首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An TC  Zhu XH  Xiong Y 《Chemosphere》2002,46(6):897-903
The photoelectrochemical degradation of methylene blue in aqueous solution was investigated with three-dimensional electrode-photocatalytic reactor. It was found that the methylene blue could be degraded more efficiently by photoelectrochemical process than by photocatalytic oxidation or electrochemical oxidation alone. The decolorization efficiency and COD reduction were 95% and 87% for a photoelectrochemical process, respectively, while they were only 78% and 68% for a single electrochemical process and 89% and 71% for a single photochemical process. The TOC reduction of the former also reached as high as about 81% within a reaction time of 30.0 min. And these degradation reactions conformed to pseudo-first-order kinetics.  相似文献   

2.
电解氧化处理难降解垃圾渗滤液研究   总被引:1,自引:1,他引:0  
采用连续式电解槽对垃圾渗滤液进行电解催化处理,考察极板间距、电流密度、电导率[Cl-]浓度对电解效果的影响.结果表明,当添加的[Cl-]6000 mg/L,在电解60 min时,对初始COD小于3000 mg/L的中等浓度渗滤液有较好的处理效果,COD和NH3-N的去除率分别达88.9%和97.3%,能耗为2.75 kwh/m3.为中试和工业设计应用提供了参考.  相似文献   

3.
用聚硅酸铁铝对垃圾渗沥液进行预处理的研究   总被引:6,自引:0,他引:6  
采用一种新型高效的无机高分子混凝剂——聚硅酸铁铝(PSAF)用于垃圾渗沥液亚滤装置的预处理。结果表明,在PSAF的投加量为150mg/L,pH为5.0和沉降时间为60min的条件下,混凝效果最佳,浊度去除率可达92%左右,色废去除率可达91%左右,CODcr去除率可达70%左右。同时探讨了该混凝剂处理垃圾渗沥液的反应机理。  相似文献   

4.
Coagulation-flocculation pretreatment of sanitary landfill leachates   总被引:15,自引:0,他引:15  
Sanitary landfill leachates are considered as heavily polluted industrial wastewaters, presenting significant time and spatial variations of their physical-chemical parameters. Special care is required for their efficient treatment and disposal. The main aim of this work was to examine the application of coagulation-flocculation for the treatment of raw and partially stabilized leachates. Jar-test experiments were employed in order to determine the optimum conditions for the removal of organic matter and color, i.e. coagulant-flocculant combination, effective dosage and pH control. Ferric chloride, aluminium sulphate and lime were tested as conventional coagulants, whereas four commercial polyelectrolytes were co-examined: one anionic, two cationic and a non-ionic polymer. High chemical oxygen demand (COD) removal capacities (about 80%) were obtained during the addition of ferric chloride to the partially stabilized leachates, whereas low COD reductions (i.e. lower than 35%) were measured during the addition of coagulants in the raw samples. The addition of polyelectrolytes and pH adjustment in the alkaline region were found to affect slightly the removal of pollutants. The physico-chemical process may be used as a useful pretreatment step, especially for fresh leachates, prior to biological treatment, or as a post-treatment (polishing) step for partially stabilized leachates.  相似文献   

5.
Physical-chemical methods have been suggested for the treatment of low strength municipal landfill leachates. Therefore, applicability of nanofiltration and air stripping were screened in laboratory-scale for the removal of organic matter, ammonia, and toxicity from low strength leachates (NH4-N 74-220 mg/l, chemical oxygen demand (COD) 190-920 mg O2/l, EC50 = 2-17% for Raphidocelis subcapitata). Ozonation was studied as well, but with the emphasis on enhancing biodegradability of leachates. Nanofiltration (25 degrees C) removed 52-66% of COD and 27-50% of ammonia, the latter indicating that ammonia may in part have been present as ammonium salt complexes. Biological pretreatment enhanced the overall COD removal. Air stripping (24 h at pH 11) resulted in 89% and 64% ammonia removal at 20 and 6 degrees C, respectively, the stripping rate remaining below 10 mg N/l h. COD removals of 4-21% were obtained in stripping. Ozonation (20 degrees C) increased the concentration of rapidly biodegradable COD (RBCOD), but the proportion of RBCOD of total COD was still below 20% indicating poor biological treatability. The effect of the different treatments on leachate toxicity was assessed with the Daphnia acute toxicity test (Daphnia magna) and algal growth inhibition test (Raphidcocelis subcapitata). None of the methods was effective in toxicity removal. By way of comparison, treatment in a full-scale biological plant decreased leachate toxicity to half of the initial value. Although leachate toxicity significantly correlated with COD and ammonia in untreated and treated leachate, in some stripping and ozonation experiments toxicity was increased in spite of COD and ammonia removals.  相似文献   

6.
An integrated technique consisted of ozonation and coagulation/flocculation processes was studied, aiming to provide an efficient method for the treatment of stabilized/biologically pre-treated leachates, in order to reduce the organic pollutants' content to concentration values lower than the corresponding limits, imposed by the legislation. Leachates were collected from a municipal landfill site; samples containing around 1000 mg l(-1) COD and BOD(5)/COD ratio about 0.17 were treated by using two different processes or combinations between them, i.e. ozonation, coagulation-flocculation, ozonation followed by coagulation/flocculation and coagulation/flocculation followed by ozonation. The application of single ozonation resulted to the efficient removal of color and organic loading, due to the respective oxidation, induced by ozonation; however, COD values lower than 200 mg l(-1) could be only achieved after prolonged reaction times and for high ozone production rates. The coagulation of leachate samples was studied by the addition of ferric chloride or poly-aluminum chloride agents at various dosages. Maximum COD removal rates (up to 72%) were achieved by the addition of 7 mM Fe, or of 11 mM Al respectively. However, final COD values higher than 200 mg l(-1) were obtained indicating the requirement of an additional treatment step. Pre-ozonation followed by coagulation/flocculation was not found to be an efficient treatment approach for this aim, but coagulation/flocculation followed by ozonation, was proved to be an efficient process for the reduction of COD to lower than 180 mg l(-1).  相似文献   

7.
微絮凝 -直接过滤工艺是一种将混凝反应、沉淀截留集中在同一滤柱内同步完成的高效水处理工艺。该工艺应用于城市污水的深度处理中 ,通过絮凝剂的加入 ,具有同步去除PO3 -4 P、SS和部分COD的功能。本文研究了该工艺对二级处理出水中PO3 -4 P、SS和COD的去除效果及其规律。研究表明 :采用聚合氯化铁 (PFC)作为絮凝剂 ,当Fe/P摩尔比为 2∶1时 ,水中PO3 -4 P的去除率达 98.8% ,浓度可降至 0 .1mg/L以下 ,同时SS、COD去除率也有明显提高。与传统的混凝、沉淀除磷工艺相比 ,该工艺具有操作简单、结构紧凑、占地面积小、污泥量少等优点 ,是一种更为经济和简单的处理单元 ,适用于现有城市污水处理厂的除磷和进一步提高水质的深度处理  相似文献   

8.
Laboratory-scale experiments were conducted in order to investigate the effect of ozone as pre-aerobic treatment and post-aerobic treatment for the treatment of the distillery wastewater. The degradation of the pollutants present in distillery spent wash was carried out by ozonation, aerobic biological degradation processes alone and by using the combinations of these two processes to investigate the synergism between the two modes of wastewater treatment and with the aim of reducing the overall treatment costs. Pollutant removal efficiency was followed by means of global parameters directly related to the concentration of organic compounds in those effluents: chemical oxygen demand (COD) and the color removal efficiency in terms of absorbance of the sample at 254 nm. Ozone was found to be effective in bringing down the COD (up to 27%) during the pretreatment step itself. In the combined process, pretreatment of the effluent led to enhanced rates of subsequent biological oxidation step, almost 2.5 times increase in the initial oxidation rate has been observed. Post-aerobic treatment with ozone led to further removal of COD along with the complete discoloration of the effluent. The integrated process (ozone-aerobic oxidation-ozone) achieved approximately 79% COD reduction along with discoloration of the effluent sample as compared to 34.9% COD reduction for non-ozonated sample, over a similar treatment period.  相似文献   

9.
生活垃圾焚烧发电厂渗滤液蒸发浓缩处理   总被引:1,自引:0,他引:1  
垃圾焚烧厂渗滤液因水质复杂,NH3-N、COD和电解质含量高等特点,成为一种难处理有机废水。采用负压蒸发浓缩法对渗滤液及电絮凝预处理渗滤液的处理进行了对比研究,并考查了浓缩比、pH等因素的影响。研究结果表明,电絮凝预处理不能改变渗滤液中COD、NH3-N的蒸发去除规律,即蒸发处理过程中,蒸发冷凝液中COD在蒸发前期和后期含量较高,蒸发中期较低;而NH3-N含量在蒸发处理前期较高,中后期含量较低。pH对蒸发处理影响较大,在酸性pH下COD去除率较低,但NH3-N去除率较高,可达95%以上,而在中碱性pH下,COD去除率增高,NH3-N去除率降低。渗滤液及电絮凝预处理渗滤液的一次蒸发冷凝液,经过二次蒸发处理后,冷凝液中COD和NH3-N含量均能达到一级排放标准,即分别低于100 mg/L和15 mg/L。  相似文献   

10.
Dyeing wastewater was known to have strong color and refractory organic pollutants. In this study irradiation alone was used for dyes wastewater treatment. This paper studies the effect of the concentrations of pollutants to its removal at various dosages using electron beam technology. Irradiation was effective in removing the highly colored and refractory organic compounds. The color removal for initial concentrations of 255 CU, 520 CU, 990 CU and 1900 CU treated using irradiation at 0.5kGy were 61%, 48%, 28% and 16%, respectively. However, at the dose of 108kGy and higher, the color removal between 87% and 96% were recorded with no apparent trend. COD removal also reported similar trend but at relatively lower removal percentage. The COD removal at 0.5kGy for initial COD concentrations of 57mg/l and 515mg/l were 10% and 0%, respectively. At irradiation dose of 108kGy, the removal for initial COD concentrations of 57mg/l and 515mg/l were 37% and 13%, respectively. This showed that concentrations of pollutants and dose of irradiation applied to remove color and COD were dependent to each other.  相似文献   

11.
通过采用铁碳微电解-Fenton法预处理苯胺基乙腈生产废水的实验研究,分析了处理过程的COD降解动力学;同时研究了单纯活性炭吸附和微电解过程中COD去除率的变化。结果表明,铁碳微电解的初期COD降解过程近似符合一级反应动力学,并且得到微电解与活性炭吸附对铁碳微电解降解COD的关系式;Fenton反应中通过研究有机物浓度和过氧化氢初始浓度与反应进程的关系,建立了反应动力学模型;单纯吸附实验COD去除率在24 h内快速下降,而微电解在相应时间内COD去除率波动较小,为实际应用提供了数据经验和理论依据。  相似文献   

12.
采用超声波-膜生物法(MBR)联合处理垃圾渗滤液,探讨了超声波辐射时间和MBR的水力负荷对COD、NH3-N和TP去除的影响。结果表明,(1)超声波单独处理时,超声波辐射时间在30~90 s时,COD、NH3-N最大增加率分别34.31%、3.36%,而对TP的去除没有影响;(2)超声波-膜生物(MBR)联合处理时,超声波辐射时间为300 s,MBR的水力负荷为6.4 L/(m2.d)时,COD、NH3-N和TP的最佳去除率分别为92.20%、80.10%和91.12%;MBR的水力负荷为12.8 L/(m2.d),超声波辐射时间在5~20 min时,COD、NH3-N的最佳去除率分别为92.34%、79.93%,TP的浓度低于0.2 mg/L;MBR反应时间为7 h,超声波辐射时间为5~20 min,与未进行超声波辐射处理(超声波辐射时间为0 min)相比,COD、NH3-N的去除率增加了11.37%、15.26%;超声波预处理有助于提高后续MBR对COD、NH3-N的去除作用。  相似文献   

13.
根据广州从化市玮思工业园排放的综合污水的特点,设计了生物接触氧化—复合人工湿地组合工艺对其进行处理,考察了该工艺运行一年来对COD、BOD5、TP、NH4+ -N、TN的去除效果.结果表明,该组合工艺对工业园区综合污水中的COD、BOD5、TP、NH4+ -N和TN都有较好的去除效果,出水COD、BOD5、TP、NH4+ -N、TN的平均去除率分别为86.07%、74.91%、60.73%、89.62%、46.01%;该组合工艺对各污染物的去除效果明显优于单一的生物接触氧化池和单一的复合人工湿地的去除效果,生物接触氧化池对COD、BOD5和NH4+ -N的去除贡献较大,但对TP和TN的去除能力有限;采用该组合工艺处理工业园区综合污水,具有运行费用低、处理效果好、操作方便、管理简单、景观效果良好等优点.  相似文献   

14.
活性污泥与生物膜复合工艺处理石化废水的研究   总被引:1,自引:0,他引:1  
实验研究了活性污泥与生物膜复合工艺(HP)对石化废水的处理效果,并与活性污泥工艺(ASP)进行对比研究.结果表明,HP对石化废水中COD的去除效果略好于ASP,而对NH3-N的去除效果明显优于ASP.另外,两种工艺对硫化物和油的去除效果类似.提高进水负荷时,HP表现出较强的耐冲击负荷能力.以2L/h连续运行时,石化废水...  相似文献   

15.
A novel nanosize metallic calcium/iron dispersed reagent was synthesized and tested as coagulant/catalyst in a hybrid zero valent iron (ZVI)/H2O2 oxidation process to treat leachate. Two different types of leachates, one from municipal solid waste (MSW) tipping hall (MSWIL) and second from an MSW landfill site (MSWLL), were collected and characterized. The morphology, elemental composition, and mineral phases of the nano-Ca/CaO and nano-Fe/Ca/CaO were characterized by scanning electron microscopy–electron dispersive spectroscopy (SEM-EDS) and x-ray powder diffraction (XRD) analysis. The coagulation process with 2.5 g L?1 nano-Ca/CaO attained 64.0, 56.0, and 20.7% removal of color, chemical oxygen demand (COD), and total suspended solids (TSS) in MSWLL. With only 1.0 g L?1 of nano-Fe/Ca/CaO, relatively high color, COD and TSS removal was achieved in MSWLL at 67.5, 60.2, and 37.7%, respectively. The heavy metal removal efficiency reached 91–99% after treatment with nano-Fe/Ca/CaO in both leachate samples. The coupling process, using 1.0 g L?1 of nano-Fe/Ca/CaO and 20 mM H2O2 doses, achieved enhancement removal of color, COD, and TSS, up to 95%, 96%, and 66%, respectively, without initial pH control. After this treatment, the color, COD, TSS, and heavy metals were significantly decreased, fitting the Korean discharge regulation limit. A hybrid coupled zero valent iron (ZVI)/H2O2 oxidation process with novel nanosized metallic calcium/iron dispersed reagent proved to be a suitable treatment for dealing with leachate samples.

Implications: Conventional treatments (biological or physicochemical) are not sufficient anymore to reach the level of purification needed to fully reduce the negative impact of landfill leachates on the environment. This implies that new treatment alternatives species must be proposed. A coupled zero valent iron (ZVI)/H2O2 oxidation process proved to be a suitable treatment for dealing with leachate samples. Coagulation with nFe/Ca/CaO allows 91–99% of heavy metals removal. The coupled coagulation–oxidation process by nFe/Ca/CaO reveals excellent ability to treat leachate. After coupled treatment the color, COD, and TSS were also much lower than the discharge regulation limit.  相似文献   

16.
Liou RM  Chen SH  Hung MY  Hsu CS  Lai JY 《Chemosphere》2005,59(1):117-125
FeIII supported on resin as an effective catalyst for oxidation was prepared and applied for the degradation of aqueous phenol. Phenol was selected as a model pollutant and the catalytic oxidation was carried out in a batch reactor using hydrogen peroxide as the oxidant. The influent factors on oxidation, such as catalyst dosage, H2O2 concentration, pH, and phenol concentration were examined by considering both phenol conversion and chemical oxygen demand (COD) removal. The FeIII-resin catalyst possesses a high oxidation activity for phenol degradation in aqueous solution. The experimental results of this study show that almost 100% phenol conversion and over 80% COD removal can be achieved with the FeIII-resin catalyst catalytic oxidation system. A series of prepared resin were investigated for improving the oxidation efficiency. It was found that the reaction temperature and initial pH in solution significantly affected both of phenol conversion and COD removal efficiency. The activity of the catalyst significantly decreased at high pH, which was similar to the Fenton-like reaction mechanism. Results in this study indicate that the FeIII-resin catalytic oxidation process is an efficient method for the treatment of phenolic wastewater.  相似文献   

17.
以某城市污水厂进水为研究对象,采用A2/O+硫磺填料反应柱组合工艺,考察其对COD、总氮、总磷以及溶解性磷处理效果的改善。组合工艺出水水质稳定后,连续运行55 d,并对工艺的出水进行常规指标分析。结果表明:组合工艺的脱氮除磷效果较单个A2/O工艺都得到了较大的改善,而COD去除效果变化不大。A2/O系统对COD有良好的去除效果,出水的COD平均去除率能达到94%;TN和TP去除效果相对较差,出水平均去除率分别为60%和57.4%。经硫磺填料反应柱的脱氮除磷作用,系统出水TN去除率提高到84%,TP去除率提高到69.8%,COD去除率变化不大,升高到95.3%。  相似文献   

18.
以某城市污水厂进水为研究对象,采用A2/O+硫磺填料反应柱组合工艺,考察其对COD、总氮、总磷以及溶解性磷处理效果的改善。组合工艺出水水质稳定后,连续运行55 d,并对工艺的出水进行常规指标分析。结果表明:组合工艺的脱氮除磷效果较单个A2/O工艺都得到了较大的改善,而COD去除效果变化不大。A2/O系统对COD有良好的去除效果,出水的COD平均去除率能达到94%;TN和TP去除效果相对较差,出水平均去除率分别为60%和57.4%。经硫磺填料反应柱的脱氮除磷作用,系统出水TN去除率提高到84%,TP去除率提高到69.8%,COD去除率变化不大,升高到95.3%。  相似文献   

19.
通过采用铁碳微电解-Fenton法预处理苯胺基乙腈生产废水的实验研究,分析了处理过程的COD降解动力学;同时研究了单纯活性炭吸附和微电解过程中COD去除率的变化。结果表明,铁碳微电解的初期COD降解过程近似符合一级反应动力学,并且得到微电解与活性炭吸附对铁碳微电解降解COD的关系式;Fenton反应中通过研究有机物浓度和过氧化氢初始浓度与反应进程的关系,建立了反应动力学模型;单纯吸附实验COD去除率在24h内快速下降,而微电解在相应时间内COD去除率波动较小,为实际应用提供了数据经验和理论依据。  相似文献   

20.
COD对强化生物除磷系统的影响及OUR的变化规律   总被引:2,自引:1,他引:1  
以实际生活污水为研究对象,在SBR系统中采用厌氧/好氧运行方式,考察强化生物除磷(EBPR)系统中好氧阶段COD浓度对聚磷菌除磷性能的影响以及不同好氧阶段COD浓度下的OUR变化规律.实验分4个阶段进行,分别为不投加外碳源、厌氧结束时投加不同体积的乙酸钠作为外碳源,使COD分别提高50、100和300mg/L.4种工况...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号