首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Chen HL  Su HJ  Liao PC  Chen CH  Lee CC 《Chemosphere》2004,54(10):1421-1429
The aim of this study was to evaluate the serum polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) concentration distribution in residents living in the vicinity of an incinerator and its association with annual ambient dioxin exposure predicted by an atmospheric dispersion model. A municipal waste incinerator in Northern Taiwan was chosen for this study. This incinerator had been in operation for 6 years at the time of this study. Using the incinerator site as the center, based on the simulated ambient annual average PCDD/F concentrations. Ninety-five volunteers, all live within a radius of 5 km from the incinerator for at least 5 years, who had no occupational exposure potential, were selected based on the population distribution in each district. The average serum PCDD/F concentration for these subjects living within four zones was about 14 pg I-TEQ/g lipid. The serum distribution levels of people of the four study zones, however, were not consistent with the predicted ambient levels. Results also suggest that ambient exposure might not be the most important contributor to serum concentrations when compared to other exposure sources, such as dietary intake.  相似文献   

2.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were monitored in stack gas and fly ash of various Korean incinerators and in air samples collected near the facilities. Concentrations of PCDD/Fs in emissions were investigated, and characteristic PCDD/F homologue patterns were classified using statistical analyses. The PCDD/F emission levels in stack gas and fly ash samples from small incinerators (SIs) were higher than those from municipal solid waste incinerators (MSWIs). The PCDD/F concentrations ranged between 0.38 and 1.16 pg I-TEQ/m3 (21.2-75.2 pg/m3) in ambient air samples. The lower-chlorinated furans were the dominant components in most of the stack gas and fly ash samples from SIs, although this was not the case for fly ash from MSWIs. This homologue pattern is consistent with other studies reporting a high fraction of lower-chlorinated furans in most environmental samples affected by incinerator emissions, and it can be used as an indicator to assess the impact of such facilities on the surrounding environment.  相似文献   

3.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

4.
Kim BH  Lee SJ  Mun SJ  Chang YS 《Chemosphere》2005,58(11):1589-1599
Many studies have been conducted that monitor and trace the sources of polychlorinated dibenzo-p-dioxin/furans (PCDD/Fs) by comparing congener patterns of environmental samples with those of possible sources. In this study, we measured PCDD/F concentrations and compared congener patterns of samples of various media found in and around an industrial waste incinerator in Korea, including stack gas, fly ash, bottom ash, ambient air, soil, pine needle, and human blood. We obtained reliable data on the relationship between the PCDD/F distributions in these sources and the environment, and thus found indicators with which to assess the impact of such sources on the surrounding environment. In addition, the difference between the levels of PCDD/Fs in the blood of short-term workers and long-term workers demonstrates that these workers are exposed to the compounds produced by the indicator.  相似文献   

5.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

6.
Modeling the formation of PCDD/F in solid waste incinerators   总被引:1,自引:0,他引:1  
Stanmore BR 《Chemosphere》2002,47(6):565-573
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) appear in unacceptable amounts in the gaseous emissions during the incineration of wastes containing significant quantities of chlorine and metals, such as MSW and medical waste. They are formed both in the gas phase at temperatures above 600 degrees C and on the surface of the solid phase (flyash) in the temperature range 400-225 degrees C. Both the precursor (from existing smaller chlorinated molecules) and de novo (from elemental carbon) routes are involved. An empirically derived global model for their de novo formation on flyash in MSW and medical waste incinerators has now been extended to include the precursor mechanism, and a gas phase formation component, with separate rate expressions for PCDD and PCDF. Homogeneous PCDD formation is governed by the concentration of chlorophenols and PCDF by that of chlorophenols and chlorobenzenes. The result is more complete system which distinguishes between the gas and solid phase contributions to the I-TEQ. An additional step for the adsorption of gaseous PCDD/F back onto the solid phase during cooling suggests this should be minimal in the gas ducts of an incinerator. The extended model has been tested against experimental data collected from a well-controlled pilot incinerator and commercial incinerators, and found to adequately describe the measured outputs. With the model it should be possible to predict the PCDD/F emissions from commercial incinerators, provided that the ash properties and the overall temperature-time profiles are known.  相似文献   

7.
BACKGROUND: To observe the relationship between the PCDD/F and Co-PCB levels in samples of human breast milk and nearby waste incinerators in Tokyo, Japan. METHODS: Breast milk was taken from 240 mothers residing in Tokyo, Japan to measure and analyze the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs; 14 congeners), polychlorinated dibenzofurans (PCDFs; 15 congeners), and coplanar polychlorinated biphenyls (Co-PCBs; 12 congeners) contained in the fat. Individual milk samples (about 50 ml) were obtained from the mothers 30 days after delivery, between the months of June and September in 1999 and 2000. A map of Tokyo was used to measure the distances between each mother's place of residence and the closest public and industrial waste incinerators. RESULTS: The distances to the nearest waste incinerators bore no apparent correlations with the congeners of PCDD/Fs and Co-PCBs. The distances were also uncorrelated with the mean toxic equivalent quantities (TEQs) of PCDD/Fs (the sum of PCDDs and PCDFs), Co-PCBs, and the total PCDD/Fs and Co-PCBs. CONCLUSIONS: Although waste incinerators were the largest source of dioxins in Japan at the time of the study, the dioxins levels of mother's milk bore no apparent relationships with the distances between the mothers' domiciles and the nearest waste incinerators. In this study, several meaningful factors were not taken into account, namely, the wind direction, the level of dioxin emitted from each incinerator, the level of environmental pollution of dioxins, and the average time the mothers stayed at home each day. A full understanding of these points awaits future studies.  相似文献   

8.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

9.
H.Y. Tong  F.W. Karasek 《Chemosphere》1986,15(9-12):1219-1224
Flyash samples were collected from the electrostatic precipitators of seven municipal refuse incinerators of four different countries. Analytical results of PCDD and PCDF in these samples shows a very similar iosmer distribution pattern for all PCDD/PCDF although concentrations of PCDD and PCDF vary. These results imply that PCDD/PCDF were formed through the same mechanism in those incinerators regardless of garbage composition or incinerator design.  相似文献   

10.
The Escambia Wood Treating Company (ETC) Superfund site, Pensacola, FL, is contaminated with polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F), benzo(a)pyrene, lead and arsenic from pentachlorophenol (PCP), creosote, and other compounds used to treat utility poles and foundation pilings. Although ETC's operations ceased in 1982, soils in the areas surrounding the facility continue to exhibit elevated levels of contaminants attributable to ETC operations. In July 2000, individuals who may have been affected by contamination from the ETC site, including current and former residents and former workers and their household members were invited to participate in a study, which included a health and exposure history and routine blood analysis. We also conducted a toxicological health evaluation of a subset of these eligible workers/residents by analyzing serum levels of 17 PCDD/F congeners. Members of the ETC cohort exhibited elevated serum PCDD/F relative to the general population, and congener profiles in members of the cohort reflected patterns commonly observed in persons exposed to PCP. Hypertension prevalence in the cohort was found to correlate with PCDD/F levels, although no other significant relationships were identified with monitored health indices.  相似文献   

11.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

12.
Mechanisms that have been proposed to account for the emission of PCDD/PCDF from municipal waste incinerators were evaluated in the light of extensive experimental data obtained from the Quebec City municipal solid waste incinerator by Environment Canada. It was found that PCDD/PCDF emissions were closely related to the quantity of material entrained by the combustion gases.  相似文献   

13.
PCDD/Fs are one of the most studied molecules in the world because of their toxicity. In the last years the toxicity of these compounds has been analyzed in details. For years PCDD/F inventories have pointed out the significant role of municipal solid waste (MSW) incinerators in the overall balance. Recently, thanks to new regulations on PCDD/F emissions, in a few countries this scenario is changing: it can be demonstrated that modern MSW incinerators can play a secondary role even if the percentage of MSW sent to combustion has increased. In the latest inventories an unconventional source of PCDD/F has appeared: in nineties some biogas characterizations have demonstrated that there is a release of PCDD/F from MSW sanitary landfills. In addition, the combustion of collected biogas can generate not negligible amounts of PCDD/F. A new question can be put: does the MSW contribute with other management options to the overall balance of PCDD/F? The present work points out that a detailed inventory should take into account also the PCDD/F release from bio-mechanical treatment plants (both composting and bio-drying/bio-stabilization plants). However the contribution from this option is secondary when it is compared with the one from old MSW incinerators.  相似文献   

14.
Biomonitoring of dioxin body burden, as evaluated by PCDD/F levels in blood, has been carried out in a total of 138 adults from general population living in the vicinity of solid waste incinerators in Portugal. Measurements were performed included in cross-sectional surveys within two Environmental Health Surveillance Programs launched in response to ecotoxicological concern in relation to solid waste incinerators near Lisbon and in Madeira Island. Overall conclusion from first published results is indicative that dioxin exposure of global populations cannot be related to the emissions of these facilities, meaning that dioxin sources control seems to be effective in relation to both incinerators. Main objective of present work was to investigate potential determinants of dioxin levels in the studied populations. Findings from this investigation also suggest that incineration does not impact on dioxin blood levels of nearby residents. Follow-up of a small group of individuals (22) from Lisbon gives preliminary indication on temporal control effectiveness of the Lisbon facility. Regarding comparison between PCDD/F levels from Lisbon and Madeira communities, individuals from Lisbon show higher median PCDD/F levels, likely to be better explained by more highly polluted areas in Lisbon than by eventual differences in dietary habits of the studied groups. In fact, analysis performed on the diet of both groups (not detailed in the present study) does not show a statistically significant difference in relation to any of the most relevant foodstuffs in the context of dioxin exposure. Comparison between Lisbon and Madeira in relation to pattern of the single congeners for PCDD/Fs shows a very similar profile. The highest contributions to the PCDD/Fs toxicity came from 12378-PCDD, 23478-PCDF, Hexa-CDD, 2378-TCDD and Hexa-CDF.  相似文献   

15.
Lee CC  Chen HL  Su HJ  Guo YL  Liao PC 《Chemosphere》2005,59(10):1465-1474
The aim of this study was to evaluate the PCDD/Fs patterns in ambient air based on data information emitted from incinerator generated from ambient air measurements and those in serum. Four circular zones, namely A, B, C, and D, were identified based on simulated ambient annual average PCDD/Fs concentrations, from a selected municipal waste incinerator. Sixteen ambient samples were taken from the 4 circular zones across 4-seasons. Eighty-nine volunteers were recruited according to the demographic distribution within each zone. PCDD/Fs profiles were documented both for air and serum samples collected. Comparing to the congener patterns from ambient air and serum samples, we found that OCDD, OCDF, 1,2,3,4,6,7,8-HpCDD, and 1,2,3,4,6,7,8-HpCDF were the predominant groups among 17 congeners from both the ambient air and serum sample. And, factor analysis showed the distribution patterns of PCDD/Fs from ambient air and serum samples are almost identical across different zones, except for congener patterns of serum samples from residents in zone C. In addition, the average PCDD/Fs level significantly reduced for about 10 folds than those of the other three seasons when the incinerator was shut down in one of sampling periods. We might conclude that ambient air exposure was the most important contributor to PCDD/Fs levels in ambient air but not the single in serum. Therefore, another or more powerful source, such as occupational exposure, dietary intake or the consumption of local food, should be further investigated at the same time.  相似文献   

16.
Significant dioxin (polychlorinated dibenzo-para-dioxins (PCDDs)/polychlorinated dibenzo-furans (PCDFs)) pollution from a municipal solid waste incinerator was discovered in 1997 in Osaka prefecture/Japan. The cause and mechanism of pollution was identified by a detailed assessment of the environment and incinerator plant. The primary sources of PCDD/PCDF pollution were high dioxin releases from an intermittently operated waste incinerator with PCDD/PCDF emissions of 150 ng-TEQ/Nm3. PCDD/PCDF also accumulated in the wet scrubber system (3,000 μg TEQ/L) by adsorption and water recirculation in the incinerator. Scrubber water was air-cooled with a cooling tower located on the roof of the incinerator. High concentrations of dioxins in the cooling water were released as aerosols into the surrounding and caused heavy soil pollution in the area near the plant. These emissions were considered as the major contamination pathway from the plant. Decontamination and soil remediation in and around the incinerator plant were conducted using a variety of destruction technologies (including incineration, photochemical degradation and GeoMelt technology). Although the soil remediation process was successfully finished in December 2006 about 3 % of the waste still remains. The case demonstrates that releases from incinerators which do not use best available technology or which are not operated according to best environmental practices can contaminate their operators and surrounding land. This significant pollution had a large impact on the Japanese government’s approach toward controlling dioxin pollution. Since this incident, a ministerial conference on dioxins has successfully strengthened control measures.  相似文献   

17.
ABSTRACT

Emissions of polychlorinated dibenzo-p-dioxins and poly-chlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alk-ene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alk-enes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

18.
Dioxins and furans were detected in emissions from eight medical waste incinerators tested in California. Total uncontrolled emissions ranged from 363 to 11, 811 nanograms per dry standard cubic meter. The most effective of three wet scrubbers achieved an emissions control efficiency of 95 percent for total PCDD and PCDF. A baghouse was less than 30 percent efficient in removing PCDD and PCDF from the incinerator emissions.  相似文献   

19.
Cunliffe AM  Williams PT 《Chemosphere》2007,68(9):1723-1732
The influence of temperature on the levels of PCDD and PCDF remaining in, and desorbed from, a municipal solid waste incinerator flyash was investigated by heating the ash to between 200 and 400 degrees C under a simulated flue gas for four days reaction time. Considerable desorption of PCDD/PCDF from the flyash was seen at 275 degrees C and above. Maximum desorption occurred at 350 degrees C, with the equivalent of nearly eight times the total PCDD/PCDF concentration of the original flyash being lost to the vapour phase per unit mass of initial flyash. The I-TEQ value of the desorbed PCDD/PCDF was considerable, being over fourteen times that of the original flyash at 325 degrees C. The results indicate that formation of PCDD/PCDF on flyash deposits in the post-combustion plant of incinerators can result in the release of significant amounts of PCDD/PCDF to the flue gas stream.  相似文献   

20.
Huang H  Buekens A 《Chemosphere》2001,44(6):1505-1510
A kinetic model is developed for de novo synthesis of PCDD/F from carbon in incinerator fly ash. The main mechanistic steps considered in the model are carbon gasification, PCDD/F formation, desorption and degradation. Rate equations are derived which can relate PCDD/F formation with process variables including carbon concentration of fly ash, partial pressure of oxygen, reaction temperature and time. The kinetic model has been verified using laboratory de novo synthesis data reported in the literature. When the model is applied to industrial incinerator conditions, PCDD/F formation levels of 0.1-0.5 microg/N m3 in the gas phase and 0.1-1.2 microg/g in the solid phase are calculated, and both are in good agreement with incinerator measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号