首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到9条相似文献,搜索用时 15 毫秒
1.
The present study examined the accidental spill of ethylene oxide, and a sensitivity analysis of the corresponding consequences was conducted using computational fluid dynamics (CFD). A validation of the gas dispersion CFD model against the experimental data sets included in the model evaluation protocol (MEP) was performed. The effect of the variability of the wind velocity on the extension of the hazardous areas and pool evaporation characteristics was evaluated. Additionally, the mitigation effects of the dike walls surrounding a spill were discussed. CFD simulation results have shown that the mitigation effect of dike walls is determined by their influence on both gas dispersion and pool evaporation and depends strongly on wind velocity in terms of toxic impact distances.  相似文献   

2.
The development and implementation of mathematical models through Computational Fluid Dynamics (CFD) techniques has been acknowledged as a promising tool for the prediction of hydrocarbon pool fires behaviours. In this sense, different approaches, with different assumptions and simplifications, and accounting for different phenomena, have been developed in the literature. However, the deviations in the predictions of the experimentally determined parameters, such as temperatures profiles, flame heights and radiative heat flux, by the implemented models are still high. Therefore, the implementation of these models to predict combustion phenomena and flame behaviours for various scenarios is limited. In this work, the software C3D is used to model gasoline pool fires of different diameters, and under different wind conditions, in order to improve the quality of the predictions of the flame behaviour. The modelled cases correspond to the experimental studies reported in literature. The results from the implemented model show an improved predictive quality when compared with other modelling works reported on literature for the same experimental cases. The deviations in the time averaged temperature, flame height, surface emissive power and radiative heat flux, has been calculated to be 5.0%, 0.05%, 6.32% and 3.82%, respectively.  相似文献   

3.
The effectiveness of the application of CFD to vapour cloud explosion (VCE) modelling depends on the accuracy with which geometrical details of the obstacles likely to be encountered by the vapour cloud are represented and the correctness with which turbulence is predicted. This is because the severity of a VCE strongly depends on the types of obstacles encountered by the cloud undergoing combustion; the turbulence generated by the obstacles influences flame speed and feeds the process of explosion through enhanced mixing of fuel and oxidant. In this paper a CFD-based method is proposed on the basis of the author’s finding that among the various models available for assessing turbulence, the realizable k-? model yields results closer to experimental findings than the other, more frequently used, turbulence models if used in conjunction with the eddy-dissipation model. The applicability of the method has been demonstrated in simulating the dispersion and ignition of a typical vapour cloud formed as a result of a spill from a liquid petroleum gas (LPG) tank situated in a refinery. The simulation made it possible to assess the overpressures resulting from the combustion of the flammable vapour cloud. The phenomenon of flame acceleration, which is a characteristic of combustion enhanced in the presence of obstacles, was clearly observed. Comparison of the results with an oft-used commercial software reveals that the present CFD-based method achieves a more realistic simulation of the VCE phenomena.  相似文献   

4.
Liquefied petroleum gas (LPG) is flammable and has risks of pool fires during its transportation, storage, and applications. The heat radiation by LPG pool fires poses hazards to individuals nearby and can lead to potential failures of ambient facilities. Due to the high costs and invasive nature of experiments for investigating large-scale pool fires, computational fluid dynamics (CFD) is employed in this study as the cost-effective and noninvasive method to simulate the process and analyze the characteristics of large hydrocarbon pool fires. Specifically, an experimentally validated 3-D CFD model has been built to simulate surface emissive power (SEP) and incident radiation of large-scale LPG pool fires with three different diameters and wind speeds. Steady-state simulations with P1 radiation and probability density function (PDF) combustion models were employed to obtain reliable data after the optimizations based on the comparisons with experimental data and empirical models. The comparison with benchmark experimental data demonstrates that the CFD model employed in this study can accurately predict the incident radiation of large LPG pool fires. A new SEP correlation is also proposed, which is specifically for LPG pool fires with a diameter between 10 m and 20 m. Additionally, the safe separation distances between LPG facilities and surrounded objects have been estimated based on the CFD simulation results. The high-resolution CFD model for large LPG pool fires in this work provides noninvasive and direct quantitative evidence to enhance the fundamental understanding on the safety of large LPG pool fires and can assist regulatory agencies in refining the safety limits in the cost-effective and time-saving manners.  相似文献   

5.
Pool fires are the most common of all process industry accidents. Pool fires often trigger explosions which may result in more fires, causing huge losses of life and property. Since both the risk and the frequency of occurrence of pool fires are high, it is necessary to model the risks associated with pool fires so as to correctly predict the behavior of such fires.Among the parameters which determine the overall structure of a pool fire, the most important is turbulence. It determines the extent of interaction of various parameters, including combustion, wind velocity, and entrainment of the ambient air. Of the various approaches capable of modeling the turbulence associated with pool fires, computational fluid dynamics (CFD) has emerged as the most preferred due to its ability to enable closer approximation of the underlying physical phenomena.A review of the state of the art reveals that although various turbulence models exist for the simulation of pool fire no single study has compared the performance of various turbulence models in modeling pool fires. To cover this knowledge-gap an attempt has been made to employ CFD in the assessment of pool fires and find the turbulence model which is able to simulate pool fires most faithfully. The performance of the standard k? model, renormalization group (RNG) k? model, realizable k? model and standard kω model were studied for simulating the experiments conducted earlier by Chatris et al. (2001) and Casal (2013). The results reveal that the standard k? model enabled the closest CFD simulation of the experimental results.  相似文献   

6.
In this study, the dust distribution in a silo during axial filling was modelled using a commercial computational fluid dynamics (CFD) code. The work focused on the dust concentration distribution in the silo, for evaluating the likelihood of a dust explosion in the silo. The simulation was conducted using a combination of renormalized (RNG) k-epsilon and discrete phase models, with standard pressure interpolation and a second order upwind scheme. The predicted dust concentration distribution showed a good agreement with experimental data adopted from the literature. It was found that the dust concentration distribution was influenced by mean velocity and turbulence flow. The simulation results suggest that the cornstarch concentration inside the silo was always above the lower explosion limit (LEL), hence requiring a mitigating action or a control system to reduce the explosion risk.  相似文献   

7.
Accidental releases of toxic gas in the chemical plants have caused significant harm to the exposed occupants. To evaluate the consequences of these accidents, a dynamic approach considering the gas dispersion and behavior evacuation modelling has been proposed in this paper. This approach is applied to a hypothetical scenario including an accidental chlorine release in a chemical plant. CFD technique is utilized to calculate the time-varying concentration filed and evacuation modelling is used to obtain the evacuation routes. The exposure concentrations in the evacuation routes are calculated by using the code of data query. The integrated concentration toxic load model and probit model are used to calculate the probability of mortality of each occupant by using the exposure concentrations. Based on this dynamic approach, a new concept of average probability of mortality (APM) has been proposed to quantify the consequences of different accidental scenarios. The results show that APM decreases when the required detection time decreases or emergency evacuation mode is implemented. The impact of the detection time on APM becomes small as the wind speed increases. The effect of emergency evacuation mode is more obvious when the release occurs in an outdoor space.  相似文献   

8.
Storage tank separation distance, which considerably affects forestalling and mitigating accident consequences, is principally determined by thermal radiation modeling and meeting industry safety requirements. However, little is known about the influence of separation distance on gas dispersion or gas explosion, which are the most destructive types of accidents in industrial settings. This study evaluated the effect of separation distance on gas dispersion and vapor cloud explosion in a storage tank farm. Experiments were conducted using Flame Acceleration Simulator, an advanced computational fluid dynamics software program. Codes governing the design of separation distances in China and the United States were compared. A series of geometrical models of storage tanks with various separation distances were established. Overall, increasing separation distance led to a substantial reduction in vapor cloud volume and size in most cases. Notably, a 1.0 storage diameter separation distance appeared to be optimal. In terms of vapor cloud explosion, a greater separation distance had a marked effect on mitigating overpressure in gas explosions. Therefore, separation distance merited consideration in the design of storage tanks to prevent gas dispersion and explosion.  相似文献   

9.
A three-dimensional CFD model was developed to simulate the turbulent flow field induced by dust feeding and the associated dust dispersion within the 20-L explosion vessel equipped with the perforated annular nozzle. The model was validated against experimental data for pressure and root mean square velocity.Simulation results have shown that the turbulent kinetic energy is rather uniformly distributed and its values are significantly lower than those attained with the rebound nozzle. Furthermore, the perforated annular nozzle is able to generate a uniform dust/air cloud. However, a consistent fraction of the dust remains trapped inside the nozzle and, thus, it does not contribute to the explosion process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号