首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A procedure is detailed for the selective analysis of trace aluminum by flame atomic absorption spectrophotometer coupled with off-line column separation and preconcentration. Chelating resin was synthesized by covalent functionalization of Amberlite XAD-16 by 2-(2-hydroxyphenyl) benzoxazole. The modified resin was characterized using FT-IR spectroscopy, energy dispersive x-ray analysis, elemental analysis, thermogravimetric analysis/differential thermal analysis, and minimum energy run. The optimum sorption was at pH 9?±?0.1 with corresponding t 1/2 of only 7 min. Many competitive anions and cations studied did not interfere at all in the selective determination of Al(III), at the optimized conditions. The resin shows maximum sorption capacity of 21.58 mg g?1 and can be regenerated up to 75 cycles without any discernible capacity loss. The Langmuir isotherm model provides the better correlation of the experimental data (r 2?=?0.999) in comparison to Freundlich isotherm model, while the Scatchard analysis revealed homogeneous binding sites in the chelating resin. Analytical figures of merit were evaluated by accuracy (standard reference materials and recovery experiment), precision (RSD <5 %), and detection limit (2.8 μg L?1). The applicability was demonstrated by analysis of trace aluminum in biological, environmental, and food samples.  相似文献   

2.
An on-site solid-phase extraction, consisting of the sorption, the separation and the elution function units, was designed for in situ preconcentration of heavy metals ions. The D401 resin powder was employed as sorbent to capture Pb2+, Cu2+, Zn2+, Cd2+, Co2+, and Ni2+, and then they desorbed with 2 mol/L nitric acid as eluent. Under the optimized conditions, these heavy metals ions in West Lake, Taihu Lake, and Yangtze River of China were captured and then determined by ICP-OES with the recovery of 92.5% to 111.5%. The on-site solid-phase extraction achieved a quick preconcentration of heavy metals to avoid the transport and storage of a large volume water sample. It is suitable for in situ monitoring of water quality in mountains, tablelands or other remote areas.  相似文献   

3.
A new method for separation and preconcentration of trace amounts of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) ions in various matrices was proposed. The method is based on the adsorption and chelation of the metal ions on a column containing Amberlite XAD-1180 resin impregnated with 1-(2-thiazolylazo)-2-naphthol (TAN) reagent prior to their determination by flame atomic absorption spectrometry (FAAS). The effect of pH, type, concentration and volume of eluent, sample volume, flow rates of sample and elution solutions, and interfering ions have been investigated. The optimum pH for simultaneous retention of all the metal ions was 9. Eluent for quantitative elution was 20 ml of 2 mol l(-1) HNO(3). The optimum sample and eluent flow rates were found as 4 ml min(-1), and also sample volume was 500 ml, except for Mn (87% recovery). The sorption capacity of the resin was found to be 0.77, 0.41, 0.57, and 0.30 mg g(-1) for Cu(II), Ni(II), Cd(II), and Mn(II), respectively. The preconcentration factor of the method was 200 for Cu(II), 150 for Pb(II), 100 for Cd(II) and Ni(II), and 50 for Mn(II). The recovery values for all of the metal ions were > or = 95% and relative standard deviations (RSDs) were < or = 5.1%. The detection limit values were in the range of 0.03 and 1.19 microg l(-1). The accuracy of the method was confirmed by analysing the certified reference materials (TMDA 54.4 fortified lake water and GBW 07605 tea samples) and the recovery studies. This procedure was applied to the determination of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) in waste water and lake water samples.  相似文献   

4.
In this work, two N/S-containing chelating agents 2-(4-methoxybenzylideneamino)thiophenol (2-4-MBAT) and 2-(4-chlorobenzylideneamino) benzenethiol (2-4-CBABT) were synthesized as new sorbents and were used for preconcentration of Zn(2+) and Cu(2+) ions in food and vegetable samples. In the proposed procedure, the trace amount of Zn(2+) and Cu(2+) ions from 250?mL of sample solution at pH?=?5.0 was preconcentrated by 1?g of activated carbon (AC) loaded with 15?mg of 2-4-MBAT and 2-4-CBABT separately. The breakthrough volumes (maximum sample volume that their metal ions quantitatively can be enriched) for solid-phase extraction (SPE) procedure based on the AC modified with 2-4-MBAT and 2-4-CBABT were 800 and 750?mL, respectively. The sorbed Zn(2+) and Cu(2+) ions were efficiently eluted by 8?mL of 4?mol?L(-1) HNO(3) and preconcentration factor of 112.5 and 93.7 and experimental enhancement factor of 30 and 35 ions were obtained for Zn(2+) and Cu(2+), respectively. The application of this enrichment procedure allowed the extraction of trace metal ions with recoveries exceeding of 90%.  相似文献   

5.
Amberlite XAD-4 resin functionalized with β-nitroso-α-naphthol was applied to an online system for the preconcentration and determination of uranium. U (VI) ions were retained on the minicolumn at an appropriate pH and then desorbed with acid solution. The amount of uranium in the eluate was measured spectrophotometrically at 650 nm using Arsenazo III as a colorimetric reagent. The limit of detection and the preconcentration factor were 1.8 μg L???1 and 10, respectively. The chemical and flow variables affecting the preconcentration were studied. The influence of several ions on the system was also investigated. The method was successfully applied for the evaluation of uranium in water and in effluent samples.  相似文献   

6.
Highly rapid and selective vortex-assisted liquid–liquid microextraction based on solidification of organic drop has been used for determination of cobalt ion. 2-Nitroso-1-naphthol (2N1N) was used as a selective complexing agent to form stable cobalt–2N1N complex which can be extracted with 1-undecanol at a short time by the assistance of vortex agitator system followed by its determination using flame atomic absorption spectrometry. In vortex assisted, vigorous vortex stream as well as the vibrant effect of vortex system cause very fine droplets of extraction solvent to be produced and extraction occurred at a short time. Some parameters influencing the extraction process such as pH of samples, concentration of 2-nitroso-1-naphthol, extraction solvent volume, extraction time, ionic strength and surfactant addition, as well as interferences were evaluated in detail and optimum conditions were selected. At the optimum conditions, the calibration curve was linear in the range of 15 to 400 μg L?1 of cobalt ions. The relative standard deviation based on ten replicate analysis of sample solution containing 50 μg L?1 of cobalt was 3.4 %. The detection limit (calculated as the concentration equivalent to three times of the standard deviation of the blank divided by the slope of the calibration curve after preconcentration) was 5.4 μg L?1. The accuracy of the proposed method was successfully evaluated by the analysis of certified reference materials. This selective and highly rapid method was used for determination of cobalt ions in different water samples.  相似文献   

7.
In the present study, a separation/preconcentration procedure for determination of aluminum in water samples has been developed by using a new atomic absorption spectrometer concept with a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator, and a charge-coupled device array detector. Sample solution pH, sample volume, flow rate of sample solution, volume, and concentration of eluent for solid-phase extraction of Al chelates with 4-[(dicyanomethyl)diazenyl] benzoic acid on polymeric resin (Duolite XAD-761) have been investigated. The adsorbed aluminum on resin was eluted with 5 mL of 2 mol L-1 HNO3 and its concentration was determined by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Under the optimal conditions, limit of detection obtained with HR-CS FAAS and Line Source FAAS (LS-FAAS) were 0.49 μg L?1 and 3.91 μg L?1, respectively. The accuracy of the procedure was confirmed by analyzing certified materials (NIST SRM 1643e, Trace elements in water) and spiked real samples. The developed procedure was successfully applied to water samples.  相似文献   

8.
New solid-phase extractor (MWCNTs-5-ASA) was synthesized via covalent immobilization of 5-aminsalicylic acid onto multi-walled carbon nanotubes (MWCNs). The success of the functionalization process was confirmed using Fourier transform infrared spectroscopy, scanning electron microscope, and surface coverage determination. Batch experiments were conducted as a function of pH to explore MWCNTs-5-ASA efficiency to extract several metal ions viz., Cr(III), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pb(II). It was found that Pb(II) exhibits the highest extraction percentage with maximum adsorption capacity 32.75 mg g?1. Its binding performance was well fitted with Langmuir sorption isotherm. On the other hand, the selective separation and preconcentration of trace Pb(II) under dynamic conditions prior to determination by inductively coupled plasma-optical emission spectrometry was investigated under different parameters. These included the rate of flow and volume of sample solution, in addition to the type of the eluate, its volume and concentration. The effect of a variety of foreign ions on the recovery percentage was also evaluated. Trace Pb(II) ions present in 500 mL aqueous solution adjusted to pH 4.0 were retained on 50 mg of MWCNTs-5-ASA and completely eluted using 4.0 mL of 2 M HNO3. The limit of detection and the precision of the method were 0.25 ng mL?1 and 2.8 %, respectively (N?=?5). This methodology has been applied for the determination of Pb(II) in water samples with good results.  相似文献   

9.
Total dissolved trace and major metals and their partitioning in porewater sediment have been investigated at two sites in the Seine River estuary (France). For this purpose, solid phase extraction (SPE) has been employed using specific chelating resins for the separation and preconcentration of organic and inorganic forms of studied metals under controlled (N2) inert atmosphere. In fact, the study is focused on the development of a method for sample collection and handling under inert atmosphere in order to avoid some potential artefacts of the extracted porewater, to preserve the samples from possible chemical oxidation changes and to determine metals partitioning between organic and inorganic forms. For this point, a separation and preconcentration method using two columns in series (chelamine and C18 columns) was used. The trace and major metals fixed on the two resins for all determinations were stripped by nitric acid (2 M) and analyzed by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) and Zeeman Graphite Furnace Atomic Absorption Spectroscopy (ZGF-AAS). The relationship between the distribution of metals and physico-chemical parameters such as pH and Eh (redox potential) as a function of depth was discussed. Some tendency in the distributions and seasonal variability of these traces and major metals are improved. The concentrations for all studied metals decreased as a function of depth where iron and manganese were found at mg L(-1) levels and other metals were found at [micro sign]g L(-1) levels, as well as there were significant fractions of all metals (except of manganese) which were complexed by organic matter. The comparison of data for the major elements (Fe and Mn), obtained by direct determination (without preconcentration) and preconcentration, show a very good recovery.  相似文献   

10.
Nascent Amberlite XAD-4 has been used as the polymeric support for the synthesis of a stable extractor of metal ions, by incorporating phthalic acid through azo bridging. Elemental analyses and infra-red spectral and thermal studies were carried out for its characterization. The water regain value and hydrogen ion capacity were found to be 12.50 and 5.75 mmol g?1, respectively. The optimum pH range for the maximum sorption of Ni(II), Mn(II), Cu(II), Zn(II), Cd(II), Cr(III), and Co(II) was observed at pH 5.5–8.0 with the corresponding half-loading time (t 1/2) of 9, 5, 9, 9, 3, 9, and 5 min, respectively. The preconcentration factor for Ni(II), Mn(II), Cu(II), Zn(II), Cd(II), Cr(III), and Co(II) are 190, 190, 190, 180, 180, 160, and 160, with the corresponding limit of preconcentration in the range of 5.25–6.25 μg L?1. The detection limits, for flame atomic absorption spectrophotometry, were found to be 0.62, 0.60, 0.65, 0.75, 0.72, 0.84, and 0.85 μg L?1, respectively. Method has been successfully applied to the analysis of water samples, multivitamin formulations, infant food substitutes, hydrogenated oil, and fishes.  相似文献   

11.
The effective determination of heavy metals from environmental media is among the most important issues for many industrialized countries. The interaction between RS-N, as novel heavy metal probe, and metal ions was studied. RS-N shows selective color change from colorless to pink in the presence of Hg2+ in methanol/water solvent and the UV–Vis study shows peak at 560 nm. Fluorescence data revealed that the fluorescence enhance of RS-N by Hg2+ dramatically was the result of the formation of [Hg2+]RS-N complex. The effective association constants (K a ) were 3.97?×?105 and 0.204?×?105 M?1 for Hg2+ and Cu2+ to RS-N, respectively. The thermodynamic parameters, enthalpy change (ΔH 0) and entropy change (ΔS 0), were calculated to be ?6.431?±?0.226 kJ/mol and ?0.129?±?0.008 J/K/mol, respectively, according to van’t Hoff equation on the basis of Gibbs free energy (ΔG 0) ranged from ?33.8326 to ?28.5389 kJ/mol.  相似文献   

12.
The present study reports on the application of modified groundnut shell as a new, easily prepared, and stable sorbent for the extraction of trace amount of Cr(III) in aqueous solution. 2-Hydroxybenzaldiminoglycine was immobilized on groundnut shells in alkaline medium and then used as a solid phase for the column preconcentration of Cr(III). The elution was carried out with 3 mL of 2 mol?L?1 HCl. The amount of eluted Cr(III) was determined by spectrophotometry using cefaclor as a complexing reagent and by flame atomic absorption spectrometry (FAAS). Different experimental variables such as pH, amount of solid sorbent, volume and concentration of eluent, sample and eluent flow rate, and interference of other metal ions on the retention of Cr(III) were studied. Under the optimized conditions, the calibration curves were found to be linear over the concentration range of 13–104 and 10–75 μg?L?1 with a detection limit of 3.64 and 1.24 μg?L?1 for spectrophotometric method and FAAS, respectively. An enrichment factor of 200 and RSD of ±1.19–1.49 % for five successive determinations of 25 μg?L?1 were achieved. The column preconcentration was successfully applied to the analysis of tap water and underground water samples.  相似文献   

13.
Quercetin (3,3,4,5,7-pentahydroxyflavone) chemically bonded through pyran rearrangement on modified controlled pore silica glass (QCPSG) with a capacity 0.213 mmol/g was used for solid phase extraction of some toxic metal and metalloid ions. The newly designed QCPSG quantitatively sorbs As(V), Cd(II), Hg(II), and Pb(II) at the pH range 7.5–8.5 after 10 min of stirring. HCl (1 mol L???1) instantaneously elutes all the metal ions. The sorption capacity of the ion collector is 0.42, 0.46, 0.53, and 0.49 mmol g???1 for As(V), Cd(II), Hg(II), and Pb(II), respectively, whereas the preconcentration factor is 200. The effect of NaCl, Na2SO4, NaF, NaBr, Na3PO4, and other interfering salts on the sorption of metal ions (50 μg L???1) was reported. Analytical detection limits of As(V), Cd(II), Hg(II), and Pb(II) were 4.18, 2.44, 15.86, and 25.00 pg mL???1, respectively. QCPSG was used in the separation of the investigated metal ions from some natural water samples collected from diverse origins followed by determination by inductively coupled plasma–mass spectrometry. The data were compared with those obtained by the standard methods of determination using atomic absorption (hydride generation, HGAAS and after solvent extraction with ammonium pyrolidine dithiocarbamate/methyl isobutyl ketone). The suggested solid phase extraction method was found accurate with no random error.  相似文献   

14.
In this work, spectrophotometer was used as a detector for the determination of uranium from water, biological, and ore samples with a flow injection system coupled with solid phase extraction. In order to promote the online preconcentration of uranium, a minicolumn packed with XAD-4 resin impregnated with nalidixic acid was utilized. The system operation was based on U(VI) ion retention at pH 6 in the minicolumn at flow rate of 15.2 mL min?1. The uranium complex was removed from the resin by 0.1 mol dm?3 HCl at flow rate of 3.2 mL min?1 and was mixed with arsenazo III solution (0.05 % solution in 0.1 mol dm?3 HCl, 3.2 mL min?1) and driven to flow through cell of spectrophotometer where its absorbance was measured at 651 nm. The influence of chemical (pH and HCl (as eluent and reagent medium) concentration) and flow (sample and eluent flow rate and preconcentration time) parameters that could affect the performance of the system as well as the possible interferents was investigated. At the optimum conditions for 60 s preconcentration time (15.2 mL of sample volume), the method presented a detection limit of 1.1 μg L?1, a relative standard deviation (RSD) of 0.8 % at 100 μg L?1, enrichment factor of 30, and a sample throughput of 42 h?1, whereas for 300 s of the preconcentration time (76 mL of sample volume), a detection limit of 0.22 μg L?1, a RSD of 1.32 % at 10 μg L?1, enrichment factor of 150, and a sampling frequency of 11 h?1 were reported.  相似文献   

15.
A flow injection analysis method based on ion chromatography and luminol chemiluminescence detection was used for the simultaneous determination of copper (II) and cobalt (II) trace levels in soils and sediments following microwave-assisted acid digestion. Detection was based on chemiluminescence (CL) of the luminol–perborate system in an alkaline medium, which is catalyzed by both transition metals. The concentration and pH of the eluent (oxalic acid) was found to affect CL intensities and retention times, both of which were inversely proportional to the oxalic acid concentration. The calibration curves for both metal ions were linear and allowed a limit of detection of 0.003 μg l?1 for cobalt (II) and 0.014 μg l?1 for cooper (II) to be calculated. The proposed method was successfully used to determine both metal ions in certified reference materials of stream and river sediments and soil samples. Based on the results, the determination is free of interferences from the usual concomitant ions.  相似文献   

16.
A simple, rapid, and efficient dispersive liquid–liquid microextraction method, followed by UV–Vis spectrophotometry was developed for the preconcentration and determination of Pd ions in water samples. Pd ions react with α-furildioxime (chelating agent) to form a hydrophobic complex. Various parameters were altered to study and optimize their effects on the extraction efficiency, such as pH, ligand concentration, the type and volume of extraction and dispersive solvents, extraction time, and salt concentration. Under optimized conditions, the method exhibited an enrichment factor (C org/C aq) of 25 and recovery more than 98 % within a very short extraction time. The linearity of the method ranged from 10 to 200 μg?L?1. The limit of detection was 1.1 μg?L?1. The relative standard deviation for the concentration of 100 μg?L?1 of Pd was 2.3 % (n?=?10). Finally, the developed method was successfully applied to the extraction and determination of Pd in tap, river, mineral, and sea water samples.  相似文献   

17.
A novel improved preconcentration method known as rapidly synergistic cloud point extraction (RS-CPE) was established for nickel preconcentration and determination prior to its determination by flame atomic absorption spectrometry. In this work, the traditional CPE pattern was changed and greatly simplified in order to be applicable in metal extraction and detection. This method was accomplished in room temperature in 1 min. Non-ionic surfactant Triton X-114 was used as extractant. Octanol worked as cloud point revulsant and synergic reagent. The various parameters affecting the extraction and preconcentration of nickel such as sample pH, 2,2′-Furildioxime concentration, amounts of octanol, amounts of Triton X-114, type of diluting solvent, extraction time, and ionic strength were investigated and optimized. Under optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 2–200 μg L?1, and the limit of detection was 0.6 μg L?1 for nickel. The developed method was successfully applied for the determination of nickel in food and water samples. The results showed that, the proposed method can be used as a cheap, rapid, and efficient method for the extraction and preconcentration of nickel from real samples.  相似文献   

18.
We are introducing graphene oxide modified with amine groups as a new solid phase for extraction of heavy metal ions including cadmium(II), copper(II), nickel(II), zinc(II), and lead(II). Effects of pH value, flow rates, type, concentration, and volume of the eluent, breakthrough volume, and the effect of potentially interfering ions were studied. Under optimized conditions, the extraction efficiency is >97 %, the limit of detections are 0.03, 0.05, 0.2, 0.1, and 1 μg L?1 for the ions of cadmium, copper, nickel, zinc, and lead, respectively, and the adsorption capacities for these ions are 178, 142, 110, 125, and 210 mg g?1. The amino-functionalized graphene oxide was characterized by thermogravimetric analysis, transmission electron microscopy, scanning electron microscopy, and Fourier transform infrared spectrometry. The proposed method was successfully applied in the analysis of environmental water and food samples. Good spiked recoveries over the range of 95.8–100.0 % were obtained. This work not only proposes a useful method for sample preconcentration but also reveals the great potential of modified graphene as an excellent sorbent material in analytical processes.  相似文献   

19.
The application of electrical fields and chelating agents is an innovative hybrid technology used for the decontamination of soil polluted by heavy metals. The effects of four center-oriented electrical fields and chelating agents on active fractions of lead and zinc were investigated in this pot experiment. Ethylenediaminetetraacetic acid (EDTA) as a synthetic chelator and cow manure extract (CME) and poultry manure extract (PME) as natural chelators were applied to the pots (2 g kg?1) 30 days after the first irrigation. Two weeks later, four center-oriented electrical fields were applied in each pot (in three levels of 0, 10, and 30 V) for 1 h each day for 14 days. The soil near the cathode and anodes was collected and analyzed as cathodic and anodic soil, respectively. Results indicated that the soluble–exchangeable fraction of lead and zinc were decreased in the cathodic soil, while the carbonate-bound fractions were increased. In the anodic soil, however, the opposite result was observed. EDTA enhanced the soluble–exchangeable form of the metals in both anodic and cathodic soils. Furthermore, the amounts of carbonate-bound heavy metals were increased by the application of CME in both soils. The organic-bound fraction of the metals was increased by the application of natural chelators, while electrical fields had no significant impacts on this fraction.  相似文献   

20.
The present research reports on the application of modified multiwalled carbon nanotubes as a new, easily prepared, and stable solid sorbent for the column preconcentration of ultra-trace amounts of cadmium in aqueous solution. Multiwalled carbon nanotubes were oxidized with concentrated HNO3 and modified with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and then were used as a solid phase for the column preconcentration of Cd(II). Elution was carried out with 0.5 mol?L?1 HNO3. The amount of eluted Cd(II) was measured using electrothermal atomic absorption spectrometry. Various parameters such as pH, sample and eluent flow rate, eluent concentration, breakthrough volume, and interference of a great number of anions and cations on the retention of analyte on sorbent were studied. Under the optimized conditions, the calibration graph was linear in the range of 0.67 ng?L?1 to 5.0 μg?L?1 and the detection limit (3Sb, n?=?7) was 0.14 ng?L?1 in initial solution. A preconcentration factor of 300 and relative standard deviations of ±3.6 % for seven successive determinations of 3 ng of Cd(II) were achieved. The column preconcentration was successfully applied to the analysis of river water, waste water, and Persian Gulf water sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号