首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
The opacity and emission performance of two “identical” cold-side precipitators at a power plant utilizing a Western coal source was investigated through an extensive test program. The test program included establishment of outlet emission versus opacity correlations for the two “identical” units, correlation of rapper strategy (frequency and amplitude) with opacity, and correlation of power-off rapping strategy with opacity. Analysis of the test program data demonstrates that the opacity-emission correlations from the two “identical” units can be significantly different. The potential reasons for the differences between the two units are identified and examined in light of the test program data. Strong correlation of opacity with rapping strategy was developed from the test program. Results demonstrate that an automatic power-off rapping technique can significantly enhance precipitator performance on ash from Western coal.  相似文献   

2.
Use of the Deutsch equation as an evaluation tool of electrostatic precipitators has resulted in the restriction design to a single plate spacing and has not enabled optimal use of the space charge arising from the presence of charged dust particles. Space charge is dependent on dust loading and plate spacing and also influences the electric field, hence the migration velocity and, therefore, collection efficiency. Thus a trade-off is indicated between plate spacing and collection efficiency as a function of dust loading. A first step examination of this trade-off indicates that varied spacing can be used in precipitators while maintaining high levels of efficiency and decreasing the required specific collection area by 15% to 25%.  相似文献   

3.
A pilot field study was conducted with nine members of the general public to measure carbon monoxide exposure using personal monitors. The principal study objectives were to design and evaluate the research protocol and the instrumentation performance for application to the conduct of a large-scale personal monitoring program. Integrated carbon monoxide exposure was monitored and recorded according to type of activity such as “commuting” or “at work” for approximately 45 days by each subject. All subjects except one were able to handle both the equipment and data recording requirements with no significant problems. Actual data recording responsibilities consumed less than 10 min daily. The data consisted of 355 person-days each over 6-h duration, and weekdays only, from which 8-h average personal exposure levels could be computed. The 9 ppm (μL/L) ambient air quality standard was exceeded on 22 person-days. Elevated carbon monoxide concentrations during the commuting activity were frequently associated with the exceedences.  相似文献   

4.
5.
Environmental fate of and toxicity data for ammonium ethyl carbamoylphosphonate [fosamine ammonium], N-(phosphonomethyl)glycine [glyphosate], and 3-cyclohexyl-6-(dimethylamino)-1-methyl-1,3,5-triazine-2,4(1H, 3H)-dione [hexazinone] which appear promising for vegetation control in forestry are reviewed. None of the three herbicides is very persistent in soil, with half-lives reported of about 7–10 days for fosamine ammonium, 8–19 weeks for glyphosate, and 1–6 months for hexazinone, depending on soil type and climatic conditions. Degradation in soil is primarily via microbial routes. Whereas hexazinone is a very mobile herbicide (with mobility dependent on soil type), fosamine ammonium and glyphosate are strongly adsorbed and not readily leached in many soil types. Based on bioassay results, the three herbicides exhibit “very low” to “low” toxicity. Fosamine ammonium is not mutagenic and was not teratogenic when fed to pregnant rats at 10,000 ppm. Data on hexazinone indicate no carcinogenic effect in rats, negative in bacterial and mammalian point mutation assays, and not embryotoxic or teratogenic at up to 5000 ppm in diet of rats. The three herbicides have minimum-to-nil effect on soil microorganisms and exhibit little or no potential for bioaccumulation. Limitations of the available data are discussed and suggestions are made for future studies.  相似文献   

6.
Air pollution has been associated with an increased incidence of respiratory disease. However, significant differences may exist between air pollution levels measured at conventional fixed monitoring stations and actual levels inhaled by a subject. Furthermore, studies of effects of air pollution might best be done using asthmatics as study subjects, since they have irritable airways. This is a preliminary report of a study using a control and asthmatic group in which effects of air pollution are assessed by sympton and medication diaries and simple pulmonary function tests. Air pollution exposure is measured using a small portable sampler for particulates, SO2 and NO2; these samplers are carried by the subject (“personal”) and are situated inside and outside the home. Levels obtained are compared to data obtained from the same type of sampler located at a fixed monitoring station. Preliminary analysis of the data shows that the levels of pollutants are low and there are significant differences between the four air pollution measurements, with weak correlations among the various measurements. In this preliminary report, change in pulmonary function during the day correlates only with personal NO2 measurements. This suggests the need for estimating air pollution exposure using “personal” samplers, when investigating health effects.  相似文献   

7.
Results from a two-box model for calculation of tracer gas concentrations in rooms are given and consequences of different definitions of “ventilation efficiency” are discussed. Results from three different series of experiments are presented. The first two series were dilution experiments; examples of the results are given and discussed. The third series of tests was performed with one person working at a desk in the test room. Above the person;s head, a tracer gas (N2O) was injected into the convection plume, with as low momentum as possible. Starting with zero concentration, a test continued until steady-state conditions were established for the concentration levels in the different parts of the room. The tests included simulation of summer, autumn/spring, and winter daytime conditions. The results indicate a tendency towards lower tracer gas concentrations in the “breathing zone” when the supply air (typical flow rate equivalent to two air changes per hour) is brought into the room at a low level as compared to a high level close to the ceiling. The exhaust air terminal device in all tests was situated high in the “corridor” wall.  相似文献   

8.
A free-jet scrubber is an innovative gas cleaner in which the primary liquid/gas contacting takes place in the turbulent mixing zone emanating from a jet nozzle. The first such devices, powered by supersonic steam or air ejectors, were exceptionally effective cleaners but were criticized as being high-energy users. A great reduction in the energy consumption of free-jet scrubbers has been accomplished in the last four years, a feat which may seem in contradiction to the “contacting power rule.” An explanation of what is happening in these devices must take into account the effectiveness with which energy and water are utilized. thereby leading one to a somewhat circular definition of “effective contacting power.” The theoretical implication of this analysis is primarily to remind us that there are many paths between two states and some are more energy efficient than others. The practical value is that such analysis generates information which aids in choosing between several design options, a direct benefit of the various free-jet configurations.  相似文献   

9.
Methods for improving electrostatic precipitator performance by increasing electrode excitation level during rapping, and by optimizing rapping control, are presented in this paper. Design modifications can reduce mechanical impedence to vibration transmission during rapping. These same modifications can eliminate areas of high stress concentration where fatigue failure often occurs. Rapping system control parameters are presented as they relate to variations in field collection and shedding rates. Anti-coincident rapping control for plate rappers minimizes peak opacity levels during rapping if sufficient “rest times” between raps can be maintained. When anti-coincidence must be sacrificed due to insufficient rest times on large installations, suggestions for anti-coincident rapping by section are presented. Methods for optimizing field rapping repeat rates using available opacity, ash pull, and precipitator power information are discussed.  相似文献   

10.
The relationship between the odor strength of total air samples and the odor strengths of the constituents was investigated in three field experiments in an office building and a new preschool. The odor strength was scaled by magnitude estimation according to a master scale principle which results in comparable values for the total and the constituent odors. Between 60 and 120 chemical components were detected by GC/FID in the indoor air samples (N = 66). Most (81%) of the detected components in an air sample were odorous, even though most of them were of the low concentrations. By a method of pattern analysis, chemical as well as odor patterns of indoor air were found to be characteristics of different buildings. From the odor patterns (POG), the “odor print” of the outdoor air associated with the buildings was also recognized in the indoor air. Thus, the “odor print” of an air sample is different from its “chemical print”. A model was found that predicts the overall odor strength of an air sample from the number of FID-detected components most frequently reported to have a strong odor.  相似文献   

11.
The institutional and legislative framework of Swedish environmental protection is presented with special reference to the role of consultation in the policy process. The functions and duties of the National Environment Protection Board, the Franchise Board for Environment Protection, the Environment Advisory Board, and the Product Control Board are outlined. The main thrust of the 1969 Environment Protection Act, the 1972 Hazardous Products Control Act, and the environmental impact assessment requirements of the Planning and Building Legislation is presented. The character of consultation within this framework is also discussed, with reference to the role of public participation and of organized regulated interests. It is found that the main functions of consultation in policy-making are “feeding back on former policy,” “foreseeing future policies,” and “canvassing for consensus.” In the stage of policy clarification, consultation is found to be a means of “catering for compliance” and “creating coherence.” In policy implementation, consultation is an important means of gathering information from parties possibly affected by implementative decisions.  相似文献   

12.
As a guide to the possible effects of a CO2-induced warming on the cryosphere, we review the effects of three warm periods in the past, and out theoretical understanding of fluctuations in mountain glaciers, the Greenland and Antarctic ice sheets, ground ice, sea ice and seasonal snow cover. Between 1890 and 1940 A.D. the glaciated area in Switzerland was reduced by over 25%. In the Hypsithermal, at about 6000 BP, ground ice in Eurasia retreated northward by several hundred kilometres. In the interglacial Stage 5e, at about 120 000 BP, global sea-level rose by over 6 m. Fluctuations of mountain glaciers depend on mesoscale “weather” and on their mechanical response to it. Any melting of the Greenland ice sheet is likely to be slow in human terms. The West Antarctic ice sheet (its base below sea-level) is susceptible to an ungrounding, and such an event may have been the cause of the sea-level rise above. The East Antarctic ice sheet is susceptible to mechanical “surges”, which might be triggered by a warming at its margin. Both an ungrounding and a surge might occupy less than 100 yr, and are potetially the most important ice changes in human terms. Modelling studies suggest that a 5°C warming would remove the Arctic pack ice in summer, and this may be the most significant effect for further climatic change.  相似文献   

13.
This paper presents the results of a comprehensive set of analytical and experimental studies concerning the application of high intensity ionization technology to retrofit a flyash electrostatic prepitator.Described in detail are the computer-aided methods of performing functional design for ionizer-precipitator systems, selected results of ionizer-precipitator flow model tests, and the chosen physical retrofit. Also presented is the projected performance of an ionizer-precipitator system, derived from two independent design procedures which take into account the effect of space charge and gas velocity distribution on system performance.Results of these studies confirm that high intensity ionizer technology can be applied to significantly improve the collection efficiency of conventional wire-plate electrostatic precipitators.  相似文献   

14.
Dust build-up on adjacent surfaces is often an unwanted effect in industrial processes handling pulverized materials. In the case of electrostatic precipitation, build-up of dust on the collecting surface is the purpose of the process. Removal of this build-up is sometimes difficult, but necessary to maintain the continuity of the process. Dry-process methods for dust removal include rapping by impact.It is the intent of this paper to provide information on the general subject of dust removal from plates, on rapping systems used in electrostatic precipitators, and on measurements and order of magnitude of rapping forces.Rapping acceleration test results obtained in the laboratory are expanded to cover full-scale collecting surface plates.Effects of plate design, plate height and length, method of support, rapping, hammer weight, and lift are analyzed.  相似文献   

15.
The very significant impact of European legislation (Directive 91/414/EEC) on the authorization of plant protection products is reviewed herein, which has resulted in withdrawal of 704 active substances (AS) out of 889 assessed so far. The list of currently approved 276 AS includes 194 AS “existing” in the market before 1993 and 82 “new” AS introduced during the last 15 years. Results of toxicity characterization of the approved AS are also summarized, utilizing several well-known databases. Although significant data gaps exist for a rather large part of the approved AS, it is found that 84 AS are positive for at least one health effect (after chronic and/or acute exposure) including carcinogenicity, reproductive and neuro-developmental disorders, as well as endocrine disruption. The toxicity characterization results of this study are compared to those of recent assessments by other organizations (KemI, the Swedish Chemicals Agency, and the Pesticide Safety Directorate of the UK), where interpretation and use is made of AS “cut-off” criteria foreseen in new EU legislation. These studies report a comparatively smaller AS number with positive toxicity characterization. The possibility of some additional AS withdrawal in the near future, combined with the rather small rate of new AS introduction (approx. 5 per year) suggest that the list of approved AS over the next 10–15 years may not change very drastically. Consideration of the above trends is necessary and instructive in evaluating results of existing health impact assessment (HIA) studies, as well as in planning new ones. Due to the very drastic change in the number and type of marketed AS, that took place within the past 8–9 years, it is suggested that new HIA studies (based on epidemiological data after year 2000) should focus on a rather short time frame and, therefore, on appropriate cohort groups, e.g. young children. For the same reason, results of epidemiological studies of the past (involving banned AS) should be carefully interpreted and used with caution.  相似文献   

16.
In the past, most emphasis in planning for and response to an emergency situation has been placed on selected protective measures in the early phase of an emergency to keep the doses received below levels where severe deterministic health effects can be excluded and/or where the risk of stochastic effects in the population is considered “acceptable”. Less emphasis has been placed on the development of comprehensive protection strategies which include considerations of the consequences of all exposure pathways and all phases, e.g. long-term rehabilitation. In its new publication 103, ICRP proposed a coherent conceptual framework for protection in all types of exposure situations including “emergency exposure situations” and “existing exposure situations”. In the context of developing protection strategies for these exposure situations, the Commission recommends that national authorities set reference levels between, typically, 20 mSv and 100 mSv annual effective dose (emergency exposure situation) and 1 mSv and 20 mSv (existing exposure situation). In order to optimise protection strategies, it is necessary to identify the dominant exposure pathways, the timescales over which the dose will be received, and the effectiveness of available protection options. The characteristics of the development and implementation of such protection strategies is described.  相似文献   

17.
Conventional control strategies for volatile organic compounds (VOCs), a precursor to ozone, are identified. The control measures have been adopted by states in their efforts to attain the national ambient air quality standard for ozone by statutorily mandated deadlines. An inventory of viable control approaches for VOCs is presented, rather than a discussion of the approaches' comparative merits or of available alternatives. Focus is placed upon the technologies and control measures that U.S. EPA has identified as “reasonably available”, considering such criteria as effectiveness, costs, and associated energy and environmental impacts. These regulatory approaches include such strategies as vapor control in gasoline marketing, low solvent technologies and/or add-on control equipment for surface coating operations, and vehicle inspection and maintenance programs. By adopting these and additional control measures, as required, most states are projecting attainment of the ozone standard by 1987.  相似文献   

18.
Intense electric fields up to 107 V/m generate very interesting and useful applications for the environment. Several processes using high electrical voltage for environment preservation were developed in the laboratory. The purpose of this study was to review these applications, highlighting their economic and environmental benefits: (1) electrostatic separators of particles used in industrial wastes recycling; (a) role-type electrostatic separator for granular mixtures of plastic–metal particles; (b) free-fall and rotating belt triboelectric separators for mixtures of plastic–plastic particles; (c) plate-type electrostatic separator for mixtures of metal–metal particles, (2) electrostatic precipitators for gas cleaning and (3) ozone generators for air and water treatment.  相似文献   

19.
Significant effort has been devoted by past researchers in electrostatic precipitators to electrostatics and particle chemistry. Relatively little, however, has been published on the effect of turbulent flow and its interaction with electrostatics and particle dynamics. This paper describes an experiment and a fundamental model which is focused on the coupled effects of the fluid dynamics and electrostatics.A laboratory precipitator flow facility with laser beam illumination was used to visualize smoke flow. Detailed photographs of flow patterns with and without electric field were recorded in a horizontal plane through the precipitator.A theoretical model was used to numerically simulate the observed flow patterns in the experiment. In the model the flow was described by time-averaged mass and momentum equations with a two-equation turbulence model. The electric field was described by Maxwell electrostatic equation and the continuity of the current equation. The system of the coupled partial differential equations was solved by a finite difference scheme.The interaction between fluid dynamics and electrostatics is shown to have a significant role in altering the flow in the precipitator. The practical implication is that the interaction will aid in particle migration in some regions, but it will increase reentrainment and reduce particle migration in others. Comparison between the results from the experiment and numerical computations shows good qualitative agreement between the two. Since both the electrostatic and the fluid dynamic flow fields depend on the electrode geometry, further investigation may lead to improved design of precipitators.  相似文献   

20.
A complete assessment of the health effects of diesel emissions must take into account the possible chemical transformations (and associated biological impacts) of particulate organic matter (POM) due to reactions with the many gaseous copollutants which have now been unambiguously demonstrated to be present in atmospheres burdened by photochemical air pollution. These copollutants include the “trace” species, nitric (HNO3) and nitrous (HONO) acids, the nitrate radical (NO3), formaldehyde (H2CO) and formic acid (HCOOH), as well as the criteria pollutants, ozone (O3) and nitrogen dioxide (NO2). Techniques for establishing the atmospheric concentrations of the trace pollutants (and their spatial and temporal variations) are briefly described, and we present results of investigations into the reactions of polycyclic aromatic hydrocarbons (PAH) coated on filters and exposed to ambient concentrations of O3 and NO2. Environmental health implications of these results are discussed and include the potential for sampling “artifacts” and their possible effects on the correlation (or lack thereof) between ambient PAH levels and urban lung cancer rates, as well as the problems associated with understanding the appropriate POM “dose” to be employed in animal testing and assessments of impacts on human health.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号