共查询到20条相似文献,搜索用时 0 毫秒
1.
Julene S. Carvalho 《黑龙江环境通报》2004,24(13):1060-1067
The detailed study of the fetal cardiac anatomy in the first trimester of pregnancy by means of ultrasound, transvaginally or transabdominally, is feasible and remains a safe procedure provided thermal and mechanical indices are taken into account. Optimal time for successful imaging of the four chambers and great arteries in early gestation appears to be between 13 to 14 weeks. In experienced hands, first-trimester fetal echocardiography is accurate in detecting major structural cardiac abnormalities and yields a high negative predictive value. Thus, in a clinical setting, it can be offered to families considered to be ‘at risk’ of cardiac defects (e.g. those with previous family history or when fetal nuchal translucency is increased) and can be a powerful tool to reassure families regarding normality of major cardiac structures and connections. However, the early detection of an important structural abnormality (chromosomally normal or not) may be associated with a high termination rate if this is an acceptable option. The high prevalence of associated chromosomal and extracardiac abnormalities for many of the high-risk families, who may benefit from this approach, cannot be ignored. Therefore, fetal heart scanning in the first trimester should be performed in conjunction with detailed first-trimester obstetric scanning. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献
2.
3.
Lee P. Shulman MD Nabil A. Raafat Phyllis C. Mace Donald S. Emerson Richard E. Felker Joe Leigh Simpson Sherman Elias 《黑龙江环境通报》1994,14(3):223-226
Recent reports have indicated an increased risk for fetal chromosome abnormalities, especially autosomal trisomy, in fetuses with isolated cystic hygroma, or prominent nuchal membranes, detected by ultrasonography during the first trimester. However, these reports present contradictory information regarding the prognostic significance of septations within the cystic hygroma. We evaluated, in blind fashion, 55 consecutive cases of isolatd fetal cystic hygroma detected at or before 13·9 weeks' gestation to determine the association between septations and fetal chromosome complement. Septations were associated (P<0·05) with an increased risk for fetal chromosome abnormalities. However, the incidence of chromosome abnormalities was also increased (12·5 per cent) among cases not characterized by septations. Thus, we believe it prudent to offer invasive prenatal testing to all women found to be carrying fetuses with cystic hygroma, irrespective of the presence or absence of septations. 相似文献
4.
A. Bernasconi A. L. Delezoide F. Menez E. Vuillard J. F. Oury A. Azancot 《黑龙江环境通报》2004,24(7):504-507
Congenital left ventricular diverticulum is a rare malformation. We report a case of a ruptured congenital left ventricular diverticulum in a 24-week-old fetus. The fetus was referred for a large and circumferential pericardial effusion confirmed by cross-sectional echocardiography in our tertiary fetal cardiology unit. Pericardiocentesis removed 25 mL of old hematic fluid. The fetus died 5 days later. The pathological examination showed a ruptured submitral fibrous diverticulum of the posterior wall of the left ventricle. There is no previous report in the literature of prenatal rupture of a cardiac diverticulum. The submitral location and the fibrous wall of the diverticulum is uncommon. As regards this case, we reviewed the diagnostic criteria and the outcome of 11 cases of prenatal cardiac diverticulum reported in the literature. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献
5.
For the last 6 years, sonographic signs for excessive fluid accumulation in the backs of 10- to 12-week-old fetuses have been looked for prior to transabdominal chorionic biopsy. In 1400 pregnancies, subsequent karyotype analyses revealed 28 cases of Down syndrome. In 15 ( = 54 per cent), a large fluid cushion over most of the back had been documented at the time of biopsy. Only a few chromosomally normal fetuses with the same peculiarity were observed. The cushion was also present in fetuses with trisomies 18 and 13 , and in Turner syndrome. Systematic first-trimester screening for nuchal fluid accumulation seems to be a recommended method for the detection of Down syndrome and other chromosome anomalies in young pregnant women at low risk. It compares favourably with current methods of maternal serum screening performed at 16–18 weeks which require a higher number of invasive procedures. 相似文献
6.
Lorraine Dugoff 《黑龙江环境通报》2002,22(4):316-320
The advances in ultrasound technology have made it possible to identify fetal structural abnormalities and genetic syndromes in the first trimester. First trimester prenatal diagnosis of fetal central nervous system, renal, gastrointestinal, cardiac, and skeletal abnormalities is reviewed. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
7.
8.
M. L. Brizot R. Schultz L. T. Patroni L. M. Lopes E. Armbruster-Moraes M. Zugaib 《黑龙江环境通报》2001,21(8):672-675
We report on the ultrasound features and natural history of trisomy 10. At 12 weeks' gestation in a routine scan examination, the fetus presented with increased nuchal translucency thickness, mild skin oedema, bilateral pleural effusion, marked micrognathia, cardiomegaly, unilateral talipes and reversed A-wave in the ductus venosus blood flow. Karyotyping on chorionic villus sampling (CVS) led to the diagnosis of trisomy 10, which was confirmed by fetal blood sampling at 22 weeks' gestation. As the parents opted to continue with the pregnancy, the natural history and following ultrasound features are described. This is the third case of trisomy 10 in the literature reporting on the physical features. The most frequent ultrasound findings presented in trisomy 10 are increased nuchal translucency, micrognathia, renal agenesis, facial cleft, limbabnormalities, cardiac defects and early severe growth retardation. Copyright © 2001 John Wiley & Sons, Ltd. 相似文献
9.
10.
11.
12.
Salvator Levi 《黑龙江环境通报》2002,22(4):285-295
Ultrasound for routine fetal malformation screening has been polemical from its early beginning because of the very broad range of diagnosis rates disclosed, i.e. from 13% to 82%, average 27.5%. A review of available studies is proposed to assess objectively the efficacy of ultrasound, considering also economical, ethical and methodological aspects as influential factors for choosing a routine screening policy. The utility of fetal malformation diagnosis before birth is brought forward, including second opinion, karyotyping, poly-disciplinary case discussion prior to management. Method and material of reviewed studies considerably vary and might influence the sensitivity results, as the choice of the population sample and selection of pregnant women, gestation age at screening, distribution of malformation among systems or tracts, exclusion of some fetal malformation and the routine practice of autopsy. Efficiency of screening studies is compared, and among them Radius and Eurofetus studies. Average sensitivity is finally considered as satisfactory in the daily practice when operated by trained personnel. The importance of additional factors for successful screening are emphasized such as education, equipment quality and fetal ultrasound examination at different gestation age for a better understanding of natural history of fetal morphology. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
13.
14.
Waldo Sepulveda Cecilia Be Ronald Youlton Eduardo Carstens Marcelo Reyes 《黑龙江环境通报》2001,21(9):726-728
In order to determine the significance of nuchal translucency thickness on the subsequent natural history of first-trimester fetuses with a chromosome translocation, seven consecutive cases diagnosed between 11 and 13 weeks of gestation were reviewed. Nuchal translucency measurements were successfully obtained before chorionic villus sampling (CVS) in all cases. Three fetuses had an unbalanced translocation and all were associated with increased nuchal translucency and multiple anomalies at the detailed second-trimester scan. There were no survivors in this group. The remaining four fetuses had a balanced translocation; all had normal nuchal translucency thickness and no structural anomalies were detected in the second trimester. Three of these fetuses were born at ≥35 weeks of gestation and were phenotypically normal. However, an unexpected single fetal demise occurred in a dichorionic twin pregnancy at 28 weeks of gestation. It is concluded that nuchal translucency measurements provide important prognostic information on pregnancy outcome in first-trimester fetuses with a chromosome translocation. In parents with a known balanced translocation, the detection of increased nuchal translucency at 11–14 weeks of gestation is associated with unbalanced translocations, structural anomalies and poor pregnancy outcome. Copyright © 2001 John Wiley & Sons, Ltd. 相似文献
15.
16.
J. Van Keirsbilck M. Cannie C. Robrechts T. de Ravel S. Dymarkowski T. Van den Bosch D. Van Schoubroeck 《黑龙江环境通报》2006,26(8):684-688
We present a case of sirenomelia diagnosed on a first trimester ultrasound at 10 weeks' gestation and confirmed on 3D-ultrasound and MRI. The pregnancy was terminated at 15 gestational weeks and the post-mortem examination, including RX and microscopy, is presented. The sirenomelia sequence is a rare and lethal anomaly characterized by fusion, rotation, hypotrophy or atrophy of the lower limbs and severe urogenital abnormalities leading to oligohydramnios in the second half of pregnancy. Our case illustrates that the diagnosis of sirenomelia can be reliably made in the first trimester. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
17.
18.
M. H. B. Carvalho M. L. Brizot L. M. Lopes C. H. Chiba S. Miyadahira M. Zugaib 《黑龙江环境通报》2002,22(1):1-4
The aim of this study was to evaluate the detection of fetal structural abnormalities by the 11–14 week scan. 2853 pregnant women were submitted to a routine ultrasound scan between the 11th and 14th week and the fetal skull, brain, spine, abdominal wall, limbs, stomach and bladder were examined. Following the scans the patientes were examined in the second or third trimester of pregnancy. An isolated increased nuchal translucency was not considered an abnormality. However, these patients had an early echocardiography assessment. Fetal structural abnormalities were classified as major or minor and of early or late onset. A total of 130 (4.6%) defects were identified and 29 (22.3%) of these were diagnosed at the 11–14 week scan, including nine cardiac defects associated with increased nuchal translucency. The antenatal ultrasound detection rate was 71.5%, and 31.2% were detected in the first-trimester assessment. 78.8% of the major defects were diagnosed by the prenatal scan and 37.8% by the 11–14 week scan. Fetal structural abnormalities at the 11–14 week scan were detected in approximately 22.3% of the cases, therefore, a second-trimester anomaly scan is important in routine antenatal care to increase the prenatal detection of fetal defects. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
19.