首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Weber R  Hagenmaier H 《Chemosphere》1999,38(3):529-549
The pyrolysis of chlorinated phenates at a temperature of about 280 degrees C results in the formation of definite chlorinated dibenzodioxin (PCDD) congeners [1-3]. It is shown that in gas phase reactions chlorophenols react in the presence of oxygen above 340 degrees C not only to PCDD but also to chlorinated dibenzofurans (PCDF). The mechanism of this reaction of chlorophenols to PCDD and PCDF was elucidated. In a first step phenoxyradicals are formed which are capable of forming PCDDs and PCDFs. This is confirmed by the oxygen dependency of the reaction. In an argon atmosphere no dimerization of chlorophenols could be observed at 420 degrees C. By the identification of intermediates and by analyzing the PCDF isomers formed from individual chlorophenols the reaction pathway is elucidated. As intermediates in the formation of PCDFs polychlorinated dihydroxybiphenyls (DOHB) were identified. These are most likely formed by the dimerization of two phenoxy radicals at the hydrogen substituted carbons in ortho-positions under simultaneous movement of the hydrogen atoms to the phenolic oxygen PCDDs are formed in the gas phase via ortho-phenoxyphenols (POP) analogous to the pyrolysis of phenates, but due to the radical mechanism in the first condensation step to POPs not only a chlorine atom is capable for substitution but also the hydrogen atoms. The formation of the DOHBs and their condensation to PCDFs and hydroxylated PCDFs as well as the ratio of PCDD to PCDF formed show a strong dependency on the reaction temperature, the substitution pattern of the chlorophenols and the oxygen concentration.  相似文献   

2.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

3.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

4.
Five fluidized bed incinerators combusting municipal solid waste were assessed for the impact of coplanar PCBs on total TEQ emission. In 17 stack measurements, the coplanar PCBs contributed on average less than 3% to total TEQ with a maximum contribution of 7.5% to total TEQ in one measurement. Differences in the design of the flue gas cooling section did not show an effect on the impact of coplanar PCBs on total TEQ. The effect of emission control devices on the impact of coplanar PCBs on the total TEQ was studied in more detail at one incinerator. The relative contribution of PCBs to total TEQ increased along the flue gas line. This was caused by a slightly higher removal efficiency for TEQ relevant PCDDs/PCDFs compared to coplanar PCBs by the bag filters and a higher destruction efficiency for PCDDs/PCDFs compared to PCBs by the SCR catalyst. Additionally, the removal efficiencies of the emission control devices (bag filters and catalyst) for other chlorinated aromatic compounds which have been proposed as TEQ indicator compounds (polychlorinated benzenes and polychlorinated phenols) were compared with those for PCDDs/PCDFs and coplanar PCBs. Removal efficiencies for polychlorinated benzenes or polychlorinated phenols considerably differed from those of PCDD/PCDF and coplanar PCBs. Implications for TEQ assessments using indicator compounds as proposed in the literature are discussed.  相似文献   

5.
This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 degrees C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 microg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 microg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

6.
Formation, release and control of dioxins in cement kilns   总被引:2,自引:1,他引:1  
Karstensen KH 《Chemosphere》2008,70(4):543-560
Co-processing of hazardous wastes in cement kilns have for decades been thought to cause increased emissions of PCDD/PCDFs--a perception that has been evaluated in this study. Hundreds of PCDD/PCDF measurements conducted by the cement industry and others in the last few years, on emissions and solid materials, as well as recent test burns with hazardous wastes in developing countries do not support this perception. Newer data has been compared with older literature data and shows in particular that many emission factors have to be reconsidered. Early emission factors for cement kilns co-processing hazardous waste, which are still used in inventories, are shown to be too high compared with actual measurements. Less than 10 years ago it was believed that the cement industry was the main contributor of PCDD/PCDFs to air; data collected in this study indicates however that the industry contributes with less than 1% of total emissions to air. The Stockholm Convention on POPs presently ratified by 144 parties, classifies cement kilns co-processing hazardous waste as a source category having the potential for comparatively high formation and release of PCDD/PCDFs. This classification is based on early investigations from the 1980s and 1990s where kilns co-processing hazardous waste had higher emissions compared to those that did not burn hazardous waste. However, the testing of these kilns was often done under worst case scenario conditions known to favour PCDD/PCDF formation. More than 2000 PCDD/PCDF cement kiln measurements have been evaluated in this study, representing most production technologies and waste feeding scenarios. They generally indicate that most modern cement kilns co-processing waste today can meet an emission level of 0.1ngI-TEQ/m(3), when well managed and operated. In these cases, proper and responsible use of waste including organic hazardous waste to replace parts of the fossil fuel does not seem to increase formation of PCDD/PCDFs. Modern preheater/precalciner kilns generally seems to have lower emissions than older wet-process cement kilns. It seems that the main factors stimulating formation of PCDD/PCDFs is the availability of organics in the raw material and the temperature of the air pollution control device. Feeding of materials containing elevated concentrations of organics as part of raw-material-mix should therefore be avoided and the exhaust gases should be cooled down quickly in long wet and long dry cement kilns without preheating. PCDD/PCDFs could be detected in all types of solid samples analysed: raw meal, pellets and slurry; alternative raw materials as sand, chalk and different ashes; cement kiln dust, clinker and cement. The concentrations are however generally low, similar to soil and sediment.  相似文献   

7.
In a laboratory model system consisting of fly ash from municipal waste incinerator, CuCl2 x 2H2O, NaCl and activated carbon in N2 + 10% O2 atmosphere, the de novo synthetic reactions of formation of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) were studied under laboratory conditions in the presence of sulfur dioxide, hydrogen peroxide, and sulfuric acid. It has been found that the formation of PCDD is suppressed by sulfur dioxide more efficiently than the formation of PCDF. A similar effect has also been observed in the presence of hydrogen peroxide. The formation of PCDF is strongly suppressed in the presence of sulfuric acid. On the basis of the experimental results and thermodynamic calculations, the following mechanisms are proposed and discussed: oxidative destruction of PCDD and PCDF oxygen rings, conversion of cupric chloride and possibly also cupric oxide into the non-reactive sulfate, and the Deacon oxychlorination processes catalyzed by cupric chloride.  相似文献   

8.
Alumina was studied as a model matrix for formation and dechlorination reactions of PCDDs and PCDFs. Only small differences in PCDD and PCDF formation were found between de-novo synthesis on alumina and on fly ash. The amounts of PCDDs and PCDFs formed on acidic alumina were much larger than on neutral and alkaline alumina. OCDD and OCDF were rapidly dechlorinated on basic alumina.  相似文献   

9.
Studies on the formation of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) during the electrolysis of sodium chloride solution (brine) using graphite or titanium electrodes were carried out at a laboratory scale. High concentrations of PCDFs but no PCDDs were formed in tests using graphite electrodes. With titanium electrodes, PCDFs were only formed when tar pitch was added and mainly originated from the dibenzofuran present in the tar. For the first time, a detailed assessment of the formation of mono- to octachlorinated PCDD/PCDF from tar pitch was investigated. The assessment included of the chlorination steps proved that PCDFs were formed by successive lateral chlorinated from dibenzofuran to MonoCDFs, DiCDFs, and TriCDFs to form the typical known “chlorine pattern” of TetraCDF to OctaCDF with a dominance of 1,2,7,8- and 2,3,7,8-TetraCDFs, 1,2,3,7,8-PentaCDF, and 1,2,3,4,7,8-HexaCDF as marker congeners. The final homologue distributions depended on reaction time and reaction temperature. In addition, electrolysis with non-chlorinated dibenzo-p-dioxins, dibenzofuran, and biphenyl was carried out. As a result, PCDDs, PCDFs, and PCB were formed at comparable yields. Congener patterns in soil samples from a PCDD/F-contaminated site where chlor-alkali electrolysis had been operated for decades in Japan had identical isomer distribution demonstrating the source and contamination potential and risk of these processes. Therefore, sites where in the past 120 years chlor-alkali electrolysis has been operated or where residues from chlor-alkali production or other chlorine using industries have been disposed should be assessed for their pollution level and exposure relevance. The assessment of total organohalogen content revealed that PCDF is only a small fraction of organohalogens in the contaminated soils. For an appropriate risk assessment, also other chlorinated aromatic compounds such as PCBs or PCNs need to be considered.  相似文献   

10.
Different 2,3,7,8-substituted polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs) were investigated for their retention behaviour on a disposable minicolumn containing activated carbon AX-21. Elution behaviour and recovery were examined, using native and radiolabelled PCDD and PCDF isomers.

A comparison of the total mass chromatograms of PCDDs and PCDFs in an extract from animal adipose tissue, before and after activated carbon treatment, demonstrates the efficiency of this cleanup step with respect to the elimination of interfering compounds.  相似文献   


11.
Yamada M  Waki I  Sakairi M  Sakamoto M  Imai T 《Chemosphere》2004,54(10):1475-1480
The decrease of trichlorophenol by injecting oxidation catalyst into a municipal solid waste incinerator was monitored in real time. Direct sampling atmospheric pressure chemical ionization (APCI)/ion trap mass spectrometry (ITMS) was used for the real-time monitoring. The oxidation catalyst was iron oxide type, which exponentially reduced trichlorophenol emission. CO emission, however, did not show any correlation with the catalyst injection rate. Simultaneous analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs) suggested that real-time monitoring of trichlorophenol as a surrogate of PCDDs/PCDFs, has a potential to timely control the optimum injection rate of PCDD/PCDF suppression catalyst continuously and economically.  相似文献   

12.
The River Po is the main Italian river draining one of the most populated and industrialised regions in Italy. As part of a monitoring project to assess environmental quality in the River Po, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in bottom sediments collected along the whole course of the river, from the spring to the delta, downstream from the confluence of its main tributaries. The aim was to investigate the level of contamination in the main Italian river and the contribution of contaminant loads from the subbasins. Composite sediment samples were collected in summer and winter surveys in low-flow water conditions and analysed by HRGC-HRMS for PCDD and PCDF homologue groups and for the 2,3,7,8-substituted congeners. The spatial trend observed in the Po River for PCDD and PCDF concentrations varied depending on the load of contaminants received from the tributaries and the processes of sedimentation. The sum of PCDD and PCDF concentrations, and the toxic equivalent content, ranged from 121 to 814 and from 1.3 to 13 ng/kg dry weight sediment, respectively. These levels of contamination seem lower than in the sediments of rivers draining highly industrialised areas. The PCDD and PCDF homologue profiles in all the samples were very similar, suggesting a common source of this contamination in the River Po. Principal component analysis suggested that widespread sources, such as urban runoff and domestic wastewaters, are probably the main cause of these levels of PCDDs and PCDFs.  相似文献   

13.
Frode Brakstad 《Chemosphere》1992,24(12):1885-1903
The combined use of principal component analysis and partial least squares regression to the interpretation of polychlorinated dibenzofuran (PCDF) and dibenzo-p-dioxin (PCDD) patterns in crabs are investigated. By exploratory principal component analysis, the PCDFs and the PCDDs are ranked according to their specificity to the emission source. Among the most specific PCDFs to the emission are the 12368/13479-PeCDF and 12478-PeCDF. The 123789-HxCDD isomer is the only specific PCDD to the emission source. Partial least squares regression is used both to explore the determination of sex specific isomers, and in confirmatory analysis by quantitatively relating the pollution waste to the distance from the emission source. 123678-HxCDF is statistically significant for the separation between male and female crabs collected at the same distance from the emission source, while no separation between male and female crabs is evident from 1234789-HpCDF, Octa-CDF, 2,3,7,8-TCDD and Octa-CDD. This observation is somewhat more shaded than what has previously been reported in the literature on differences in male and female crabs. A linear relationship exists between the logtransformed distance and the concentration of PCDFs and PCDDs in male crabs collected between 18 and 33 km from the source. This model underestimates the predicted distance of crabs collected between 33 and 56 km, possible due to a higher sedimentation rate at distances closer to the fjord and the factory.

Although applied to PCDF/PCDD data in this case, the outlined multivariate methods should be applicable to all kind of similar environmental surveys.  相似文献   


14.
Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs) contained in the smoke generated from rice straw burning in post-harvest paddy fields in Japan were analyzed to determine their congener profiles. Both the apportionment of toxic equivalent (TEQ) by using indicative congeners and the comparison of the homolog profiles showed that the PCDDs/PCDFs/DL-PCBs present in the rice-straw smoke were greatly influenced by those present as impurities in pentachlorophenol (PCP) and chlornitrofen (CNP, 4-nitrophenyl-2,4,6-trichlorophenyl ether) formulations that had been widely used as herbicides in paddy fields in Japan. Further, in order to investigate the effects of paddy-field soil on the PCDDs/PCDFs/DL-PCBs present in rice-straw smoke, PCDD/PCDF/DL-PCB homolog profiles of rice straw, rice-straw smoke and paddy-field soil were compared. Rice-straw smoke was generated by burning rice straw on a stainless-steel tray in a laboratory. The results suggested that the herbicides-originated PCDDs/PCDFs/DL-PCBs and the atmospheric PCDDs/PCDFs/DL-PCBs contributed predominantly to the presence of PCDDs/PCDFs/DL-PCBs in the rice-straw smoke while the contribution of PCDDs/PCDFs/DL-PCBs formed during rice straw burning was relatively minimal. The major sources of the PCDDs/PCDFs/DL-PCBs found in the rice-straw smoke were attributed primarily to the paddy-field soil adhered to the rice straw surface and secondarily to the air taken by the rice straw. The principal component analysis supported these conclusions. It is concluded that rice straw burning at paddy fields acts as a driving force in the transfer of PCDDs/PCDFs/DL-PCBs from paddy-field soil to the atmosphere.  相似文献   

15.
Abstract

This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 °C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 μg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 μg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

16.
Paddy soils and sediments from the Yoneshirogawa, Omonogawa, and Koyoshigawa River Basins in Akita were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The levels and compositions in those samples including soils from non-agricultural areas (non-agricultural soils) were investigated using isomer-specific analysis to determine characteristic sources. The PCDD/PCDF compositions in the samples were compared with respect to possible sources. The PCDD/PCDF concentrations in paddy soils were much higher than those in the non-agricultural soils and much higher than those found in other parts of Japan. Although PCDD/PCDFs were ubiquitous in sediments from river sources to mouths of the respective river basins, those concentrations were much lower than those from paddy soils and non-agricultural soils, and from other parts of Japan. Comparison of PCDD/PCDF homologues and isomer compositions for samples indicated that compositions of paddy soils and sediments, except for those from river sources, had similar characteristics to PCDD/PCDFs originating from impurities in herbicides, 2,4,6-trichlorophenyl 4-nitrophenyl ether (CNP) and pentachlorophenol (PCP), and that compositions of river-source sediments and non-agricultural soils resembled those of atmospheric depositions. Results of statistical analyses suggest that PCDD/PCDF contamination of paddy soils and sediments is attributable mainly to three sources: CNP, PCP, and atmospheric deposition. Results of this study also demonstrate that CNP and PCP are not only important contaminants of local areas of Japan, but that they exist throughout Akita, in northern Japan. We therefore conclude that PCDD/PCDF pollution caused by those compounds has a widespread influence on paddy soils and river sediments in Japan.  相似文献   

17.
Ferrario J  Byrne C 《Chemosphere》2002,46(9-10):1297-1301
Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and -furans (PCDDs/PCDFs). The processed ball clay had average PCDD concentrations of 3.2 ng/g toxic equivalents, a congener profile, and isomer distribution consistent with those found previously in raw ball clay. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. The final fired ceramic products were found to be free of PCDDs/PCDFs at the LODs. A consideration of the conditions involved in the firing process suggests that the PCDDs, if not destroyed, may be released to the atmosphere and could represent an as yet unidentified source of dioxins to the environment. In addition, the PCDDs in clay dust generated during manufacturing operations may represent a potential occupational exposure.  相似文献   

18.
Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and -furans (PCDDs/PCDFs). The processed ball clay had average PCDD concentrations of 3.2 ng/g toxic equivalents, a congener profile, and isomer distribution consistent with those found previously in raw ball clay. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. The final fired ceramic products were found to be free of PCDDs/PCDFs at the LODs. A consideration of the conditions involved in the firing process suggests that the PCDDs, if not destroyed, may be released to the atmosphere and could represent an as yet unidentified source of dioxins to the environment. In addition, the PCDDs in clay dust generated during manufacturing operations may represent a potential occupational exposure.  相似文献   

19.
Hirako M 《Chemosphere》2008,71(2):219-226
To determine the distribution of persistent organochlorine compounds in beef cattle, concentrations of 2,3,7,8-substituted PCDDs, PCDFs and dioxin-like PCBs were measured in the blood, testes and adipose tissue of four two-month-old Japanese Black calves. Of 29 congeners analyzed, 19, 20 and 28 were detected in the blood, testes and adipose tissue, respectively, of three or all calves. Total toxic equivalents (TEQs) were similar in the testes and adipose tissue, and approximately two times higher than in the blood on a lipid weight basis (P<0.05). More PCDDs and PCDFs had accumulated in the testes than in adipose tissue (P<0.01), but more dioxin-like PCBs were found in adipose tissue than in the testes (P<0.0001). Accumulation patterns in the testes and adipose tissue varied among the congeners of PCDD and PCDF, whereas the patterns were similar in dioxin-like PCBs. In particular, highly substituted PCDD congeners were detected at high concentrations in the testes but at lower concentrations in adipose tissue compared with other congeners. By contrast, accumulation levels of highly substituted PCDFs were lower in both those tissues than the other congeners. In conclusion, it was demonstrated that PCDDs, PCDFs and dioxin-like PCBs leave the circulation and accumulate in the testes and adipose tissue in bovine calves. It was suggested that congeners of PCDD, especially highly substituted PCDDs, and PCDFs have a tendency to accumulate in the testis and dioxin-like PCB congeners accumulate readily in adipose tissue.  相似文献   

20.
Laboratory bleaching experiments were performed to investigate PCDD/PCDF formation mechanisms. The results indicated that there were two (or more) mechanisms; direct chlorination of DBD/DBF and formation from precursors which are not extractable. In general, PCDDs/PCDFs are formed in the C stage but some minor isomers were found to be formed in the E stage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号