首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Regeneration studies of wastewater effluent from an organized industrial district (OID) for possible reuse in textile industry as process water was investigated. Advanced treatment methods including Fenton process, polyaluminium chloride (PAC) coagulation and ion exchange were applied on OID effluent. In Fenton process removal efficiencies for suspended solids (SS), chemical oxygen demand (COD), SAC436 (spectral absorption coefficient), SAC525 and SAC620 were determined 61%, 36%, 35%, 49% and 67%, respectively. After Fenton process, wastewater samples were coagulated with PAC. Optimum removal efficiencies for SS, COD, Fe ion, SAC436, SAC525 and SAC620 were determined 83%, 18%, 93%, 32%, 36% and 58%, respectively. Ion exchange experiments were conducted on chemically coagulated wastewater samples to improve the quality of wastewater. Optimum dosage of resins was determined. The experiments revealed that 1:1 resin ratio (20 mL H-type resin:20 mL OH-type resin) gave the best removal rates for the parameters considered in this study. Study results indicated that quality of the wastewater was suitable for the process water characteristics of textile industry and unit wastewater treatment cost was determined as 2.54 €/m3.  相似文献   

2.
Irradiation with ultrasound (US) and use of an enzyme (E) as pretreatment techniques were carried out to treat a complex effluent (distillery wastewater). These two techniques have been used alone as well as in combination and the efficacy of these techniques was tested by subjecting the effluent to subsequent aerobic biological oxidation (AO). When used alone, US exposure for 30 min and 2 h yielded the best COD reduction during the aerobic oxidation step (US+AO). For the enzyme when used alone, a pH value of 4.8 (corresponding to the optimum pH of the enzyme), a dose of 50 U and a pretreatment time of 24 h yielded better COD removal efficiency as compared to untreated effluent (aerobic oxidation alone). When used in combination, ultrasound followed by enzymatic pretreatment (US+E+AO) yielded the best COD removal efficiencies during aerobic oxidation as compared to the other combinations tested for the treatment of the distillery wastewater. A 4-fold increase in the initial oxidation rate was observed over the untreated batch for the integrated technique (US+E+AO). On the basis of the variation in the values of the biokinetic parameters it can be concluded that the type of pretreatment scheme affects the subsequent rate of the aerobic oxidation significantly.  相似文献   

3.
The treatment and reuse of domestic wastewater using an anaerobic baffled reactor (ABR) followed by a duckweed pond (DWP) were the main theme of the present study. The ABR was fed continuously with domestic wastewater at four HRTs ranging from 8 to 24 h and corresponds to organic loading rates ranging from 0.67 to 2.1 kg COD/m3/day. The ABR effluent was fed to a DWP operating at 10 and 15 days. The performance of the ABR at the four HRTs gave satisfactory results. Chemical oxygen demand (COD) removal was between 68 and 82%. Fecal coliform removal was between 1 to 2 logs. The 12- and 18-h hydraulic retention times (HRTs) gave close results, as indication of the possible selection of the 12-h HRT as the optimum operation for the ABR based on economic advantage. The ABR compartmentalized structure gave results higher than those produced by the one-stage digester and similar to those produced by the two-phase anaerobic digestion process. Duckweed ponds as post-treatment operated at 10 days and 15 days gave the best results at 15-day HRT, where it was possible to remove 73.4% of nitrogen and 65% of phosphorus and produce protein-rich dry duckweed of 105 kg/ha/day on average. The removal of fecal coliform (FC) in duckweed ponds was 3–4 logs. The final treated domestic sewage characteristics proved its compliance with the Egyptian standards for reuse in restricted irrigation.  相似文献   

4.
This study focuses on a lab-scale rotating biological contactor (RBC) treating vegetable oil wastewater with high BOD and COD. The fabricated RBC was checked for efficiency in degrading polluted wastewater under different operating conditions. The maximum removal efficiencies for BOD and COD were 95.75% and 89%, respectively. This high removal percentage was obtained with 30% submergence of 10 discs rotating at 8 rpm. For the first time, bio-kinetic models were applied to the experimental results for vegetable oil wastewater. The best fit was obtained with the modified Stover-Kincannon and Grau model. The saturation constant (Ks) values were 1.872 and 3.024 g/L/d for BOD and COD, respectively, for the modified Stover-Kincannon and Grau model. For the Grau second-order model, the saturation constant was 1.416 and 3.744 g/L/d for BOD and COD, respectively. The predicted effluent BOD and COD values of the modified Stover–Kincannon model fitted almost exactly with the experimental values. This clearly predicts that this model can be best used to predict effluent BOD and COD concentration in a Rotating Biological contactor treating vegetable oil wastewater. The kinetic parameters determined in this study can be used to improve the design and operation of continuous mode RBC systems.  相似文献   

5.
Combined chemical and biological oxidation of penicillin formulation effluent   总被引:12,自引:0,他引:12  
Antibiotic formulation effluent is well known for its important contribution to environmental pollution due to its fluctuating and recalcitrant nature. In the present study, the chemical treatability of penicillin formulation effluent (average filtered COD(o)=830 mg/l; average soluble COD(o)=615 mg/l; pH(o)=6.9) bearing the active substances penicillin Amoxicillin Trihydrate (C(16)H(19)N(3)O(5)S.3H(2)O) and the beta-lactamase inhibitor Potassium Clavulanate (C(8)H(8)KNO(5)) has been investigated. For this purpose, the penicillin formulation effluent was subjected to ozonation (applied ozone dose=2500 mg/(lxh)) at varying pH (2.5-12.0) and O(3)+H(2)O(2) (perozonation) at different initial H(2)O(2) concentrations (=2-40 mM) and pH 10.5. According to the experimental results, the overall Chemical Oxygen Demand (COD) removal efficiency varied between 10 and 56% for ozonation and 30% (no H(2)O(2)) and 83% (20 mM H(2)O(2)) for the O(3)+H(2)O(2) process. The addition of H(2)O(2) improved the COD removal rates considerably even at the lowest studied H(2)O(2) concentration. An optimum H(2)O(2) concentration of 20 mM existed at which the highest COD removal efficiency and abatement kinetics were obtained. The ozone absorption rate ranged between 53% (ozonation) and 68% (perozonation). An ozone input of 800 mg/l in 20 min was sufficient to achieve the highest BOD(5)/COD (biodegradability) ratio (=0.45) and BOD(5) value (109 mg/l) for the pre-treated penicillin formulation effluent. After the establishment of optimum ozonation and perozonation conditions, mixtures of synthetic domestic wastewater+raw, ozonated and perozonated penicillin formulation effluent were subjected to biological activated sludge treatment at a food-to-microorganisms (F/M) ratio of 0.23 mg COD/(mg MLSSxd), using a consortium of acclimated microorganisms. COD removal efficiencies of the activated sludge process were 71, 81 and 72% for pharmaceutical wastewater containing synthetic domestic wastewater mixed with either raw, ozonated or perozonated formulation effluent, respectively. The ultimate COD value obtained after 24-h biotreatment of the synthetic domestic wastewater+pre-ozonated formulation effluent mixture was around 100 mg/l instead of 180 mg/l which was the final COD obtained for the wastewater mixture containing raw formulation effluent, indicating that pre-ozonation at least partially removed the non-biodegradable COD fraction of the formulation effluent.  相似文献   

6.
To reduce the consumption of freshwater in the laundry industry, a new trend of closing the water cycle has resulted in the reuse/recycling of water. In this study, the performance of a full-scale submerged aerobic membrane bioreactor (9 m3) used to treat/reuse industrial laundry wastewater was examined over a period of 288 days. The turbidity and total solids (TS) were reduced by 99%, and the chemical oxygen demand (COD) effluent removal efficiencies were between 70% and 99%. The levels of COD removed by the membrane were significantly greater than the levels of biodegraded COD. This enabled the bioreactor to sustain COD levels that were below 100 mg/L, even during periods of low wastewater biodegradation due to bioreactor sludge. An economic evaluation of the membrane bioreactor (MBR) system showed a savings of 1.13 € per 1 m3 of water. The payback period for this system is approximately 6 years. The energy and maintenance costs represent only 5% of the total cost of the MBR system.  相似文献   

7.
A combination of bacterial pretreatment followed by free water surface flow through wetland plants was investigated to determine its effect on removal of heavy metals in bioremediation of post-methanated distillery effluent (PMDE). The bacterial pretreatment was intended to transform the metal complexes and organic pollutants into simpler, biologically assimilable molecules. The 10% and 30% v/v concentrations of PMDE favored luxuriant bacterial growth; the 50% concentration supported less growth, whereas the undiluted effluent (i.e., 100%) supported very little bacterial growth. The use of bacterial pretreatment combined with the constructed wetland system greatly increase the overall bioaccumulation of all heavy metals by the plants compared with the control treatment. However, the integration of bacterial pretreatment of PMDE with the Typha angustata resulted in enhanced removal of Cd (34.02–61.50% increase), Cr (35.90–57.60% increase), Cu (32.88–54.22% increase), Fe (32.50–51.26% increase), Mn (35.99–82.85% increase), Ni (35.85–59.24% increase), Pb (33.45–59.51% increase) and Zn (31.95–53.70% increase) compared with a control that lacked this pretreatment. In addition to the bioaccumulation of these heavy metals, several physico-chemical parameters also improved at the 30% effluent concentration: color, BOD, COD, phenol and total nitrogen decreased by 98.33%, 98.89%, 98.50%, 93.75% and 82.39%, respectively, after 7 days of free water surface flow treatment. The results suggest that bacterial pretreatment of PMDE, integrated with phytoremediation will improve the treatment process of PMDE and promote safer disposal of this waste.  相似文献   

8.
The main objective of this paper was to perform a preliminary comparative study between chemical and electrochemical coagulation processes, both followed by flocculation and sedimentation of an effluent from an upflow anaerobic sludge blanket (UASB) reactor treating simulated wastewater from an unbleached Kraft pulp mill. The electrochemical treatment removed up to 67% (with aluminum electrodes) and 82% (with stainless-steel electrodes) of the remaining chemical oxygen demand (COD) and 84% (stainless steel) and 98% (aluminum) of the color in the wastewater. These efficiencies were achieved with an energy consumption ranging from 14 to 20 Wh l(-1). The coagulation-flocculation treatment with ferric chloride and aluminum sulfate removed up to 87% and 90% of COD and 94% and 98% of color, respectively. The addition of a high molecular weight cationic polymer enhanced both COD and color removal efficiencies. The two post-treatment processes proved to be technically feasible; however the economical feasibility could not be assessed since the experiments were performed with small reactors that could distort scale factors.  相似文献   

9.
Wood processing effluents contain different types of phenolic compounds, from simple monomers to high molecular weight (MW) polyphenolic polymers, that can inhibit wastewater treatment. This work presents a comparative study of the methanogenic toxicity produced by three wood processing effluents (hardboard, fiberboard and BKME (kraft mill effluent)) using Pinus radiata, Eucalyptus and Tepa as feedstock (the last one being a native Chilean tree species). This study evaluates the influence of non-adapted granular and adapted flocculent sludge on forest industrial wastewater treatment as well as continuous anaerobic biodegradation of hardboard processing effluent using the upflow anaerobic sludge blanket (UASB). The adapted biomass (flocculent sludge) did not show any lag-phase signs. The 50% IC (the concentration causing 50% inhibition of methanogenic activity) was 4.3 g COD-effluent (chemical oxygen demand (COD)-of the effluent)/l and 2.8 g COD-effluent/l for the flocculent sludge and the granular sludge, respectively. The UASB system worked at low organic load rates (0.1-0.4 g COD/l d) with the COD removal ranging between 10 and 30%, and color removal did not occur under anaerobic conditions due to high MW. Indeed, the MW analysis indicates the presence of phenolic compounds over 25,000 Da in the anaerobic effluent.  相似文献   

10.
Anaerobic/aerobic treatment of meat processing wastewater   总被引:2,自引:0,他引:2  
The meat processing industry is believed to produce highly polluted wastewater. Analysis of such wastewater indicated that the waste was highly contaminated with organic compounds as indicated by COD (1544mgO2l–1), BOD (646mgO2l–1), and TSS (1155 mgl–1). Moreover, oil and grease concentrations reached 144mgl–1 treatment of raw wastewater using Upflow Anaerobic Sludge Blanket (UASB) followed by Rotating Biological Contactors (RBC) was studied. Efficiency of the UASB for the removal of CODtotal, BODtotal, TSS, and oil and grease was 56%, 56%, 85%, and 58%, respectively. The quality of the UASB effluent barely complies with the regulatory standards for discharging wastewater into the sewerage network. UASB effluent was subjected for further treatment using a RBC unit to improve the quality of the treated effluent for reuse in irrigation purposes. Residual COD, BOD, TSS, and oil and grease, following RBC, was 132mgO2l–1, 40mgO2l–1, 44mgl–1, and 10mgl–1 respectively. The overall efficiency of the treatment units provided good quality effluent. The overall percentage removal of COD, BOD, TSS, and oil and grease was 91.5%, 94%, 96%, and 91%, respectively. Based on the quality of the treated effluent and guidelines recommended for wastewater reuse, it may be concluded that a slight to moderate restricted irrigation is applicable to reuse the treated effluent in the green belt around the factory. Disinfection should be applied to ensure the safety of such a process.  相似文献   

11.
Since the performance of algal treatment for pulp mill effluent decreases with increasing color intensity and AOX content, which mainly originate from the chlorine bleaching of Kraft pulp, the separated CEH bleaching effluent was pre-treated by both the conventional and the heterogeneous catalytic ozonation processes. An increase in the BOD(5)/COD ratio from 0.11 to 0.28 and 87% color abatement in terms of Pt-Co were achieved by catalytic ozonation, which had the best treatment performance. Biodegradability enhancement of the CEH effluent correlated well with a decrease in toxicity, high-molecular-weight-compound content, and AOX abatement. By the pre-treatment of the CEH bleaching effluent, the overall efficiencies of algal treatment of the combined pulp mill effluent in terms of the fractional removal of COD and color were increased from 76% and 53% to 86-90% and 96-99%, respectively. Effects of both the conventional and the catalytic ozonation pre-treatments on subsequent biological treatment were close to each other and they reduced the filling period of the Sequential Batch Reactor (SBR) cycle from 8 to 5 days.  相似文献   

12.
With the increase of urbanization, municipal solid waste has also increased. Therefore, the need for solid waste management is also increasing compared with earlier decades. Composting is a good option for the recycling of solid waste; however, it produces leachate, which requires proper treatment systems to prevent environmental degradation. Due to high chemical oxygen demand (COD) concentrations in compost leachate, anaerobic treatment is the best option for handling the effluent, and an anaerobic baffled reactor (ABR) is one such anaerobic reactor that can be used for its treatment. Because of high ammonia and heavy metal concentrations, as well as the possibility of sludge washout in ABRs, it is important to use proper media, such as zeolite, which can reduce inhibition effects and sludge washout from the reactor. Anaerobic treatment, especially during the methanogenesis phase, is sensitive, and pH and alkalinity are parameters that influence the treatment. Therefore, adjusting these parameters within a normal range is very important to the proper functioning of anaerobic systems. In this study, a pilot‐scale ABR was used, and the last 4 of the 8 ABR compartments were filled with zeolite. The bioreactor was operated at hydraulic retention times (HRT) of 3, 4, and 5 days, with zeolite filling ratios of 10%, 20%, and 30%, and influent COD concentrations of 10,000, 20,000, and 30,000 milligrams per liter (mg/L). In this study, pH value was 6.43 ± 0.1, 6.96 ± 0.3, and 6.96 ± 0.25 at filling ratios of 10%, 20%, and 30%, respectively. According to the results, in all filling ratios, no significant changes were observed in the pH value when the organic loading rate increased and its amount was within a constant range. Influent alkalinity was equal to 2015 ± 510, 2884 ± 505, and 4154 ± 233 milligrams of calcium carbonate per liter (mg CaCO3/L) at influent COD concentrations of 10,000, 20,000, and 30,000 mg/L, respectively, and in effluent, they were 2536 ± 336, 3379 ± 639, and 4377 ± 325 mg CaCO3/L, respectively. The amount of alkalinity in the effluent increased compared with the alkalinity in the influent. The results show that the amount of alkalinity in the influent and effluent was similar, and the alkalinity enhancement was lower when the filling ratio was increased from 10% to 20%, and 20% to 30%. Comparisons of the results from zeolite with and without biofilm showed that, in cases of zeolite with biofilm, the amounts of silica and oxygen decreased and the amount of carbon increased, and it showed the formation of biofilm on the surface of zeolite. In addition, the absence of sodium in the zeolite with the biofilm indicated that sodium was exchanged with ammonium ions. According to the results, zeolite can be used in anaerobic reactors as a medium, and it also reduces fluctuations in pH and alkalinity at different organic loading rates, providing a normal range for anaerobic treatment.  相似文献   

13.
Molasses-based distilleries are one of the most polluting industries generating large volumes of high strength wastewater. Different processes covering anaerobic, aerobic as well as physico-chemical methods have been employed to treat this effluent. Anaerobic treatment is the most attractive primary treatment due to over 80% BOD removal combined with energy recovery in the form of biogas. Further treatment to reduce residual organic load and color includes various: (i) biological methods employing different fungi, bacteria and algae, and (ii) physico-chemical methods such as adsorption, coagulation/precipitation, oxidation and membrane filtration. This work presents a review of the existing status and advances in biological and physico-chemical methods applied to the treatment of molasses-based distillery wastewater. Both laboratory and pilot/industrial studies have been considered. Furthermore, limitations in the existing processes have been summarized and potential areas for further investigations have been discussed.  相似文献   

14.
采用将脱硫废液与炼油废水按比例混合之后对其进行处理的方法,通过批式试验,考查混合废液的BOD5/COD指标及其COD、NH3-N、S2-的去除率。筛选合适的混合液配比,分别对500︰1和800︰1的混合废液进行了模型试验,分析了COD去除效果。结果表明:800︰1的混合废液在10d之后,出水COD为134mg/L,达到了《污水综合排放标准》(GB8978—1996)二级标准要求。最终确定炼油废水与脱硫废液混合的合适比例应不低于800︰1。  相似文献   

15.
This experimental study was conducted to evaluate a membrane sequencing batch reactor (MSBR) with mixed culture photosynthetic bacteria for dairy wastewater treatment. The study was undertaken in two steps: laboratory and pilot scale experiments. In the first step, kinetics analysis of the MSBR was carried out in a laboratory scale experiment with influent COD concentration of 2500 mg/L. The pilot scale experiment was conducted to investigate the performance of the MSBR and checked the suitability of the kinetics for an engineering design. The kinetic coefficients Ks, k, kd, Y and μm were found to be 174-mg-COD/L, 7.42/d, 0.1383/d, 0.2281/d and 1.69/d, respectively. There were some deviations of COD removal efficiency between the design value and the actual value. From the kinetics estimation, COD effluent from the design was 27 mg/L while the average actual COD effluent from the experiment was 149 mg/L. Due to the different light source condition, the factors relating to light energy (i.e. Lf and IR%) must be incorporated into engineering design and performance prediction with these kinetic coefficients of the photosynthetic MSBR.  相似文献   

16.
Industrialization plays a major role in a nation's growth. However, with an increase in industrial activities, pollution levels are also increasing. Among all industries, the sugar‐processing industry is one that requires large amounts of water to process the sugar, and, consequently, it discharges large amounts of water as effluent. Highly polluted wastewater brings changes to the physicochemical characteristics of the surrounding environment. Iron compounds have had a significant impact when they are used in wastewater treatment in various applications, including when they are used to minimize the pollution levels in sugar industry wastewater (SIWW). To minimize the pollutant levels from SIWW, iron compounds have been key for uses in treatments involving chemical and electro‐oxidation. Two different methodologies of electrocoagulation and chemical coagulation have been used to treat SIWW. In electrocoagulation, an iron plate is used as an electrode material under specific operating conditions. Ferrous sulfate and ferric chloride have been used as chemical coagulants at various pH and mass loading levels. The use of iron metals shows an 82% reduction in chemical oxygen demand (COD) and an 84% reduction in color at the optimum condition of pH 6, an electrode distance of 20 millimeters, and a current density of 156 square centimeters. As a chemical coagulant, iron salt (ferrous sulfate) provides a reduction of 77% COD and a 91% reduction of color at pH 6 and a 40‐millimole mass loading. Electrochemical treatment using iron was found to be suitable to treat SIWW. The sludge generated after treatment can be burned or composted with the possible recovery of some of the treatment costs.  相似文献   

17.
以奇台太极华力食品有限公司番茄废水处理工程实例为依据,介绍了采用ABR厌氧+完全混合活性污泥法工艺在处理番茄加工废水的设计、调试及运行情况。经过2年运行,其进水COD在700~1 500mg/L之间,最大处理水量达到4 000m3/d;出水COD在40~70mg/L之间,COD去除率达到97%。处理出水可以稳定达到污水综合排放二级标准。ABR+完全混合活性污泥法工艺具有启动快,调试时间短,工程造价低的优点,尤其适宜处理番茄等间歇时间长工作时间短的季节性生产污水。  相似文献   

18.
A conventional activated sludge treatment facility was the subject of this study. The assessment was directed at determining the characteristics of the raw wastewater, the quality of the treated effluent and the efficiency of the various treatment units. Furthermore, the water quality along the effluent irrigation canal was monitored. The assessment of the quality of the treated effluent for irrigation is based on the guidelines established by the World Health Organization and the Egyptian decree 9/89 for the use of wastewater in agriculture. The results of the study indicated that the concentration of the raw wastewater was considered moderate. The mean values of the COD (Chemical Oxygen Demand), BOD (Biological Oxygen Demand) and total suspended solids (TSS) were around 250, 102 and 142 mg l–1, respectively. This was attributed to the high quantities of wastewater from industrial sources. The overall efficiency of the treatment facility was good. The mean residual COD, BOD and TSS were 25, 8 and 21 mg l–1 and the corresponding percentage removal values were 90, 92 and 85%, respectively. The maximum percentage removal of oil and grease was 84% with a mean residual concentration of 24 mg l–1. The total viable count (22°C and 37°C), faecal coliform and aecal streptococci were reduced by 99.9% compared to only 99.5% for Salmonella. Bacteriological examination of the dried sludge indicated a reduction of nine logs of faecal coliform and faecal streptococci, as compared to thickened sludge. Analysis of the Ni, Cu, Pb and Cr in the dried sludge indicated that their concentrations are within the permissible limits. Zinc exceeded the consent standards by 50%. The results of the analyses of samples collected at the beginning of the irrigation canal indicated insignificant changes from the characteristics of the final effluent. Samples collected at a distance of 2km along the irrigation canal showed mean reductions in the COD and BOD of 28.6 and 47%, respectively, which could be attributed to sedimentation and/or a self-purification effect. An increase in the total nitrogen, total phosphorus and total viable count was also recorded, which could be due to seepage from the agricultural land. From the data available it is evident that the treated wastewater could be used for restricted irrigation. The design and implementation of a monitoring programme is recommended.  相似文献   

19.
Overland flow (OF) systems were evaluated and compared for advanced treatment of municipal and industrial effluents, including nutrients and nondegradable chemical oxygen demand (COD) removal. Three pilot plants were constructed at the Shahin Shahr Wastewater Treatment Plant (WWTP), Isfahan, Iran. Each pilot was assigned a specific wastewater and all were simultaneously operated for 8 months. Treatment of primary effluent, activated sludge secondary effluent, and lagoon effluent of textile wastewater was investigated at application rates (ARs) of 0.15, 0.25, and 0.35m(3)m(-1)h(-1). During 5 months of stable operation after a 3-month acclimation period, mean removals of total 5-day biochemical oxygen demand (TBOD(5)), total COD (TCOD), total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and turbidity were 74.5%, 54.8%, 66.2%, 39.4%, 35.8%, and 67.7% for primary effluent; 52.9%, 52.9%, 66.5%, 44.4%, 39.8%, and 50.1% for activated sludge effluent; 65.7%, 58.7%, 70.3%, 41.7%, 41.3%, and 54.9% for textile wastewater lagoon effluent, respectively. The model of Smith and Schroeder, 1985. Field studies of the overland flow process for the treatment of raw and primary treated municipal wastewater. Journal of Water Pollution Control Federation 57, 785-794] was satisfactory for TBOD(5). For all treatment parameters a standard first-order removal model was inadequate to represent the data but a modified first-order model provided a satisfactory fit to the data. Based on the results of this study, it can be concluded that an OF system as advanced treatment had the ability to meet effluent discharge permit limits and was an economical replacement for stabilization ponds and mechanical treatment options.  相似文献   

20.
The aim of this work was to examine the performance of a sand filter in treating modern olive mill (OMW) effluents after dilution with domestic wastewater on a one-to-one basis. The experimental pilot consisted of a column of opaque PVC, and the sand filter was filled with 50 cm of sand and 10 cm of gravel in the top and the bottom of the filter. The alimentation (4 cm/day) was done sequentially following a 1 day wet/3 days dry cycle. The OMW effluent was very acidic with a pH of 4.12, and had high concentrations of phenolic compounds (7.2 g/L) and total chemical oxygen demand (65 g/L). The percolation of the diluted OMW through the sand filters caused an increase in pH from 4.84 to 8.25 and a 90% removal of total suspended solids. The sand filter treatment also led to important reductions in organic matter (90% of total COD, 83% of dissolved COD and 92% of phenolic compounds) and nutrients (91% of Kjeldahl-nitrogen, 97% of ammonia-nitrogen, 99% of nitrate-nitrogen and 99% of phosphates). The flow rate became very low indicating clogging of the sand pores after 10 weeks. HPLC analysis of the diluted OMW before and after passage through the sand filter showed an important reduction in the toxic monomeric compounds after the treatment.  相似文献   