共查询到19条相似文献,搜索用时 72 毫秒
1.
2.
MUCT-MBR工艺反硝化除磷脱氮研究 总被引:3,自引:2,他引:1
自行设计的双反应器MUCT-MBR简化了MUCT工艺,将反应池由5个简化到2个,减小了工艺占地面积,并且采用膜过滤取代二沉池出水,操作简单,出水安全可靠.针对MUCT-MBR工艺脱氮除磷性能,尤其是反硝化除磷功能进行研究.结果表明,当进水C/N/P比在33.3/5/1~25/5.5/1范围内,整个实验过程中COD、 TN和TP平均去除率分别达到89.3%、 75.4%、 79.2%;且膜出水不受污泥沉降性的影响.缺氧段的反硝化吸磷是MUCT-MBR工艺除磷的关键,系统运行至第58 d,系统中反硝化除磷菌(DPAOs)所占比例达84.2%,反硝化除磷占系统总磷去除的67.07%. 相似文献
3.
温度对生物强化除磷工艺反硝化除磷效果的影响 总被引:7,自引:1,他引:7
以处理城市污水的中试规模生物强化除磷A2/O活性污泥工艺系统为研究对象,考察了温度对系统COD去除和脱氮除磷效果的影响,特别是温度对活性污泥反硝化除磷性能的影响.结果表明,当温度从(30.9±0.8)℃降低到(9.1±0.6)℃时,A2/O系统的脱氮除磷效果显著下降,系统对TN和TP的污泥去除负荷明显下降.通过污泥反硝化除磷活性实验发现,随着温度的降低,系统中活性污泥的最大厌氧释磷速率、最大好氧吸磷速率和最大缺氧吸磷速率都降低.活性污泥中反硝化除磷菌(DPB)占聚磷菌(PAOs)总量的比例随温度降低稍有下降,但平均值仍维持在47.5%左右.用阿伦尼乌斯公式对实验结果进行拟合,得到系统中活性污泥聚磷菌厌氧释磷反应活化能Ea1为148.0 kJ· mol-1,聚磷菌好氧吸磷反应活化能Ea2为228.8 kJ·mol-1,发生在缺氧条件下反硝化除磷菌的吸磷反应活化能Ea3为315.8 kJ·mol-1.对不同温度下污泥絮体粒径分析结果表明,随温度降低,粒径分布更加集中,系统中活性污泥絮体颗粒平均粒径减小,不利于污泥絮体内部反硝化除磷缺氧微环境的形成. 相似文献
4.
5.
为探究自行设计的A~3/O-MBR工艺脱氮除磷性能,以模拟生活污水为处理对象,重点研究了在内循环回流比(γ)为100%,硝化液回流比(α)分别为100%、200%、300%条件下系统反硝化除磷特性。结果表明:缺氧II区是工艺反硝化除磷的关键,系统具有优良的同步脱氮除磷效果,ρ(COD)出水均低于50 mg/L。当回流比为200%时,系统对TN、TP去除效果最好,平均去除率分别为75.46%和88.94%,出水平均ρ(TN)、ρ(TP)分别为14.97 mg/L和0.48 mg/L。通过静态释/吸磷试验测定不同硝化液回流比条件下反硝化聚磷菌占总聚磷菌的比例及污泥含磷量,当回流比为200%时,反硝化聚磷菌所占比例最高达95.47%,该回流比条件下缺氧II区污泥含磷量最高为23.07 mg/L,最大吸磷量为0.2136 g/d。 相似文献
6.
以低C/N城市生活污水为处理对象,重点考察了硝化液回流比对A2/O - BCO(生物接触氧化)工艺脱氮除磷特性的影响.在A2/O反应池水力停留时间(HRT)为8h,污泥回流比为100% 条件下,将硝化液回流比分别设定为100%、200%、300%和400%进行试验.结果表明, 系统在A2/O中实现了反硝化除磷,具有很好的同步氮磷的去除效果,出水COD浓度均在50mg/L以下.上述不同硝化液回流比下总氮(TN)去除率分别为48.8%、66.5%、75.6%和62.5%,总磷(TP)去除率分别为86.0%、90.3%、91.0%和95.0%.在硝化液回流比为300%时,系统平均出水TN和TP浓度分别为14.96mg/L和0.49mg/L.系统反硝化除磷量随着硝化液回流比的增大略有增加,在硝化液回流比为400%时,反硝化除磷量高达磷总去除量的98%. 相似文献
7.
8.
采用反硝化除磷工艺进行生产性试验处理城市污水,结果表明:该工艺处理城市污水可以达到GB18918-2002一级标准,DPB污泥沉降性能良好,污泥浓度控制在4500~5500mg/L时确定的污泥回流比为20~35%,最佳水力停留时间为:厌氧段0.5~1h,缺氧段1.5~2h;缺氧段后面的再曝气段有利于污泥沉降并可保证除磷效果. 相似文献
9.
采用反硝化除磷工艺进行生产性试验处理城市污水,结果表明:该工艺处理城市污水可以达到GB18918--2002一级标准,DPB污泥沉降性能良好,污泥浓度控制在4500-5500mg/L时确定的污泥回流比为20—35%,最佳水力停留时间为:厌氧段0.5~1h,缺氧段1.5~2h;缺氧段后面的再曝气段有利于污泥沉降并可保证除磷效果。 相似文献
10.
11.
为了提高系统的反硝化除磷脱氮效率,采用静态试验考察了厌氧反应时间和厌氧段COD对A2O-BAF工艺反硝化聚磷效果的影响,同时对缺氧阶段反硝化聚磷量与脱氮量之间的关系进行了探讨.试验结果发现,在试验范围内,随着厌氧反应时间和厌氧段COD的增加,厌氧释磷量均增加,反硝化聚磷量,净聚磷量和硝氮去除量亦都随之增加,但是反硝化聚磷量与释磷量的比值基本维持不变.在2组8个不同的试验条件下,缺氧段反硝化聚磷量和脱氮量之间均呈现出良好的线性关系,系数为1.007~1.053,R2为0.992~0.997,反映了A2O-BAF系统中污泥的固有特性. 相似文献
12.
Wang Yayi Wang Shuying Peng Yongzhen Zhu Guibing Ling Yunfang 《Frontiers of Environmental Science & Engineering in China》2007,1(2):226-232
To supply the valuable operating parameters for the popular usage of the new denitrifying phosphors removal process, it is
essential to study the dominant biochemical reactions and the characteristics of denitrifying phosphorus removing bacteria
(DPB). Thus, parallel batch experiments using DPB sludge were carried out to assess the effect of substrates (sewage, HAc,
and endogenous carbon source) on denitrifying dephosphorus removal efficiency in this study. The results showed that the initial
specific phosphorus release rate increased with the high concentration of the short-chain volatile fatty acids ratio in the
influent, and sufficient phosphorus was released by DPB. This improved the subsequent denitrification and phosphorus uptake
efficiency. The specific endogenous denitrification mainly relies on the internal carbon source (PHB) stored by poly-P bacteria.
Denitrifying phosphorus removing bacteria were very hungry when the internal PHB was consumed. Consequently, the specific
endogenous denitrification rate was low and the phosphorus uptake did not happen. On the other hand, in the experiment, the
denitrifying phosphorus removal performance under two temperature conditions (8–10°C and 25–26°C) was also investigated and
analyzed. It was found that the lower temperature decreased the specific phosphorus release and uptake rate, but did not inhibit
the denitrifying phosphorus removal completely. Therefore, the negative influence of the low temperature on the overall phosphorus
removal was not significant.
Translated from Acta Scientiae Circumstantiae, 2006, 26 (2): 186–192 [译自: 环境科学学报] 相似文献
13.
电子受体亚硝酸氮在反硝化除磷过程中的作用 总被引:5,自引:0,他引:5
针对先前文献提到的亚硝酸氮在反硝化除磷中存在着一定的抑制作用,以亚硝酸氮作为电子受体,对其在缺氧反硝化吸磷过程中的抑制影响进行了大量的静态烧杯试验.结果表明,在亚硝酸氮浓度大于30mg·L-1的时候,确实存在严重的抑制作用,而且该临界抑制浓度与污泥的特性和运行操作条件等因素有关;但是在亚硝酸氮浓度低于25mg·L-1的情况下不会对反硝化条件下磷的吸收产生毒害作用,相反地,它可以取代氧气、硝酸氮做为良好的电子受体用来进行缺氧段磷的生物摄取,在反硝化除磷中表现一定的积极作用. 相似文献
14.
SBR不同进水中反硝化除磷颗粒污泥的培养 总被引:1,自引:0,他引:1
分别以人工配水、加Ca~(2+)人工配水和实际生活污水为进水水源,在A/O/A运行模式的3套SBR反应器(R1、R2和R3)中培养反硝化除磷颗粒污泥,研究了其生化特性和启动过程的除污性能,分析了反硝化除磷能力,最后对颗粒化机理进行了探讨,重点考察了反硝化除磷颗粒污泥启动过程中对COD、NH_4~+-N、TN和TP的去除情况.结果表明,R1~R3均在30 d内成功得到反硝化除磷颗粒污泥,颗粒污泥平均粒径大于600μm,比重和比耗氧速率较大,含水率较低;培养过程中出水COD平均值低于40 mg·L~(-1),出水TN、NH+4-N及TP平均浓度低于1 mg·L~(-1);系统稳定后一个典型周期内试验表明,COD、NH_4~+-N、TN和TP的去除效果良好,对COD、NH+4-N、TN及TP的去除率可达90%以上;R1~R3中最大比释磷速率分别达14.34、8.32和2.32 mg·g·h~(-1)(以每g MLVSS每小时释放的P量(mg)计),R1~R2中最大比吸磷速率分别达14.13和2.34mg·g·h~(-1)(以每g MLVSS每小时吸收的P量(mg)计);试验结果表明,Ca~(2+)对颗粒化有促进作用. 相似文献
15.
16.
污泥龄对低氧丝状菌活性污泥微膨胀系统的影响 总被引:2,自引:0,他引:2
为了研究污泥龄(SRT)对低氧丝状菌活性污泥微膨胀系统的影响,采用序批式间歇反应器(SBR)进行试验,分别按照厌氧/好氧和单级好氧的方式运行,考察了不同SRT下丝状菌污泥微膨胀系统的沉降性、脱氮除磷过程以及污泥特性的变化.结果表明,在好氧水力停留时间充分的条件下,低氧环境不但不会影响丝状菌微膨胀污泥的硝化进程,而且还有助于同步硝化反硝化(SND)、单级好氧除磷的发生.厌氧/好氧运行时,SRT与活性污泥的比硝化速率、比释磷速率和比吸磷速率成反比,与SND率和污泥的含磷量成正比.单级好氧运行时,减小SRT对硝化过程影响不大,但是有助于改善除磷效果.活性污泥的比耗氧速率(SOUR)、胞外聚合物(EPS)中多糖与蛋白质含量的比值、以及粘度都与SRT成反比.适当地减小SRT可以改善丝状菌微膨胀污泥的沉降性.厌氧/好氧运行时,厌氧段微氧环境易引发过度丝状菌污泥膨胀;单级好氧运行时,SRT过低会造成污泥黏性骤增而引发黏性污泥膨胀. 相似文献
17.
在低温条件下,采用A2O-BAF工艺处理低碳氮比实际生活污水.结果表明,该双污泥工艺在平均温度为14.2℃、平均进水COD 369.5mg/L、TN 76.8mg/L即C/N为4.81的工况下可以实现深度脱氮除磷.平均出水TN与TP分别为13.21mg/L和0.23mg/L.其中COD、氨氮、TP和TN的去除率分别为86.2%、99.8%、96.6%、81.5%,达到国家污水处理一级A标准(GB18918-2002).低温下A2O工艺段活性污泥的平均SVI为85.4mL/g,污泥具有良好的沉降性能.此外试验过程中可以利用pH值和氧化还原电位值作为该系统A2O各反应阶段的控制参数,来间接的指示A2O各区的反应情况. 相似文献
18.
SBR双颗粒污泥系统脱氮除磷性能研究 总被引:2,自引:0,他引:2
以模拟废水为研究对象,对SBR双颗粒污泥系统的脱氮除磷性能进行了考察.试验结果表明,A2N双颗粒污泥系统能使硝化菌和聚磷菌分别在各自最佳的环境中生长,有利于系统脱氮除磷的稳定和高效运行,可控制性也得到了提高.在COD为300 mg·L-1条件下,系统对COD的平均去除率达到78.8%,大部分COD被聚磷菌用来合成PHA;当溶解氧控制在3.55~4.90 mg·L-1和5.60~6.60 mg·L-1之间时,硝化SBR对氨氮的去除率分别为87.0%和94.5%.除磷SBR仅设置缺氧段时,磷去除率为72%;增设后曝气段后,磷去除率增至85%.NOx--N(NO2--N+ NO3--N)的去除主要发生在缺氧段,在反硝化除磷时作为电子受体被去除,平均去除率为90.6%. 相似文献
19.