首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
The implementation of a risk-based corrective action approach often requires consideration of soil vapor migration into buildings and potential inhalation exposure and risk to human health. Due to the uncertainty associated with models for this pathway, there may be a desire to analyze indoor air samples to validate model predictions, and this approach is followed on a somewhat frequent basis at sites where risks are considered potentially significant. Indoor air testing can be problematic for a number of reasons. Soil vapor intrusion into buildings is complex, highly dependent on site-specific conditions, and may vary over time, complicating the interpretation of indoor air measurements when the goal is to deduce the subsurface-derived component. An extensive survey of indoor air quality data sets highlights the variability in indoor volatile organic compound (VOC) concentrations and numerous sources that can lead to elevated VOC levels. The contribution from soil vapor is likely to be small relative to VOCs from other sources for most sites. In light of these challenges, we discuss how studies that use indoor air testing to assess subsurface risks could be improved. To provide added perspective, we conclude by comparing indoor air concentrations and risks arising from subsurface VOCs, predicted using standard model equations for soil vapor fate and intrusion into buildings, to those associated with indoor sources.  相似文献   

2.
ABSTRACT

The implementation of a risk-based corrective action approach often requires consideration of soil vapor migration into buildings and potential inhalation exposure and risk to human health. Due to the uncertainty associated with models for this pathway, there may be a desire to analyze indoor air samples to validate model predictions, and this approach is followed on a somewhat frequent basis at sites where risks are considered potentially significant. Indoor air testing can be problematic for a number of reasons. Soil vapor intrusion into buildings is complex, highly dependent on site-specific conditions, and may vary over time, complicating the interpretation of indoor air measurements when the goal is to deduce the subsurface-derived component. An extensive survey of indoor air quality data sets highlights the variability in indoor volatile organic compound (VOC) concentrations and numerous sources that can lead to elevated VOC levels. The contribution from soil vapor is likely to be small relative to VOCs from other sources for most sites. In light of these challenges, we discuss how studies that use indoor air testing to assess subsurface risks could be improved. To provide added perspective, we conclude by comparing indoor air concentrations and risks arising from subsurface VOCs, predicted using standard model equations for soil vapor fate and intrusion into buildings, to those associated with indoor sources.  相似文献   

3.
This study examined the indoor concentrations of a wide range of volatile organic compounds (VOCs) in currently built new apartments every month over a 24-month period and the source characteristics of indoor VOCs. The indoor total VOC (TVOC) concentrations exhibited a decreasing tendency over the 24-month follow-up period. Similar to TVOCs, the median indoor concentrations of 33 of 40 individual VOCs (all except for naphthalene and six halogenated VOCs) revealed decreasing tendencies. In contrast, the indoor concentrations of the six halogenated VOCs did not reveal any definite trend with time. Moreover, the indoor concentrations of those halogenated VOCs were similar to the outdoor concentrations, suggesting the absence of any notable indoor sources of halogenated VOCs. For naphthalene (NT), the indoor concentrations were significantly higher than the outdoor concentrations, suggesting the presence of indoor NT source(s). The floor/wall coverings (39 %) were the most influential indoor source of indoor VOCs, followed by household cleaning products (32 %), wood paneling/furniture (17 %), paints (7 %), and moth repellents (5 %).  相似文献   

4.
Volatile organic compounds (VOCs) are the cause of indoor air pollution and are readily emitted from furniture and cleaning agents. In Taiwan, the concentrations of indoor VOCs range roughly from 1 to 10 ppm. It is important to effectively reduce indoor VOC emissions and establish the implementation of long-term, low-cost, controlled techniques such as those found in the ultraviolet/titanium dioxide (UV/TiO2) control systems. This study evaluates the performance of a photoreactor activated by visible irradiation and packed with TiO2/quartz or TiO2/mobile catalytic material number 41 (MCM-41). The photocatalysts tested include commercial TiO2 (Degussa P-25) and synthesized TiO2 with a modified sol-gel process. The UV light had a wavelength of 365 nm and contained an 8-W, low-pressure mercury lamp. Reactants and products were analyzed quantitatively by using gas chromatography with a flame-ionization detector. It is important to understand the influence of such operational parameters, such as concentration of pollutant, temperature, and retention time of processing. The indoor concentrations of VOCs varied from 2 to 10 ppm. Additionally, the temperatures ranged from 15 to 35 degrees C and the retention time tested from 2 to 8.2 sec. The results show that quartz with TiO2 had a better photoreductive efficiency than quartz with MCM-41. The toluene degradation efficiency of 77.4% with UV/TiO2/quartz was larger than that of 54.4% with the UV/TiO2/MCM-41 system under 10-min reaction time. The degradation efficiency of the UV/TiO2 system decreased with the increasing concentrations of indoor VOCs. The toluene degradation efficiency at 2 ppm was approximately 5 times greater than that at 10 ppm. The photoreduction rate of the VOCs was also evaluated with the Langmuir-Hinshewood model and was shown to be pseudo-first-order kinetics.  相似文献   

5.
Abstract

Volatile organic compounds (VOCs) are a major concern for indoor air pollution because of the impacts on human health. In recent years, interest has increased in the development and design of activated carbon filters for removing VOCs from indoor air. Although extensive information is available on sources, concentrations, and types of indoor VOCs, there is little or no information on the performance of indoor air adsorption systems for removing low concentrations of primary VOCs. Filter designs need to consider various factors such as empty bed contact time, humidity effects, competitive adsorption, and feed concentration variations, whereas adsorption capacities of the indoor VOCs at the indoor concentration levels are important parameters for filter design. A preliminary assessment of the feasibility of using adsorption filters to remove low concentrations of primary VOCs can be performed. This work relates the information (including VOC classes in indoor air, the typical indoor concentrations, and the adsorption isotherms) with the design of a particular adsorbent/adsorbates system. As groundwork for filter design and development, this study selects the primary VOCs in indoor air of residences, schools, and offices in different geographical areas (North America, Europe, and Asia) on the basis of occurrence, concentrations, and health effects. Activated carbon fiber cloths (ACFCs) are chosen as the adsorbents of interest. It is demonstrated that the isotherm of a VOC (e.g., toluene on the ACFC) at typical indoor concentrations—parts per billion by volume (ppbv) level—is different than the isotherm at parts per million by volume (ppmv) levels reported in the publications. The isotherms at the typical indoor concentrations for the selected primary VOCs are estimated using the Dubinin–Radushkevitch equation. The maximum specific throughput for an indoor VOC removal system to remove benzene is calculated as a worst-case scenario. It is shown that VOC adsorption capacity is an important indicator of a filter’s lifetime and needs to be studied at the appropriate concentration range. Future work requires better understanding of the realistic VOC concentrations and isotherms in indoor environments to efficiently utilize adsorbents.  相似文献   

6.
Interactions between volatile organic compounds (VOCs) and vinyl flooring (VF), a relatively homogenous, diffusion-controlled building material, were characterized. The sorption/desorption behavior of VF was investigated using single-component and binary systems of seven common VOCs ranging in molecular weight from n-butanol to n-pentadecane. The simultaneous sorption of VOCs and water vapor by VF was also investigated. Rapid determination of the material/air partition coefficient (K) and the material-phase diffusion coefficient (D) for each VOC was achieved by placing thin VF slabs in a dynamic microbalance and subjecting them to controlled sorption/desorption cycles. K and D are shown to be independent of concentration for all of the VOCs and water vapor. For the four alkane VOCs studied, K correlates well with vapor pressure and D correlates well with molecular weight, providing a means to estimate these parameters for other alkane VOCs. While the simultaneous sorption of a binary mixture of VOCs is non-competitive, the presence of water vapor increases the uptake of VOCs by VF. This approach can be applied to other diffusion-controlled materials and should facilitate the prediction of their source/sink behavior using physically-based models.  相似文献   

7.
Indoor air pollution caused by volatile organic compounds (VOCs) may affect the health and well-being of inhabitants. Uptake and release of these compounds by and from indoor materials alter their concentrations in indoor air: uptake will lower peak concentrations, whereas subsequent (slow) release at lower concentration levels will prolong the presence of VOCs in indoor air. An experimental set-up has been implemented where indoor materials are placed as a “membrane” separating two air compartments. Both compartments – consisting of Field and Laboratory Emission Cells FLECs – are constantly flushed with air, one air stream containing a mixture of 20 VOCs, and concentrations in both compartments are measured after 1 h. Ten materials usually covering extensive surfaces indoors were consecutively exposed to the vapour mixture at concentration levels typically found in indoor environments. Under the chosen experimental conditions, five of these materials exhibited a permeability high enough that VOCs could be detected on the other side. Mass transport of VOCs into and through indoor materials has therefore been confirmed by experiment. The set-up allows for a quick screening of indoor materials with respect to their sorption capacity and permeability.  相似文献   

8.
Two computational methods are proposed for estimation of the emission rate of volatile organic compounds (VOCs) from solvent-based indoor coating materials based on the knowledge of product formulation. The first method utilizes two previously developed mass transfer models with two key parameters – the total vapor pressure and the average molecular weight for total volatile organic compounds (TVOCs) – being estimated based on the VOC contents in the product. The second method is based on a simple, first-order decay model with its parameters being estimated from the properties of both the source and the environment. All the model parameters can be readily obtained. Detailed procedures for computing the key parameters are described by using examples. The predictive errors were evaluated with small chamber data, and the results were satisfactory. Thus, the proposed methods provide a way to predict the VOC emissions in the indoor environment without having to conduct costly chamber testing. The two proposed methods work for both TVOCs and individual VOCs. Pros and cons for each method are discussed.  相似文献   

9.
Interest in indoor air quality is steadily increasing. Exposure to volatile organic compounds (VOCs) is associated with health effects as diverse as childhood respiratory disease, lung cancer and cardiovascular disease. In an effort to assess the environmental impact indoors from possible sources of VOCs, such as (i) open oil lakes, (ii) chemical and petrochemical industries and (iii) indoor pollution from household items, concentrations of aliphatic and aromatic VOCs, comprising n-hexane to n-hexadecane, benzene, toluene, xylene, ethyl benzene, methanol and o-dichlorobenzene, were measured in indoor air samples from seven different cities in Kuwait using a gas chromatograph. The data for the period March to May 1993 are presented. The VOCs, as measured, were surprisingly low and they are below the concentrations set by the American Hygienists Association. However, although the concentration of the estimated VOCs being low, were cumulative effects of them entering the human body and water sources cannot be ruled out.  相似文献   

10.
Jo WK  Park KH 《Chemosphere》2004,57(7):555-565
The current study evaluated the technical feasibility of applying TiO2 photocatalysis to the removal of low-ppb concentrations of volatile organic compounds (VOCs) commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) for VOCs, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) in relation to the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs exhibited any significant dependence on the RH, which is inconsistent with a previous study where, under conditions of low humidity and a ppm toluene inlet level, a drop in the PCO efficiency was reported with a decreasing humidity. However, the other four parameters (HD, RM, FT, and IPS) were found to be important for better VOC removal efficiencies as regards the application of TiO2 photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues was up to nearly 100%, and the CO generated during PCO was a negligible addition to indoor CO levels. Accordingly, a PCO reactor would appear to be an important tool in the effort to improve non-occupational indoor air quality.  相似文献   

11.
Volatile organic compounds (VOCs) are found in indoor air, and many of these can affect human health (e.g. formaldehyde and benzene are carcinogenic). Plants affect the levels of VOCs in indoor environments, thus they represent a potential green solution for improving indoor air quality that at the same time can improve human health. This article reviews scientific studies of plants’ ability to remove VOCs from indoor air. The focus of the review is on pathways of VOC removal by the plants and factors affecting the efficiency and rate of VOC removal by plants. Laboratory based studies indicate that plant induced removal of VOCs is a combination of direct (e.g. absorption) and indirect (e.g. biotransformation by microorganisms) mechanisms. They also demonstrate that plants’ rate of reducing the level of VOCs is influenced by a number of factors such as plant species, light intensity and VOC concentration. For instance, an increase in light intensity has in some studies been shown to lead to an increase in removal of a pollutant. Studies conducted in real-life settings such as offices and homes are few and show mixed results.  相似文献   

12.
We conducted a comparative study on the indoor air quality for Japan and China to investigate aromatic volatile organic compounds (VOCs) in indoor microenvironments (living room, bedroom, and kitchen) and outdoors in summer and winter during 2006–2007. Samples were taken from Shizuoka in Japan and Hangzhou in China, which are urban cities with similar latitudes. Throughout the samplings, the indoor and outdoor concentrations of many of the targeted VOCs (benzene, toluene, ethylbenzene, xylenes, and trimethylbenzenes) in China were significantly higher than those in Japan. The indoor concentrations of VOCs in Japan were somewhat consistent with those outdoors, whereas those in China tended to be higher than those outdoors. Here, we investigated the differences in VOC concentrations between Japan and China. Compositional analysis of indoor and outdoor VOCs showed bilateral differences; the contribution of benzene in China was remarkably higher than that in Japan. Significant correlations (p < 0.05) for benzene were observed among the concentrations in indoor microenvironments and between the outdoors and living rooms or kitchens in Japan. In China, however, significant correlations were observed only between living rooms and bedrooms. These findings suggest differences in strengths of indoor VOC emissions between Japan and China. The source characterizations were also investigated using principal component analysis/absolute principal component scores. It was found that outdoor sources including vehicle emission and industrial sources, and human activity could be significant sources of indoor VOC pollution in Japan and China respectively. In addition, the lifetime cancer risks estimated from unit risks and geometric mean indoor concentrations of carcinogenic VOCs were 2.3 × 10?5 in Japan and 21 × 10?5 in China, indicating that the exposure risks in China were approximately 10 times higher than those in Japan.  相似文献   

13.
In 1997, Homeswest in western Australia and Murdoch University developed a project to construct low-allergen houses (LAHs) in a newly developed suburb. Before the construction of LAHs, all potential volatile organic compound (VOC) emission materials used in LAHs are required to be measured to ensure that they are low total VOC (TVOC) emission materials. This program was developed based on this purpose. In recent times, the number of complaints about indoor air pollution caused by VOCs has increased. A number of surveys of indoor VOCs have indicated that many indoor materials contribute to indoor air pollution. Although some studies have been conducted on the characteristics of VOC emissions from adhesives, most of them were focused on VOC emissions from floor adhesives. Few measurements of VOC emissions from adhesives used for wood, fabrics, and leather are available. Furthermore, most research on VOC emissions from adhesives has been done in countries with cool climates, where ventilation rates in the indoor environment are lower than those in Mediterranean climates, due to energy conservation. VOCs emitted from adhesives have not been sufficiently researched to prepare an emission inventory to predict indoor air quality and to determine both exposure levels for the Australian population and the most appropriate strategies to reduce exposure. An environmental test chamber with controlled temperature, relative humidity, and airflow rate was used to evaluate emissions of TVOCs from three adhesives used frequently in Australia. The quantity of TVOC emissions was measured by a gas chromatography/flame ionization detector. The primary VOCs emitted from each adhesive were detected by gas chromatography/mass spectrometry. The temporal change of TVOC concentrations emitted from each adhesive was tested. A double-exponential equation was then developed to evaluate the characteristics of TVOC emissions from these three adhesives. With this double-exponential model, the physical processes of TVOC emissions can be explained, and a variety of emission parameters can be calculated. These emission parameters could be used to estimate real indoor TVOC concentrations in Mediterranean climates.  相似文献   

14.
It is generally believed that indoor air pollution, one way or another may cause indoor air complaints. However, any association between volatile organic compounds (VOCs) concentrations and increase of indoor climate complaints, like the sick-building syndrome symptoms, is not straightforward. The reported symptom rates of, in particular, eye and upper airway irritation cannot generally be explained by our present knowledge of common chemically non-reactive VOCs measured indoors. Recently, experimental evidence has shown those chemical reactions between ozone (either with or without nitrogen dioxide) and unsaturated organic compounds (e.g. from citrus and pine oils) produce strong eye and airway irritating species. These have not yet been well characterised by conventional sampling and analytical techniques. The chemical reactions can occur indoors, and there is indirect evidence that they are associated with eye and airway irritation. However, many other volatile and non-volatile organic compounds have not generally been measured which could equally well have potent biological effects and cause an increase of complaint rates, and posses a health/comfort risk. As a consequence, it is recommended to use a broader analytical window of organic compounds than the classic VOC window as defined by the World Health Organisation. It may include hitherto not yet sampled or identified intermediary species (e.g., radicals, hydroperoxides and ionic compounds like detergents) as well as species deposited onto particles. Additionally, sampling strategies including emission testing of building products should carefully be linked to the measurement of organic compounds that are expected, based on the best available toxicological knowledge, to have biological effects at indoor concentrations.  相似文献   

15.
Outdoor and indoor environments are profitably viewed as parts of a whole connected through various physical and chemical interactions. This paper examines four phenomena that share a dependence on vapor pressure—the extent to which an organic compound in the gas phase sorbs on airborne particles, sorbs on surfaces, sorbs on particles collected on a filter or activates trigeminal nerve receptors. It also defines a new equilibrium coefficient for the partitioning of organic compounds between an airstream and particles collected by a filter in that airstream. Gas/particle partitioning has been studied extensively outdoors, but sparingly indoors. Gas/surface partitioning occurs primarily indoors while gas/filter partitioning occurs at the interface between outdoors and indoors. Activation of trigeminal nerve receptors occurs at the human interface. The logarithm of an organic compound's saturation vapor pressure correlates in a linear fashion with the logarithms of equilibrium coefficients characteristic of each of these four phenomena. Since, to a rough approximation, the log of an organic compound's vapor pressure scales with its molecular weight, molecular weight can be used to make first estimates of the above processes. For typical indoor conditions, only larger compounds with lower-saturation vapor pressures (e.g., tetracosane, pentacosane, or di-2-ethylhexyl phthalate) have airborne particle concentrations comparable to or larger than gas phase concentrations. Regardless of a compound's vapor pressure, the total mass sorbed on indoor airborne particles is quite small compared to the total sorbed on indoor surfaces, reflecting the large difference in surface areas between particles within a room and surfaces within a room. If the actual surface areas are considered, accounting for roughness and porosity, the surface concentration of organics sorbed on typical airborne particles appears to be comparable to the surface concentration of organics sorbed on indoor carpets, walls and other materials (based on data from several studies in the literature). Mirroring the importance of phase distributions outdoors, an organic compound's indoor lifetime, fate and even health impacts depend on its distribution between phases and among surfaces.  相似文献   

16.
Consumer products can emit chlorinated volatile organic compounds (CVOCs) that complicate vapor intrusion (VI) assessments. Assessment protocols acknowledge the need to remove these products during VI investigations, but they can be problematic to identify and locate. Predicting if the products cause detectable air concentrations is also difficult since emission rate information is limited and can vary with product use and age. In this study, the emission rates of 1,2-dichloroethane, trichloroethene, tetrachloroethene, and carbon tetrachloride from four consumer products identified as indoor sources during VI field investigations were measured under laboratory conditions using a flow through system. Emissions of PCE from an adhesive container tube ranged from 1.33 ± 1.13 μg/min (unopened) to 23.9 ± 2.93 μg/min (previously opened). The laboratory-measured emission rates were used to estimate indoor air concentrations, which were then compared to concentrations measured after the products placed were into an actual residence. The estimated and measured indoor air concentrations were generally comparable, showing that emission rate information can be used to determine the relative impact of internal CVOC sources.  相似文献   

17.
Human breath emissions of VOCs.   总被引:5,自引:0,他引:5  
The medical community has long recognized that humans exhale volatile organic compounds (VOCs). Several studies have quantified emissions of VOCs from human breath, with values ranging widely due to variation between and within individuals. The authors have measured human breath concentrations of isoprene and pentane. The major VOCs in the breath of healthy individuals are isoprene (12-580 ppb), acetone (1.2-1,880 ppb), ethanol (13-1,000 ppb), methanol (160-2,000 ppb) and other alcohols. In this study, we give a brief summary of VOC measurements in human breath and discuss their implications for indoor concentrations of these compounds, their contributions to regional and global emissions budgets, and potential ambient air sampling artifacts. Though human breath emissions are a negligible source of VOCs on regional and global scales (less than 4% and 0.3%, respectively), simple box model calculations indicate that they may become an important (and sometimes major) indoor source of VOCs under crowded conditions. Human breath emissions are generally not taken into account in indoor air studies, and results from this study suggest that they should be.  相似文献   

18.
污染土壤的物理/化学修复   总被引:10,自引:1,他引:9  
将土壤污染物分为非卤代VOCs、卤代VOCs、非卤代SVOCs、无机物等8大类型,并在分析污染土壤原位修复和异位修复两种方式不同特点的基础上,根据各种修复技术的不同作用原理,较为全面地介绍了目前国内外各种物理/化学修复的技术原理、适用性、局限性、实施时间及处理成本等,具体包括化学淋洗、蒸汽抽提、强化破裂、空气喷射、可渗透反应墙、固化/稳定化、电动学、物理分离、热解吸、玻璃化等修复技术.针对几种常见的土壤污染类型,列举了一些可行的组合修复工艺.  相似文献   

19.
Volatile organic compounds (VOCs) are prevalent components of indoor air pollution. Among the approaches to remove VOCs from indoor air, photocatalytic oxidation (PCO) is regarded as a promising method. This paper is a review of the status of research on PCO purification of VOCs in indoor air. The review and discussion concentrate on the preparation and coating of various photocatalytic catalysts; different kinetic experiments and models; novel methods for measuring kinetic parameters; reaction pathways; intermediates generated by PCO; and an overview of various PCO reactors and their models described in the literature. Some recommendations are made for future work to evaluate the performance of photocatalytic catalysts, to reduce the generation of harmful intermediates and to design new PCO reactors with integrated UV source and reaction surface.  相似文献   

20.
This study investigates the volatile organic compounds (VOCs) constituents and concentration levels on a new university campus, where all of the buildings including classrooms and student dormitories were newly built and decorated within 1 year. Investigated indoor environments include dormitories, classrooms, and the library. About 30 dormitory buildings with different furniture loading ratios were measured. The characteristics of the indoor VOCs species are analyzed and possible sources are identified. The VOCs were analyzed with gas chromatography–mass spectroscopy (GC-MS). It was found that the average total VOC (TVOC) concentration can reach 2.44 mg/m3. Alkenes were the most abundant VOCs in dormitory rooms, contributing up to 86.5% of the total VOCs concentration. The concentration of α-pinene is the highest among the alkenes. Unlike the dormitory rooms, there is almost no room with TVOC concentration above 0.6 mg/m3 in classroom and library buildings. Formaldehyde concentration in the dormitory rooms increased about 23.7% after the installation of furniture, and the highest level reached 0.068 mg/m3. Ammonia released from the building antifreeze material results in an average indoor concentration of 0.28 mg/m3, which is 100% over the threshold and should be seriously considered. Further experiments were conducted to analyze the source of the α-pinene and some alkanes in dormitory rooms. The results showed that the α-pinene mainly comes from the bed boards, while the wardrobes are the main sources of alkanes. The contribution of the pinewood bed boards to the α-pinene and TVOC concentration can reach up to above 90%. The same type rooms were sampled 1 year later and the decay rate of α-pinene is quite high, close to 100%, so that it almost cannot be detected in the sampled rooms.

Implications: Analysis of indoor volatile organic compounds (VOCs) in newly built campus buildings in China identified the specific constituents of indoor VOCs contaminants exposed to Chinese college students. The main detected substances α-pinene, β-pinene, and 3-carene originated from solid wood bed boards and should be seriously considered. In addition, the contribution rates of building structure materials and furniture to specific VOCs constituents are quantitative calculated. Also, the decay rates of these specific constituents within 1 year are also quantitative calculated in this paper. This study can help us to better understand the sources and concentration levels of VOC contaminants in campus buildings, and to help select appropriate materials in buildings.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号