首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A cellulose acetate membrane, positioned in a passive sampler system, was coated with the perfluorinated polymer Nafion. Aqueous metal transport through the membrane and the Nafion film was investigated. The Nafion-coated membrane prevents the transport of metals bound to natural organic material to the receiving phase in the passive sampler, while copper associated with small synthetic ligands pass through the Nafion film. Increasing thickness of the Nafion film decreases the metal uptake rate to the receiving phase in the passive sampler and increases the response time. A decreased response time for the passive sampler would provide a better estimation of rapid changes in concentration, particularly for dynamic aquatic systems such as urban runoff. Limited biofouling protection with the Nafion coating was demonstrated by growth inhibition of natural periphyton communities on glass surfaces.  相似文献   

2.
The development of convenient and competitive devices and methods for monitoring of organic pollutants in the aquatic environment is of increasing interest. An integrative passive sampling system has been developed which consists of a solid poly(dimethylsiloxane) (PDMS) material (tube or rod), acting as hydrophobic organic receiving phase, enclosed in a water-filled or an air-filled low-density polyethylene (LDPE) membrane tubing. These samplers enable the direct analysis of the pollutants accumulated during exposure in the receiving phase by thermodesorption-GC/MS, avoiding expensive sample preparation and cleanups. The capabilities of these sampling devices were studied for the sampling of 20 persistent organic pollutants (chlorobenzenes, hexachlorocyclohexanes, p,p'-DDE, PAHs, and PCBs) in laboratory exposure experiments. For the three sampler designs investigated the uptake of all target analytes was integrative over exposure periods up to 9 days (except PCB 101). The determined sampling rates range from 4 to 1340 microl h(-1) for the water-filled samplers and from 20 to 6360 microl h(-1) for the air-filled ones, respectively. The sampling rate of the analytes is dependent on their molecular weight, partition between water and sampler media (PDMS, polyethylene, water, air) and also of the sampler design. The passive samplers enable the estimation of time-weighted average (TWA) concentration of water pollutants in the lower ng l(-1) to pg l(-1) range.  相似文献   

3.
The performance of an integrative passive sampler that consists of a C18 Empore disk sorbent receiving phase fitted with low density polyethylene membrane was optimised for the measurement of time-weighted average concentrations of hydrophobic micropollutants in water. A substantial improvement of sampling characteristics including the rate of sampling and the sampling precision was achieved by decreasing the internal sampler resistance to mass transfer of hydrophobic organic chemicals. This was achieved by adding a small volume of n-octanol, a solvent with high permeability (solubility [times] diffusivity) for target analytes, to the interstial space between the receiving sorbent phase and the polyethylene diffusion-limiting membrane.  相似文献   

4.
半透膜采样技术是一种可原位、连续、动态监测水环境中非极性、弱极性有机污染物的被动采样技术,已在国内外发展20余年,但在环境监测中使用很少。从半透膜被动采样特点、采样器构造入手,着重对应用该技术的环节进行剖析,同时涉及被动采样结果及其评价方法。最后以多环芳烃(PAHs)为例,综述了近年来SPMD技术监控水体中非极性、弱极性有机污染物的常用分析技术及其发展。  相似文献   

5.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

6.
Silicone rubber sheeting can be used as a passive sampling device for hydrophobic organic contaminants in the environment to determine the available concentrations in water and sediments. Reliable sampler-water partition coefficients are required to determine the sampling rates and the dissolved contaminant concentrations in water and in sediment pore water. Log partition coefficients (logK(sr,w)) for silicone rubber-water have been estimated for 32 polycyclic aromatic hydrocarbons (PAHs), 2 deuterated PAH analogues and 32 chlorobiphenyls (CBs) using the cosolvent method, with methanol as cosolvent. Strong linear relationships were found with literature values for the corresponding log octanol-water partition coefficients (logK(ow)) for both CBs and PAHs, confirming that partitioning into the silicone rubber is strongly determined by the hydrophobicity of the compounds, which suggests logK(ow) is a good predictor of logK(sr,w) and that absorption is the main mechanism for accumulation of analytes into the silicone rubber polymer.  相似文献   

7.
A thin-walled silicone rubber hollow fibre membrane has been developed as a passive sampler. The inside of the tube is filled with an aqueous solution at an appropriate pH. The tube is sealed at both ends and then immersed in a water sample. In order for the ionizable permeating compounds to be trapped in the aqueous receiving phase, the pH is adjusted such that the compounds are ionized and trapped. The major advantages are its simplicity, low cost and high selectivity, since only ionizable organic compounds are trapped. Additionally, the sampler uses no organic solvent. By adjusting the pH of the acceptor phase, it is possible to control the extraction process and whether the sampler is used in the kinetic or equilibrium regime. Since it is very selective, no further clean-up of the extract is required. The membrane assisted passive sampler has been tested for extraction of chlorophenols under laboratory conditions. The extraction process was found to be linear over a 72 h sampling period. Selectivity of the passive sampler in river water was demonstrated and the extraction process was independent of sample concentration, even at lower concentration levels of analytes. However, the sample matrix in some river water samples led to incomplete trapping, thereby reducing the amount trapped in the acceptor phase. Detection limits (three times signal to noise ratio) were dependant on sample matrix and type of detection system and ranged from 0.05 microg L(-1) to about 1 microg L(-1) with a UV photodiode detector in water samples from one river and 1.0 microg L(-1) to 20 microg L(-1) in another but with an ordinary UV detector. The enrichment factors in river water were 28 for 2-chlorophenol and 44 for 2,4-dichlorophenol over a 72 h sampling period. 4-chlorophenol was poorly extracted and its enrichment factor was 3.  相似文献   

8.
Lipid-filled semipermeable membrane devices (SPMDs) are receiving increasing attention as passive, in situ samplers for the assessment of environmental pollutant exposure. Although SPMDs have been successfully used in a variety of field studies in surface waters, only a few studies have addressed their characteristics as groundwater samplers. In this study, the performance of the SPMDs for monitoring organic contaminants in groundwater was evaluated in a pilot field application in an area severely contaminated by chemical waste, especially by chlorinated hydrocarbons. The spatial distribution of hydrophobic groundwater contaminants was assessed using a combination of passive sampling with SPMDs and non-target semiquantitative GC-MS analysis. More than 100 contaminants were identified and semiquantitatively determined in SPMD samples. Along the 6 field sites under investigation, a large concentration gradient was observed, which confirms a very limited mobility of hydrophobic substances in dissolved form in the aquifer. The in situ extraction potential of the SPMD is limited by groundwater flow, when the exchange volume of well water during an exposure is lower than the SPMD clearance volume for the analytes. This study demonstrates that SPMDs present a useful tool for sampling and analyzing of groundwater polluted with complex mixtures of hydrophobic chemicals and provides guidance for further development of passive sampling technology for groundwater.  相似文献   

9.
总结了半透膜被动采样器(SPMDs)、极性有机化合物整合采样器(POCIS)、化学捕收器(Chemcatcher)和硅橡胶被动采样器(Silicon rubber)几种常用被动采样器的结构组成、应用模型、原理、样品的前处理、影响因素及应用范围,指出几种被动采样技术应用上存在的问题,并对其应用前景进行总结和展望。  相似文献   

10.
Effluent from sewage treatment plants has been associated with a range of pollutant effects. Depending on the influent composition and treatment processes the effluent may contain a myriad of different chemicals which makes monitoring very complex. In this study we aimed to monitor relatively polar organic pollutant mixtures using a combination of passive sampling techniques and a set of biochemistry based assays covering acute bacterial toxicity (Microtox), phytotoxicity (Max-I-PAM assay) and genotoxicity (umuC assay). The study showed that all of the assays were able to detect effects in the samples and allowed a comparison of the two plants as well as a comparison between the two sampling periods. Distinct improvements in water quality were observed in one of the plants as result of an upgrade to a UV disinfection system, which improved from 24x sample enrichment required to induce a 50% response in the Microtox assay to 84x, from 30x sample enrichment to induce a 50% reduction in photosynthetic yield to 125x, and the genotoxicity observed in the first sampling period was eliminated. Thus we propose that biochemical assay techniques in combination with time integrated passive sampling can substantially contribute to the monitoring of polar organic toxicants in STP effluents.  相似文献   

11.
Fused-silica-lined (FSL) canisters and SUMMA polished (SUMMA) canisters were compared for the recoveries and the stabilities of 58 volatile organic compounds (VOCs) at low ppbv (volume/volume) levels under various humidified conditions using a three-stage preconcentration method followed by GC-MS analysis. The target VOCs included non-polar VOCs (e.g. halogenated hydrocarbons and aromatic hydrocarbons) and polar VOCs (e.g. alcohols, ketones, esters, ethers, nitriles and thiols). The three-stage preconcentration method was initially optimized for simultaneous analysis of non-polar and polar VOCs because determination of canister stability is dependent on the accuracy of analytical measurements. The method showed good linearity over the concentration range from 1 to 25 ppbv for all target analytes, and the correlation coefficients were higher than 0.9974. The method detection limits ranged from 0.023 to 0.39 ppbv. The test mixtures loaded in both type of canisters (n = 3) had concentrations of 1.7-2.5 ppbv per compound at ambient pressure under various humidified conditions (%RH = 1.6, 8.0, 27, 39, 53 and >99% with excess water present). All canister samples were initially analyzed on day 0 (after 6-12 h). The effect of competitive adsorption of water vapor and polar VOCs on active sites of interior surface was remarkably observed for SUMMA canisters. Polar VOCs had a greater requirement for water vapor to be present. The RH percentages that ensured good recovery on day 0 were RH > 8% for non-polar VOCs and RH > 27% for polar VOCs (except alcohols under the condition of RH > 99%). All thiols were not recovered from SUMMA canisters under all conditions. FSL canisters showed good recoveries of more than 86% for all VOCs under all conditions on day 0 (except alcohols under the condition of RH > 99%). The recoveries of alcohols in both canisters under the condition of RH > 99% displayed relatively low recoveries in the range 25-76% because of the partitioning effect into condensed water. The canister samples under the conditions of RH 8.0, 27, 53 and > 99% were analyzed for the stability test on days 3, 7, 14 and 28 after loading. All non-polar VOCs were reasonably stable in the FSL canisters under all examined conditions over 28 days. However, several polar VOCs that have relatively lower vapor pressure, e.g. MIBK, butyl acetate and alcohols except ethanol, showed unstable characteristics under relatively dry conditions (RH 8 and 27%) during 28 days. RH > 53% was needed to ensure good stabilities of all analytes except thiols with the recoveries of > 80% over 28 days for both canisters. Although the FSL canister showed good recoveries of more than 86% for thiols on day 0, drastic degradations were observed after day 3 and they were not detected after day 14.  相似文献   

12.
In the present work we have developed an analytical methodology for the determination of nonylphenol (NP) and nonylphenol mono- and di-ethoxylates (NP1EO and NP2EO) in water samples. The applicability of this methodology was proved by means of the analysis of environmentally relevant aqueous samples from Buenos Aires. This constitutes a starting point for a rigorous assessment of the incidence of NPnEO surfactants in Argentina, as only very few, qualitative or semi-quantitative data on the occurrence of these compounds in local systems were available up to this time. Enrichment of the analytes was carried out by solid-phase extraction on a C-18 sorbent, followed by elution with ethyl acetate. Normal-phase high performance liquid chromatography on an amino-silica column and fluorescence detection at excitation-emission wavelengths of 230-300 nm were employed for separation and quantification of the analytes. Confirmation of peak assignment in selected real samples was performed by off-line coupling HPLC with GC-MS analysis. A non-polar GC capillary column was used, and a characteristic peak pattern was obtained for the alkyl chain isomers of each ethoxylated homologue and NP. GC-MS analyses yielded in all cases purity levels higher than 80% for the HPLC collected fractions. The elevated concentrations found for the estrogenic metabolites of NPnEO are in accordance with an unrestricted use of this class of non-ionic surfactants in the country.  相似文献   

13.
天然水体中的痕量持久性有机污染物(POPs)的定量分析通常需要采集大体积水样.针对大体积水样在过滤和吸附富集过程中滤膜易堵塞且耗时费力的缺点,研制了一种固液分离过滤-吸附富集联动装置.该装置主要由粗过滤器、离心分离屏、倒置微孔过滤器、固相吸附柱、流速控制阀和真空泵组成.与传统的滤膜过滤方式相比,其过滤效率提高了约1.5...  相似文献   

14.
我国水环境有机物分析前处理技术   总被引:1,自引:0,他引:1  
介绍了我国水环境有机物分析中常用的前处理技术,包括液液萃取、树脂吸附、固相萃取、固相微萃取、液膜萃取、半透膜被动采样、顶空、吹扫-捕集等,归纳了各种方法的原理、应用及优缺点,并对环境中有机污染物前处理技术的发展方向进行了展望。  相似文献   

15.
There is an increasing need to monitor concentrations of polar organic contaminants in the aquatic environment. Integrative passive samplers can be used to assess time weighted average aqueous concentrations, provided calibration data are available and sampling rates are known. The sampling rate depends on environmental factors, such as temperature and water flow rate. Here we introduce an apparatus to investigate the sampling properties of passive samplers using river-like flow conditions and ambient environmental matrices: river water and treated sewage effluent. As a model sampler we selected Empore SDB-RPS disks in a Chemcatcher housing. The disks were exposed for 1 to 8 days at flow rates between 0.03 and 0.4 m s(-1). Samples were analysed using a bioassay for estrogenic activity and by LC-MS-MS target analysis of the pharmaceuticals sulfamethoxazole, carbamazepine and clarithromycin. In order to assess sampling rates of SDB disks, we also measured aqueous concentrations of the pharmaceuticals. Sampling rates increased with increasing flow rate and this relationship was not affected by the environmental matrix. However, SDB disks were only sampling in the integrative mode at low flow rates <0.1 m s(-1) and/or for short sampling times. The duration of linear uptake was particularly short for sulfamethoxazole (1 day) and longer for clarithromycin (5 days). At 0.03 m s(-1) and 12-14 degrees C, the sampling rate of SDB disks was 0.09 L day(-1) for clarithromycin, 0.14 L day(-1) for sulfamethoxazole and 0.25 L day(-1) for carbamazepine. The results show that under controlled conditions, SDB disks can be effectively used as passive sampling devices.  相似文献   

16.
基于葫芦脲的超分子特性,以醋酸纤维素为载体,制备了葫芦脲膜,采用傅里叶红外光谱、扫描电镜、热重分析对膜的性能进行了表征,研究了葫芦脲膜对三氯生(TCS)和三氯卡班(TCC)的吸附性能,验证了以葫芦脲膜为结合相的被动采样技术测定2种物质的可行性。结果表明:葫芦脲分子确实被引入到醋酸纤维素中,相比于醋酸纤维素膜,葫芦脲膜具有更强的热稳定性和吸附性能;以葫芦脲膜为结合相的被动采样装置在不同环境因素(pH值、离子强度、可溶性有机质)下都具有良好的工作稳定性;将该装置布设到南京市秦淮河中的2个采样点,野外实验验证了该采样装置应用于监测实际水体中的TCS和TCC的可行性。  相似文献   

17.
Continuous, intermittent and passive sampling of airborne VOCs   总被引:1,自引:0,他引:1  
Long sampling periods are often advantageous or required for measuring air quality and characterizing exposures. However, sampling periods exceeding 8 to 24 h using thermally desorbable adsorbent tube (TDT) samplers for the measurement of airborne volatile organic compounds (VOCs) face several challenges, including maintaining stable and low flow rates, and avoiding breakthrough of the adsorbent. These problems may be avoided using intermittent sampling; however, the literature contains few if any reports that have evaluated this technique in environmental, occupational or other applications. The purpose of this study is to evaluate continuous, intermittent and passive sampling methods using both laboratory and real-world tests. Laboratory tests compared continuous and intermittent (active) samplers in a controlled dynamic test gas generation system. Field tests used side-by-side active and passive samplers in an office, home workshop and four smokers' homes. All samples were analyzed for a wide range of VOCs by GC-MS. In most instances, intermittent sampling yielded better reproducibility (duplicate precision of 10 +/- 6%) than continuous low-flow sampling (18 +/- 5%), in part due to difficulty maintaining low flows. Concentrations obtained using intermittent sampling agreed with those for continuous sampling, with downward biases resulting primarily from errors in flow rate measurements. In the field, more VOC species were detected using active rather than passive sampling. Passive measurements were 12% lower than continuous measurements, a difference attributed to declining uptake rates at higher concentrations over the 3 to 4 d sampling period. Overall, most measurements obtained using the three sampling methods agreed within 20% for a wide range of concentrations (0.1 to 230 microg m(-3)). Both passive and intermittent sampling approaches are suitable for long sampling periods, but intermittent sampling provides greater flexibility with respect to sampling period, and permits the use of multi-bed adsorbents that can capture a wider range of VOCs.  相似文献   

18.
Pollution studies of air and water samples have been greatly enhanced by the use of chromatographic techniques. The selection of the proper detectors coupled with the various column types and substrates have broadened the capabilities of environmental analyses. Proper care in sampling protocols and sample treatment has steadily improved the sensitivity of these measurements. The recommended methods for air, wastewater, drinking water and solid waste samples all utilize some type of chromatographic analysis for the determination of organic contaminants. Three complimentary techniques: i.e., headspace sampling (dynamic and static methods), microextractions (liquid-liquid and/or liquid-solid) and solid-phase extractions have expanded the capabilities of such studies to permit the analytical chemist to perform fast in-the-field monitoring, concentrate low levels of analytes and determine solubilities of toxic substances. A discussion of other environmental areas which should be studied, along with the changes and/or modifications in analytical technology which should be investigated, will be presented.Plenary speaker.  相似文献   

19.
In this study, the semipermeable membrane device (SPMD) passive samplers were used to determine freely dissolved concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in selected water bodies situated in and around Johannesburg City, South Africa. The devices were deployed for 14 days at each sampling site in spring and summer of 2011. Time weighted average (TWA) concentrations of the water-borne contaminants were calculated from the amounts of analytes accumulated in the passive samplers. In the area of interest, concentrations of analytes in water ranged from 33.5 to 126.8 ng l?1 for PAHs, from 20.9 to 120.9 pg l?1 for PCBs and from 0.2 to 36.9 ng l?1 for OCPs. Chlorinated pesticides were mainly composed of hexachlorocyclohexanes (HCHs) (0.15–36.9 ng l?1) and dichlorodiphenyltrichloromethane (DDT) with its metabolites (0.03–0.55 ng l?1). By applying diagnostic ratios of certain PAHs, identification of possible sources of the contaminants in the various sampling sites was performed. These ratios were generally inclined towards pyrogenic sources of pollution by PAHs in all study sites except in the Centurion River (CR), Centurion Lake (CL) and Airport River (AUP) that indicated petrogenic origins. This study highlights further need to map up the temporal and spatial variations of these POPs using passive samplers.  相似文献   

20.
While air sampling techniques using adsorbent-based collection, thermal desorption and chromatographic analysis have found a niche in ambient air sampling, occupational applications have been more limited. This paper evaluates the use of thermal desorption techniques for low flow active and passive sampling configurations which allow conveniently long duration sampling in occupational settings and other high concentration environments. The use of an orifice enables flows as low as 0.5 ml min(-1) and sampling periods up to several days without significant biases. A model is used to predict sampling rates of a passive sampler encompassing an orifice, a void space, glass wool, and the adsorbent. Laboratory and field tests conducted at a commercial offset printing facility, which contained a variety of volatile organic compounds (primarily aromatic but also a few chlorinated and terpene compounds at levels from 1 to 67,000 microg m(-3)), are used to evaluate the approach. Tenax GR and Carbosieve SIII, both singly and together, were employed as adsorbents. Side-by-side tests comparing high flow, low flow and passive samplers show excellent agreement and high linearity (r = 0.95) for concentrations spanning nearly five orders of magnitude. Active samplers were tested at flows as low as 0.5 ml min(-1), compared to typical flows up to 40 ml min(-1). Passive samplers demonstrated a linear range and agreement with predictions for adsorbate loadings from approximately 1 ng to nearly 10 microg. Using a chemical mass balance receptor model, concentrations in the facility were apportioned to solvents, inks and other indoor and outdoor sources. Overall, the use of low flow active and passive sampling approaches employing thermal desorption techniques provides good performance and tremendous flexibility that facilitates use in many applications, including workplace settings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号