首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
为了减少管内气体爆炸造成的损失与破坏,基于大涡模拟LES模型和Zimont燃烧模型,研究泄爆尺寸(直径为40,60,80 mm)和泄爆位置(侧方距点火端1,3,5 m)等泄爆条件对受限空间中氢气燃爆特性的影响。研究结果表明:大孔径泄爆口更好的排放效果造成火焰锋面在通过泄爆口时发生严重畸变,而泄爆口与点火端距离的增加则会削弱火焰锋面畸变的程度,且不同尺寸泄爆口产生的泄压效果差异较大。因此,应考虑将合适尺寸的泄爆口设置于靠近易燃点处。通过探索不同泄爆孔径与泄爆口位置对氢气火焰传播的影响规律,可为实际应用中的安全泄爆起到指导性作用。  相似文献   

2.
The paper describes the analysis of the potential effects of releases from compressed gaseous hydrogen systems on commercial vehicles in urban and tunnel environments using computational fluid dynamics (CFD). Comparative releases from compressed natural gas systems are also included in the analysis.

This study is restricted to typical non-articulated single deck city buses. Hydrogen releases are considered from storage systems with nominal working pressures of 20, 35 and 70 MPa, and a comparative natural gas release (20 MPa). The cases investigated are based on the assumptions that either fire causes a release via a thermally activated pressure relief device(s) (PRD) and that the released gas vents without immediately igniting, or that a PRD fails. Various release strategies were taken into account. For each configuration some worst-case scenarios are considered.

By far the most critical case investigated in the urban environment, is a rapid release of the entire hydrogen or natural gas storage system such as the simultaneous opening of all PRDs. If ignition occurs, the effects could be expected to be similar to the 1983 Stockholm hydrogen accident [Venetsanos, A. G., Huld, T., Adams, P., & Bartzis, J. G. (2003). Source, dispersion and combustion modelling of an accidental release of hydrogen in an urban environment. Journal of Hazardous Materials, A105, 1–25]. In the cases where the hydrogen release is restricted, for example, by venting through a single PRD, the effects are relatively minor and localised close to the area of the flammable cloud. With increasing hydrogen storage pressure, the maximum energy available in a flammable cloud after a release increases, as do the predicted overpressures resulting from combustion. Even in the relatively confined environment considered, the effects on the combustion regime are closer to what would be expected in a more open environment, i.e. a slow deflagration should be expected.

Among the cases studied the most severe one was a rapid release of the entire hydrogen (40 kg) or natural gas (168 kg) storage system within the confines of a tunnel. In this case there was minimal difference between a release from a 20 MPa natural gas system or a 20 MPa hydrogen system, however, a similar release from a 35 MPa hydrogen system was significantly more severe and particularly in terms of predicted overpressures. The present study has also highlighted that the ignition point significantly affects the combustion regime in confined environments. The results have indicated that critical cases in tunnels may tend towards a fast deflagration, or where there are turbulence generating features, e.g. multiple obstacles, there is the possibility that the combustion regime could progress to a detonation.

When comparing the urban and tunnel environments, a similar release of hydrogen is significantly more severe in a tunnel, and the energy available in the flammable cloud is greater and remains for a longer period in tunnels. When comparing hydrogen and natural gas releases, for the cases and environments investigated and within the limits of the assumptions, it appears that hydrogen requires different mitigation measures in order that the potential effects are similar to those of natural gas in case of an accident. With respect to a PRD opening strategy, hydrogen storage systems should be designed to avoid simultaneous opening of all PRD, and that for the consequences of the released energy to be mitigated, either the number of PRDs opening should be limited or their vents to atmosphere should be restricted (the latter point would require validation by a comprehensive risk assessment).  相似文献   


3.
As evidenced by accident statistics, an important factor when considering the safe operation of process plants is the effective mitigation of the effects of gaseous flammable releases, either by a prevention, or a protection approach. A detailed historical analysis was performed considering accidental scenarios associated with the use and management of light gases, starting from raw data selected from FACTS database and analysed by a causal multi-layer method. Results revealed that the major part of the accidental releases involving methane, hydrogen, ethene, ammonia can be attributed to organizational or process/plant immediate causes. As expected, the most frequent scenarios following the release are fire and explosion. We focus our attention on the development of a short-cut method allowing preliminary evaluation of the maximum gaseous build-up under semi-confined conditions, limiting the effects of the fire/explosion scenario to a tolerable level. The limitations of the model that is applied to selected case-studies and require further experimental validation are critically discussed. The results of the application of the model, which can boast of being safe but not disproportionately conservative, can be set as a maximum threshold in proper designing technical measures aiming at limiting the effects to a tolerable level by protection methods, e.g. isolation, venting, suppression and containment.  相似文献   

4.
为了探究易燃易爆场所静电事故形成过程及防护机理,基于事故链式理论,以及静电点燃源形成过程和爆炸性环境形成过程这2条并行支链,绘制了易燃易爆场所静电事故链路;通过事故案例说明了静电事故链路的实用性;研究了静电荷、易燃/可燃物质在外界扰动作用下的特征形态。研究结果表明:静电事故断链减灾模式包括静电点燃源断链减灾模式、爆炸性环境断链减灾模式以及降低事故影响的事故后果断链减灾模式;针对静电事故的各类断链减灾模式,提出了相应的防护措施,可为易燃易爆场所静电事故防护提供系统性的指导方案。  相似文献   

5.
This paper reports the results of flammability studies for methane, propane, hydrogen, and deuterium gases in air conducted by the Pittsburgh Research Laboratory. Knowledge of the explosion hazards of these gases is important to the coal mining industry and to other industries that produce or use flammable gases. The experimental research was conducted in 20 L and 120 L closed explosion chambers under both quiescent and turbulent conditions, using both electric spark and pyrotechnic ignition sources. The data reported here generally confirm the data of previous investigators, but they are more comprehensive than those reported previously. The results illustrate the complications associated with buoyancy, turbulence, selective diffusion, and ignitor strength versus chamber size. Although the lower flammable limits (LFLs) are well defined for methane (CH4) and propane (C3H8), the LFLs for hydrogen (H2) and its heavier isotope deuterium (D2) are much more dependent on the limit criterion chosen. A similar behavior is observed for the upper flammable limit of propane. The data presented include lower and upper flammable limits, maximum pressures, and maximum rates of pressure rise. The rates of pressure rise, even when normalized by the cube root of the chamber volume (V1/3), are shown to be sensitive to chamber size.  相似文献   

6.
This paper discusses the results of an experimental program carried out to determine dust cloud deflagration parameters of selected solid-state hydrogen storage materials, including complex metal hydrides (sodium alanate and lithium borohydride/magnesium hydride mixture), chemical hydrides (alane and ammonia borane) and activated carbon (Maxsorb, AX-21). The measured parameters include maximum deflagration pressure rise, maximum rate of pressure rise, minimum ignition temperature, minimum ignition energy and minimum explosible concentration. The calculated explosion indexes include volume-normalized maximum rate of pressure rise (KSt), explosion severity (ES) and ignition sensitivity (IS). The deflagration parameters of Pittsburgh seam coal dust and Lycopodium spores (reference materials) are also measured. The results show that activated carbon is the safest hydrogen storage media among the examined materials. Ammonia borane is unsafe to use because of the high explosibility of its dust. The core insights of this contribution are useful for quantifying the risks associated with use of these materials for on-board systems in light-duty fuel cell-powered vehicles and for supporting the development of hydrogen safety codes and standards. These insights are also critical for designing adequate safety features such as explosion relief venting and isolation devices and for supplementing missing data in materials safety data sheets.  相似文献   

7.
Powdered materials are widely used in industrial processes, chemical processing, and nanoscience. Because most flammable powders and chemicals are not pure substances, their flammability and self-heating characteristics cannot be accurately identified using safety data sheets. Therefore, site staff can easily underestimate the risks they pose. Flammable dust accidents are frequent and force industrial process managers to pay attention to the characteristics of flammable powders and create inherently safer designs.This study verified that although the flammable powders used by petrochemical plants have been tested, some powders have different minimum ignition energies (MIEs) before and after drying, whereas some of the powders are released of flammable gases. These hazard characteristics are usually neglected, leading to the neglect of preventive parameters for fires and explosions, such as dust particle size specified by NFPA-654, MIE, the minimum ignition temperature of the dust cloud, the minimum ignition temperature of the dust layer, and limiting oxygen concentration. Unless these parameters are fully integrated into process hazard analysis and process safety management, the risks cannot be fully identified, and the reliability of process hazard analysis cannot be improved to facilitate the development of appropriate countermeasures. Preventing the underestimation of process risk severity due to the fire and explosion parameters of unknown flammable dusts and overestimation of existing safety measures is crucial for effective accident prevention.  相似文献   

8.
During the decommissioning of certain legacy nuclear waste storage plants it is possible that significant releases of hydrogen gas could occur. Such an event could result in the formation of a flammable mixture within the silo ullage and, hence, the potential risk of ignition and deflagration occurring, threatening the structural integrity of the silo. Very fine water mist fogs have been suggested as a possible method of mitigating the overpressure rise, should a hydrogen–air deflagration occur. In the work presented here, the FLACS CFD code has been used to predict the potential explosion overpressure reduction that might be achieved using water fog mitigation for a range of scenarios where a hydrogen–air mixture, of a pre-specified concentration (containing 800 L of hydrogen), uniformly fills a volume located in a model silo ullage space, and is ignited giving rise to a vented deflagration. The simulation results suggest that water fog could significantly reduce the peak explosion overpressure, in a silo ullage, for lower concentration hydrogen–air mixtures up to 20%, but would require very high fog densities to be achieved to mitigate 30% hydrogen–air mixtures.  相似文献   

9.
The hazards of dust explosions prevailing in plants are dependent on a large variety of factors that include process parameters, such as pressure, temperature and flow characteristics, as well as equipment properties, such as geometry layout, the presence of moving elements, dust explosion characteristics and mitigating measures. A good dust explosion risk assessment is a thorough method involving the identification of all hazards, their probability of occurrence and the severity of potential consequences. The consequences of dust explosions are described as consequences for personnel and equipment, taking into account consequences of both primary and secondary events.While certain standards cover all the basic elements of explosion prevention and protection, systematic risk assessments and area classifications are obligatory in Europe, as required by EU ATEX and Seveso II directives. In the United States, NFPA 654 requires that the design of the fire and explosion safety provisions shall be based on a process hazard analysis of the facility, process, and the associated fire or explosion hazards. In this paper, we will demonstrate how applying such techniques as SCRAM (short-cut risk analysis method) can help identify potentially hazardous conditions and provide valuable assistance in reducing high-risk areas. The likelihood of a dust explosion is based on the ignition probability and the probability of flammable dust clouds arising. While all possible ignition sources are reviewed, the most important ones include open flames, mechanical sparks, hot surfaces, electric equipment, smoldering combustion (self-ignition) and electrostatic sparks and discharges. The probability of dust clouds arising is closely related to both process and dust dispersion properties.Factors determining the consequences of dust explosions include how frequently personnel are present, the equipment strength, implemented consequence-reducing measures and housekeeping, as risk assessment techniques demonstrate the importance of good housekeeping especially due to the enormous consequences of secondary dust explosions (despite their relatively low probability). The ignitibility and explosibility of the potential dust clouds also play a crucial role in determining the overall risk.Classes describe both the likelihood of dust explosions and their consequences, ranging from low probabilities and limited local damage, to high probability of occurrence and catastrophic damage. Acceptance criteria are determined based on the likelihood and consequence of the events. The risk assessment techniques also allow for choosing adequate risk reducing measures: both preventive and protective. Techniques for mitigating identified explosions risks include the following: bursting disks and quenching tubes, explosion suppression systems, explosion isolating systems, inerting techniques and temperature control. Advanced CFD tools (DESC) can be used to not only assess dust explosion hazards, but also provide valuable insight into protective measures, including suppression and venting.  相似文献   

10.
A pilot scale interconnected vessels experiment system was established, and the closed and vented gas explosion characteristics in the system were studied, using 10% methane–air mixture. Regularity of pressure variation in vessels and flame propagation in linked pipes was analyzed. Furthermore, the effects of transmission style, ignition position, pipe length, and initial pressure on explosion severity were discussed. For the closed explosion: explosion in interconnected vessels presents strongly destructive power to secondary vessel, especially transmission from the big vessel to the small one; the worst ignition position is shifting from ignition in the interconnected pipe to the walls of the two vessels; as far as ignition in big vessel is concerned, the peak pressure in secondary vessel increases with the pipe length much faster than that for ignition in small vessel; the peak pressures in two vessels are approximate linear functions of initial pressure. For the vented explosion: the transmission style and interconnected pipe length have significant impacts on the effect of venting on the protection; in order to obtain the better venting effect, the use of a divergent interconnected pipe from the big vessel to the small one in industry is advised and it is necessary to reduce the interconnected pipe length as far as possible or install flame arrester in the interconnected pipe.  相似文献   

11.
井喷失控点火时间与方位探讨   总被引:1,自引:0,他引:1  
利用计算流体力学方法(CFD)对井喷失控后天然气扩散过程进行研究,在有限元基础上建立模型,采用κ-ε紊流模型求解得出井喷失控后可燃性蒸气云随时间、风速变化的影响情况,求出稳态以后易爆区域的蒸气云形状。取5.0%和15%作为甲烷的爆炸上、下限,在不同区域进行点火求解爆燃结果,通过比较给出推荐的点火时间和点火方位。该研究成果可对井喷失控蒸气云爆燃危害性进行预测,有助于指导井喷失控进行点火放喷工作,避免爆燃事故的发生。  相似文献   

12.
针对某不饱和聚酯树脂钮扣厂在除尘设备维修过程中发生的粉尘爆炸事故,探究静电引起此次事故的可能性并提出防护措施。通过实验测定不饱和聚酯树脂钮扣粉尘的爆炸特性参数,进而确定其静电爆炸敏感性。结果发现:不饱和聚酯树脂钮扣粉尘云最小点火能MIE为4~10 mJ、最低着火温度MIT为480 ℃、粉尘层最低着火温度LIT>400 ℃。表明,此粉尘属易燃粉尘,其粉尘爆炸敏感度极高,被静电火花点燃的可能性极大,在生产过程中,应采取静电防护措施。  相似文献   

13.
Computational modeling is a useful tool in determining the consequences from vapor cloud explosions. Here an approach that uses a flame-speed based combustion model is evaluated. Various scenarios of explosions in full-scale off-shore modules are simulated and compared to available test data. The ignition location of the cloud and available venting paths are found to affect the overpressure field in and outside the module. For end ignition cases, the combustion of gas pushed out of the module is found to play a key role. Using the flame-speed based model with appropriate effective flame speeds is found to provide accurate simulations.  相似文献   

14.
为了研究管道内氢气的爆燃转爆轰及其抑制过程,对单个障碍物管道中氢气-空气混合物燃爆过程以及多级泄爆进行了二维数值模拟。基于氢气-空气19步详细化学反应动力学机理,以及k-ε湍流模型、概率密度函数输运方程和同位网格SIMPLE算法,采用计算流体软件Fluent进行模拟。结果表明:密闭管道无泄爆时,在距点火端1.5 m左右爆燃转为爆轰;泄爆口的位置对管道内氢气-空气预混气体的爆炸参数有重要影响,泄爆口位于管道中部时,能降低管道内爆轰超压,泄爆效果较好;位于管道中部单个泄爆口泄爆时,有效降低爆轰超压,管道中部设置2个泄爆口时,能通过压力和混合气体的泄放将管道中已经发生的爆轰衰减为爆燃;当有3个泄爆口泄爆时,管道中没有发生爆轰,达到良好的泄爆效果。  相似文献   

15.
The safe operation of hydrocarbon liquid-phase oxidation by air or oxygen requires the knowledge on the flammability of hydrocarbon/oxygen mixtures in both the vapor space and vapor bubbles. The latter is of particular importance in situation where pure oxygen is used as the oxidant as most bubbles are expected to be flammable and explosive. New experimental findings are presented for ignition and explosion in cyclohexane liquid under oxygen oxidation conditions. A bubble column is constructed and fitted with multiple igniters. Experiments were performed at liquid temperatures between 373.15 and 423.15 K under various flow rates of pure oxygen. Two drastic different ignition and explosion behaviors were observed. The first is a typical bubble explosion from the direct ignition of the flammable bubbles in the liquid. The explosion occurs immediate following the ignition and do not produce significant energy that endanger the system. The other is a remote, delayed ignition and explosion in the vapor space that can produce significant overpressure and endanger the system. The explosion is attributed to the ignition of flammable vapor space by active free radicals from cyclohexyl hydroperoxide decomposition. A mechanism is proposed for the remote, delayed ignition to occur in the oxidation system. It is concluded that explosion in an oxidizing, bubbly liquid is not only a likely scenario but also a severe scenario, and cyclohexane oxidation should not be carried out directly with pure oxygen and without any inerting.  相似文献   

16.
Most industrial powder processes handle mixtures of various flammable powders. Consequently, hazard evaluation leads to a reduction of the disaster damage that arises from dust explosions. Determining the minimum ignition energy (MIE) of flammable mixtures is critical for identifying possibility of accidental hazard in industry. The aim of this work is to measure the critical ignition energy of different kinds of pure dusts with various particle sizes as well as mixtures thereof.The results show that even the addition of a modest amount of a highly flammable powder to a less combustible powder has a significant impact on the MIE. The MIE varies considerably when the fraction of the highly flammable powder exceeds 20%. For dust mixtures consisting of combustible dusts, the relationship between the ignition energy of the mixture and the minimum ignition energy of the components follows the so-called harmonic model based upon the volume fraction of the pure dusts in the mixture. This correlation provides results which show satisfactory agreement with the experimental values.  相似文献   

17.
Accidental gas explosions occurred at a refuse-derived-fuel (RDF) storage in Japan, and two fire fighters on duty were dead. The flammable gases, which caused the gas explosions generated during a RDF fire. It means that gas explosions could occur in the use of solid fuels under certain conditions. This study has been conducted for exploring the process to gas explosions in the RDF storage. The temperature at a part of the RDF pile in the storage was inferred to spontaneously increase, and the prediction of the temperature increase was attempted on the basis of the Frank-Kamenetskii theory. It was shown that the critical temperature of RDF for spontaneous temperature rise depends on the size of the pile. Larger the pile, lower the critical temperature. The possibility of accumulation of flammable gas in the space of the RDF storage is discussed. It is indicated that the spread rate of thermal wave is slow and a high temperature region likely established. After the RDF pile ignites, the oxygen concentration near the burning site becomes low and the flammable species components in the generated gas increases. Those species pass through surrounding low temperature region and come out into the space over the RDF pile without combustion. An explosion would occur when a fresh air comes into the storage, mixes with the flammable gas coming out from the pile to form a flammable mixture, and then the flammable mixture ignites. The most effective means to prevent accidental explosions is to avoid spontaneous ignition by cooling the heated RDF. If spontaneous ignition occurs, elimination of flammable gases from the storage should be strongly recommended.  相似文献   

18.
The explosion of flammable mixtures in interconnected compartments is commonly defined as “pressure piling”. Peak pressures much higher than the predictable thermodynamic values are likely to be generated in this geometry, yielding the phenomenon of major interest in industrial safety. In this paper, a CFD model was implemented, aiming at understanding the major factors affecting pressure piling in two cylindrical interconnected vessels, by varying the volume ratio between the two interconnected vessels and the ignition position. A combustion model was specifically developed to follow the flame propagation in any combustion regimes as a function of the local conditions: laminar, flamelet and distributed reaction zone.The model was validated by comparison with experimental results. The agreement between the experiments and the simulations has allowed the interpretation of the pressure piling phenomenon and the understanding of the mechanisms involved. More precisely, the results have showed that the pressure peak intensity is mainly affected by the coupling between the pre-compression of the mixture in the secondary vessel and the violence of explosion in the same vessel as related to the venting time, the latest quantified by the turbulent Bradley number, Brt i.e. by the reaction time to the venting time ratio.  相似文献   

19.
20.
利用球型容器与管道组合,开展连通容器气体爆炸与泄爆实验,分析连通条件下,火焰在管道中的传播过程及其对起爆容器和传爆容器的压力影响。实验结果表明:连通容器气体爆炸中,火焰从起爆容器到传爆容器传播经历了一段不断加速,但加速度不断减小的过程;泄爆过程中,火焰传播过程与密闭爆炸时基本一致。管道中火焰加速传播,使得传爆容器的爆炸压力和强度相较于作为起爆容器时均明显增加,危险更大,采用与起爆容器相同的泄爆面积,无法满足对连通容器中传爆容器的泄爆。同时,泄爆是一个快速的能量泄放过程应选择合理的泄爆方式,防止二次危害。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏