显的周期性变化,各月相对稳定,12月的PM_(10)和PM_(2.5)浓度最高且变化最为剧烈,6月最为平缓。PM_(10)和PM_(2.5)浓度小时变化总体上呈双峰型分布,最高值出现在出现在09:00—10:00和19:00—21:00前后,最低值出现在14:00—17:00之间。  相似文献   

13.
The purpose of the present study is to analyze the elemental composition and the concentrations of PM10 and PM2.5 in the Guaíba Hydrographic Basin with HV PM10 and dichotomous samplers. Three sampling sites were selected: 8° Distrito, CEASA and Charqueadas. The sampling was conducted from October 2001 to December 2002. The mass concentrations of the samplers were evaluated, while the elemental concentrations of Si, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu and Zn were determined using the Particle-Induced X-ray Emission (PIXE) technique. Factor Analysis and Canonical Correlation Analysis were applied to the chemical and meteorological variables in order to identify the sources of particulate matter. Industrial activities such as steel plants, coal-fired power plants, hospital waste burning, vehicular emissions and soil were identified as the sources of the particulate matter. Concentration levels higher than the daily and the annual average air quality standards (150 and 50 μg m−3, respectively) set by the Brazilian legislation were not observed.  相似文献   

14.
In Brazil, sugarcane fields are often burned to facilitate manual harvesting, and this burning causes environmental pollution from the large amounts of soot released into the atmosphere. This material contains numerous organic compounds such as PAHs. In this study, the concentrations of PAHs in two particulate-matter fractions (PM2.5 and PM10) in the city of Araraquara (SE Brazil, with around 200,000 inhabitants and surrounded by sugarcane plantations) were determined during the sugarcane harvest (HV) and non-harvest (NHV) seasons in 2008 and 2009. The sampling strategy included four campaigns, with 60 samples in the NHV season and 220 samples in the HV season. The PM2.5 and PM10 fractions were collected using a dichotomous sampler (10 L min?1, 24 h) with Teflon? filters. The filter sets were extracted (ultrasonic bath with hexane/acetone (1:1 v/v)) and analyzed by HPLC/Fluorescence. The median concentration for total PAHs (PM2.5 in 2009) was 0.99 ng m?3 (NHV) and 3.3 ng m?3 (HV). In the HV season, the total concentration of carcinogenic PAHs (benz(a)anthracene, benzo(b)fluoranthene, benzo(k)fluoranthene, and benzo(a)pyrene) was 5 times higher than in the NHV season. B(a)P median concentrations were 0.017 ng m?3 and 0.12 ng m?3 for the NHV and HV seasons, respectively. The potential cancer risk associated with exposure through inhalation of these compounds was estimated based on the benzo[a]pyrene toxic equivalence (BaPeq), where the overall toxicity of a PAH mixture is defined by the concentration of each compound multiplied by its relative toxic equivalence factor (TEF). BaPeq median (2008 and 2009 years) ranged between 0.65 and 1.0 ng m?3 and 1.2–1.4 ng m?3 for the NHV and HV seasons, respectively. Considering that the maximum permissible BaPeq in ambient air is 1 ng m?3, related to the increased carcinogenic risk, our data suggest that the level of human exposure to PAHs in cities surrounded by sugarcane crops where the burning process is used is cause for concern.  相似文献   

15.
A comprehensive field assessment has been made of the measurement performance of PM10 inlets. Both precision and comparability are approximately 4 percent, complying well with the requirements of the proposed Federal Reference Method (FRM). Fluctuations in sampling efficiency play a dominant role. Hence, both comparability and precision can be interpreted in terms of changes in the 50 percent cutoff diameter D50. In this way a D50 performance of about 0.7 μm is deduced, clearly within the proposed FRM requirement of D50 = 10 ± 1 μm. There exists no fixed linear relationship between PM10 and TSP (total suspended particulate matter): different average situations yield different regression coefficients (Western Europe: 0.7 and USA: 0.5). Furthermore, there are different conversion factors, representative of average (0.5-0.7) or episodic situations of high concentration levels (0.8-0.9). Hence, TSP air quality standards should not be replaced by PM10 ones simply by using the regression results from various national studies because this could yield unequal stringent PM10 standards.  相似文献   

16.
分析了2015年南京市PM2.5和PM10的浓度特征和大致来源类型。PM2.5和PM10的年均浓度分别为56.6 μg·m-3和96.5 μg·m-3,污染水平较高。颗粒物浓度的季节变化特征一致:冬 > 春 > 秋 > 夏;PM2.5的日变化呈"单峰单谷"型,而PM10的呈"单峰双谷"型。颗粒物浓度在城区高于郊区;植被茂盛区域的浓度较低。对PM2.5/PM10而言,比值在冬季和梅雨期较大,分别受取暖和降水的影响;比值在春季和夏末秋初较小,分别受沙尘和秸秆焚烧的影响。PM2.5多为二次颗粒物,PM10多为一次颗粒物;固定污染源对PM2.5的间接贡献和对PM10的直接贡献较移动污染源而言更大。  相似文献   

17.
天津冬季PM2.5与PM10中有机碳、元素碳的污染特征   总被引:2,自引:0,他引:2  
研究了天津冬季PM2.5和PM10中碳成分的污染特征.结果表明,天津冬季PM2.5和PM10的平均质量浓度分别为(124.4±60.9)、(224.6±131.2)μg/m3;总碳(TC)、有机碳(OC)与元素碳(EC)在PM2.5中的平均质量分数比在PM10中分别高出5.0%、3.6%、1.2%;PM2.5中OC、EC的相关系数较高,为0.95,表明OC、EC的来源相对简单,可能主要反应了燃煤和机动车尾气的贡献.OC/EC的平均值在PM2.5和PM10中分别为3.9、4.9.次生有机碳(SOC)在PM2.55和PM10中的平均质量浓度分别为14.9、23.4/μg/m3,分别占OC的48.5%(质量分数,下同)、49.8%,OC/EC较高可能主要与直接排放源有关;PM2.5中的OC1与OC2的比例明显高于PM10,而聚合碳(OPC)的比例又低于PM10,同时PM2.5与PM10中的EC1含量均较高,表明天津冬季燃煤取暖和机动车尾气是重要的污染源.  相似文献   

18.
19.
Daily particle samples were collected in Santiago, Chile, at four urban locations from January 1, 1989, through December 31, 2001. Both fine PM with da < 2.5 microm (PM2.5) and coarse PM with 2.5 < da < 10 microm (PM2.5-10) were collected using dichotomous samplers. The inhalable particle fraction, PM10, was determined as the sum of fine and coarse concentrations. Wind speed, temperature and relative humidity (RH) were also measured continuously. Average concentrations of PM2.5 for the 1989-2001 period ranged from 38.5 microg/m3 to 53 microg/m3. For PM2.5-10 levels ranged from 35.8-48.2 microg/m3 and for PM10 results were 74.4-101.2 microg/m3 across the four sites. Both annual and daily PM2.5 and PM10 concentration levels exceeded the U.S. National Ambient Air Quality Standards and the European Union concentration limits. Mean PM2.5 levels during the cold season (April through September) were more than twice as high as those observed in the warm season (October through March); whereas coarse particle levels were similar in both seasons. PM concentration trends were investigated using regression models, controlling for site, weekday, month, wind speed, temperature, and RH. Results showed that PM2.5 concentrations decreased substantially, 52% over the 12-year period (1989-2000), whereas PM2.5-10 concentrations increased by approximately 50% in the first 5 years and then decreased by a similar percentage over the following 7 years. These decreases were evident even after controlling for significant climatic effects. These results suggest that the pollution reduction programs developed and implemented by the Comisión Nacional del Medio Ambiente (CONAMA) have been effective in reducing particle levels in the Santiago Metropolitan region. However, particle levels remain high and it is thus imperative that efforts to improve air quality continue.  相似文献   

20.
An atmospheric chemistry model has been approximated with a system of linear differential equations for the most relevant chemical species, and the results have been compared with the original model. Formulas for the sensitivity (and apportionment) analyses are given. The computation time is greatly reduced.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号