首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Industrial wastewater is the largest contributor of toxic pollutants and third-largest contributor of nutrients to bodies of water in China, and understanding the characteristics of such pollution is important for water pollution control. In this study, the industrial gray water footprint (GWF) of each industry sector in China’s 31 provinces in 2015 was calculated to identify the pollution characteristics of industrial wastewater discharge and determine how to efficiently allocate investment to pollution reduction. We show that the total industrial GWF of China was 300 billion m3 in 2015 and that the major pollutants were petroleum pollutant (PP), ammonia nitrogen (NH3-N), volatile phenol (VP), and chemical oxygen demand (COD). The water pollution level (WPL) was higher than 1 in Ningxia, Shanxi, Hebei, Tianjin, Shanghai, Henan, and Shandong, indicating that industrial pollution exceeded the carrying capacity of local water bodies in these seven regions. Given equivalent total investment, a scenario that takes the total reduction of the industrial GWF weighted by the WPL in each region as the investment target can better allocate funds to control industrial wastewater pollution in regions with high WPLs relative to a scenario in which investment targets the reduction of the unweighted total industrial GWF. For further industrial GWF reduction in regions with high WPLs, it is crucial to adjust the industrial structure and to upgrade relevant technologies.

  相似文献   

2.

Background and purpose

China's environmental problems and pollution control have global implications. China??s water pollution has been increasing with its urbanization and industrialization. Although great efforts have been taken to keep its wastewater discharge standards in pace with the water pollution development and technological advances, many challenges remain. A summary of the past achievements and lessons as well as the current problems in water pollution may provide a basis for future improvements in China and a reference for other countries.

Methods

Statistical data are summarized to reveal the evolution of China??s population, wastewater discharge and corresponding discharge standards over the past four decades. In particular, the specific control indexes and number of controlled items are discussed in details. The present water pollution situation is clearly illustrated by the water pollution map and the water quality distribution diagram. A comparison between China??s present wastewater discharge standards and those in the USA and the EU are also presented to find the possibilities for future improvement.

Results

The historical origins, major challenges and future perspectives of China??s wastewater discharge standards are overviewed. The barriers and ongoing efforts for standards formulation and implementation are highlighted. Some suggestions for future endeavors are given.

Conclusions

China??s wastewater discharge standard system has seen significant improvement over the past decades, but it still has many defects and limitations. Nonetheless, unprecedented great efforts are underway to address all these challenges. More stringent standards and subsequently a cleaner water environment in China can be expected in the near future.  相似文献   

3.
Abstract

A laboratory scale two‐stage sequencing batch reactor (TSSBR) was used to study the effectiveness of pH as a real‐time control parameter in swine wastewater treatment. A Ringlace media was inserted into the A/O (Anoxic/Oxic) reactor for bacteria immobilization. The TSSBR was subjected to three levels of organic loading. The pH and ORP (Oxidation Reduction Potential) patterns obtained were consistent with distinct features, enabling the real‐time control strategy to effectively set a flexible aeration time pending on influent concentration, hence resulting in flexible cycle time and HRT (Hydraulic Retention Time) for the system. The real‐time process ensured a removal efficiency of over 99% and 95%, respectively, for ammonia and TOC (Total Organic Carbon). For NO3 ‐N and PO4 ‐3, the run with influent TOC = 4,000 mg/L yielded the most efficient removal of 61% and 95%, respectively. Test results suggest that pH can be a viable tool for on‐line real‐time control of a biological treatment process.  相似文献   

4.
The aim of this study was to assess the degradation and mineralization of hydroquinone (HQ) by the Fenton’s process in a bubble column reactor (BCR). The effect of the main operating variables, namely, air flow rate, effluent volume, hydrogen peroxide (H2O2) concentration, catalyst (Fe2+) dose, initial pH, and temperature, were assessed. For all air flow rates tested, no concentration gradients along the column were noticed, evidencing that a good mixing was reached in the BCR. For the best conditions tested ([H2O2] = 500 mg/L, [Fe2+] = 45 mg/L, T = 24 °C, Q air = 2.5 mL/min, pH = 3.0, and V = 5 L), complete HQ degradation was reached, with ~ 39% of total organic carbon (TOC) removal, and an efficiency of the oxidant use—η H2O2—of 0.39 (ratio between TOC removed per H2O2 consumed normalized by the theoretical stoichiometric value); moreover, a non-toxic effluent was generated. Under these conditions, the intermediates and final oxidation compounds identified and quantified were a few carboxylic acids, namely, maleic, pyruvic, and oxalic. As a strategy to improve the TOC removal, a gradual dosage of the optimal H2O2 concentration was implemented, being obtained ~ 55% of mineralization (with complete HQ degradation). Finally, the matrix effect was evaluated, for which a real wastewater was spiked with 100 mg/L of HQ; no reduction in terms of HQ degradation and mineralization was observed compared to the solution in distilled water.  相似文献   

5.
The anoxic–oxic (A/O) process has been extensively applied for simultaneous removal of organic contaminants and nitrogen in wastewater treatment. However, very little is known about its ability to remove toxic materials. Municipal wastewater contains various kinds of pollutants, some of which have recalcitrant genotoxicity and may cause potential threat to environment, and even can lead to extinction of many species. In this study, we have selected three municipal wastewater treatment plants (WWTPs) employing anoxic–oxic (A/O) process to evaluate their ability to remove acute toxicity and genotoxicity of wastewater. Mortality rate of zebrafish (Danio rerio) was used to evaluate acute toxicity, while micronucleus (MN) and comet assays were used to detect genotoxicity. Results showed that in this process the acute toxicity was completely removed as the treatment proceeded along with decrease in chemical oxygen demand (COD) (<50 mg L?1) in the effluent. However, in these treatment processes the genotoxicity was not significantly reduced, but an increase in genotoxicity was observed. Both MN and comet assays showed similar results. The eliminated effluent may pose genotoxic threaten although its COD level has met the Chinese Sewage Discharge Standard. This study suggests that further treatment of the wastewater is required after the A/O process to remove the genotoxicity and minimize the ecotoxicological risk.  相似文献   

6.
7.
A Fenton oxidation system employing zero-valent iron (whose source was swarf, a residue of metallurgical industries, in powder form) and hydrogen peroxide for the treatment of an aqueous solution with six pesticides was developed, and the effect of the iron metal content, pH, and hydrogen peroxide concentration was evaluated. The characterization of the aqueous solution resulted in: pH 5.6, 105 mg L?1 of dissolved organic carbon, and 44.6 NTU turbidity. In addition, the characterization of the swarf by FAAS and ICP-MS showed 98.43?±?7.40 % of zero-valent iron. The removal was strongly affected by the content of iron metal, pH, and hydrogen peroxide concentration. The best degradation conditions were 2.0 g swarf, pH 2.0, and 5 mmol L?1 H2O2. At the end of the treatment, the pesticide degradation ranged from 60 to 100 %, leading to 55 % mineralization. Besides, all hydrogen peroxide was consumed and the determination of total dissolved iron resulted in 2 mg L?1. Thus, the advantages of this system are rapid degradation (up to 20 min), high-degradation rates, simple handling, and low cost.
Figure
A Fenton oxidation system employing Fe0 (in which the source of Fe0 was swarf, a residue in powder form of metallurgical industries) and H2O2 for the degradation of synthetic wastewater comprising six pesticides was developed, and the effect of the amount of Fe0, pH, and H2O2 concentration was evaluated.  相似文献   

8.
Environmental Science and Pollution Research - The microbiome is a term that usually refers to the community of various microorganisms that inhabit/live inside human/animal bodies or on their skin....  相似文献   

9.
This study examined student’s exposure to volatile organic compounds (VOCs) while commuting by bus and motorcycle in Taipei, Taiwan in the winter of 1992. A total of 19 target G5-C10 VOCs on three most frequently used commuting routes were collected on Tenax-GC adsorbent tubes. The VOCs were desorbed by thermal desorption method and analyzed by GCMS. The most abundant VOC exposure experienced by commuters was to toluene. Several alkylated benzenes, such as propyl benzenes, ethyl-methyl-benzenes and trimethyl-benzenes, were relatively abundant on the roads in Taipei. The mean benzene concentration measured in buses was 173 µg/m3 and 379.7 µg/m3 on motorcycles. On the average, the commuters in Taipei experienced about three to eight times higher VOC concentrations than the commuters in Los Angeles, California. Higher VOC concentrations were measured on motorcycles than in buses. The VOC concentrations were not significantly different between morning and afternoon commutes, nor among the three commuting routes. VOC concentrations measured in classrooms at three schools in downtown Taipei did not vary significantly on each sampling day. However, at each school the in-classroom VOC concentrations varied significantly over the six consecutive sampling days. The VOC concentrations measured on the roads were about five times higher than those measured in the school classrooms in the city. Moderate to high correlations were found among most of the measurements of the 19 VOCs. The survey questionnaire indicated that daily commuting time ranged from 45 minutes for elementary school students to 95 minutes for vocational school students. The projected upper-bound cancer risks associated with student’s exposure to benzene ranged from 7.5 x 10-3 to 1.8 x 10-5 during their commutes in Taipei.  相似文献   

10.
Regime shifts and resilience in China’s coastal ecosystems   总被引:1,自引:0,他引:1  
Ke Zhang 《Ambio》2016,45(1):89-98
Regime shift often results in large, abrupt, and persistent changes in the provision of ecosystem services and can therefore have significant impacts on human wellbeing. Understanding regime shifts has profound implications for ecosystem recovery and management. China’s coastal ecosystems have experienced substantial deterioration within the past decades, at a scale and speed the world has never seen before. Yet, information about this coastal ecosystem change from a dynamics perspective is quite limited. In this review, I synthesize existing information on coastal ecosystem regime shifts in China and discuss their interactions and cascading effects. The accumulation of regime shifts in China’s coastal ecosystems suggests that the desired system resilience has been profoundly eroded, increasing the potential of abrupt shifts to undesirable states at a larger scale, especially given multiple escalating pressures. Policy and management strategies need to incorporate resilience approaches in order to cope with future challenges and avoid major losses in China’s coastal ecosystem services.

Electronic supplementary material

The online version of this article (doi:10.1007/s13280-015-0692-2) contains supplementary material, which is available to authorized users.  相似文献   

11.
12.
Particulate matter is an important air pollutant, especially in closed environments like underground subway stations. In this study, a total of 13 elements were determined from PM10 and PM2.5 samples collected at two subway stations (Imam Khomeini and Sadeghiye) in Tehran’s subway system. Sampling was conducted in April to August 2011 to measure PM concentrations in platform and adjacent outdoor air of the stations. In the Imam Khomeini station, the average concentrations of PM10 and PM2.5 were 94.4?±?26.3 and 52.3?±?16.5 μg m?3 in the platform and 81.8?±?22.2 and 35?±?17.6 μg m?3 in the outdoor air, respectively. In the Sadeghiye station, mean concentrations of PM10 and PM2.5 were 87.6?±?23 and 41.3?±?20.4 μg m?3 in the platform and 73.9?±?17.3 and 30?±?15 μg m?3, in the outdoor air, respectively. The relative contribution of elemental components in each particle fraction were accounted for 43 % (PM10) and 47.7 % (PM2.5) in platform of Imam Khomeini station and 15.9 % (PM10) and 18.5 % (PM2.5) in the outdoor air of this station. Also, at the Sadeghiye station, each fraction accounted for 31.6 % (PM10) and 39.8 % (PM2.5) in platform and was 11.7 % (PM10) and 14.3 % (PM2.5) in the outdoor. At the Imam Khomeini station, Fe was the predominant element to represent 32.4 and 36 % of the total mass of PM10 and PM2.5 in the platform and 11.5 and 13.3 % in the outdoor, respectively. At the Sadeghiye station, this element represented 22.7 and 29.8 % of total mass of PM10 and PM2.5 in the platform and 8.7 and 10.5 % in the outdoor air, respectively. Other major crustal elements were 5.8 % (PM10) and 5.3 % (PM2.5) in the Imam Khomeini station platform and 2.3 and 2.4 % in the outdoor air, respectively. The proportion of other minor elements was significantly lower, actually less than 7 % in total samples, and V was the minor concentration in total mass of PM10 and PM2.5 in both platform stations.  相似文献   

13.
The Community Multiscale Air Quality (CMAQ) modeling system Version 5.0 (CMAQv5.0) was released by the U.S. Environmental Protection Agency (EPA) in February 2012, with an interim release (v5.01) in July 2012. Because CMAQ is a community model, the EPA encourages the development of proven alternative science treatments by external scientists and developers that can be incorporated as part of an official CMAQ release. This paper describes the implementation, evaluation, and testing of a plume-in-grid (PinG) module in CMAQ 5.01. The PinG module, also referred to as Advanced Plume Treatment (APT), provides the capability of resolving sub-grid-scale processes, such as the transport and chemistry of point-source plumes, in a grid model. The new PinG module in CMAQ 5.01 is applied and evaluated for two 15-day summer and winter periods in 2005 to the eastern United States, and the results are compared with those from the base CMAQ 5.01. Eighteen large point sources of NOx in the eastern United States were selected for explicit plume treatment with APT in the PinG simulation. The results show that overall model performance is negligibly affected when PinG treatment is included. However, the PinG model predicts significantly different contributions of the 18 sources to pollutant concentrations and deposition downwind of the point sources compared to the base model.
Implications: This study describes the incorporation of a plume-in-grid (PinG) capability within the latest version of the EPA grid model, CMAQ. The capability addresses the inherent limitation of the grid model to resolve processes, such as the evolution of point-source plumes, which occur at scales much smaller than the grid resolution. The base grid model and the PinG version predict different source contributions to ozone and PM2.5 concentrations that need to be considered when source attribution studies are conducted to determine the impacts of large point sources on downwind concentrations and deposition of primary and secondary pollutants.  相似文献   

14.
Environmental Science and Pollution Research - Fenton conditioning processes have been recently employed to improve the dewaterability of sewage sludge. However, it remains unclear whether the...  相似文献   

15.
In this era of globalization, various products and technologies are being developed by the industries. While resources and energy are utilized from processes, wastes are being excreted through water streams, air, and ground. Without realizing it, environmental pollutions increase as the country develops. Effective technology is desired to create green factories that are able to overcome these issues. Wastewater is classified as the water coming from domestic or industrial sources. Wastewater treatment includes physical, chemical, and biological treatment processes. Aerobic and anaerobic processes are utilized in biological treatment approach. However, the current biological approaches emit greenhouse gases (GHGs), methane, and carbon dioxide that contribute to global warming. Microalgae can be the alternative to treating wastewater as it is able to consume nutrients from wastewater loading and fix CO2 as it undergoes photosynthesis. The utilization of microalgae in the system will directly reduce GHG emissions with low operating cost within a short period of time. The aim of this review is to discuss the uses of native microalgae species in palm oil mill effluent (POME) and flue gas remediation. In addition, the discussion on the optimal microalgae cultivation parameter selection is included as this is significant for effective microalgae-based treatment operations.  相似文献   

16.
The paving of gravel roads with an average daily traffic (ADT) over 15 is a least cost method for reducing suspended particulate In the air in Seattle. It is also a good business investment when the ADT exceeds 100. Clean roads, gutters, and parking lots may reduce or eliminate Seattle’s most serious environmental constraint on economic development. In a study done in Seattle’s Duwamish Valley the impact of road dust on air quality was measured by obtaining dust emission factors for vehicles traveling at 10, 20, and 30 mph on gravel as well as dusty paved roads. A University of Washington Mark II Cascade Impactor was mounted on a trailer and towed behind a car to determine the concentration and size distribution of this dust. It was found that each vehicle mile at 20 mph on unpaved roads contributed 7.0 Ib of dust to the air, 1.9 Ib consisting of particles smaller than 10 microns in diameter and 0.24 Ib below 2 microns. Three to eight percent by weight of this respirable dust was free silica, which is potentially toxic. The quantity of dust generated varies as an exponent of the speed. The concentrations of dust found in the air near a dry gravel road with an ADT of 250 reached 584 μg/m3 for an 8 hr work day. A 24 hr suspended particulate reading of 463 μg/m3 total and 3.83 μg/m3 free silica was found beside a dusty paved road with an ADT of 18,000. Nineteen miles of gravel roads and 110 miles of dusty paved roads contributed 2700 tons/year of particulate, of which 700 tons were below 10 microns. Paving or oiling such roads will produce benefits of $3,881,000 yearly in household cleaning, health care, sewer, vehicle operation, and road maintenance costs as well as an increase in property values. Clean roads can lower the cost of clean air in Seattle.  相似文献   

17.
18.

With the rapid development of China’s economy, high energy consumption and high pollution emission have become serious problems. To solve these problems, many studies have been done to evaluate energy and environmental efficiency, as the results can provide valuable information to improve performance. However, the previous research mainly evaluates China’s regional energy and environmental efficiency by considering each region’s industry as a whole system, ignoring the internal structure. In reality, each region mainly includes three parallel types of industry: primary, secondary, and tertiary. Therefore, this paper provides a parallel data envelopment analysis (DEA) approach to evaluate China’s regional energy and environment efficiency by considering these parallel industrial systems. The following findings can be obtained based on the empirical results: (1) the overall energy efficiency of China is low, and the inefficiency of the economic system is mainly sourced from the lower energy and environmental performance of the primary industry and the tertiary industry. (2) the introduction of the environmental variable (CO2) leads to the increase of some backward areas’ efficiencies. (3) the energy efficiency of each provincial region is different, and most of them have their own inefficient industries. (4) the total factor productivity of China is declining, mainly because of the decline of technical efficiency.

  相似文献   

19.
Environmental Science and Pollution Research - We used a green sol–gel synthesis method to fabricate a novel nanoporous copper aluminosilicate (CAS) material. Nanoporous CAS was characterized...  相似文献   

20.
Environmental Science and Pollution Research - Exploring the changes in ecological networks (ENs), its eco-environment effects and the differences in urban agglomerations in various urbanization...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号