首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 251 毫秒
1.
Mass Concentration of ambient particulate matter with an aerodynamic diameter less than 10µm (PM10) are reported for the first time for a range of sites in Dublin City over a 6 month period from January 1st 1996 to June 30th 1996. PM10 gravimetric mass concentration measurements are made with low flow Partisol 2000 air samplers using an impaction type PM10 inlet and 47mm diameter glass fibre filters. In addition, much finer time resolution measurements (minimum sampling frequency of 30 minutes) are made using a tapered element oscillating microbalance (TEOM) PM10 mass monitor. These PM10 mass concentrations methods are also compared with mass concentration inferred using the standard black smoke method. Analysis of the ambient mass concentration data with reference to traffic density and meteorological influences are presented. Results for the first six months of 1996 show that the average PM10 values range from a high of 49 µg m-3 at the Dublin city centre site to 14 µg m-3 at one of the suburban sites. Intercomparison between PM10 and black smoke mass concentrations show that the relationship is site specific. Statistical analysis between PM10 levels and car traffic number show a positive correlation while a weak negative correlation is found between PM10 levels and rainfall amount, wind speed and air temperature.  相似文献   

2.
The Helsinki Metropolitan Area Council (YTV) is responsible for air quality monitoring in the Helsinki area. Air quality has been monitored periodically since the late 1950s. An automatic SO2 monitoring network was constructed in 1975 and TSP measurements were added in 1978. Since then the network has been expanded and currently five automatic multicomponent stations form the basis of the network monitoring SO2, NO, NO2, CO, PM10 and O3 concentrations. Manual TSP and PM10 measurements are also conducted. Mobile monitoring units are also being used as well as special measurement campaigns. The effects of air pollution on nature are studied in bioindicator monitoring. An air quality index is used in order to inform the public of the current air quality situation. Changes in air quality are reflected in monitoring strategy. SO2 concentrations have decreased in the past two decades. Annual averages in 1995 were at or below 5 µg/m3. Traffic is the major source for pollutants even though catalytic converters have lowered traffic emissions somewhat. The highest annual average NO2 concentration at an urban site was 49 µg/m3 in 1995, and there has been no clear change in NO2 levels. There has been a decreasing trend in CO concentrations. Maximum annual TSP and PM10 averages in 1995 were 92 and 32 µg/m3, respectively. The highest average lead concentration was 0.01 µg/m3. Elevated concentrations are experienced from time to time. During the spring daily TSP and PM10 concentrations can go up to around 300 and 150 µg/m3, respectively. This is caused by resuspension mainly due to street sanding. Also a major winter NO2 episode occurred in December 1995. The highest hourly NO2 concentrations reached 400 µg/m3.  相似文献   

3.
The blood lead levels of 568 New Jersey hazardous waste workers were determined at least once in the period 1984–1987. Workers almost always wore protective clothing in the field, which should have prevented exposure to lead. Therefore, despite their occupation, these workers are probably representative of the New Jersey suburban population in the mid-1980s. Blood lead levels ranged from 2.0–20.7 µg/dL, with an arithmetic mean value of 5.8 µg/dL, representing a decline from levels measured a decade earlier, but there was no clear change over the four years of the study. Blood lead levels increased with age of the worker up to age 60. Women showed lower levels than men in every age group.  相似文献   

4.
Levels of pollutants including PM2.5 and PM2.5 composition (black carbon and water soluble ions), SO(2), NO(2), CO, CO(2), and BTEX (benzene, toluene, ethylbenzene, xylene) were monitored for indoor and outdoor air at a university campus and a shopping center, both located in the Northern suburb of Bangkok. Sampling was done during December 2005-February 2006 on both weekdays and weekends. At the university, indoor monitoring was done in two different air conditioned classrooms which shows the I/O ratios for all pollutants to be below 0.5-0.8 during the weekends. However, on weekdays the ratios for CO(2) and most detected BTEX were above 1.0. The concept of classroom occupancy was defined using a function of the student number in a lecture hour and the number of lecture hours per day. Classroom 2, which had a higher occupancy than classroom 1, was characterized by higher concentrations of most pollutants. PM2.5 was an exception and was higher in classroom 1 (37 microg/m(3), weekdays) as compared to classroom 2 (26 microg/m(3), weekdays) which was likely linked to the dust resuspension from the carpeted floor in the former. Monitoring was also done in the shopping mall at three different sites. Indoor pollutants levels and the I/O ratios at the shopping mall were higher than at the university. Levels of all pollutants measured at the car park, except for toluene and CO(2), were the highest. I/O ratios of the pollutants at the mall were above 1.0, which indicates the relatively higher influence of the indoor sources. However, the black carbon content in PM2.5 outdoor is higher than indoor, which suggest the important contribution from outdoor combustion sources such as the traffic. Major sources of outdoor air pollution in the areas were briefly discussed. Exposure modeling was applied using the time activity and measured pollutant concentrations to assess the exposure of different groups of people in the study areas. High exposure to PM2.5, especially for the people working in the mall, should be of health effect concern.  相似文献   

5.
Concentrations of 16 priority polycyclic aromatic hydrocarbons (PAHs) were measured in 28 surface soils samples collected from Urumqi, northwest China, for examination of distributions, source contributions, and potential health effects. The results indicated that the sum of 16 PAHs concentration ranged from 331 to 15,799 μg?kg?1 (dw) in soils, with a mean of 5,018?±?4,896 μg?kg?1 (n?=?28). The sum of seven carPAHs concentration ranged from 4 to 1,879 μg?kg?1 (dw; n?=?28). The highest ∑PAHs concentrations were found at roadsides and industrial sites, followed by those at parks, rural areas, and business/residential areas. Coal combustion, emission of diesel and gasoline from vehicles, and petroleum source were four sources of PAHs as determined by PMF analysis, which contributed 51.19, 19.02, 18.35, and 11.42 % to the PAH sources, respectively. Excellent coefficients of correlation between the measured and predicted PAHs concentrations suggested that the PMF model was very effective to estimate sources of PAHs in soils. Incremental lifetime cancer risk values at the 95th percentile due to human exposure to surface soils PAHs in Urumqi were 2.02?×?10?6 for children and 2.72?×?10?5 for adults. The results suggested that the current PAHs levels in soils from Urumqi were pervasive and moderately carcinogenic to children and adults.  相似文献   

6.
The Oregon Department of Forestry is a designated management agency to provide a forestry program to assist in bringing the Tualatin River into complicance with pH and dissolved oxygen water quality standards. The Oregon Environmental Quality Commission set a total maximum daily load (TMDL) of 70 µg/l total phosphorus to control algae growth and meet these standards. The Department of Forestry has a basin effectiveness monitoring plan to determine that the Oregon Forest Practice Rules' BMPs are maintaining adequate control of phosphorus loadings from forest operations. Three sites monitored during May to October of 1990 were augmented by eight more sites in 1991. As laboratory methods were refined, the results became more accurate. The 1991 monitoring showed lower phosphorus levels that were consistent for each tributary. Mean total phosphorus levels ranged from 17 to 65 µg/l. Preliminary field reconnaissance suggests a correlation between phosphorus levels and underlying geology. Concentrations were lowest at sites underlain by tertiary intrusive basalts, next higher for sites with terrestrial basalt, next higher for one site with a basalt-sandstone bedrock mix, and highest for sites underlain predominately by sandstone. These results may be modified by 1992 monitoring and further analysis.  相似文献   

7.
The contamination of organochlorine pesticides hexachlorocyclohexane (HCH) and Dichlorodiphenyltrichloroethane (DDT) and their eco-environmental assessment in surface sediments from Lake Dongting, the second-largest freshwater lake in China, were studied. Concentrations of ∑HCH (=α-HCH + β-HCH + γ-HCH +δ-HCH) were 0.21--9.59 ng/g dry weight and those of ∑ DDT = p,p'-DDD+p,p'-DDE+o,p'-DDT+p,p'-DDT) ranged from under detectable limit to 10.15 ng/g dry weight. The ratios of α-HCH to γ-HCH were above 7 at most sampling sites while no or a small amount of β-HCH were found at all sites, suggesting the degradation of HCH used in the history and possibly current use of HCH in the region. The low ratios (below 2.0 in most cases) of (p,p'-DDE+p,p'-DDD) to p,p'-DDT and high levels of individual isomers of DDT at some sites also suggested that there have still been fresh inputs of DDT into Lake Dongting. Through the comparison between concentrations of HCH and DDT residues in sediments of Lake Dongting and those from other places in China and also from the results of our eco-environmental assessment, it can be concluded that Lake Dongting is the water body with high contamination of both HCH and DDT in its sediments in comparison with other water bodies in China.  相似文献   

8.
The NO, NO2 and N2O emission was measured, upon application of nitrate, ammonium and both, to four Belgian soils with different characteristics. The addition of NH 4 + caused higher NO and N2O emissions than the addition of no nitrogen, or the addition of NO 3 . In contrast to the two soils with a pH of approximately 8 the two soils with a pH around 6 showed a considerable delay in production of both NO and N2O upon the application of the ammonium, probably due to the lag-period of nitrification. The soils with a pH of 8 gave higher emissions on the application of NH 4 + than the soils with a pH of 6. The emission of NO2 was found to be considerably lower than the NO emission from the soils. The NO/NO2 ratio varied between 5–25 at considerable NO emissions (>50 nmol kg–1). In the controls of soil 1 and soil 2, which showed very low NO emissions ratios of <1 were observed. The N2O/NO ratios varied between 5–20 when NO emissions were considerable (>50 nmol kg–1). Soil 3 and 4 gave lower N2O/NO ratios than soil 1 and 2. In the controls of soil 1 and soil 2, at low NO emissions, N2O/NO ratios of >300 were observed. Soil 3 and 4 gave higher NO/NO2 and lower N2O/NO ratios than soil 1 and 2.  相似文献   

9.
Concentrations of black carbon and nitrogen dioxide have been collected concurrently using a MicrAeth AE-51 and an Aeroqual GSS NO(2) sensor. Forty five sampling events with a duration spanning between 16 and 22 hours have collected 10,800 5 min data in Birmingham (UK) from July to October 2011. The high temporal resolution database allowed identification of peak exposures and which activities contributed the most to these peaks, such as cooking and commuting. Personal exposure concentrations for non-occupationally exposed subjects ranged between 0.01 and 50 μg m(-3) for BC with average values of 1.3 ± 2.2 μg m(-3) (AM ± SD). Nitrogen dioxide exposure concentrations were in the range 相似文献   

10.
The concentrations of lead, cadmium and copper in roadside soil and plants in Elazig, Turkey were investigated. Soil samples were collected at distances of 0, 25 and 50 m from the roadside. The concentrations of lead, cadmium and copper were measured by Flame Atomic Absorption Spectrophotometry (FAAS). A slotted tube atom trap (STAT) was used to increase the sensitivity of lead and cadmium in FAAS. Lead concentrations in soil samples varied from 1.3 to 45 mg kg−1 while mean lead levels in plants ranged from120 ng g−1 for grape in point-4 to 866 ng g−1 for apple leaves in point-2. Lead analyses showed that there was a considerable contamination in both soil and plants affected from traffic intensity. Overall level of Cd in soil samples lies between 78 and 527 ng/g while cadmium concentration in different vegetations varied in the range of 0.8–98.0 ng g−1. Concentrations of copper in soil and plant samples were found in the range of 11.1–27.9 mg kg−1 for soil and 0.8–5.6 mg kg−1 for plants. Standard reference material (SRM) was used to find the accuracy of the results of soil analyses.  相似文献   

11.
The main objective of this work was to quantify and characterize the major indoor air contaminants present in different stages of a municipal WWTP, including microorganisms (bacteria and fungi), carbon dioxide, carbon monoxide, hydrogen sulfide ammonia, formaldehyde, and volatile organic compounds (VOCs). In general, the total bacteria concentration was found to vary from 60 to >52,560 colony-forming units (CFU)/m3, and the total fungi concentration ranged from 369 to 14,068 CFU/m3. Generally, Gram-positive bacteria were observed in higher number than Gram-negative bacteria. CO2 concentration ranged from 251 to 9,710 ppm, and CO concentration was either not detected or presented a level of 1 ppm. H2S concentration ranged from 0.1 to 6.0 ppm. NH3 concentration was <2 ppm in most samples. Formaldehyde was <0.01 ppm at all sampling sites. The total VOC concentration ranged from 36 to 1,724 μg/m3. Among the VOCs, toluene presented the highest concentration. Results point to indoor/outdoor ratios higher than one. In general, the highest levels of airborne contaminants were detected at the primary treatment (SEDIPAC 3D), secondary sedimentation, and sludge dehydration. At most sampling sites, the concentrations of airborne contaminants were below the occupational exposure limits (OELs) for all the campaigns. However, a few contaminants were above OELs in some sampling sites.  相似文献   

12.
This study measures the effect of emissions from an airport on the air quality of surrounding neighborhoods. The ambient concentrations of benzene, toluene, ethylbenzene, and o-, m-, and p-xylene (BTEX) were measured using passive samplers at 15 households located close to the airport (indoor, outdoor, and personal), at the end of airport runways and an out-of-neighborhood location. Measurements occurred over a 48-h period during summer 2006 and winter 2006?C2007. The average concentrations were 0.84, 3.21, 0.30, 0.99, and 0.34 ??g/m3 at the airport runways and 0.84, 3.76, 0.39, 1.22, and 0.39 ??g/m3 in the neighborhood for benzene, toluene, ethylbenzene, m-, p-, and o-xylene. The average neighborhood concentrations were not significantly different to those measured at the airport runways and were higher than the out-of-neighborhood location (0.48, 1.09, 0.15, 0.78, and 0.43 ??g/m3, each BTEX). B/T ratios were used as a tracer for emission sources and the average B/T ratio at the airport and outdoors were 0.20 and 0.23 for the summer and 0.40 and 0.42 for the winter, suggesting that both areas are affected by the same emission source. Personal exposure was closely related to levels in the indoor environment where subjects spent most of their time. Indoor/outdoor (I/O) ratios for BTEX ranged from 1.13 to 2.60 and 1.41 to 3.02 for summer and winter. The seasonal differences in I/O ratios reflected residential ventilation patterns, resulting in increased indoor concentrations of volatile organic compounds during winter.  相似文献   

13.
Surficial sediment samples collected from Kaohsiung Harbour and its nearby coast were analyzed for aliphatic hydrocarbons and parent polycyclic aromatic hydrocarbons (PAHs). According to our results, the average total concentrations of n-alkanes (n-C12 to C35) and aromatics (15 PAHs) were 4.33 µg g–1 dry weight (ranged 0.46–22.60) and 0.59 µg g–1 dry weight (ranged 0.09–1.75), respectively. The highest concentrations of aliphatic and aromatic hydrocarbons were recorded in stations near the estuaries of Qianzhen River and Love River, respectively. Aliphatic hydrocarbons in the samples indicate that there has been significant non-petrogenic, possibly terrestrial, contribution in the sediment of the open coast of Kaohsiung Harbour and that there has been dominant contribution from petrogenic sources in the sediment of the inner harbour. PAHs, detected in the samples, however, indicated a higher pyrolytic contribution in open-coast samples and a higher petrogenic contribution in the inner harbour. Overall, sediment concentrations of total alkanes in this study were comparable to those found in Victoria Harbour, Hong Kong and are higher than those found in Xiamen Harbour, China. Concentrations of total PAHs in inner Kaohsiung Harbour sediments were relatively lower than those found in Victoria Harbour, Hong Kong and Xiamen Harbour, China, but comparable to those found in Hsin-ta Harbour, Taiwan and Incheon Harbour, Korea. In comparison with several effect-based sediment quality guidelines, most PAH concentrations found in samples taken from inner harbour stations exceeded the Threshold Effect Level of Florida indicating a slight possibility of adverse effects.  相似文献   

14.
The aim of this study was to evaluate the indoor (I) and outdoor (O) levels of NO?, speciated volatile organic compounds (VOCs) and carbonyls at fourteen primary schools in Lisbon (Portugal) during spring, autumn and winter. Three of these schools were also selected to be monitored for comfort parameters, such as temperature and relative humidity, carbon dioxide (CO?), carbon monoxide (CO), total VOCs, and both bacterial and fungal colony-forming units per cubic metre. The concentration of CO? and bioaerosols greatly exceeded the acceptable maximum values of 1800 mg m?3 and 500 CFU m?3, respectively, in all seasons. Most of the assessed VOCs and carbonyls occurred at I/O ratios above unity in all seasons, thus showing the importance of indoor sources and building conditions in indoor air quality. However, it has been observed that higher indoor VOC concentrations occurred more often in the colder months, while carbonyl concentrations were higher in the warm months. In general, the I/O NO? ratios ranged between 0.35 and 1, never exceeding the unity. Some actions are suggested to improve the indoor air quality in Lisbon primary schools.  相似文献   

15.
The concentrations of organochlorine pesticides, PCBs, and PCDD/Fs were measured in sediment samples collected from the Gulf of Gdańsk, the Gdańsk Deep, the Vistula Lagoon and the off-shore waters in the southern Baltic Sea. The determinations were conducted in the fraction <63 μm. The highest levels of pollutants were found in sediments from the Gulf of Gdańsk and the Gdańsk Deep. In these sediments, concentrations of pp'-DDT and its metabolites (pp'-DDE and pp'-DDD) ranged from 2 to 11 μg kg(-1) dw. Concentrations of HCB were between 0.1 and 1.0 μg kg(-1) dw. Concentrations of the sum of α-, β-, γ-HCH were between 0.3 and 2.58 μg kg(-1) dw. Concentrations of marker PCBs ranged from about 2 to 11 μg kg(-1) dry weight. Total TEQ PCDD/F/dl-PCB values in the studied samples varied between 1 and 18 ng kg(-1) dw. The data were evaluated in terms of ecotoxicological criteria based on the environmental impact of the pollutant effects. Our research indicated that in the sediment from the southern Baltic Sea, the PCDD/F and PCBs occurred at concentrations which could be dangerous to marine organisms.  相似文献   

16.
Concentrations of organochlorine pesticides (OCPs; dichlorodiphenyltrichloroethanes (DDTs), hexachlorocyclohexanes (HCHs), hexachlorobenzene (HCB)) were investigated in 105 soil samples collected in vicinity of the chemical industrial parks in Tianjin, China. OCP concentrations significantly varied in the study area, high HCH and DDT levels were found close to the chemical industrial parks. The intensity of agricultural activity and distance from the potential OCP emitters have important influences on the OCP residue distributions. Principal component analysis indicates that HCH pollution is a mix of historical technical HCH and current lindane pollution and DDT pollution input is only due to technical DDT sources. The significant correlations of OCP compounds reveal that HCHs, DDTs and HCB could have some similar sources of origin.  相似文献   

17.
Carbon monoxide concentrations were measured in six shops situated in narrow busy streets of the city centre for ten days in winter and ten days in summer and correlated with the measurements simultaneaously performed at an outdoor background reference point. The correlation was significant for four out of six shops in winter, but not in summer. Day-to-day variations seemed to be influenced by gross contamination due to changing weather conditions whereas differences in concentration levels from site to site were strongly influenced by the proximity and density of traffic. The exposure of a pedestrian in winter was in good correlation with background outdoor levels and it was considerably lower than that of a car driver driving though the city.  相似文献   

18.
The study was conducted between January and December 2002. The main objective of this study was evaluation of effects of refrigerated storage duration on redistribution of three trace elements (Cd, Cu and Zn) in tissues (exoskeleton, abdominal muscle and hepatopancreas) of a shrimp species (Penaeus semisulcatus). Moreover, the possible roles of metallothionein (a kind of metalloprotein) in redistribution of the elements in tissues of the selected species were assessed. The specimens were sampled from northwestern part of the Persian Gulf. The concentrations of metals in the tissues were measured using Inductively Coupled Plasma-Optical Emission Spectrophotometer (ICP-OES). Metallothionein levels were determined by Differential Pulse Polarography (DPP) method. pH of the muscle samples was also measured in different stages. Different statistical methods were used for interpretation of the results. There were no size-dependent differences in metal contents of the species. The results were compared with specimens from other areas of the world and existing guidelines and limits. Concentrations of the metals in the muscle (0.103, 3.418 and 8.977 µg g–1 wet weight in the case of Cd, Cu and Zn, respectively) samples were below the most guidelines for human consumption. The results were in general agreement with those obtained by some other researchers. There were highly significant differences between sexes in Zn and Cu contents. Levels of Zn in females were significantly higher than males. The reverse case observed for Cu. The highest mean Cu and Zn concentrations (15.939 and 43.394 µg g–1 wet weight, respectively) were found in hepatopancreas samples, but the highest level of Cd (0.790 µg g–1 wet weight) was observed in exoskeleton. There were significant differences between the fresh and refrigerated samples from accumulation of Cd and Zn in tissues point of view, which can be attributed to the metal binding properties of metallothioneins as well as their degradation during the storage.  相似文献   

19.
The aim of this study is to examine the relative contribution of the outdoor concentration, the ventilation rate, the geometric characteristics of the indoor environment (i.e., extent of indoor surfaces and indoor volume), the deposition, and chemical reactions to the indoor air quality of the office microenvironment. For this case study, the NO, NO2, and O3 concentrations indoors and outdoors and TVOCs and CO2 concentrations indoors were measured in an office microenvironment in Athens, Greece, that was ventilated both naturally and mechanically. The calculated ventilation and loss rates and the measured outdoor concentrations of NO, NO2, and O3 were set as input to Multi-chamber Indoor Air Quality Model in order to study the temporal variation of the indoor NO, NO2, and O3 concentrations. Results showed that when the ventilation rate and outdoor concentration are high, the relative contribution of the transport process contributes significantly, while the chemical process depends on the contemporary interplay between the indoor O3, NO, and NO2 concentrations and lighting levels. The significance of each process was further examined by performing sensitivity tests, and it was found that the most important parameters were the deposition velocities, the UV infiltration rates (which determines the indoor chemical reaction rates), the ventilation rates, and the filtration (when a mechanical ventilation system is used). The effect of the hydrocarbon chemistry was not significant.  相似文献   

20.
Determinations of PCB were carried out as part of a project aimed at developing cleanup methods for PCB-containing elastic sealant used in outdoor joints between concrete blocks. The goals of the project were to develop methods, which minimise the spread of PCB to the outdoor environment and to indoor air, and which keep the PCB levels as low as reasonably possible in the workplace environment whilst removing the elastic sealant. The following PCB determinations were carried out: (1) concentration in the elastic sealant; (2) concentration in the concrete close to the sealant; (3) concentration in soil; (4) concentration in the indoor air; and (5) concentration in the air in the workplace environment. The cleanup process consisted of a number of different steps: (1) cutting the elastic sealant with an oscillating knife; (2) grinding the concrete with a mechanical machine; (3) sawing the concrete with a mechanical saw and (4) cutting the concrete with a mechanical chisel. In all these different steps a high capacity vacuum cleaner connected to the machines was used. The elastic sealant contained 4.7 to 8.1% total PCB of a technical product with a composition most similar to Clophene A40. The concrete close to the sealant (first 2 mm) contained 0.12 and 1.7% total PCB at two different places. The pattern of the PCB in the concrete resembled that of the sealant. PCB concentrations in the soil from the ground close to the building were 0.1 and 0.3 ppm at two different places before the remedial action. The source of the PCB in the soil is most likely the sealant as the PCB pattern is similar for the two materials. The PCB levels in the workplace air at the beginning of the project, when the techniques were not fully developed, were generally above the occupational exposure limit of 10 micrograms m-3 (up to 120 micrograms m-3). Later when the techniques were optimised to better take care of dust and gases produced during the cutting and grinding etc., the levels were below or close to 10 micrograms m-3. The pattern of the PCB in the workplace air was different from that of the sealant and contained higher levels of lighter components. The PCB concentrations in the indoor air were measured before and during the remedial process. The levels were around 600 ng m-3 and there was no significant increase during the removal of the sealant. The PCB level after the remedial action will be measured later. The pattern of the PCB in the indoor air was different from that of the sealant as well as from that of the workplace air. Higher levels of the lighter PCB were present indoors compared to the composition in both workplace air and in sealant. Extracts of PCB were analysed by GC-MS with a SIM method (selected ion monitoring). Standard procedures were used for extraction of solid materials. For the air samples an OVS tube was used with XAD-2 as adsorbent. The filter and adsorbent were extracted with toluene. This work shows that it is important to perform remedial action of PCB-containing elastic sealant as: (1) there is a spread of PCB to the indoor air giving high enough concentrations to make this the main PCB load on humans living in the apartments studied in this project; (2) large amounts are spread to the soil from these sealants; and (3) many of the PCB-containing elastic sealants used need to be changed from a functional perspective.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号