首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Measurements of the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were made in ambient air, ash, and soil impacted by the open burning of wax apple and rice straw residues. Measurements showed that the mean PCDD/F concentration (0.458 pg I-TEQ/Nm3; international toxicity equivalence) in air at two wax apple orchards during open burning increased markedly, -8.1 times higher than that (0.057 pg I-TEQ/Nm3); before open burning. In addition, the mean PCDD/F concentration (0.409 pg I-TEQ/Nm3) in ambient air at a rice straw field was 4.6 times higher than that (0.089 pg I-TEQ/Nm3) before open burning. After burning the residues of wax apple stubble and rice straw, the contents of PCDD/F in ashes were 1.393 and 1.568 ng I-TEQ/kg-ash, respectively, and the contents of PCDD/F in soil were 2.258 and 2.890 ng I-TEQ/kg-soil, respectively. Therefore, the turnover of soil with the ash after open burning over years will result in the accumulation of PCDD/Fs in farm soils.  相似文献   

2.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

3.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

4.
Abstract

To understand the fate of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in a fly ash treatment plant that used the Waelz rotary kiln process (hereafter the Waelz process), the samples of input and output media were collected and analyzed. The most important PCDD/F source in input mass was electric arc furnace (EAF) fly ash, which had a mean PCDD/F content of 18.51 ng/g and contributed more than 99% of PCDD/F input mass, whereas the PCDD/F input mass fractions contributed by the coke, sand, and ambient air were only 0.04%, 0.02%, and 0.000002%, respectively. For the PCDD/F output mass in the Waelz process, the major total PCDD/F contents of 43.73 and 10.78 ng/g were in bag-filter and cyclone ashes, which accounted for approximately 69% and 17%, respectively, whereas those of stack flue gas and slag were 14% and 0.423%, respectively. The Waelz process has a dechlorination mechanism for higher chlorinated congeners, but it is difficult to decompose the aromatic rings of PCDD/Fs. Therefore, this resulted in the accumulation of lower chlorinated congeners. The output/input ratio of total PCDD/F mass and total PCDD/F international toxicity equivalence (I-TEQ) was 0.62 and 1.19, respectively. Thus, the Waelz process for the depletion effect of total PCDD/F mass was positive but minor, whereas the effect for total PCDD/F I-TEQ was adverse overall.  相似文献   

5.
To understand the fate of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in a fly ash treatment plant that used the Waelz rotary kiln process (hereafter the Waelz process), the samples of input and output media were collected and analyzed. The most important PCDD/F source in input mass was electric arc furnace (EAF) fly ash, which had a mean PCDD/F content of 18.51 ng/g and contributed more than 99% of PCDD/F input mass, whereas the PCDD/F input mass fractions contributed by the coke, sand, and ambient air were only 0.04%, 0.02%, and 0.000002%, respectively. For the PCDD/F output mass in the Waelz process, the major total PCDD/F contents of 43.73 and 10.78 ng/g were in bag-filter and cyclone ashes, which accounted for approximately 69% and 17%, respectively, whereas those of stack flue gas and slag were 14% and 0.423%, respectively. The Waelz process has a dechlorination mechanism for higher chlorinated congeners, but it is difficult to decompose the aromatic rings of PCDD/Fs. Therefore, this resulted in the accumulation of lower chlorinated congeners. The output/input ratio of total PCDD/F mass and total PCDD/F international toxicity equivalence (I-TEQ) was 0.62 and 1.19, respectively. Thus, the Waelz process for the depletion effect of total PCDD/F mass was positive but minor, whereas the effect for total PCDD/F I-TEQ was adverse overall.  相似文献   

6.
Levels of dioxins and furans in urban surface soil in Trondheim, Norway   总被引:1,自引:0,他引:1  
A study was conducted on polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in surface soil in order to determine the concentration levels and possibly distinguishing between known and potential sources. The concentration levels are low (0.16-14 ng I-TEQ kg(-1)). The results show a clear pattern where the highest concentration levels were found in the oldest parts of the city. A number of sources were recognised in the soil samples through congener profiles, not all of them active, although similar congener profiles make it extremely difficult to distinguish between different sources. Estimations show that the municipal solid waste incinerator (MSWI) and domestic wood burning are the largest PCDD/F pollution sources within the area.  相似文献   

7.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

8.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

9.
Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) and polychlorinated biphenyls (PCB) were determined in 23 soil samples collected at reference sites of the Swiss national soil monitoring network (NABO). Total PCDD/F and PCB concentrations are well correlated and proportional (R2=0.720). The total PCDD/F levels were between 72 and 703 ng/kg corresponding to 1.1-11 ng I-TEQ/kg, total PCB concentrations (sum of seven congeners IUPAC no. 28, 52, 101, 118, 138, 153, and 180) were from 1.1 to 12 microg/kg. In all samples, the PCDD/F and PCB concentrations were in the range of background levels for these contaminants in Central Europe. Ninteen samples revealed PCDD/F levels below the guide value of 5 ng I-TEQ/kg set by the Swiss ordinance relating to impacts on the soil (OIS); concentrations for the remaining four samples were below the trigger value (20 ng I-TEQ/kg). All PCB concentrations were below the guide value of 100 microg/kg. The elevated PCDD/F and PCB levels in some of the samples originating from forested sites could be attributed to the scavenging effect of forest canopies for semivolatile organic compounds. This interpretation could be substantiated by the observed distortion of the congener and homolog patterns of PCDD/F and PCB which is characteristic for forested sites.  相似文献   

10.
Xu MX  Yan JH  Lu SY  Li XD  Chen T  Ni MJ  Dai HF  Cen KF 《Chemosphere》2008,71(6):1144-1155
Isomer-specific data were investigated in order to identify the sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in agricultural soils, including Fluvo-aquic and paddy soils, in the vicinity of a Chinese municipal solid waste incineration (MSWI) plant. Homologue and isomer profiles of PCDD/Fs in soils were compared with those of potential sources, including combustion sources, i.e., MSWI flue gas and fly ash; and the impurities in agrochemicals, such as the pentachlorophenol (PCP), sodium pentachlorophenate (PCP-Na) and 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP). The results showed that the PCDD/F isomer profiles of combustion sources and agricultural soils were very similar, especially for PCDFs, although their homologue profiles varied, indicating that all the isomers within each homologue behave identically in the air and soil. Moreover, factor analysis of the isomer compositions among 33 soil samples revealed that the contamination of PCDD/Fs in agricultural soils near the MSWI plant were primarily influenced by the combustion sources, followed by the PCP/PCP-Na and CNP sources. This implication is consistent with our previous findings based on chemometric analysis of homologue profiles of soil and flue gas samples, and identifies PCP/PCP-Na as an additional important source of PCDD/Fs in the local area. This makes the similarities and differences of isomer profiles between Fluvo-aquic and paddy soils more explainable. It is, therefore, advisable to use isomer-specific data for PCDD/F source identifications where possible.  相似文献   

11.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

12.
Dechlorination of commercial mixtures of polychlorinated biphenyls (PCB) as well as polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) on extracted and non-extracted fly ash obtained from municipal waste incinerator (MWI) was studied in closed systems under nitrogen atmosphere at temperatures of 260°C and 340°C. Decomposition results (given as the difference between PCB or PCDD/F molar amounts before and after the experiment (in %) due predominantly to dechlorination reactions) and detoxification data (expressed similarly but related to toxic PCB and PCDD/F congeners only and given in I-TEQ units) are reported. Detoxification of Delor 105/80T at 260°C and 340°C at a loading of 0.65 wt% was 99.48% and 100%, respectively. The decomposition of Delor 103 at 340°C and for the loading of 0.75 wt% corresponded to 99.99%. The detoxification capability of PCDD/Fs on extracted and non-extracted fly ash for loading of 130 and 264 ng/0.4 g of fly ash at 340°C made 96 and 98%, respectively.  相似文献   

13.
In this study, bottom ash was sampled from two Taiwanese municipal solid waste incinerators (MSWIs: A and B) and sieved to size classes of 4.75-9.5 mm, 2.36-4.75 mm, 1.0-2.36 mm, 0.6-1.0 mm, 0.3-0.6 mm, 0.21-0.3 mm, 0.125-0.21 mm, 0.075-0.125 mm and <0.074 mm. For both MSWIs, the major peak in the particle size distribution for the PCDD/F content was found in a particle size <0.21 mm, that is, 16.1 (A) and 4.37 pg I-TEQ/g (B). This is due to the fact that a smaller particle has higher specific surface area thus offering more adsorption sites. The mean cumulative fractions (F%) of PCDD/F I-TEQ in the bottom ash of MSWI A and B in the particle size range below 0.6, 2.36 and 4.75 mm, in sequence, are 40.4%, 77.2% and 95.6%, respectively. We suggest sieving the bottom ash before the subsequent reutilization at the suggested cut size of 0.6 mm. In the view of PCDD/Fs, bottom ash with a particle size larger than 0.6 mm, which is the more non-hazardous part, may be suitable for being the raw material of landfilling soil, road sub-base, and construction blocks. For the minus 0.6 mm fraction, vitrification with fly ash is one of the choices.  相似文献   

14.
The construction in Constantí (Catalonia, Spain) of a new hazardous waste incinerator (HWI), which is the first one in Spain, finished in 1999. In order to determine the temporal variation (1996–1998) in the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in the vicinity of the new HWI, 40 soil and 40 herbage samples were collected (1998) at the same sampling points in which samples had been taken two years before (1996). Each sample was analyzed for PCDDs and PCDFs by high resolution gas chromatography/high resolution mass spectrometry. In the 1996 survey, PCDD/F concentrations in soils ranged from 0.13 to 24.20 ng I-TEQ/kg (d.m.), with median and mean values of 0.67 and 1.68 ng I-TEQ/kg (d.m.), respectively. In the present study, PCDD/F concentrations ranged from 0.12 to 17.20 ng I-TEQ/kg (d.m.), with a median value of 0.75 ng I-TEQ/kg (d.m.) and a mean value of 1.59 ng I-TEQ/kg (d.m.). In turn, in the present study PCDD/F concentrations in vegetation ranged from 0.14 to 2.01 ng I-TEQ/kg (d.m.) (median and mean values: 0.23 and 0.31 ng I-TEQ/kg, respectively), while in the 1996 survey PCDD/F concentrations ranged from 0.24 to 1.22 ng I-TEQ/kg (d.m.) (median and mean values: 0.53 and 0.61 ng I-TEQ/kg, respectively). According to the present (1998) and the previous (1996) levels of PCDD/Fs found in soils and vegetation, the area under potential influence of the new facility shows a rather low contamination by these compounds. The current results should be useful to establish the environmental impact of the HWI.  相似文献   

15.
Temporal and local trends of PCDD/F levels in cow's milk in Switzerland   总被引:5,自引:0,他引:5  
Schmid P  Gujer E  Zennegg M  Studer C 《Chemosphere》2003,53(2):129-136
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) were determined in 30 Swiss cow's milk samples collected at dairy farms in the vicinity to point sources, in rural/alpine areas distant to known sources, and from tanks in large industrial milk processing plants. The contaminant concentrations in samples collected in 2001 were compared to data from analyses conducted in 1984 and 1990/1991 at the same sites. In 2001, the PCDD/F levels in milk from farms near point sources (0.63+/-0.26 ng I-TEQ/kg milk fat) are slightly but significantly higher in than milk from remote areas (0.36+/-0.09 ng I-TEQ/kg milk fat). Consumer milk collected at the processing plants had intermediary levels (0.51+/-0.19 ng I-TEQ/kg milk fat). However, milk in 2001 was significantly less contaminated than the samples collected in 1990/1991 and 1984. This trend is particularly pronounced near point sources but is also apparent in consumer milk and milk from remote areas. No geographical gradient in the atmospheric input of PCDD/F in Switzerland was found. The reduction in PCDD/F levels in dairy milk is paralleled by and correlated to the remediation of known PCDD/F emitting industries, as enforced by federal authorities.  相似文献   

16.
Polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF) levels were determined in adipose tissue of 15 autopsied subjects who at the time of death had lived in the city of Tarragona (Catalonia, Spain) and surroundings during at least the last 10 years. PCDD/F concentrations ranged between 13.37 and 69.37 ng I-TEQ/kg fat, with mean and median values of 30.98 and 26.30 ng I-TEQ/kg fat, respectively. PCDD/F concentrations were higher (p < 0.01) in women (mean value: 44.95 ng I-TEQ/kg fat) than in men (mean value: 24.00 ng I-TEQ/kg fat). Although individuals living in industrial areas showed higher PCDD/F levels than those living Tarragona downtown the difference was not statistically significant. When Principal Component Analysis was applied to the concentrations of PCDD/Fs found in the 15 adipose tissue samples together with those found in 20 blood samples collected in a previous study, a single two-dimensional model was obtained, which would explain 62.9% of the variance in the data. The PCDD/F concentrations in adipose tissue found in the current study are of the same order of magnitude than those reported for most industrialized countries.  相似文献   

17.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

18.
PCDD/F analyses were made in soil and ambient air samples taken from Kocaeli, an industrialized area of Turkey. Results showed that the levels of PCDD/F pollution are comparable to the levels observed in the various urban areas in the world. PCDD/F concentrations in surface soils ranged between 0.4 and 4.27 pg I-TEQ kg(-1) with a geometric mean of 0.76 pg I-TEQ kg(-1), while those in ambient air were between 23 and 563 f gm(-3), with geometric mean of 82.0 f gm(-3). Ambient air PCDD/F concentration in the city center was about 10 times higher than those in the rural area. Combustion activities present in the area were assessed to be the most significant source of the PCDD/F pollution based on the congener and homologue profiles and statistical analysis of the data. The deposition rate modeling of USEPA was applied and the deposition rates were determined in the range between 7.6 and 66.3 ng I-TEQ m(-2)year(-1) with a geometric mean of 15.9 ng I-TEQ m(-2)year(-1). The rates were higher than the recommended deposition rates in relation to the tolerable daily intake (TDI) range of PCDD/Fs for humans. The deposition velocities computed were also found to be high in both low and highly chlorinated PCDD/Fs, and this was attributed to the vapor phase deposition of volatile PCDD/Fs, and the scavenging effect of the precipitation on the particle-bound PCDD/Fs.  相似文献   

19.
Priority organic pollutant assessment of sludges for agricultural purposes   总被引:2,自引:0,他引:2  
A comprehensive characterization of five of the seven priority organic pollutants listed in the draft of the "Working document on sludge" [EU, 2000. Working Document on Sludge 3rd Draft. Unpublished, 19 p] has been carried out during 2001-2003 in sludge samples from Catalonia (NE Spain). One hundred and thirty-nine samples belonging to 20 Waste Water Treatment Plants (WWTPs), seven sludge treatment (thermal drying) and three composting sludge plants were taken in order to determine the concentration of polychlorinated dibenzo-p-dioxins and -furans (PCDD/Fs), di-2-(ethyl-hexyl)-phthalate (DEHP), nonylphenol and nonylphenol ethoxylates with one or two ethoxy groups (NPE), polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). PCDD/F concentrations were in general lower than the 100 ng I-TEQ/kg limit suggested in the above-mentioned document. In the same way, 98.5% for PCBs, 97% for PAH and 92.8% for DEHP of the samples presented concentrations lower than 0.8 mg/kg dm, 6 mg/kg dm and 100 mg/kg dm, respectively. In contrast, the vast majority of samples contained NPE concentrations much higher than 50mg/kg dm limit. The values ranged from 14.3 to 3150 mg/kg dm (median value=286.6 mg/kg) being composted sludge samples the less contaminated ones (17.9-363.4 mg/kg dm; median value=89.3 mg/kg). Special attention should be paid to the Catalan sludge NPE contamination owing to the high levels detected.  相似文献   

20.
Levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in both air and soil samples were measured at three different sites in Italy, in proximity to three municipal solid waste incinerators (MSWIs) to determine baseline contamination and the contributory role of incinerator emissions. At the first site, located in an agricultural, cattle-breeding, typically flattish area of the Po Valley, the dioxin concentrations had already been measured before the start-up of the new MSWI. These dioxin concentrations were then again measured after two years of continual operation of the incinerator. Despite the presence of the plant, the PCDD/Fs concentrations appear not to have been affected and were found to be in a range of 22-125 fg I-TEQ m(-3) in the air samples and 0.7-1.5 pg I-TEQ g(-1) in the soil samples. The second site is located in an industrial district of the Veneto Region, in the surroundings of an old MSWI that is not equipped with Best Available Technology (BAT) dioxin removal system. The PCDD/Fs concentrations in the air samples were between 144 and 337 fg I-TEQ m(-3). This is a typical range of values for industrial areas, while the soil samples showed contamination levels between 1.1 and 1.4 pg I-TEQ g(-1). The third site lies in the Adige Valley, near a MSWI that has been equipped with BAT for flue gas cleaning. The observed values ranged from 10 to 67 fg I-TEQ m(-3) for the air samples and 0.08-1.2 pg I-TEQ g(-1) for the soil samples. The contributory factors of the varying characteristics of the different areas together with the types of technology adopted at each MSWI plant are discussed. The PCDD/Fs levels are subsequently compared with established values from previous studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号