首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
Measurements of indoor radon concentrations were performed in 28 low-rise houses and 30 apartments in Patras area from December 1996 to November 1997, using nuclear track detectors. The investigation was focused on the effects of season and floor number, as well as on the existence of a basement in low-rise houses on indoor radon levels. It was found that the differences in mean radon concentrations between adjacent seasons, in a number of 61 selected sampling sites distributed in 28 houses, were statistically significant. As expected, a maximum was found in winter and a minimum in summer. The differences in mean radon concentration on different floors of the same houses were also statistically significant and followed a linear decrease from underground to 2nd floor. In addition, indoor radon concentrations in the ground floor were found to be influenced by the existence or not of a basement. The average annual radon concentration was found to be 41 Bq m(-3) for the houses, 28 Bq m(-3) for the apartments and 38 Bq m(-3) for all the dwellings. These values lead to an average effective dose equivalent of 1.1, 0.7 and 0.9 mSv y(-1), respectively. Residents living on the underground in low-rise houses, during winter, where the average effective dose equivalent is 2.1 mSv y(-1), attain the higher risk.  相似文献   

2.
Radon levels in atmospheric and aquatic systems in Cyprus have recently been measured using the radon monitor Alpha Guard. Indoor and outdoor radon levels were obtained in situ, whereas analysis of radon concentrations in water was performed using tap and ground water samples collected from several areas of the island. The average value for outdoor and indoor radon concentration is 11+/-10 and 7+/-6 Bq m(-3), respectively, and for tap and ground water 0.4 Bq l(-1) and 1.4 Bq l(-1), respectively. From these data the annual dose equivalent of airborne radon to the Cypriot population is about 0.19 mSv y(-1), which is quite low compared to the total dose equivalent of natural and man-made ionising radiation in Cyprus. Radon levels in aquatic systems are relatively low due to an exhaustive utilisation of ground water resources and also to the increased input of desalinated sea water in the water distribution network and eventually into the ground water reservoirs.  相似文献   

3.
Specific activities of the natural radionuclides (238)U, (226)Ra, (232)Th and (40)K were measured by means of gamma-ray spectrometry in surface soil samples collected from the city of Ptolemais, which is located near lignite-fired power plants. The mean activity values for (238)U, (226)Ra, (232)Th and (40)K were found to be 42+/-11, 27+/-6, 36+/-5 and 496+/-56 Bq kg(-1), respectively. These values fall within the range of typical world and Greek values for soil. The indoor radon concentration levels, which were also measured in 66 dwellings by means of SSNTD, ranged from 12 to 129 Bq m(-3), with an average value of 36+/-2 Bq m(-3). This value is close to world and Greek average values for indoor radon concentrations. The total effective dose due to outdoor external irradiation of terrestrial origin and to indoor internal irradiation from the short-lived decay products of (222)Rn was estimated to be 1.2 mSv y(-1) for adults, which is lower than the global effective dose due to natural sources of 2.4 mSv y(-1).  相似文献   

4.
Nationwide outdoor radon (222Rn) concentrations in Japan were measured to survey the environmental outdoor 222Rn level and to estimate the effective dose to the general public from 222Rn and its progeny. The 222Rn concentration was measured with a passive-type radon monitor. The 222Rn monitors were installed at about 700 points throughout Japan from 1997 to 1999. The annual mean 222Rn concentration in Japan was estimated from four quarters measurements of 47 prefectures in Japan. Nationwide outdoor mean 222Rn concentration was 6.1 Bq m(-3). This was about 40% of the indoor 222Rn concentration in Japan. The 222Rn concentration in Japan ranged from 3.3 Bq m(-3) in the Okinawa region to 9.8 Bq m(-3) in the Chugoku region, reflecting geological characteristics. Seasonal variation of outdoor 222Rn concentration was also found to be lowest in July to September, and highest in October to December. From the results of this 222Rn survey and previous indoor 222Rn survey program, the effective dose to the general public from 222Rn and its progeny was estimated to be 0.45 mSv y(-1).  相似文献   

5.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   

6.
Radon ((222)Rn) concentration was measured at indoor workplaces in Japan to estimate effective dose to the public from (222)Rn and its progeny. Measurements were made from 2000 to 2003 at 705 sites in four categories of office, factory, school and hospital. Passive type Rn monitors equipped with two sheets of polycarbonate thin films for measuring radon concentrations were installed at observation sites and replaced every 3 months to observe seasonal variations in (222)Rn concentrations. The range of annual mean (222)Rn concentrations for all sites was 1.4-182 Bq m(-3), with the arithmetic mean and standard deviation were 20.8 and 19.5 Bq m(-3). Annual mean (222)Rn concentration observed at office, factory, school and hospital were 22.6, 10.1, 28.4 and 19.8 Bq m(-3), respectively. Seasonal variations in (222)Rn concentrations at offices, schools and hospitals were similar to those found in dwellings, and variations in factories were similar to those found in outdoor environments. (222)Rn concentration observed in every quarter period was found to decrease as follows: school>office>hospital>factory. The average effective dose to the public due to (222)Rn was estimated to be 0.41 mSv y(-1) weighted by the working population. Considering the (222)Rn exposure in indoor workplaces, effective dose to the general public is estimated to be in the range from approximately 0.42 to 0.52 mSv y(-1).  相似文献   

7.
A radon survey has been carried out around the town of Niska Banja (Serbia) in a region partly located over travertine formations, showing an enhanced level of natural radioactivity. Outdoor and indoor radon concentrations were measured seasonally over the whole year, using CR-39 diffusion type radon detectors. Outdoor measurements were performed at 56 points distributed over both travertine and alluvium sediment formations. Indoor radon concentrations were measured in 102 living rooms and bedrooms of 65 family houses. In about 50% of all measurement sites, radon concentration was measured over each season separately, making it possible to estimate seasonal variations, which were then used to correct values measured over different periods, and to estimate annual values. The average annual indoor radon concentration was estimated at over 1500 Bq/m3 and at about 650 Bq/m3 in parts of Niska Banja located over travertine and alluvium sediment formations, respectively, with maximum values exceeding 6000 Bq/m3. The average value of outdoor annual radon concentration was 57 Bq/m3, with a maximum value of 168 Bq/m3. The high values of indoor and outdoor radon concentrations found at Niska Banja make this region a high natural background radiation area. Statistical analysis of our data confirms that the level of indoor radon concentration depends primarily on the underlying soil and building characteristics.  相似文献   

8.
Monitoring of radon, thoron and their daughter products was carried out in houses of Kumaun Himalaya, India using LR-115 plastic track detectors. The measurements were made in residential houses from June 1999 to May 2000 at a height of 2.5 m from ground level using a twin chamber radon dosimeter. The twin chamber radon dosimeter can record the values of radon, thoron and their decay products separately. Maximum and minimum indoor radon and thoron concentrations were evaluated and activity concentrations of radon and thoron daughters were estimated. The resulting dose rates due to radon, thoron and their decay products varied from 0.04 to 1.89 microSv/h. A detailed analysis of the distribution of radon, thoron and their decay products inside the house is also reported. The observed dose rates inside the houses of Kumaun Himalaya were found to be lower than the ICRP recommended value of 200 Bq/m3 and thus are within safe limits.  相似文献   

9.
In a radon prone area in Belgium, a dwelling with high indoor radon concentrations was identified through a passive measurement. Next, a continuous, active radon monitoring device was installed for one month. A 20-a retrospective radon assessment was also performed. The house was subsequently mitigated through active subslab depressurization with a radial fan. Afterwards the dwelling was actively monitored for several more months to observe the effects of the mitigation and to study the effect of reducing the fan power. Dose evaluations were made to evaluate the health benefit of the mitigation. It was seen that the results of the three measuring techniques before mitigation all yielded between 1700 and 2000 Bq/m3. Clear diurnal radon variations showed up only after mitigation. After mitigation, the average radon concentration fell to less than 200 Bq/m3. The yearly average dose was reduced from potentially 45 mSv/y to less than 4.5 mSv/y through mitigation. Reducing fan power to 50% did not clearly influence the amount of radon entering into the dwelling.  相似文献   

10.
Coal and its by products often contain significant amounts of radionuclides, including uranium which is the ultimate source of the radioactive gas radon. Burning of coal and the subsequent emission to the atmosphere cause the re-distribution of toxic trace elements in the environment. Due to considerable economic and environmental importance and diverse uses, the collected fly ash has become a subject of worldwide interest in recent years. In the present study, radon exhalation rate and the activity concentration of (238)U, (232)Th and (40)K radionuclides in fly ash samples from Durgapur thermal power plant (WB) have been measured by "Sealed Can technique" using LR-115 type II detectors and a low level NaI (Tl) based gamma ray spectrometer, respectively. Radon exhalation rate varied from 360.0 to 470.0 mBq m(-2)h(-1) with an average value of 406.8 mBq m(-2)h(-1). Activity concentrations of (238)U ranged from 84.8 to 126.4 Bq kg(-1) with an average value of 99.3Bqkg(-1), (232)Th ranged from 98.1 to 140.5 Bq kg(-1) with an average value of 112.9 Bq kg(-1) and (40)K ranged from 267.1 to 364.9 Bq kg(-1) with an average value of 308.9 Bq kg(-1). Radium equivalent activity obtained from activity concentrations is found to vary from 256.5 to 352.8 Bq kg(-1) with an average value of 282.5 Bq kg(-1). Absorbed gamma dose rates due to the presence of (238)U, (232)Th and (40)K in fly ash samples vary in the range 115.3-158.5 nGy h(-1) with an average value of 126.4 nGy h(-1). While the external annual effective dose rate varies from 0.14 to 0.19 mSv y(-1) with an average value of 0.15 mSv y(-1), effective dose equivalent estimated from exhalation rate varies from 42.5 to 55.2 microSv y(-1) with an average value of 47.8 microSv y(-1). Values of external hazard index H(ex) for the fly ash samples studied in this work range from 0.69 to 0.96 with a mean value of 0.77.  相似文献   

11.
In the Harghita volcanic range (Romania) there are many occurrences of dry CO(2) emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717Bq/m(3) while within the gas pools' values between 3210 and 32 781Bq/m(3) have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16mSv. No major seasonal variations of the radon activity concentrations levels have been pointed out so far in the studied mofettes.  相似文献   

12.
This paper reports on radon concentrations in dwellings from fifty different locations of India. The incorporated data were obtained using the passive solid state nuclear track detector technique. The estimated geometric mean value for India is 67.1 Bq m(-3). Chuadanga in Bangladesh had the lowest observed indoor radon concentration of 27.3 Bq m(-3) and Una in the northern part of India had the highest concentration of 281.5 Bq m(-3). This paper discusses the national geometrical mean value in terms of the national geometric mean values of other countries and also in terms of the geological influence. The estimated indoor radon levels are compared with the indoor radon levels as recommended by the International Commission on Radiation Protection (ICRP). It was observed that there are several locations in India where dwellings have higher indoor radon levels than the ICRP recommended value and requires some sort of intervention from regulating authorities. The mean value for indoor radon level given in the report of UNSCEAR 2000 for India needs to be revised.  相似文献   

13.
A new winter and summer investigation of radon concentrations in parts of the Ogof Ffynnon Ddu system at Penwyllt, South Wales, has been carried out using 100 environmental National Radiological Protection Board track etch detectors. Fifty detectors were installed in the system in December 1998 and again in August 1999 for a period of a month. The data obtained confirm that the system has moderately high radon concentrations with a system mean of 2318 Bq m(-3) in winter and 2844 Bq m(-3) in summer. Traverse means have a summer high of 3094 Bq m(-3) for OFDI to Cwm Dwr and a winter low of 1946 Bq m(-3). The extremely high concentrations approaching 20,000 Bq m(-3), reported previously from the system (Hyland, 1995), have not been reproduced. The data show that the airflow directions at the entrances are not what might have been predicted. Air appears to be largely continuously emerging from the lowest entrance but, at the higher entrances, conversely to the predictions, in winter air enters and in summer appears to be coming out or is variable. Internally, there are sites that in winter have very low radon concentrations that can only be explained by the ingress of fresh air. These are not matched in the summer experiment, again indicating that ingress of fresh air to some parts of the system is very variable. The data illustrate the complexity of airflow within a multi-entrance system but behind these variations several mean concentrations can be obtained from which an approximation of the dose likely to be received can be calculated. Using the maximum mean concentration obtained, 3094 Bq m(-3), and using the latest dose conversion, a 10 h underground trip in the Ogof Ffynnon Ddu system yields a calculated dose of 0.12 mSv. Given that the recommended limit for a member of the public is 1 mSv, this dose would be reached after about 80 h of caving in the system.  相似文献   

14.
High-resolution gamma spectrometry was used to determine the concentration of 40K, 238U and 232Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m3; the radon concentrations detected exceeded 148 Bq/m3 in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m3. The high activity of 238U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.  相似文献   

15.
The aim of this paper was to study the variations of radon and daughter nuclei during treatment in the thermal spas of Lesvos Island (Greece). For this purpose, in the thermal spas of Lesvos we have measured the radon concentrations of thermal waters, as well as indoor radon, daughter and coarse particle (>500 nm) concentrations. Various instruments and procedures were employed for measurements. Radon concentrations of thermal waters were found to lie in the range 10 Bq l(-1) and 304 Bq l(-1). Concentration peaks both for radon, radon daughter and coarse particle, were found to appear during filling of baths in the treatment process. The doses delivered to the bathers during treatment were in the range of 0.00670-0.1279 mSv per year, while the doses delivered to personnel were below 20 mSv per year.  相似文献   

16.
In this work we present the results of a 2-year survey of indoor radon variations in four cities of Lahijan, Ardabil, Sar-Ein and Namin in North and Northwest Iran. We used both passive and active measurements by solid state nuclear track detectors (SSNTDs) with CR-39 polycarbonate and PRASSI Portable radon Gas Surveyor. A total of 1124 samplers in Lahijan, Ardabil, Sar-Ein and Namin were installed. Sampling frequency was seasonal and sampling locations were randomly chosen based on dwelling structures, floors, geological formations, elevation and temperature variation parameters. For quality assurance, 281 active measurements and double sampling were carried out. Based on our results and the results of previous surveys, Ardabil and Lahijan have the second and third highest radon concentration in Iran, respectively (Ramsar is first). The average radon concentration during the year in Lahijan, Ardabil, Sar-Ein and Namin were 163, 240, 160 and 144 Bq/m(3) with medians of 160, 168, 124 and 133 Bq/m(3), respectively. These concentrations give rise to annual effective doses of 3.43 mSv/y for Lahijan and 5.00 mSv/y for Ardabil. The maximum recorded concentration was 2386 Bq/m(3) during winter in Ardabil and the minimum concentration was 55 Bq/m(3) during spring in Lahijan. Relationships between radon concentration and building materials and room ventilation were also studied. The dosimetry calculations showed that these four cities could be categorized as average natural radiation zones. The correlation coefficients relating warm and cold season radon variation data were obtained.  相似文献   

17.
The concentrations of 222Rn (radon) and its progeny with surrounding environmental gamma-dose rates were measured simultaneously inside and outside of buildings at 10 locations around Taipei and Hualien in Taiwan. For summer radon in Taiwan, indoor concentrations were estimated to be about 20 Bq m(-3) with about 90 nSv h- of environmental gamma, and outdoors, about 10 Bq m(-3) with about 70 nSv h(-1). The equilibrium factors were calculated to be 0.2-0.3 indoors and 0.3-0.4 outdoors. Indoor radon concentration had a weak positive correlation with gamma-dose rate. Since there is a possibility that high radon concentrations exist indoors during the cool season in Taiwan because of extremely low ventilation rates in the dwellings, a winter survey in January through February will be needed for future estimation of the annual effective dose.  相似文献   

18.
The results of radon activity recorded in 70 dwellings of Nurpur area, Kangra district, Himachal Pradesh, India are reported. LR-115 Type 2 films in the bare mode were exposed for four seasons of three months each covering a period of one year for the measurement of indoor radon levels. The calibration constant of 0.020 tracks cm(-2) d(-1) per Bq m(-3) has been used to express radon activity in Bq m(-3). The annual average indoor radon concentrations in 17 different villages of the area are found to vary from 168+/-46 to 429+/-71. Most of the indoor radon values lie in the range of action levels (200-600 Bq m(-3)) recommended by International Commission on Radiological Protection.  相似文献   

19.
The aim of this paper was to study the variations of radon and daughter nuclei during treatment in the thermal spas of Lesvos Island (Greece). For this purpose, in the thermal spas of Lesvos we have measured the radon concentrations of thermal waters, as well as indoor radon, daughter and coarse particle (>500 nm) concentration. Various instruments and procedures were employed for measurements. Radon concentrations of thermal waters were found to lie in the range 10 and 304 Bq l(-1). Concentration peaks both for radon, radon daughter and coarse particle, were found to appear during filling of baths in the treatment process. The doses delivered to the bathers during treatment were in the range of 0.00670 mSv per year to 0.1279 mSv per year, while the doses delivered to personnel were below 20 mSv per year.  相似文献   

20.
During 1998 regional surveys were conducted to evaluate natural radiation exposure of people in the vicinity of the six Spanish nuclear power stations. Indoor radon, external gamma dose rates outdoors and indoors and radioactivity in soil were measured in these surveys. The highest mean annual effective dose to the population was found in the surroundings of the Almaraz nuclear power plant in the province of Cáceres and was mainly due to the presence of high radon concentrations in homes. In order to make a more accurate assessment of the dose coming from the radon in this area, a new and more extensive surgery on indoor radon with a total of 380 measurements was carried out in 2000 in the Campo Ara?uelo region around the Almaraz nuclear power station. From the results obtained in this survey, a population-weighted mean annual effective dose from radon exposure of 1.7 mSv y(-1), 44% lower than that previously reported in 1998, was estimated for the whole Campo Ara?uelo region. The maximum dose value due to radon exposure, about 4 mSv y(-1), was reached in the so-called La Vera area located in the north of this region. The relationship between the indoor radon concentrates experimentally measured, the geological characteristics of this geographic area and the information provided by the radiation map of the Spanish MARNA Project is also analyzed, confirming that La Vera area should be considered as a high radon level area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号