首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 727 毫秒
1.
Results of UV photometry of water/gasoline systems are reported. It was found that this system can be characterized with an analytical light absorption peak with maximum at 260 nm. A calibrating diagram for optical density vs. gasoline content has been built for this peak and concentration limits of the gasoline compounds’ solubility in water were found. The peak pattern and its position indicate that 1,3,5-trimethylbenzene and/or its closest homologs can be those gasoline compounds, which reveal themselves through the UV light absorption peak.  相似文献   

2.
A new methodology for the assessment of thiocyanate (SCN(-)) is proposed based on optical fiber (OF) detection coupled to a liquid chromatography system (LC). The developed methodology showed an adequate performance for the analysis of SCN(-) comparable to a high performance liquid chromatography with UV detector (HPLC-UV) methodology: a detection limit of 3 μg L(-1), a linear range from 4 to 400 μg L(-1), and an analytical time of less than 6 min. The OF based methodology was of compact design and easy operation. This simple system has the potential to be used as a sensing approach for SCN(-) in seawater.  相似文献   

3.
The study on the performance of a fluorinated polyaniline (PANI) as a fiber coating for solid-phase microextraction (SPME) had been reported and 16 polycyclic aromatic hydrocarbons (PAHs) were selected to evaluate the performance of this fiber. Various parameters including sample volume, extraction temperature, time of desorption and extraction, pH and ionic strength were investigated intensively. A direct comparison between PANI-SPME fiber and commercial fiber was conducted. The results showed that the PANI-SPME coating had high affinity towards target compounds and the proposed method was successfully applied for the detection of real samples: rainfall and Taihu Lake water collected from Southern China. The whole PANI-SPME-GC method offers acceptable accuracy, precision and sensitivity and low detection limits, which is applicable to monitor trace levels of PAHs in real water bodies.  相似文献   

4.
A simple and sensitive method to determine parts per billion (ppb) of atmospheric formaldehyde in situ, using chromotropic acid, is described. A colorimetric sensor, coupled to a droplet of 15.5 microL chromotropic acid, was constructed and used to sample and quantify formaldehyde. The sensor was set up with two optical fibers, a light emitting diode (LED) and two photodiodes. The reference and transmitted light were measured by a photodetection arrangement that converts the signals into units of absorbance. Air was sampled around the chromotropic acid droplet. A purple product was formed and measured after the sampling terminated (typically 7 min). The response is proportional to the sampling period, analyte concentration and sample flow rate. The detection limit is approximately 2 ppb and can be improved by using longer sampling times and/or a sampling flow rate higher than that used in this work, 200 mL min-1. The present technique affords a simple, inexpensive near real-time measurement with very little reagent consumption. The method is selective and highly sensitive. This sensor could be used either for outdoor or indoor atmospheres.  相似文献   

5.
郝影  张朋  高峰  白煜 《中国环境监测》2022,38(3):199-206
在调研国外光污染管理政策的基础上,分析了中国光污染管理政策现状,参照现行监测技术规范,开展LED广告屏光污染测量和标准限值比较。测量结果表明:中国城市LED广告屏屏幕亮度超标严重,除了亮度外,亮度变化幅度是影响周围光环境舒适度的重要因素,白色等明亮颜色是导致居民区照度升高的重要色调。标准限值比较发现,为更好地保护光环境,应严格限制LED广告屏亮度排放值,推荐采用亮度最大值作为评价指标。  相似文献   

6.
A procedure for the determination of atmospheric acrylic acid in air at the microgram m-3 to mg m-3 level is described. Diffusion-based sampling, designed to discriminate gaseous analytes from their particulate counterparts, has been used. Acrylic acid is collected with an efficiency of > 98% in tubular denuders coated with sodium hydroxide-barium hydroxide-hydroquinone monomethyl ether, and analyzed by high performance liquid chromatography with UV absorbance detection. The detection limit is 2.9 micrograms m-3 at a flow rate of 0.5 L min-1 and 30 min sampling time. A precision (p = 0.95, n = 10) of 7.5% of the overall procedure was achieved at the 100 micrograms m-3 level. Results of laboratory studies concerning the effect of the coating reagent and the relative humidity on the sampling efficiency as well as possible interferences, in particular by ozone, and the elimination of these interferences are discussed. This method was developed to monitor workplace atmospheres as well as ambient air in industrial environments.  相似文献   

7.
Activated carbon treatment of drinking water is used to remove natural organic matter (NOM) precursors that lead to the formation of disinfection byproducts. The innate hydrophobic nature and macromolecular size of NOM render it amenable to sorption by activated carbon. Batch equilibrium and minicolumn breakthrough adsorption studies were performed using granular activated carbon to treat NOM-contaminated water. Ultraviolet (UV) absorption spectroscopy and flow field-flow fractionation analysis using tandem diode-array and fluorescence detectors were used to monitor the activated carbon sorption of NOM. Using these techniques, it was possible to study activated carbon adsorption properties of UV absorbing, fluorescing and nonfluorescing, polyelectrolytic macromolecules fractionated from the total macromolecular and nonmacromolecular composition of NOM. Adsorption isotherms were constructed at pH 6 and pH 9. Data were described by the traditional and modified Freundlich models. Activated carbon capacity and adsorbability were compared among fractionated molecular subsets of fulvic and humic acids. Preferential adsorption (or adsorptive fractionation) of polyelectrolytic, fluorescing fulvic and humic macromolecules on activated carbon was observed. The significance of observing preferential adsorption on activated carbon of fluorescing macromolecular components relative to nonfluorescing components is that this phenomenon changes the composition of dissolved organic matter remaining in equilibrium in the aqueous phase relative to the composition that existed in the aqueous phase prior to adsorption. Likewise, it changes the composition of dissolved organic matter remaining in equilibrium in the aqueous phase relative to the adsorbed phase. This research increases our understanding of NOM interactions with activated carbon which may lead to improved methods of potable water production.  相似文献   

8.
Compared with sporadic conventional water sampling, continuous water-quality monitoring with optical sensors has improved our understanding of freshwater dynamics. The basic principle in photometric measurements is the incident light at a given wavelength that is either reflected, scattered, or transmitted in the body of water. Here, we discuss the transmittance measurements. The amount of transmittance is inversely proportional to the concentration of the substance measured. However, the transmittance is subject to interference, because it can be affected by factors other than the substance targeted in the water. In this study, interference with the UV/Vis sensor nitrate plus nitrite measurements caused by organic carbon was evaluated. Total or dissolved organic carbon as well as nitrate plus nitrite concentrations were measured in various boreal waters with two UV/Vis sensors (5-mm and 35-mm pathlengths), using conventional laboratory analysis results as references. Organic carbon increased the sensor nitrate plus nitrite results, not only in waters with high organic carbon concentrations, but also at the lower concentrations (< 10 mg C L?1) typical of boreal stream, river, and lake waters. Our results demonstrated that local calibration with multiple linear regression, including both nitrate plus nitrite and dissolved organic carbon, can correct the error caused by organic carbon. However, high-frequency optical sensors continue to be excellent tools for environmental monitoring when they are properly calibrated for the local water matrix.  相似文献   

9.
Bromate (BrO(3)(-)) is a disinfection by-product formed during ozonation of potable water supplies containing bromide (Br(-)). Bromate has been classed by the World Health Organisation as a 'possible human carcinogen', leading to implementation of 10-25 microg L(-1)(as BrO(3)(-)) drinking water limits in legislative areas including the United States and European Union. Techniques have been developed for bromate analysis at and below regulatory limits, with Ion Chromatography (IC) coupled with conductivity detection (IC-CD), post-column reaction and ultra-violet (UV) detection (IC-PCR), or inductively coupled plasma-mass spectrometry detection (IC-ICPMS) in widespread use. The recent discovery of bromate groundwater contamination in a UK aquifer has led to a requirement for analysis of bromate in a groundwater matrix, for environmental monitoring and development of remediation strategies. The possibility of bromate-contaminated water discharge into sewage treatment processes, whether accidental or as a pump-and-treat strategy, also required bromate analysis of wastewater sources. This paper summarises techniques currently available for trace bromate analysis in potable water systems and details studies to identify a methodology for routine analysis of groundwater and wastewater samples. Strategies compared were high performance liquid chromatography (HPLC) with direct UV or PCR/UV detection, IC-CD, IC-PCR, and a simple spectrophotometric technique. IC-CD was the most cost-effective solution for simultaneous analysis of bromate and bromide within groundwater samples, having a 5 microg L(-1) detection limit of both anions with limited interference from closely-eluting species. Wastewater samples were successfully analysed for bromate only using HPLC with PCR/UV detection, with detection limits below 20 microg L(-1)(as BrO(3)(-)) and low interference. HPLC with direct UV detection was unsuitable for bromate analysis within the concentration range 50-5000 microg L(-1) which was required for this project, but column choice was shown to be a major factor in determining limits of detection. Spectrophotometry could not reproducibly determine bromate concentration, although the technique showed promise as a quick field method for high-level groundwater bromate analysis.  相似文献   

10.
Liquid chromatography with hydride generation atomic absorption spectrometry as the detection system was applied to the separation and determination of inorganic tin, tributyltin, dibutyltin, monobutyltin, diphenyltin and monophenyltin. A reversed phase C18 column and a methanol/water/acetic acid (70:27:3, v/v/v) mixture containing 0.05%(v/v) triethylamine and 0.1%(w/v) tropolone as the mobile phase (isocratic elution) were used. Extraction of organotins from the samples was carried out using methanol containing 0.05%(w/v) tropolone, a process that was repeated twice. The supernatants were shaken with water and dichloromethane in a separating funnel and the organic phase was collected and evaporated to dryness. When the method was applied to the speciation of tin in fresh and canned mussels, no organotins above the detection limits were identified in any of the samples, inorganic tin being the only species detected. The reliability of the procedure was checked by analyzing the total tin content of the samples by electrothermal atomic absorption spectrometry and by speciation of tin in a certified reference material, mussel tissue (CRM 477). The method can be used for environmental monitoring of organotins contaminated samples.  相似文献   

11.
建立了液相色谱法直接测定水中的10种硝基苯类化合物的方法,C18色谱柱为分离柱,检测波长为254 nm,以甲醇和水为流动相,前处理过程水和甲醇以9∶1的体积比混合,水样过微孔滤膜后直接进液相色谱分析。该法分析10种硝基苯类化合物的检出限为4.3~5.5μg/L,加标回收率为79%~136%,精密度为6.8%~13%,符合监测要求。  相似文献   

12.
A new method for separation and preconcentration of trace amounts of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) ions in various matrices was proposed. The method is based on the adsorption and chelation of the metal ions on a column containing Amberlite XAD-1180 resin impregnated with 1-(2-thiazolylazo)-2-naphthol (TAN) reagent prior to their determination by flame atomic absorption spectrometry (FAAS). The effect of pH, type, concentration and volume of eluent, sample volume, flow rates of sample and elution solutions, and interfering ions have been investigated. The optimum pH for simultaneous retention of all the metal ions was 9. Eluent for quantitative elution was 20 ml of 2 mol l(-1) HNO(3). The optimum sample and eluent flow rates were found as 4 ml min(-1), and also sample volume was 500 ml, except for Mn (87% recovery). The sorption capacity of the resin was found to be 0.77, 0.41, 0.57, and 0.30 mg g(-1) for Cu(II), Ni(II), Cd(II), and Mn(II), respectively. The preconcentration factor of the method was 200 for Cu(II), 150 for Pb(II), 100 for Cd(II) and Ni(II), and 50 for Mn(II). The recovery values for all of the metal ions were > or = 95% and relative standard deviations (RSDs) were < or = 5.1%. The detection limit values were in the range of 0.03 and 1.19 microg l(-1). The accuracy of the method was confirmed by analysing the certified reference materials (TMDA 54.4 fortified lake water and GBW 07605 tea samples) and the recovery studies. This procedure was applied to the determination of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) in waste water and lake water samples.  相似文献   

13.
A simple and sensitive method was developed for determination of trace copper by direct precipitation preconcentration and detection with Flame Atomic Absorption Spectrometry (FAAS). The reagent 2-[2'-(6-methyl-benzothiazolylazo)]-4-aminophenol (Me-BTAP) was used as precipitating agent. The experimental conditions for the quantitative precipitation of copper, such as pH, amount of reagents, temperature and the effect of diverse ions on the precipitation have been investigated. It was found that copper is quantitatively extracted (> or =95%) and the method provides a sensitivity enhancement of 40-fold for a 10 ml sample volume with a detection limit of 0.5 microg l(-1). The proposed method was successfully applied for the determination of trace copper in water, urine and biological samples.  相似文献   

14.
A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)–diethyldithiocarbamate–(Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1–2.2 μg L?1 while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions.  相似文献   

15.
A simple, sensitive, and accurate UV spectrophotometric method has been developed for the determination of nickel in synthetic mixture and water samples. The method is based on the complexation reaction of nickel ion with cefixime, thus leading to the formation of Ni–cefixime complex in ethanol-distilled water medium at room temperature. The complex showed the maximum absorption wavelength at 332 nm. Beer’s law is obeyed in the working concentration range of 0.447–4.019 μg?mL?1 with apparent molar absorptivity of 7.314?×?103?L?mol?1?cm?1 and Sandell’s sensitivity of 0.008 μg/cm2/0.001 absorbance unit. The limits of detection and quantitation for the proposed method are 0.016 and 0.054 μg?mL?1, respectively. The factors such as cefixime concentration and solvent affecting the complexation reaction were carefully studied and optimized. The method is validated as per the International Conference on Harmonisation guideline. The method is successfully applied to the determination of Ni(II) in synthetic mixture and wadi water samples collected from Al Rustaq. The same water samples are also analyzed by atomic absorption spectrophotometry. Both methods determined the amount of Ni(II) in water sample and found to be approximately the same.  相似文献   

16.
The distribution of aqueous Tl(I)/Tl(III) as a function of light exposure and solution properties was studied by quantifying the oxidation states after separation with ion chromatography and on-line detection with ICP-MS. Ultraviolet irradiation of aqueous solutions containing 1 microg l(-1) Tl(III) and in equilibrium with the atmosphere increases the reduction rate. In systems with photoreduction of Fe(III)(aq) a quantitative oxidation of Tl(I)(aq) was observed, notably at low pH. The process is reversible, as indicated by formation of Tl(I) when the irradiated systems were kept in the dark. In systems with colloidal silica-stabilised ferrihydrite, UV irradiation also leads to oxidation of Tl(I)(aq), but not quantitatively. It is suggested that adsorption of thallium to the ferrihydrite determines the rate of oxidation. Detectable, but not quantitative, oxidation of Tl(I)(aq) took place when natural water samples with 1 microg l(-1) Tl(I)(aq) were exposed to either sunlight or UV-light. For these samples, the reduction was not quantitative when they were kept in the dark for 24 h. The results suggest that the light dependent iron cycle in fresh water systems strongly influences the redox state of thallium.  相似文献   

17.
A new method utilizing the diffusive sampling of formaldehyde in air has been developed. Formaldehyde is sampled with the use of a glass fiber filter impregnated with N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH) and phosphoric acid. The formaldehyde hydrazone formed is desorbed from the filter with acetonitrile and determined by high-performance liquid chromatography (HPLC) with UV/visible detection at 474 nm. The sampling rate was determined to be 24.7 mL min-1 with a relative standard deviation of 7% for 48 experiments. The measured sampling rates were not dependent on the formaldehyde concentration (0.1-1.0 mg m-3), sampling time (15-482 min) or relative humidity (20-85%). The detection limit was 70 micrograms m-3 for a 15 min sampling period and 2 micrograms m-3 for an 8 h sampling period.  相似文献   

18.
石墨炉原子吸收分光光度法测定地表水中的锑   总被引:1,自引:0,他引:1  
采用石墨炉原子吸收分光光度法测定地表水中的锑,优化了仪器测量参数,讨论了干扰离子的干扰。方法在0μg/L~100μg/L范围内线性良好,检出限为0.9μg/L,平行测定的RSD为1.3%~9.8%,加标回收率为97.9%~104%,标准样品的测定结果符合要求。  相似文献   

19.
A simple, rapid, and efficient dispersive liquid–liquid microextraction method, followed by UV–Vis spectrophotometry was developed for the preconcentration and determination of Pd ions in water samples. Pd ions react with α-furildioxime (chelating agent) to form a hydrophobic complex. Various parameters were altered to study and optimize their effects on the extraction efficiency, such as pH, ligand concentration, the type and volume of extraction and dispersive solvents, extraction time, and salt concentration. Under optimized conditions, the method exhibited an enrichment factor (C org/C aq) of 25 and recovery more than 98 % within a very short extraction time. The linearity of the method ranged from 10 to 200 μg?L?1. The limit of detection was 1.1 μg?L?1. The relative standard deviation for the concentration of 100 μg?L?1 of Pd was 2.3 % (n?=?10). Finally, the developed method was successfully applied to the extraction and determination of Pd in tap, river, mineral, and sea water samples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号