共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Hudon G Guy C Hermia J 《Journal of the Air & Waste Management Association (1995)》2000,50(10):1750-1758
The possibility of using electronic noses (ENs) to measure odor intensity was investigated in this study. Two commercially available ENs, an Aromascan A32S with conducting polymer sensors and an Alpha M.O.S. Fox 3000 with metal oxide sensors, as well as an experimental EN made of Taguchi-type tin oxide sensors, were used in the experiments. Odor intensity measurement by sensory analysis and EN sensor response were obtained for samples of odorous compounds (n-butanol, CH3COCH3, and C2H5SH) and for binary mixtures of odorous compounds (n-butanol and CH3COCH3). Linear regression analysis and artificial neural networks (ANN) were used to establish a relationship between odor intensity and EN sensor responses. The results, suggest that large differences in sensor response to samples of equivalent odor intensity exist and that sensitivity to odorous compounds varies according to the type of sensors. A linear relationship between odor intensity and averaged sensor response was found to be appropriate for the EN based on conducting polymer sensors with a correlation coefficient (r) of 0.94 between calculated and measured odor intensity. However, the linear regression approach was shown to be inadequate for both ENs, which included metal oxide-type sensors. Very strong correlation (r = 0.99) between measured odor intensity and calculated odor intensity using the ANN developed were obtained for both commercial ENs. A weaker correlation (r = 0.84) was found for the experimental instrument, suggesting an insufficient number of sensors and/or not enough diversity in sensor responses. The results demonstrated the ability of ENs to measure odor intensity associated with simple mixtures of odorous compounds and suggest that ANN are appropriate to model the relationship between odor intensity measurement and EN sensor response. 相似文献
3.
Kikuo Oikawa Hiroko Saito Ikuei Kifune Tatsuo Ohshina Masami Fujii Yukio Takizawa 《Chemosphere》1982,11(9):943-951
To study atmospheric mercury absorption in human respiratory passage-ways, mercury in expired air was measured in three different states of breathing: steady breathing, deep breathing and breath held after inspiration.In this study, air containing mercury was inhaled through the nose and expired through the mouth. The concentration of mercury in the exhaled air was determined by the technique of gold-amalgam trapping, heat vaporization, and flameless atomic absorption measurement.The subjects were 13 male adults, aged 25–62 years, and 38 cases were observed. Four different concentrations of mercury, 1–3, 4–6, 10–11, and 20–30 μg/m3 were used, and absorption for each was determined. When the concentration was 1–3 μg/m3, the absorption was 74–92%, the average being 82.5%. At concentrations of 4–6, 10–11, and 20–30 μg/m3, the absorption was 76.6–100%, 75.5–99.2%, and 79.9–95.9% respectively, and the average was 88.8%, 85.2%, and 87.7% respectively.A slightly higher rate of mercury absorption was observed in deep breathing than in steady breathing, and when expiration was suppressed for some time after inspiration, the rate increased remarkably to 97.4–99.7%. Prolonged retention of inhaled air containing mercury in the respiratory tract is believed to have caused the increased absorption. 相似文献
4.
5.
6.
7.
8.
Fred L. Hartley C. C. Moore J. B. Gregory 《Journal of the Air & Waste Management Association (1995)》2013,63(2):143-146
Demands for high performance and reliability of electrostatic precipitators for collection of fly ash from low sulfur fuels has led to rapid escalation of sizes and uncertainties in sizings of cold-side precipitators. This has led to utilization of the so-called “hot-side” precipitator. The underlying concept of hot-side precipitation is the avoidance of the necessity to operate the precipitator under high resistivity conditions. Data on in-situ measurements of resistivity of low sulfur fuel ash, as well as performance parameters of a number of operating installations, will be reviewed. These data will demonstrate the reduced sensitivity of hot-side precipitator sizing to fuel conditions. Other advantages of hot-side precipitators will be discussed. Operating experience with hot-side precipitators has focused on structural problems which are peculiar to the larger, higher temperature installations. The nature and solution of these problems will be discussed. General comparative economics of hot-side and cold-side precipitators as they relate to fuel properties will be reviewed. 相似文献
9.
Anne M. Gorsuch 《Journal of the Air & Waste Management Association (1995)》2013,63(12):1195-1197
The following remarks were presented by Mrs. Gorsuch at the Acid Rain Symposium conducted by the Pittsburgh Chamber of Commerce on October 6, 1982. 相似文献
10.
A general introduction of the bait-lamina test has been made in this article. This article has an introductional character for other articles dealing with the bait-lamina test method and gives the experimental data. The test was first introduced by Törne in 1990 to measure the biological activity of soil. It enables the monitoring of biotic (microbial and zootic) processes in the soil within a short period of time, and detailed investigations. The test system is based on visual assessment of feeding on small portions of thin laminated bait substrate exposed to edaphic processes. The test system has found its application mainly in Germany but in the meanwhile also in Portugal, Switzerland and in the Netherlands in laboratories of soil ecology and soil ecotoxicology. At present there are only few publications in the international literature, but the interest in this method is growing. During the past years two workshops on the subject have been organized in Germany to summarize experiences with and to evaluate the test system and optimize the standard procedure. 相似文献
11.
12.
13.
14.
The information on this page is reprinted with permission from “Guide for Professional Engineers’ Services”, published by the Professional Engineers in Private Practice Division of the National Society of Professional Engineers. The publication was designed “as a guide for selecting and engaging professional engineers in private practice and compensating them for their services”. It is available from the National Society of Professional Engineers, 2029 K Street, N.W., Washington, D.C. 20006. 相似文献
15.
16.
17.
18.
Herwig Hulpke Ute Müller-Eisen 《Environmental science and pollution research international》1997,4(3):146-153
Environmentally sound manufacture does not have its source only in developing and improving the techniques for treating solid,
liquid and gaseous wastes at the end of the production process. Our experience shows that more effort and capital budgets
must be devoted to developing preventive measures. Although the treatment techniques have become very advanced and meet ecological
requirements to a very high degree, they are now reaching the limits of their technological and economic feasibility. Environmental
protection at the production site has undergone structural change in recent years. The emphasis has shifted to preventive
techniques which affect the production process itself, avoiding the emergence of waste at the “end of the pipe” by preventing
its formation or recycling it straight away. This integrated approach is in harmony with the demands of sustainable production.
The functions of in-process environmental protection measures need to be looked at as a whole from the points of view of both
environmental protection and cost-effectiveness. Some integrated methods are described. 相似文献
19.