首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In response to concerns about amphibian declines, a study evaluating and validating amphibian monitoring techniques was initiated in Shenandoah and Big Bend National Parks in the spring of 1998. We evaluate precision, bias, and efficiency of several sampling methods for terrestrial and streamside salamanders in Shenandoah National Park and assess salamander abundance in relation to environmental variables, notably soil and water pH. Terrestrial salamanders, primarily redback salamanders (Plethodon cinereus), were sampled by searching under cover objects during the day in square plots (10 to 35 m2). We compared population indices (mean daily and total counts) with adjusted population estimates from capture-recapture. Analyses suggested that the proportion of salamanders detected (p) during sampling varied among plots, necessitating the use of adjusted population estimates. However, adjusted population estimates were less precise than population indices, and may not be efficient in relating salamander populations to environmental variables. In future sampling, strategic use of capture-recapture to verify consistency of p's among sites may be a reasonable compromise between the possibility of bias in estimation of population size and deficiencies due to inefficiency associated with the estimation of p. The streamside two-lined salamander (Eurycea bislineata) was surveyed using four methods: leaf litter refugia bags, 1 m2 quadrats, 50 × 1 m visual encounter transects, and electric shocking. Comparison of survey methods at nine streams revealed congruent patterns of abundance among sites, suggesting that relative bias among the methods is similar, and that choice of survey method should be based on precision and logistical efficiency. Redback and two-lined salamander abundance were not significantly related to soil or water pH, respectively.  相似文献   

2.
The present work revealed that salinity, water temperature, and food availability were the most crucial factors affecting the abundance of larvae and their settlement as macrofouling community in the coastal waters of Kalpakkam. Quantitative as well as qualitative results showed that late post-monsoon (April–May) and pre-monsoon (June–September) periods were found to be suitable periods for larval growth, development, and survival to adult stages for most of the organisms. Clustering of physico-chemical and biological (including larval and adult availability) data yielded two major clusters; one formed by northeast (NE) monsoon months (October–January) and the other by post-monsoon/summer (February–May) months, whereas; pre-monsoon months (June–September) were distributed between these two clusters. Among all the major macrofouler groups, only bivalves established a successful relationship between its larval abundance and adult settlement. Principal component analysis indicated good associations of bivalve larvae with polychaete larvae and adult bivalves with adult barnacles. However, biotic relation between ascidians and bryozoans was observed both in the larval as well as adult community.  相似文献   

3.
In this study, variance analysis technique on unbalanced data was examined, and in this sense, Type II (fitting constants) methods were studied. The aim of this study was to show that meaningful evaluations can be performed even in unbalanced conditions and to contribute to the present investigations in biological area. In the implementation part of the study, the juvenile leaf densities of Posidonia oceanica—which is a sea grass that grows in Izmir Bay, and has very important ecological effects—in various regions and in various depths were determined. The results revealed that depth affect number of juvenile leaf (d.f.?=?3, F?=?523.90, R 2?=?0.998, p?F?=?41.53, p?F?=?19.65, p?p?p?p?p?相似文献   

4.
A survey of the crown status of Turkey oak Quercus cerris L.) trees in the boron-rich area atTravale (Southern Tuscany, Italy) was carried outin order to evaluate the impact ofgeothermal power plants. Crown thinness was assessed andmorphological and chemical tests werecarried out on leaf samples. Leaf area and dry weight weredetermined as morphological parameters;while the chemical measurements performed included nitrogenand potassium (among the nutrients),and sulphur, boron, arsenic and mercury (among the elements ofgeothermal origin). Acute damagewas found only in the area immediately adjacent to the outletsand is the result of the action of boron;crown thinness, on the other hand, is affected by the natureof the geological substrate. High quantitiesof sulphur were found in leaves throughout the survey area,due both to the availability of this elementin the geopedological substrate and to the atmospheric inputof geothermal H2S. The leafcontent of this element correlates negatively with thedistance from the power plants. Boron andarsenic are the other geothermal origin elements most commonlyfound in plant matrices. The presenceof these two elements is associated with leaf area reductionand/or an increase of specific dry weight.The most significant impact on the environment appears to beexerted by the southernmost powerplant, where there is an unfavourable ratio between quantityof emissions and height of the chimneys.  相似文献   

5.
The region of Sierra de la Ventana is located in the southwest of Buenos Aires Province, Argentina. Traditionally, this area has been devoted to livestock and agriculture, but tourism has had a significant development in recent years. In the region, there are many rivers and streams that are used for swimming and bathing. A survey of the occurrence of Shiga toxin-producing Escherichia coli (STEC) in these waters was conducted, and the microbiological quality of rivers and streams was investigated. No E. coli O157 was recovered by immunomagnetic separation. Nevertheless, the Shiga toxin gene, exclusively stx2 genotype, was detected in four non-O157 E. coli strains. Two STEC strains carried eae factor, but none of them harbored the EHEC-hlyA gene. Three of the STEC isolates belonged to samples obtained in the warm months, and one to the winter sampling. In the sample sites where STEC strains were isolated the counts of E. coli/100 ml exceeded or were close to the limit recommended by the United States Environmental Protection Agency for bathing water. The relationship observed between the rainy season and E. coli counts suggests that among the main causes for the hygienic indicator increase is the runoff of manure deposited on soils that may also induce the entrance of pathogens into the aquatic environment. This research, the first reporting STEC isolation from recreational waters in this area, revealed that streams and rivers from a beef-producing area of Argentina are a reservoir of STEC strains.  相似文献   

6.
Amphibians may be useful indicators of biological condition in small streams so determining which sampling technique maximizes encounters at the least cost and at the optimal time of year is important. Area constrained surveys (ACS), used by the Maryland Biological Stream Survey, were tested against cover board surveys, drift fences with pitfall and funnel traps, quadrat leaf litter searches, and leaf litter bags. Sixteen, 100 m-long sites were established in headwater streams in the Savage River State Forest in Garrett County, Maryland. Each technique was randomly assigned to a 25 m stream section within each overall sampling site, and sites were sampled once each month from May to October (2005) with additional sampling in March and April (2006). Area constrained surveys yielded means of 2.7 taxa and 14.9 total individuals per sampling visit, which was significantly higher than the yield of all other methods in all months except October and March, when yields were low for all techniques. Area constrained surveys were also significantly more cost-effective per taxon and per individual compared to all other methods. September produced the most taxa and individuals, October and March produced the least, and yields for April through August were similar to September. We employed removal sampling at four sites in April 2006, but abundance could not be estimated because a significant linear decrease in the accumulated catch versus catch per unit effort did not occur for three of the sites.  相似文献   

7.
Patchiness is a typical property of water quality in lakes. However, in conventional water quality monitoring, patchiness is usually too expensive to take into account, due to the high number of required samples. This study examines a feasible methodology developed for estimating the representativeness of discrete chlorophyll a measurements. Four spatially extensive data sets were collected from the Enonselkä basin of Lake Vesijärvi in Southern Finland, using a flow trough system with a fluorometer in a moving boat. Data sets were used to estimate (1) the spatial representativeness of discrete sampling; (2) the effect of varying sample size on the detected mean chlorophyll a concentration and on the observed proportion of variance. Spatial representativeness was assessed using semivariogram analysis. Results indicate that the spatial representativeness of discrete sampling can remain undesirably low. Furthermore, in monitoring programs involving just one or only a few samples, there is a significant risk of obtaining a false estimate for the mean value and variance of chlorophyll a concentration over the whole monitoring area.  相似文献   

8.
We assessed the incidence of faecal-indicator bacteria in Tyume River over a 12-month period between August 2010 and July 2011. Total coliforms, faecal coliforms and enterococci were determined by the membrane filtration method. Total coliforms were detected in counts ranging from 2.1?×?102 to 3.4?×?104?CFU/100 ml. Faecal coliform counts ranged from 1?×?102 to 1.6?×?104?CFU/100 ml while enterococci counts were in the range of 3.3?×?101 to 5.1?×?103?CFU/100 ml. Indicator bacteria counts increased from upstream to downstream sampling sites. Counts of indicator bacteria at all sites were significantly affected by seasonal changes. The bacteriological qualities of the river water were poor, exceeding the guideline of 200 CFU/100 ml and 33 CFU/100 ml for faecal coliforms and enterococci, respectively, for recreational water. Faecal coliform counts also exceeded the 1,000 CFU/100 ml guideline for water used in fresh produce irrigation. Microbial source tracking results showed that faecal pollution was predominantly of human origin during spring at all sampling sites. During other seasons, human faecal pollution was largely confined to midstream and downstream sampling sites. Generally, the presence of faecal-indicator bacteria in the river water samples suggests faecal pollution of this freshwater resource, raising the possibility of the presence of pathogenic microorganisms in the water and a threat to public health.  相似文献   

9.
Forty-four water samples from eleven sampling points were collected from four highly polluted rivers of northern India once in each four seasons during 1988–1989. The samples were analyzed for phenol, chlorophenols, a few bromophenols and other organics. Phenol was found to be absent in all the analyzed samples. Trichlorophenol and pentachlorophenol were frequently detected. Comparatively, the Ganges river was most polluted at Kannauj followed by Narora, Kachala and Fatehgarh. Maximum phenols were found at Mathura downstream of the Yamuna river followed by Mathura upstream, Okhla, ITO and none at Wazirabad. No phenols were detected in the water of the rivers Hindon and Kali at Ghaziabad and Aligarh, respectively. Some other organic pollutants were also identified by their mass spectra and supported by data from the computerized library, but, not quantified.To whom correspondence should be addressed.  相似文献   

10.
Molecular techniques have clear value for community characterization; however, almost all previous datasets are based upon non-molecular measurements and it is hard to compare "old" data with "new" data because few correlations have been made. Therefore, the purpose of this evaluation was to simultaneously use molecular and non-molecular methods within the same sampling program to determine how data compare. Three methods were used for characterizing microbial populations in Lake 260 (L260) at Experimental Lakes Area (Ontario, Canada) during a whole-lake exposure study. Methods included whole-cell microscopic counts (for bacteria, cyanobacteria, algae and zooplankton), chlorophyll a, and small sub-unit (ssu)-rRNA hybridization using EUB-338, EUB-785, CYAN-785-a/b, EUCA-1379 and UNIV-1390 gene probes. Strong correlations were found between the EUB-785 probe signal and "bacteria minus cyanobacteria" direct counts, and the EUB-338 probe signal and "bacteria plus cyanobacteria" counts. Furthermore, the difference in probe signal between EUB-338 and EUB-785 (a presumptive signature for cyanobacteria and plastids) correlated with cyanobacterial direct counts and also with chlorophyll a. However, EUCA-1379 probe signal did not correlate with algae counts, and UNIV-1390 probe signal only correlated with total bacteria counts. Results suggest that, although ssu-rRNA methods are fast, reproducible, and specifically detect "viable" organisms, their use may be limited to non-eukaryotic populations unless new probes are developed that are more specific.  相似文献   

11.
Fipronil termiticide belongs to phenyl-pyrazole class of chemical compounds. It has broad-spectrum activity particularly against house hold pests such as cockroaches, mosquitoes, locusts, ticks, and fleas at both larval and adult stages. At high dosage it can be used to control subterranean termites in building foundations. To evaluate long term efficacy against termites the persistence and vertical distribution of fipronil was studied under natural weather conditions of Dehradun, India. Fipronil was applied at four concentrations i.e. 0.05, 0.1, 0.25 and 0.5% a.i ha−1 by drenching 17 × 17 in.2 plot prepared as per modified ground board test. Soil samples were collected after 22, 38 and 56 months of treatment up to the depth of 75 cm. The soil core was cut into five distinct sections i.e. 0–15, 15–30, 30–45, 45–60 and 60–75 cm depth. The residues were extracted by shaking 20 g soil sample with acetone. The acetone extract was concentrated and cleaned-up over florisil column. Fipronil residues were estimated on GLC at 220, 260, and 300°C oven, injector and detector temperature respectively. Fipronil was found to persist beyond 56 months after application. Two metabolites viz. desulfinyl and sulfide-fipronil were detected in sampling after 22 months of application that also dissipated with time. Fipronil residues were found up to 60 cm depth. The residues in deeper layers dissipate slowly with time and after 56 months of treatment residues were detected only up to 30 cm depth.  相似文献   

12.
Environmental assessment studies often evaluate the effectiveness of drainage culverts as habitat linkages for species, however, the efficiency of the sampling designs and the survey methods are not known. Our main goal was to estimate the most cost-effective monitoring method for sampling carnivore culvert using track-pads and video-surveillance. We estimated the most efficient (lower costs and high detection success) interval between visits (days) when using track-pads and also determined the advantages of using each method. In 2006, we selected two highways in southern Portugal and sampled 15 culverts over two 10-day sampling periods (spring and summer). Using the track-pad method, 90% of the animal tracks were detected using a 2-day interval between visits. We recorded a higher number of crossings for most species using video-surveillance (n = 129) when compared with the track-pad technique (n = 102); however, the detection ability using the video-surveillance method varied with type of structure and species. More crossings were detected in circular culverts (1 m and 1.5 m diameter) than in box culverts (2 m to 4 m width), likely because video cameras had a reduced vision coverage area. On the other hand, carnivore species with small feet such as the common genet Genetta genetta were detected less often using the track-pad surveying method. The cost-benefit analyzes shows that the track-pad technique is the most appropriate technique, but video-surveillance allows year-round surveys as well as the behavior response analyzes of species using crossing structures.  相似文献   

13.
Spatial heterogeneity of the Rapel reservoir surface waters is analyzed through Landsat images. The image digital counts are used with the aim or developing an aprioristic quantitative sample design.Natural horizontal stratification of the Rapel Reservoir (Central Chile) is produced mainly by suspended solids. The spatial heterogeneity conditions of the reservoir for the Spring 86-Summer 87 period were determined by qualitative analysis and image processing of the MSS Landsat, bands 1 and 3. The space-time variations of the different observed strata obtained with multitemporal image analysis.A random stratified sample design (r.s.s.d) was developed, based on the digital counts statistical analysis. Strata population size as well as the average, variance and sampling size of the digital counts were obtained by the r.s.s.d method.Stratification determined by analysis of satellite images were later correlated with ground data. Though the stratification of the reservoir is constant over time, the shape and size of the strata varys.  相似文献   

14.
Michigan water quality standards for public bathing beaches require local health departments to collect and analyze a minimum of three water samples for Escherichia coli during each sampling event. The geometric mean number of E. coli colonies is then compared to the 300 colonies per 100 ml standard to determine compliance. This article compares the results of the currently mandated procedure to a composite sampling method, whereby the three samples are mixed in equal volumes and analyzed once. This effectively replaces the geometric mean of the individual sample results with an arithmetic mean. Although arithmetic means are more affected by outliers, this sensitivity to high concentrations is more health conservative than the geometric mean. During the 2007 sampling season, nine bathing beaches were monitored once each week. Three individual point samples and a composite sample were analyzed for each sampling event. No statistically significant differences in bacteria concentrations were found between composite sample analysis and the arithmetic mean of individual point sample analyses. No violations were detected in the 2007 sampling season, so using historical data, a retrospective analysis was performed on samples gathered at nine bathing beaches in Kalamazoo County, Michigan during the years 2001–2007. The arithmetic mean of the three samples taken at each site served as a surrogate composite sample. The benefits of compositing the three samples were investigated assuming a 2/3 reduction in analytical costs. In the traditional sampling method, three individual samples were obtained and analyzed once in every 3-week period during the summer season, whereas compositing was simulated by taking the arithmetic mean of each week’s results. The results of this retrospective cost analysis indicates that ten to 14 violations would have been missed using the less frequent traditional sampling and analysis methodology. Composite sampling is a cost-saving alternative to traditional sampling techniques that can be more protective of public health, particularly when the savings are applied to increased numbers of samples in time or space.  相似文献   

15.
Transport of contaminated sediments from a former radiological settling pond results in the deposition of U and Ni in the Lower Tims Branch (LTB)(Aiken, SC, USA). Uranium is unavailable for plant uptake, but elevated U and Ni concentrations associated with foliage of understory plants suggested mass loading. Mass loading of contaminated soil on Andropogon elliottii Chapman (Poaceae) was investigated using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The technique allows for rapid quantitative elemental depth profiling. Fresh washed and unwashed leaves (n= 5) from the contaminated area were compared with those from an uncontaminated area, analysing Ni and U at ten randomly chosen points on each leaf. Nickel and U concentrations differed significantly between washed and unwashed leaves from LTB. Particles on unwashed leaves measured up to 300 [micro sign]m in diameter, and were enriched with U. Uranium was detected on the surface of the leaf, whereas Ni was detected within leaf tissues. In unwashed LTB leaves, Ni and U concentrations did not significantly differ in areas with and without visible particles, suggesting that there were much smaller particles, indistinguishable at [times]100 magnification, which contributed to the overall metal burden. Washing removed the majority of the Ni and U on the surface, but residual U and Ni was detected. Irregularities in the leaf surface, such as scars from herbivory contained elevated U concentrations despite a washing step, presumably from trapping soil particles. Laser ablation ICP-MS revealed that mass loading makes a significant contribution to the contaminant burden of understory plants at LTB.  相似文献   

16.
Fifty seven isolates of thermotolerant E. coli were recovered from 188 drinking water sources, 45 (78.9%) were typable of which 15 (26.3%) were pathogenic serotypes. Pathogenic serogroup obtained were 04 (Uropathogenic E. coli, UPEC), 025 (Enterotoxigenic E. coli, ETEC), 086 (Enteropathogenic E. coli, EPEC), 0103 (Shiga-toxin producing E. coli, STEC), 0157 (Shiga-toxin producing E. coli, STEC), 08 (Enterotoxigenic E. coli, ETEC) and 0113 (Shiga-toxin producing E. coli, STEC). All the pathogenic serotypes showed resistance to bacitracin and multiple heavy metal ions. Resistance to streptomycin and co-trimazole was detected in two strains whereas resistance to cephaloridine, polymixin-B and ampicillin was detected in one strain each. Transfer of resistances to drugs and metallic ions was observed in 9 out of 12 strains studied. Resistances to bacitracin were transferred in all nine strains. Among heavy metals resistance to As3+ followed by Cr6+ were transferred more frequently.  相似文献   

17.
Concentrations of six endocrine-disrupting compounds (EDCs), bisphenol A (BPA), estrone (E(1)), 17β-estradiol (E(2)), estriol (E(3)), 17α-ethynylestradiol (EE(2)) and diethylstilbestrol (DES), were assessed in influents, effluents and excess sludge in ten municipal wastewater treatment plants (WWTPs) in the Three Gorges Reservoir (TGR) area, Chongqing, China. Three types of activated sludge treatment processes, oxidation ditch (OD), reversed anaerobic-anoxic-oxic (rA(2)/O) technology and sequential batch reactor (SBR), were used in the surveyed WWTPs. These WWTPs were all combined landfill leachate-sewage treatment plants. All analytes were extracted by solid-phase extraction (SPE) in the dissolved phase and by accelerated solvent-based extraction (ASE) in sludge. Gas chromatography-mass spectrometry (GC-MS) was employed for the analysis of EDCs. Among these EDCs, BPA was the most frequently detected and abundant compound (100.0-10566.7 ng L(-1), 15.5-1210.7 ng L(-1) and 85.0-2470.4 ng g(-1) with respect to the influents, effluents and excess sludge samples). The greatest levels of steroidal estrogens in municipal influents were observed in E(3) which were all >100 ng L(-1), followed by E(1) (42.2-110.7 ng L(-1)) and E(2) (7.4-32.7 ng L(-1)), and in the effluents and sludge were E(1) > E(3) > E(2) which were all <31 ng L(-1) and 105 ng g(-1), respectively. Regarding synthetic estrogens, EE(2) was frequently detected in the influents, occurring below 50 ng L(-1), while DES was not detected at all. A high correlation coefficient was observed between the leachate-sludge ratio and concentrations of influent EDCs, and it was statistically significant (i.e., R > 0.65, P < 0.05), but removal efficiency of the EDCs did not show significant differences with OD, rA(2)/O and SBR processes. Furthermore, modification of treatment technology as well as operational parameters, such as hydraulic retention time (HRT), sludge retention time (SRT) and disinfection process (DP), were recommended to further eliminate the residual EDCs.  相似文献   

18.
Urban household kitchen environment was assessed for safety by determining their levels of indicator bacteria, hygienic habits and risk of cross-contamination. Household kitchens (60) were selected in Warri Town, Nigeria, by the multi-stage sampling technique. Contact surfaces, water and indoor kitchen air were analysed for aerobic plate counts, total and faecal coliforms using Nutrient and McConkey media by swab/rinse method, membrane filtration and sedimentation methods, respectively. Hygienic habits and risk of cross-contamination were assessed with structured questionnaire which included socio-demographic variables. On the basis of median counts, the prevalence of high counts (log cfu/cm2/m3/100 mL) of aerobic plate counts (>3.0), total coliforms (>1.0) and faecal coliforms (>0) on contact surfaces and air was high (58.0–92.0%), but low in water (30.0–40.0%). Pots, plates and cutleries were the contact surfaces with low counts. Prevalence of poor hygienic habits and high risk of cross-contamination was 38.6 and 67.5%, respectively. Education, occupation and kitchen type were associated with cross-contamination risk (P = 0.002–0.022), while only education was associated with hygienic habits (P = 0.03). Cross-contamination risk was related (P = 0.01–0.05) to aerobic plate counts (OR 2.30; CL 1.30–3.17), total coliforms (OR 5.63; CL 2.76–8.25) and faecal coliforms (OR 4.24; CL 2.87–6.24), while hygienic habit was not. It can be concluded that urban household kitchens in the Nigerian setting are vulnerable to pathogens likely to cause food-borne infections.  相似文献   

19.
This study analysed airborne pollen counts for allergenic herb taxa in Toledo (central Spain), a major tourist city receiving over 2 million visitors per year, located in the region of Castilla-La Mancha. The taxa selected were Chenopodiaceae–Amaranthaceae, Plantago, Poaceae and Urticaceae, all of which produce allergenic pollen giving rise to serious symptoms in pollen-allergy sufferers. Aerobiological data were recorded over a 6-year period (2005 to 2010) using the sampling and analysis procedures recommended by the Spanish Aerobiology Network. The abundance and the temporal (annual, daily and intradiurnal) distribution of these pollen types were analysed, and the influence of weather-related factors on airborne pollen counts was assessed. Pollen from herbaceous species accounted for 20.9% of total airborne pollen in Toledo, the largest contributor being Poaceae, with 8.5% of the total pollen count; this family was also the leading cause of respiratory allergies. Examination of intradiurnal variation revealed three distinct distribution patterns: (1) peak daily counts for Chenopodiaceae–Amaranthaceae and Plantago were recorded during the hottest part of the day, i.e. from 1400 to 1600 hours; (2) Urticaceae displayed two peaks (1400–1600 and 2200 hours); and (3) Poaceae counts remained fairly stable throughout the day. Two main risk periods were identified for allergies: spring, with allergies caused by Urticaceae, Plantago and Poaceae pollen, and summer, due to Chenopodiaceae–Amaranthaceae pollen.  相似文献   

20.
In this study, the integration of a high volume, portable aerosol-to-hydrosol sampling technique and quantitative polymerase chain reaction (qPCR) was investigated for bioaerosol monitoring by adapting the RCS High Flow to sample air with mineral-oil-strips. Bacillus subtilis var niger and Pseudomonas fluorescens were aerosolized and collected by the RCS High Flow loaded with mineral-oil-strips for 1, 2 and 5 min. In addition, the adapted aerosol-to-hydrosol sampler was also tested for sampling environmental bacterial aerosols in four different environments (a back yard, a student dorm, a dining hall, and a play ground). The performances of the RCS High Flow with mineral-oil-strips were compared with the use of agar strips under similar conditions in all experiments. Air samples collected by the RCS High Flow were cultured, and in addition those collected with mineral-oil-strips were also quantified using qPCR. When sampling B. subtilis var niger aerosols, the use of mineral-oil-strips was shown to report significantly higher culturable concentrations than those obtained by agar strips regardless of the sampling time tested (p-value = 0.04). In contrast, the differences between the two methods when sampling P. fluorescens aerosols were not statistically significant (p-value = 0.5). When coupled with qPCR, the RCS High Flow loaded with mineral-oil-strips obtained significantly higher bacterial aerosol concentrations than those detected by the culturing method. The sampling time was observed to have negligible effects on the efficiency of the technology developed here. When sampling in different environments, the use of mineral-oil-strip was observed to yield significantly higher, about 4-12 times, culturable bacterial aerosol concentration levels compared to the use of agar. This study demonstrated a high volume (100 L min?1) portable aerosol-to-hydrosol sampling technique, holding broad promise in monitoring airborne biological threats when coupled with qPCR technology. Yet, caution should be taken in relating the bioaerosol concentrations to health risks as qPCR detects both culturable and non-culturable cells including inactivated ones.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号