首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
A tracer study was initiated in November 1993 to investigate depression-focused recharge and to monitor solute movement through the vadose zone into the shallow ground water in southeastern North Dakota. Granular potassium chloride (KCl) was surface-applied to two areas overlying subsurface drains and to one area instrumented with soil solution samplers, ground water monitoring wells, time domain reflectometry (TDR) probes, and temperature probes. One of the subsurface drain tracer plots was located on level ground while the other two sites were in small topographic depressions. Formation of ground water mounds beneath the depressions indicated that these areas are recharge sites. The applied Cl- tracer was found to move rapidly to the shallow ground water under the depressional areas after infiltration of spring snowmelt in 1994. Excessive rainfall events were also responsible for focused recharge and the rapid transport of the applied Cl- tracer. Water flow through partially frozen soil at the bottom of the depressions during thaw enhanced preferential movement of the tracer.  相似文献   

2.
ABSTRACT: Ground water samples were collected from 30 wells located in, or directly down gradient from, recharge areas of the Eutaw aquifer in Montgomery, Alabama. The major ion content of the water evolves from calcium‐sodium‐chloride‐dominated type in the recharge area to calcium‐bicarbonate‐dominated type in the confined portion of the aquifer. Ground water in the recharge area was under saturated with respect to aluminosilicate and carbonate minerals. Ground water in the confined portion of the aquifer was at equilibrium levels for calcite and potassium feldspar. Dissolved oxygen and nitrite‐plus‐nitrate concentrations decreased as ground water age increased; pH, iron, and sulfate concentrations increased as ground water age increased. Aluminum, copper, and zinc concentrations decreased as ground water age and pH increased. These relations indicate that nitrate, aluminum, copper, and zinc are removed from solution as water moves from recharge areas to the confined areas of the Eutaw aquifer. The natural evolution of ground water quality, which typically increases the pH and decreases the dissolved oxygen content, may be an important limiting factor to the migration of nitrogen based compounds and metals.  相似文献   

3.
ABSTRACT: Numerical models were used to examine the limitations of the assumptions used in an analytical induced infiltration model. The assumptions tested included negligible streambed effects, negligible areal recharge, two-dimensional ground water flow, fully penetrating rivers and wells, and constant surface water stage. For situations that deviate from the underlying assumptions, the analytical model becomes a less reliable predictor of induced infiltration. The numerical experiments show that streambed effects cannot be neglected if the streambed conductivity is more than one order of magnitude lower than the aquifer hydraulic conductivity. Areal recharge cannot be neglected if the ground water basin receives more than 5 in/yr of areal recharge. Three-dimensional flow effects due to well partial penetration cannot be neglected if the ratio of horizontal hydraulic conductivity to vertical hydraulic conductivity (Kh/Ku) is greater than 10. Surface water elevation fluctuations can significantly influence the induced infiltration rate, depending on the degree of fluctuations and the ground water hydraulic gradient.  相似文献   

4.
ABSTRACT: The Hanging Gardens are a unique feature of Zion National Park. Knowledge of the source and residence time of water discharging from the Hanging Gardens is necessary to help preserve these features. Ground-water chemical and isotopic data distinguish the discharge from seeps and springs into two groups, one of low and one of high conductivity. Water with low conductivity likely originates as recharge near the seeps and springs, and it only interacts with the Navajo Sandstone. High conductivity water, on the other hand, originates as recharge on the tops of plateaus to the east, where it interacts with marine rocks of the Carmel Formation. Carbon dating of these ground waters indicates that the low conductivity water is essentially modern recharge, while the high conductivity water was recharged 1,000 to 4,000 years ago.  相似文献   

5.
ABSTRACT: Two water‐quality studies were done on the outskirts of the Detroit metropolitan area to determine how recent residential development has affected ground‐water quality. Pairs of monitor and domestic wells were sampled in areas where residential land use overlies glacial outwash deposits. Young, shallow waters had significantly higher median concentrations of nitrate, chloride, and dissolved solids than older, deeper waters. Analysis of chloride/bromide ratios indicates that elevated salinities are due to human activities rather than natural factors, such as upward migration of brine. Trace concentrations of volatile organic compounds were detected in samples from 97 percent of the monitor wells. Pesticides were detected infrequently even though they are routinely applied to lawns and roadways in the study area. The greatest influence on ground‐water quality appears to be from septic‐system effluent (domestic sewage, household solvents, water‐softener backwash) and infiltration of storm‐water runoff from paved surfaces (road salt, fuel residue). No health‐related drinking‐water standards were exceeded in samples from domestic wells. However, the effects of human activities are apparent in 76 percent of young waters, and at depths far below 25 feet, which is the current minimum well‐depth requirement.  相似文献   

6.
ABSTRACT: Interpretation of ground water level changes in a developed aquifer usually relies on reference to some benchmark such as “predevelopment” ground water levels, changes from fall to fall and/or spring to spring, or to determination of maximum stress during the pumping season. The assumption is that ground water levels measured in the monitoring well accurately reflect the state of the ground water resource in terms of quantity in storage and the effects of local pumping. This assumption is questionable based on the patterns shown in continuous hydrographs of water levels in monitoring wells in Nebraska, and wells installed to determine vertical gradients. These hydrographs show clear evidence for vertical ground water gradients and recharge from overlying parts of the aquifer system to deeper zones in which production wells are screened. The classical concept of semi‐perched ground water, as described by Meinzer, is demonstrated by these hydrographs. The presence of semi‐perched ground water (Meinzer definition, there is no intervening unsaturated zone) invalidates the use of measured ground water levels in regional observation programs for detailed numerical management of the resource. Failure to recognize the Meinzer effect has led to faulty management. The best use of data from the observation well network would be for detection of trends and education unless it is clearly understood what is being measured.  相似文献   

7.
ABSTRACT: This study estimates subsurface return flow and effective ground water recharge in terraced fields in northern Taiwan. Specifically, a three dimensional model, FEMWATER, was applied to simulate percolation and lateral seepage in the terraced fields under various conditions. In the terraced paddy fields, percolation mainly moves vertically downward in the central area, while lateral seepage is mainly focused around the bund. Although the simulated lateral seepage rate through the bund exceeded the percolation rate in the central area of the paddy field, annual subsurface return flow at Pei‐Chi and Shin‐Men was 0.17 × 106 m3 and 0.37 × 106 m3, representing only 0.17 percent and 0.21 percent of the total irrigation water required for rice growth at Pei‐Chi and Shin‐Men, respectively. For upland fields, the effective ground water recharge rate during the second crop period (July to November) exceeded that during the first crop period (January to May) because of the wet season in the second crop period. Terraced paddy fields have the most efficient ground water recharge, with 21.2 to 23.4 percent of irrigation water recharging to ground water, whereas upland fields with a plow layer have the least efficient ground water recharge, with only 4.8 to 6.6 percent of irrigation water recharging to ground water. The simulation results clearly revealed that a substantial amount of irrigation water recharges to ground water in the terraced paddy, while only a small amount of subsurface return flow seeps from the upstream to the downstream terraced paddy. The amounts of subsurface flow and ground water recharge determined in the study are useful for the irrigation water planning and management and provide a scientific basis to reevaluate water resources management in the terrace region under irrigated rice.  相似文献   

8.
ABSTRACT: Many water wells developed in the Middle Mississippian Greenbrier Group of central Greenbrier County, West Virginia, are very productive because of the abundant solution conduits in this karst aquifer. Water from these wells, all of which (with one exception) are clustered in a small area about eight kilometers northwest of Lewisburg, West Virginia, is typically very hard (calcium-magnesium-bicarbonate type). Of 74 wells sampled, eight showed sulfate concentrations ranging from 600 to 1700 mg/l. These wells also showed a much higher than average concentration of calcium, magnesium, chloride, sodium, and, in a few cases, iron. The water from several of these wells was not potable. Previously unpublished work has suggested that dolomite and gypsum dissolution have contributed magnesium and sulfate ions to the ground water. It is also likely that, where sodium, chloride, and iron concentrations are above background, halite dissolution and pyrite oxidation are contributing to the problem. All of these minerals are often associated with the basal waterbearing strata of the Greenbrier Group. In addition, it is possible that the wells are receiving deeply circulating ground waters, via fracture zones, which feed many other well-known sulfur and/or thermal springs in the central Appalachians.  相似文献   

9.
ABSTRACT: Ground water nitrate contamination and water level decline are common concern in Nebraska. Effects of artificial recharge on ground water quality and aquifer storage recovery (ASR) were studied with spreading basins constructed in the highly agricultural region of the Central Platte, Nebraska. A total of 1.10 million m3 of Platte River water recharged the aquifer through 5000 m2 of the recharge basins during 1992, 1993, and 1994. This is equivalent to the quantity needed to completely displace the ground water beneath 34 ha of the local primary aquifer with 13 m thickness and 0.25 porosity. Successful NO3-N remediation was documented beneath and downgradient of the recharge basins, where NO3-N declined from 20 to 2 mg L-1. Ground water atrazine concentrations at the site decreased from 2 to 0.2 mg L-1 due to recharge. Both NO3-N and atrazine contamination dramatically improved from concentrations exceeding the maximum contaminant levels to those of drinking water quality. The water table at the site rose rapidly in response to recharge during the early stage then leveled off as infiltration rates declined. At the end of the 1992 recharge season, the water table 12 m downgradient from the basins was elevated 1.36 m above the preproject level; however, at the end of the 1993 recharge season, any increase in the water table from artificial recharge was masked by extremely slow infiltration rates and heavy recharge from precipitation from the wettest growing season in over 100 years. The water table rose 1.37 m during the 1994 recharge season. Resultant ground water quality and ASR improvement from the artificial recharge were measured at 1000 m downgradient and 600 m upgradient from the recharge basins. Constant infiltration rates were not sustained in any of the three years, and rates always decreased with time presumably because of clogging. Scraping the basin floor increased infiltration rates. Using a pulsed recharge to create dry and wet cycles and maintaining low standing water heads in the basins appeared to reduce microbial growth, and therefore enhanced infiltration.  相似文献   

10.
ABSTRACT: The Kansas-Nebraska Big Blue River compact requires that the state of Nebraska insure a minimum flow of the Big Blue River across the state line. There are two options that the state of Nebraska may use to ensure minimum flows. The obvious option is to limit surface-water irrigators along the river. However, under the terms of the compact, a second option may be to regulate irrigation wells that are within one mile of the river and were installed after November 1, 1968. The objective of this study is to quantify the effects of 17 irrigation wells that may be regulated on baseflow of the Big Blue River. A finite-element model is used to study the hydrogeologic system between DeWitt and Beatrice, Nebraska. The 17 wells that may be regulated are located between these towns and are developed in sediments deposited in a cross-cutting paleovalley anchor alluvium associated with the Big Blue River. While there wore considerable existing data, additional data were gathered by drilling an additional nine test holes, conducting several aquifer tests, stream-stage measurements, and baseflow calculation through extensive stream-discharge measurements, establishment of a ground water-level monitoring network, determining the amount of water pumped for irrigation and municipal use in the area, and a short-term precipitation network. The model was calibrated using observed baseflow and ground water level data. The model clearly shows that regulating the 17 wells to maintain baseflow would have a minimal effect on the overall water budget. This is reasonable, especially considering that there are over 250 irrigation wells in the project area. The 17 wells considered pumped only 6 percent of the total pumpage within the modeled area during the irrigation season of 1984. The computer model provides the documentation needed to demonstrate this fact. Although much of the resources spent and a significant amount of hydrogeologic data are being collected over a period of three years on a relatively small area, the simulation model could be improved through further field testing of the aquifer and stream-bed sediment characteristics and quantification of ground water recharge, discharge, and evapotranspiration rates.  相似文献   

11.
ABSTRACT: Local governmental agencies responsible for decisions in ground water quality management need not only data on ground water quality but they also must understand the relationship of accuracies and risks associated with this data as related to the number of wells to sample. In this report we address this problem by using the philosophical doctrines of probabilism and relativism with simple statistical procedures. This requires a reasonable estimate of the population variance in a quality parameter for a given management-unit area, and requires that the decisionmaker formulate constraints with an acceptable standard error of the sample mean and be willing to accept some level of probability of being Wrong. This technique is illustrated using a 21-year data base of well water chemical data in a 653 km2 ground water quality study area in the San Joaquin Valley of California.  相似文献   

12.
ABSTRACT: The use of artificial recharge in Saskatchewan and the rest of Canada to improve rural community and farmstead domestic water supply has great potential. Approximately 75 percent of the people in rural Saskatchewan and 26 percent of all the people in Canada are dependent on ground water for their domestic water supply. Typically, this water is highly mineralized and is often unpalatable due to odor and taste. A source of readily available, high quality water to eliminate expensive chemical treatment of available water and long distance hauling would be of significant value to rural residents. Storage of high quality water in aquifers by injection through wells has been documented and has been shown to depend on the use of a surface water catchment system to provide the high quality water. Since air entrainment or formation clogging can occur in poorly operated recharge schemes, development of proper design and operation of recharging procedure is required. This can be accomplished by using an injection response computer model and a properly designed injection system. Small scale artificial recharge projects will provide a valuable commodity to rural water users and will promote sustainable and conjunctive use of surface and ground water resources.  相似文献   

13.
ABSTRACT: Water balance modeling and the analysis of stable water isotopes in ground water were conducted to aid the location of ground water discharge areas within the Goose River basin, in mid‐coastal Maine. Previous investigations of drinking water from wells in the fractured crystalline bedrock encountered persistent elevated total arsenic. Such contamination may be related to discharging ground water from fractured zones in the basin. Modeled discharge rates greater than +10 cm/yr and 18O values lighter than‐9.5 per mil VSMOW may indicate recent recharge is mixing with deeper ground water and is focused along some fractured zones in arsenic bearing crystalline rocks.  相似文献   

14.
ABSTRACT: Cedar Rapids obtains its municipal water supply from a shallow alluvial aquifer along the Cedar River in east-central Iowa. Water samples were collected and analyzed for selected isotopes and chlorofluorocarbons to characterize the ground-water flow system near the municipal well fields. Analyses of deuterium and oxygen-18 indicate that water in the alluvial aquifer and in the underlying carbonate bedrock aquifer was recharged from precipitation during modern climatic conditions. Analyses of tritium indicate modern, post-1952, water in the alluvial aquifer and older, pre-1952, water in the bedrock aquifer. Mixing of the modern and older waters occurs in areas where (1) the confining layer between the two aquifers is discontinuous, (2) the bedrock aquifer is fractured, or (3) pumping of supply wells induces the flow of water between aquifers. Analyses of chlorofluorocarbons were used to determine the date of recharge of water samples. Water in the bedrock aquifer likely was recharged prior to the 1950s. Water in the alluvial aquifer likely was recharged from the 1960s to 1990s. Biodegradation or sorption probably affected some of the ground water analyzed for chlorofluorocarbons. These processes reduce the concentrations of CFCs, which results in older than actual calculated dates of recharge.  相似文献   

15.
ABSTRACT: The chemical impact of urban runoff water on water quality beneath five retention/recharge basins was investigated as part of the US EPA's Nationwide Urban Runoff Program in Fresno, California. Soil water percolating through alluvium soils and the ground water at the top of the water table were sampled with ceramic/Teflon vacuum water extractors at depths up to 26 m during the two-year investigation. Inorganic and organic pollutants are present in the runoff water delivered to the basins. No significant contamination of percolating soil water or ground water underlying any of the five retention/recharge basins has occurred for constituents monitored in the study. The oldest basins was constructed in 1962. The concentration of selected trace elements in the ground water samples was similar to the levels reported in the regional ground water. None of the pesticides or other organic priority pollutants, for which water samples were analyzed, was s̊ detected except diazinon which was found in trace amounts (0.3 μg/L or less) in only three soil water samples. These results are important to the continued conservation of storm water and the development of a best management practice for storm-water management using retention/recharge basins in a semi-arid climate.  相似文献   

16.
ABSTRACT: Computer simulations involving general circulation models, a hydrologic modeling system, and a ground water flow model indicate potential impacts of selected climate change projections on ground water levels in the Lansing, Michigan, area. General circulation models developed by the Canadian Climate Centre and the Hadley Centre generated meteorology estimates for 1961 through 1990 (as a reference condition) and for the 20 years centered on 2030 (as a changed climate condition). Using these meteorology estimates, the Great Lakes Environmental Research Laboratory's hydrologic modeling system produced corresponding period streamflow simulations. Ground water recharge was estimated from the streamflow simulations and from variables derived from the general circulation models. The U.S. Geological Survey developed a numerical ground water flow model of the Saginaw and glacial aquifers in the Tri‐County region surrounding Lansing, Michigan. Model simulations, using the ground water recharge estimates, indicate changes in ground water levels. Within the Lansing area, simulated ground water levels in the Saginaw aquifer declined under the Canadian predictions and increased under the Hadley.  相似文献   

17.
ABSTRACT: The ground water quality of a shallow unconfined aquifer was monitored before and after implementation of a border strip irrigation scheme, by taking monthly samples from an array of 13 shallow wells. Two 30 m deep wells were sampled to obtain vertical concentration profiles. Marked vertical, temporal, and spatial variabilities were recorded. The monthly data were analyzed for step and linear trends using nonparametric tests that were adjusted for the effects of serial correlation. Average nitrate concentrations increased in the preirrigation period and decreased after irrigation began. This was attributed to wetter years in 1978–1979 than in 1976–1977 which increased leaching, and to disturbance of the topsoil during land contouring before irrigation, followed by excessive drainage after irrigation. Few significant trends were recorded for other determinants, possibly because of shorter data records. Nitrate, sulphate, and potassium concentrations decreased with depth, whereas sodium, calcium, bicarbonate, and chloride concentrations increased. These trends allowed an estimation to be made of the depth of ground water affected by percolating drainage. This depth increased during the irrigation season and after periods of winter recharge. Furthermore, an overall increase in the depth of drainage-affected ground water occurred with time, which paralleled the development of the irrigation scheme.  相似文献   

18.
ABSTRACT: Stable isotopes of deuterium and oxygen-18 of surface and ground water, together with anion concentrations and hydraulic gradients, were used to interpret mixing and flow in ground water impacted by artificial recharge. The surface water fraction (SWF), the percentage of surface water in the aquifer impacted via recharge, was estimated at different locations and depths using measured deuterium/hydrogen (DIH) ratios during the 1992, 1993, and 1994 recharge seasons. Recharged surface water completely displaced the ground water beneath the recharge basins from the regional water table at 7.60 m to 12.16 m below the land surface. Mixing occurred beneath the recharge structures in the lower portions of the aquifer (>12.16 m). Approximately 12 m down-gradient from the recharge basin, the deeper zone (19.15 m depth) of the primary aquifer was displaced completely by recharged surface water within 193, 45, and 55 days in 1992, 1993, and 1994, respectively. At the end of the third recharge season, recharged surface water represented ~50 percent of the water in the deeper zone of the primary aquifer ~1000 m downgradient from the recharge basin. A classic asymmetrical distribution of recharged surface water resulted from the recharge induced horizontal and vertical hydraulic gradients. The distribution and breakthrough times of recharged surface water obtained with stable isotopes concurred with those of major anions and bromide in a tracer test conducted during the 1995 recharge season. This stable isotope procedure effectively quantified mixing between surface and ground water.  相似文献   

19.
ABSTRACT: The quality of ground water in any aquifer takes its final form due to natural mixture of waters, which may originate from different sources. Water quality varies from one aquifer to another and even within the same aquifer itself. Different ground water quality is obtained from wells and is mixed in a common reservoir prior to any consumption. This artificial mixing enables an increase in available ground water of a desired quality for agricultural or residential purposes. The question remains as to what proportions of water from different wells should be mixed together to achieve a desired water quality for this artificial mixture. Two sets of laboratory experiments were carried out, namely, the addition of saline water to a fixed volume of fresh water. After each addition, the mixture volume and the electric conductivity value of the artificially mixed water were recorded. The experiments were carried out under the same laboratory temperature of 20°C. A standard curve was developed first experimentally and then confirmed theoretically. This curve is useful in determining either the volume or discharge ratio from two wells to achieve a predetermined electrical conductivity value of the artificial mixture. The application of the curve is given for two wells within the Quaternary deposits in the western part of the Kingdom of Saudi Arabia.  相似文献   

20.
ABSTRACT: This paper focuses on the development and testing of a mathematical model of an emergency ground water supply operated principally during periods of low streamflow. The process of ground water withdrawal and recharge is simulated taking account of streamflow, water demand, evapotranspiration, natural and artificial recharge and increased evapotranspiration due to artificial recharge, ground water pumpage, and streamflow contribution to pumped water. The model determines whether natural recharge is possible in less time than the return period of drought and also whether artificial recharge is needed. By simulating operation over a long period of time, the model can examine different droughts of short and long duration and can test the operating rules for ground water storage development in an area. Submodels analyze the components of the operating process including ground water flow into the stream, seepage losses, stream portion of well discharge due to induced infiltration and recharge from rainfall or water spreading. The model has been tested for areas in the humid northeastern United States.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号