以钢铁厂和有色金属行业排放的PM2.5为研究对象,基于离散相模型DPM(Discrete Phase Model),并加入UDF自定义编程,研究高梯度磁场下不同入口风速、颗粒粒径、外磁场强度、磁性纤维磁感应强度以及磁化率对捕集效率的影响,并结合颗粒运动轨迹和受力情况对其进行分析.结果表明:当0.5μm≤dp≤2.5μm,v=0.1m/s时,利用高梯度磁场(H=0.1T,B=0.06T)可以使单纤维捕集PM2.5的效率提高为原来的4.23倍,得出磁性纤维周围存在2个引力区和2个斥力区.同时,在高梯度磁场中磁性纤维对PM2.5的捕集效率随入口风速呈先减小后趋于平稳的规律;而捕集效率随粉尘粒径呈先增大后减小的规律.当dp=1.0μm时的捕集效率提升最大,无论是外磁场强度还是磁性纤维磁感应强度,磁性纤维对颗粒的捕集效率与场强都呈一次函数关系,效率增长率KB>KH;随着颗粒磁化率的增加,磁性纤维对颗粒的捕集呈现两段线性增长规律,前后两段效率增长率K1>K2.当颗粒经过高梯度磁场区域时,入口风速、粉尘粒径、场强对运动轨迹影响较大,而磁化率对运动轨迹影响较小.  相似文献   

2.
为了进一步实现超低排放,针对钢铁冶金以及铸造行业生产过程中产生的Fe基细颗粒,提出驻极体磁纤维提高对微细颗粒捕集的方法.本文基于计算流体力学-离散相模型(CFD-DPM)分别研究了纤维荷电量、颗粒预荷电电场强度、纤维磁感应强度以及颗粒磁化率对驻极体磁纤维捕集性能的影响.结果表明:在驻极体磁纤维周围颗粒所受到的磁场力相对于库仑力受距离影响更加明显,磁场力只在纤维附近极短距离内作用明显.捕集效率与纤维荷电量以及预荷电电场强度呈线性关系,对于0.5 μm颗粒,捕集效率随纤维荷电量以及预荷电电场强度的增长速率低于2.5 μm的颗粒.当颗粒粒径为0.5~1.0 μm时,增大驻极体磁纤维的磁感应强度以及提高颗粒磁化率对于捕集效率的提高作用较小.当颗粒粒径为1.5~2.5 μm时,增大驻极体磁纤维的磁感应强度以及提高颗粒磁化率能够明显提高纤维的捕集效率.  相似文献   

3.
为研究非球形颗粒在磁场中被磁性纤维捕集的动力学行为,以钢铁行业炼钢过程中转炉和精炼炉中排放的转炉灰和精炼灰等两种粉尘为基础,利用形状系数计算公式得出的φ=0.21,0.78,0.81,1.00分别表示圆片形(厚度H=底面圆直径d/40),椭球形(x轴赤道半径:y轴赤道半径:z轴极半径=a:b:c=1:1:4),正方体形,球形颗粒,并对其进行研究.模拟结果表明,相同工况参数下,当形状系数接近时,捕集效率和运动轨迹与粉尘颗粒具体表现的形状特征无关.在传统单纤维捕集过程中,当入口风速v=0.1m/s,dp>2.0μm时,形状系数相差越大,捕集效率差距越大.形状系数对颗粒被捕集影响程度大小与单纤维捕集效率增减呈正相关;在磁性纤维产生的磁场中v=0.1m/s,dp>0.5μm时,形状系数相差越大,捕集效率差距越大.φ≥0.4时,捕集效率随形状系数的增加趋于稳定,形状系数对颗粒被捕集影响程度大小与单纤维捕集效率增减无关;在高梯度磁场中v=0.1m/s,dp=1.0μm时,形状系数相差越大导致捕集效率之间差距越大的规律越明显.当v=0.1m/s,0.5μm≤dp≤2.5μm时,形状系数对颗粒被捕集影响程度的大小与单纤维捕集效率增减呈正相关.  相似文献   

4.
采用数值方法求解了描述椭圆截面纤维绕流特征的Navier-Stokes方程,并计算了椭圆纤维对粒子惯性捕集效率及纤维过滤压降.分析讨论了椭圆纤维迎风角度θ、长短轴比ε和填充率C等参数对惯性粒子过滤性能的影响.结果表明,在大迎风角度时,过滤压降随长短轴比增大而增大,而在小迎风角度下,过滤压降则随长短轴比增大而减小;在相同纤维长短轴比条件下,过滤压降均随迎风角增大而增加.粒子惯性捕集效率计算结果则表明,对于中高惯性粒子捕集,大迎风角度和高长短轴比的椭圆纤维的捕集效率高于圆截面纤维,而对弱惯性粒子,小迎风角度和高长短轴比的椭圆纤维则表现出较高的捕集效率.在椭圆纤维过滤压降和捕集效率计算基础上,采用纤维过滤质量因子(定义为捕集效率比过滤阻力)评价综合过滤性能.结果表明,对于中高惯性粒子过滤,扁长型椭圆纤维(即为高长短轴比ε)在迎风角约为θ=45°时质量因子总体较高,即具有较优的综合过滤性能;而对弱惯性粒子,则扁长型椭圆纤维长轴平行来流方向(θ=0°)时,总体过滤性能较优.  相似文献   

5.
基于随机多层纤维过滤介质算法建立了平板式三维拟态化结构.利用计算流体力学-颗粒群平衡模型(CFD-PBM)对多纤维捕集过程中细颗粒湍流团聚进行数值模拟研究,并采用分区法求解颗粒群平衡方程(PBE).通过控制变量法分析表明:多纤维捕集过程中存在着明显的颗粒团聚行为.粉尘颗粒的团聚程度随停留时间增加而增强,当tl/v(速度方向模型尺寸长度/入口风速),团聚逐渐趋于稳定;当vmax·tl,入口风速越大,颗粒团聚程度和团聚速率越大,最终的团聚程度取决于入口风速和停留时间;颗粒粒径越大,粉尘颗粒的团聚程度和团聚速率越小.出口颗粒平均粒径与初始粒径相比增长倍数越小.粉尘颗粒体积分数越大,颗粒团聚程度以及团聚速率越大.当v=0.1m/s,dp=1.0μm,VF >0.003636,Bin-7~Bin-0区间数量浓度对数分布呈线性比例关系.  相似文献   

6.
运用数值模拟和实验测试方法,研究了住宅厨房在油烟机和送风气幕作用下的气流流动、温度分布和污染物扩散机理,并通过CFD数值计算对比分析了射速在0~5m/s范围的空气幕对厨房污染物扩散的影响.结果表明,单独使用抽油烟机作为厨房排风系统无法有效地将烹饪产生的油烟快速排向室外.空气幕作为补风装置应用在厨房通风系统不仅可以降低厨房空气温度,提高人体热舒适,而且能合理组织气流流动,降低厨房污染物浓度.然而,当油烟机排风量一定时,空气幕射速并非与油烟机捕集效率成正比,而是存在着最佳设计风速,排风速率为5m/s的最佳空气幕射速为0.6m/s.当通过增加油烟机排风量来提高捕集效率时,应根据不同的排风量确认对应的空气幕射速.  相似文献   

7.
针对亚微米颗粒(0.1~0.5μm)在单纤维捕集过程中的布朗团聚规律,基于计算流体动力学-颗粒群平衡模型(CFD-PBM)对粉尘颗粒在单纤维捕集过程中的布朗团聚行为进行了数值模拟研究,采用分区法对颗粒群平衡方程(PBE)进行求解,综合考虑了停留时间、入口粉尘粒径、气流温度、Pe数对布朗团聚的影响,并将数值模拟与实验结果进行对比.结果表明,布朗团聚核UDF符合数值模拟计算要求.粉尘颗粒的布朗团聚贯穿整个过程,团聚有效时间t=L/v(速度方向模型尺寸长度/入口流速);粉尘颗粒越小,布朗团聚越强,Bin-7与Bin-0区间的数量浓度差距越小,粒径与布朗团聚强度呈负相关;气流温度是通过改变气流动力黏度以及聚并系数来影响布朗团聚,与布朗团聚强度呈正相关,当T=300K,dp≥0.5μm时,颗粒的布朗团聚效应可以忽略;Pe数通过扩散系数的变化影响布朗团聚,与布朗团聚强度呈负相关.  相似文献   

8.
采用数值方法求解了描述交错排列纤维模型过滤器绕流特征的Navier-Stokes方程,并计算分析了纤维表面粒子的惯性捕集效率和单纤维过滤阻力.结果指出,在填充率C0.045时,Happel过滤阻力模型与数值结果十分吻合,优于Kuwabara模型给出的估计;当纤维填充率00.08时,Kuwabam模型的预测结果与数值结果更接近.通过追踪粒子的运动轨迹计算了单纤维的惯性捕集效率,讨论了过滤风速、粒子密度和填充率对粒子惯性捕集效率的影响.结果表明,粒子的惯性捕集作用存在某一临界粒子直径,小于临界直径的粒子将不被捕集;根据数值分析结果,分别给出了一个可适用于单纤维阻力估计的关系式和惯性捕集效率的计算公式,其适用参数范围为St≤10(StokeS数)和0.01C0.1.  相似文献   

9.
为了分析分布指数对线板式静电除尘器(ESP)中PM2.5捕集性能的影响,给出了基于电磁场、流场和颗粒动力场的数学模型,数值模拟了PM2.5分级效率、综合效率分别与分布指数的变化关系,比较了有无离子风和磁场作用时PM2.5的捕集性能。结果表明:数值模型与D-A公式相比具有较高的计算精度;离子风和外加磁场均能提升PM2.5的捕集性能,且捕集效率均随着分布指数的增大而逐步降低,为进一步提升ESP捕集性能提供技术参考。  相似文献   

10.
为研究气溶胶在自然界不同倾角岩体裂隙中的穿透率,对理想模型进行了理论分析计算,并在实验室用钢板制做模拟裂隙置于不同角度进行实验。结果表明:实测值与修正后的理论计算值吻合较好,对于有一定倾角的规则尺寸岩体裂隙可以通过修正后的理论计算公式得到气溶胶在其中的穿透率;随着水平倾角的交替改变(-90°~90°),气溶胶穿透率呈现周期性变化,随着相对角度(0°~90°,0°~-90°)的增加,气溶胶穿透率明显上升,且大粒径粒子尤为明显,小粒径粒子受角度影响较小;随着侧面倾角增大(0°~90°),气溶胶粒子穿透率逐渐上升(尤其是大粒径气溶胶粒子);裂隙呈水平状态时,气溶胶在其中的穿透率最低。裂隙倾角变化,对小粒径气溶胶粒子穿透率影响不大,对大粒径气溶胶粒子穿透率影响较为明显。  相似文献   

11.
We have developed a unified and comprehensive model for the overall efficiency of tubular inlets sampling from horizontal aerosol flows at 0–90° relative to the wind direction. In our model, derived from experimental data obtained in our wind tunnel, the transmission efficiency is separated into two components: one due to gravitational settling in the boundary layer and the other due to impaction. The gravitational settling component is determined by extending our previously developed isoaxial sampling model to nonisoaxial sampling. The impaction component is determined by a new model that quantifies the particle losses caused by direct wall impaction. The model also quantifies the additional particle losses resulting from the turbulent motion in the vena contracta which is formed in the inlet when the inlet velocity is higher than the wind velocity.The equation for the gravitational settling component considers the inertial behaviour of the particles by including the Stokes number, the flow development in the boundary layer by including the Reynolds number and the gravitational settling in the boundary layer by including a modified gravitational settling parameter. The equation for the impaction component considers direct wall impaction and the losses due to vena contracta formation through the Stokes number, velocity ration and sampling angle. Direct wall impaction is further differentiated by the gravity effect on the impaction process which distinguishes upward from downward sampling. Our equations for transmission efficiency in combination with aspiration efficiency equations determine the overall efficiency of tubular, sharp-edged inlets at all orientations of the inlet relative to horizontal aerosol flows.  相似文献   

12.
When sampling aerosols in ambient or industrial air environments with an inlet, small changes in wind direction or physical constraints in positioning the inlet in the system necessitate the assessment of sampling efficiency in both the vertical and horizontal planes at small angles. In this study we have experimentally investigated the overall sampling efficiency of tubular sharp-edged inlets in yaw (horizontal plane) and pitch (vertival plane) orientations at 0–20° from horizontal aerosol flows. We have developed a model for the overall sampling efficiency at yaw and pitch by extending our previously developed model for pitch to yaw based on our new wind tunnel data. In our model, the difference between yaw and pitch is expressed by the effect of gravity on the wall impaction process inside the inlet described by a gravity effect angle. At yaw, the gravity effect on the wall impaction process does not change with sampling angle. At pitch, the gravity effect on the impaction process results in particle loss increase for upward and decrease for downward sampling. A new relationship has been developed between the gravity effect and physical sampling angles.Using our model, we have developed graphical representations for aerosol sampling at small angles. These can be used in the field to determine the overall sampling efficiency of inlets at several operating conditions and the operating conditions that results in an acceptable sampling error. Pitch and diameter factors have been introduced for relating the efficiency values over a wide range of operating conditions to those of a reference condition. The pitch factor determines the overall sampling efficiency at pitch from yaw values, and the diameter factor determines the overall sampling efficiency at different inlet diameters.  相似文献   

13.
丛俊  王凤英  吴新 《环境科技》2008,21(1):20-22,26
在高梯度磁场中,分别对钡铁氧体、Fe3O4和γ-Fe2O3等3种磁性可吸入颗粒物进行了脱除实验研究.通过改变外加磁场磁通密度、格栅排数、气溶胶流量、磁性可吸入颗粒物的种类,研究其脱除效率的变化规律.确定影响磁性可吸入颗粒物脱除效率的因素.结果表明:外加磁场的磁通密度越大,颗粒物的脱除效率越高,但有一定限度;格栅排数增加后,颗粒物的脱除效率得到提高;随着流量的增加,颗粒物的脱除效率有所下降;磁性颗粒的磁化率越大.颗粒脱除效率越高.  相似文献   

14.
目的对临近空间大气中性风场进行监测与分析。方法借助法布里-珀罗干涉仪(Fabry-Perot Interferometer,FPI)观测临近空间顶层的大气中性风场。针对北极黄河站(78.92°N,11.93°E)临近空间顶层的大气中性风场,介绍全天空FPI测风的基本原理,通过对2016年11月25日全天空FPI设备观测的OI557.7 nm气辉干涉图进行分析,反演得到极光亚暴期间的内5级环的水平风场和视线风场。结果极地地区临近空间顶层的水平风速基本保持在-200~200 m/s之间,极光亚暴使得中性风场呈现出一定的方向性,并且风场增大的方向垂直于极光弧。结论利用全天空FPI设备可以对临近空间顶层的大气中性风场进行探测和分析,有助于认识和理解临近空间大气环境。  相似文献   

15.
水力旋流分离器具有分离效率高、简单可靠、绿色经济等优点,被广泛应用于各种分离场景,特别是近年来在水处理领域得到诸多关注。概述了运行操作参数(进料流速、进料浓度、进料压力)、结构设计参数(溢流管插入深度、底流管直径、回流角)、旋流器构型种类(W型、抛物线型、圆柱形)对水力旋流器分离性能的影响。优化操作参数可增强水力旋流器分离效率;溢流管插入深度与圆柱体横截面直径比值(L0/D)为1.0时产生的流场更有利于分离;底流管直径存在最佳设计范围;旋流分离器与水源热泵联用吸入角为90°时效果最好。水力旋流器的分离作用在水处理过程中可以起到改善微生物聚集体性能(如提高污泥水解速率、提升沉降性能)、分离特定颗粒态微生物(如厌氧氨氧化菌颗粒污泥)、去除或回收特定密度物质(如悬浮有机物、泥砂、金属颗粒)等诸多作用,为水力旋流器在水处理领域的应用拓展了新的前景。  相似文献   

16.
风向对街道峡谷内污染物扩散的影响   总被引:2,自引:1,他引:1       下载免费PDF全文
采用Fluent软件,选用RNG k-ε湍流模型,对长高比为5的街道峡谷(简称街谷)在0°~90°风向下流场和污染物浓度场进行了数值模拟. 结果表明: 0°~75°风向时,街谷内流场呈明显的三维特性,90°风向时,流动表现出中长街谷的二维特点;风向对街谷内壁面污染物浓度的分布有显著影响,90°风向下的街谷壁面浓度最大,其次是45°风向,其余风向下的相对较小,污染物浓度的计算值与风洞试验值在趋势上吻合较好;壁面污染物浓度的分布由街谷内长度方向漩涡、来流冲角产生的进口回流及沿长度方向的流动所决定,壁面浓度的分布差异均可从附近的流场获得解释. 街道峡谷内长度方向的漩涡模拟过强会导致地面附近污染物浓度的计算值偏离试验值.   相似文献   

17.
针对恶劣海况下船舶洗涤塔倾斜的情况,利用船舶尾气净化小试试验台,开展了洗涤塔不同倾斜角度下对镁基吸收剂脱硫效率影响的实验,研究了液气比、入口SO2浓度、烟气量、浆液pH值、对洗涤塔内SO2脱除效率的影响.结果表明:脱硫效率随洗涤塔倾角度的增大而降低.脱硫效率随液气比的增大而升高,较低的液气比时倾斜角度对SO2脱除效率的影响更明显;脱硫效率随SO2入口浓度的增大而略微降低,入口SO2浓度较高时,SO2脱除效率的降低随倾斜角度的增加变化较为明显;相同液气比条件下,脱硫效率随塔内烟气量的增加而升高;脱硫效率随浆液pH值的增大而升高,低pH值时SO2脱除效率的降低随倾斜角度的增加变化较为明显.筛板-边壁环的加入可有效提高倾斜条件下洗涤塔的脱硫效率,倾斜角度为15°时,脱硫效率提高将约3%;倾斜角度为10°时,脱硫效率提高约5%;倾斜角度在5°以下时,脱硫效率可提高将近7%.  相似文献   