首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Continuous, intermittent and passive sampling of airborne VOCs   总被引:1,自引:0,他引:1  
Long sampling periods are often advantageous or required for measuring air quality and characterizing exposures. However, sampling periods exceeding 8 to 24 h using thermally desorbable adsorbent tube (TDT) samplers for the measurement of airborne volatile organic compounds (VOCs) face several challenges, including maintaining stable and low flow rates, and avoiding breakthrough of the adsorbent. These problems may be avoided using intermittent sampling; however, the literature contains few if any reports that have evaluated this technique in environmental, occupational or other applications. The purpose of this study is to evaluate continuous, intermittent and passive sampling methods using both laboratory and real-world tests. Laboratory tests compared continuous and intermittent (active) samplers in a controlled dynamic test gas generation system. Field tests used side-by-side active and passive samplers in an office, home workshop and four smokers' homes. All samples were analyzed for a wide range of VOCs by GC-MS. In most instances, intermittent sampling yielded better reproducibility (duplicate precision of 10 +/- 6%) than continuous low-flow sampling (18 +/- 5%), in part due to difficulty maintaining low flows. Concentrations obtained using intermittent sampling agreed with those for continuous sampling, with downward biases resulting primarily from errors in flow rate measurements. In the field, more VOC species were detected using active rather than passive sampling. Passive measurements were 12% lower than continuous measurements, a difference attributed to declining uptake rates at higher concentrations over the 3 to 4 d sampling period. Overall, most measurements obtained using the three sampling methods agreed within 20% for a wide range of concentrations (0.1 to 230 microg m(-3)). Both passive and intermittent sampling approaches are suitable for long sampling periods, but intermittent sampling provides greater flexibility with respect to sampling period, and permits the use of multi-bed adsorbents that can capture a wider range of VOCs.  相似文献   

2.
While air sampling techniques using adsorbent-based collection, thermal desorption and chromatographic analysis have found a niche in ambient air sampling, occupational applications have been more limited. This paper evaluates the use of thermal desorption techniques for low flow active and passive sampling configurations which allow conveniently long duration sampling in occupational settings and other high concentration environments. The use of an orifice enables flows as low as 0.5 ml min(-1) and sampling periods up to several days without significant biases. A model is used to predict sampling rates of a passive sampler encompassing an orifice, a void space, glass wool, and the adsorbent. Laboratory and field tests conducted at a commercial offset printing facility, which contained a variety of volatile organic compounds (primarily aromatic but also a few chlorinated and terpene compounds at levels from 1 to 67,000 microg m(-3)), are used to evaluate the approach. Tenax GR and Carbosieve SIII, both singly and together, were employed as adsorbents. Side-by-side tests comparing high flow, low flow and passive samplers show excellent agreement and high linearity (r = 0.95) for concentrations spanning nearly five orders of magnitude. Active samplers were tested at flows as low as 0.5 ml min(-1), compared to typical flows up to 40 ml min(-1). Passive samplers demonstrated a linear range and agreement with predictions for adsorbate loadings from approximately 1 ng to nearly 10 microg. Using a chemical mass balance receptor model, concentrations in the facility were apportioned to solvents, inks and other indoor and outdoor sources. Overall, the use of low flow active and passive sampling approaches employing thermal desorption techniques provides good performance and tremendous flexibility that facilitates use in many applications, including workplace settings.  相似文献   

3.
The cyanobacterial toxins, nodularin and microcystin, are highly efficient inhibitors of cellular protein phosphatases. Toxicity primarily evolves following ingestion of cyanobacterial material or toxins and results in liver and renal pathology. Ingestion is the main route of exposure in the World Health Organizations current risk assessment of nodularin and microcystins. Nasally applied microcystin appears to have a 10-fold higher availability and toxicity than orally ingested toxins, suggesting that aerosolized toxins could represent a major risk for human populations close to lakes with cyanobacterial blooms. In this study, nodularin and microcystin levels in aerosols were assessed using high and low volume air samplers for 4, 12 and 24 h periods at lakes Forsyth and Rotorua (South Island, New Zealand). These lakes were experiencing blooms of Nodularia spumigena and Microcystis sp., respectively. Using the high volume samplers up to 16.2 pg m(-3) of nodularin and 1.8 pg m(-3) of microcystins were detected in the air. Aerosolized nodularin and microcystins do not appear to represent an acute or chronic hazard to humans. The latter was concluded based on calculations using average human air intakes, the highest nodularin or microcystin concentrations measured in the air in this study, and assuming inhalatory toxicities comparable to toxicological data obtained following intraperitoneal applications in mice. However, as the toxin concentrations in the air were calculated over extended sampling periods, peak values may be underestimated. Aerosolized toxins should be considered when developing risk assessments particularly for lakeside populations and recreational users where inhalation of cyanotoxins may be a secondary exposure source to a primary oral exposure.  相似文献   

4.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

5.
Ambient ammonia concentrations, mainly originating from agricultural activities, have increased in the last few decades in Europe. As a consequence, critical loads on oligotrophic ecosystems such as forests and mires are greatly exceeded. Monitoring of ambient ammonia concentrations is necessary in order to investigate source-receptor relationships. Measuring ambient ammonia concentrations continuously with high time resolution is very expensive and cost-efficient systems are required. Where time resolution is of minor importance, several cost-effective systems, mainly dry denuder and passive samplers, can be applied. In this paper the Zürcher passive sampler, a diffusive sampling system, is presented. It is a Palmes type sampler with an acidic solution as absorbent and is easy to handle. It was tested at 46 sites in Switzerland over one year. The average concentration in ambient air was 2.5 microg m(-3) +/- 0.4 microg m(-3). The average of the blank values were 0.21 microg m(-3). The detection limit (double the standard deviation of the blank values) was 0.36 microg m(-3). Three passive samplers were exposed at each site and each period. The mean standard deviation of these triplicate measurements was 9.5%. Compared with a discontinuous tubular denuder system and a continuous annular denuder system, the deviation was less than 10%. The Zürcher passive sampler is a useful and cost-efficient tool to determine long-term average ammonia concentrations (one- to four-week periods) in ambient air for mean concentrations above 1 microg m(-3).  相似文献   

6.
Diffusive sampling of Volatile Organic Compounds (VOCs) onto thermal desorption tubes, followed by gas chromatography, is an established technique for area or personal monitoring of typical workplace concentrations and there has been increasing interest in extending the application to environmental levels, particularly for benzene, toluene and xylene (BTX). Diffusive sampling rates for BTX on Chromosorb 106 and Carbograph-1 (a graphitised carbon) were measured over periods of 1-4 weeks in field validation experiments using ambient air and parallel pumped sampling (the reference method) at the HSL site in central Sheffield. The reference method was also used to investigate the possible bias of an open-path spectrophotometer (OPSIS) used by Sheffield City Council. A bias for BTX was suspected from results of a two-week initial exercise in which several diffusive samplers were placed close to the light path. In the full field validation of the diffusive samplers carried out subsequently, the significant bias of BTX concentrations reported by OPSIS were confirmed when compared with concurrent results from the reference method. OPSIS gave benzene and toluene values up to eight times higher than expected from the GC measurements. Xylene discrepancies were smaller, but in one 3-day peak episode, OPSIS demonstrated a negative correlation with GC.  相似文献   

7.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

8.
The development of convenient and competitive devices and methods for monitoring of organic pollutants in the aquatic environment is of increasing interest. An integrative passive sampling system has been developed which consists of a solid poly(dimethylsiloxane) (PDMS) material (tube or rod), acting as hydrophobic organic receiving phase, enclosed in a water-filled or an air-filled low-density polyethylene (LDPE) membrane tubing. These samplers enable the direct analysis of the pollutants accumulated during exposure in the receiving phase by thermodesorption-GC/MS, avoiding expensive sample preparation and cleanups. The capabilities of these sampling devices were studied for the sampling of 20 persistent organic pollutants (chlorobenzenes, hexachlorocyclohexanes, p,p'-DDE, PAHs, and PCBs) in laboratory exposure experiments. For the three sampler designs investigated the uptake of all target analytes was integrative over exposure periods up to 9 days (except PCB 101). The determined sampling rates range from 4 to 1340 microl h(-1) for the water-filled samplers and from 20 to 6360 microl h(-1) for the air-filled ones, respectively. The sampling rate of the analytes is dependent on their molecular weight, partition between water and sampler media (PDMS, polyethylene, water, air) and also of the sampler design. The passive samplers enable the estimation of time-weighted average (TWA) concentration of water pollutants in the lower ng l(-1) to pg l(-1) range.  相似文献   

9.
The effect of different sampling exposure times and ambient air pollutant concentrations on the performance of Radiello? samplers for analysis of volatile organic compounds (VOCs) is evaluated. Quadruplicate samples of Radiello? passive tubes were taken for 3, 4, 7 and 14 days. Samples were taken indoors during February and March 2010 and outdoors during July 2010 in La Canonja (Tarragona, Spain). The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detection (MS). The results show significant differences (t-test, p < 0.05) between the amounts of VOCs obtained from the sum of two short sampling periods and a single equivalent longer sampling period for 65% of all the data. 17% of the results show significantly larger amounts of pollutant in the sum of two short sampling periods. Back diffusion due to changes in concentrations together with saturation and competitive effects between the compounds during longer sampling periods could be responsible for these differences. The other 48% of the results that are different show significantly larger amounts in the single equivalent longer sampling period. The remaining 35% of the results do not show significant differences. Although significant differences are observed in the amount of several VOCs collected over two shorter sampling intervals compared to the amount collected during a single equivalent longer sampling period, the ratios obtained are very close to unity (between 0.7 and 1.2 in 75% of cases). We conclude that Radiello? passive samplers are useful tools if their limitations are taken into account and the manufacturer's recommendations are followed.  相似文献   

10.
A pilot study is presented evaluating selected chlorinated pesticides as chemical tracers for water masses in a sub-Arctic fjord system (Godth?bsfjord, western Greenland). Polyoxymethylene (POM) based passive water samplers were deployed during summer-autumn 2010. The levels of the analysed chlorinated pesticides in the fjord surface waters were found to be low compared to earlier studies. α-Hexachlorocyclohexane (α-HCH) and hexachlorobenzene (HCB) were the predominant contaminants. However, these two compounds have higher levels in oceanic water compared to freshwater influenced fjord waters. These chemicals can thus be considered as indicators for direct atmospheric long-range transport, while the organochlorine pesticides like trans-, cis-chlordane, trans-nonachlor and oxychlordane that are detected in the inner parts of the fjord are indicators for potential freshwater sources such as rivers and glacial meltwater runoff (secondary sources). The average values were 50 pg L(-1) for HCB and 11 pg L(-1) for α-HCH. These concentrations are comparable to levels in fjords in Svalbard (Norwegian Arctic), but lower than in open and/or ice covered oceans in the Canadian Arctic. Two air samplers were deployed for the identification of direct atmospheric contributions. Local contamination sources do not contribute significantly. The study demonstrated the value of passive water sampling devices for comprehensive hydrological characterization of Arctic coastal waters.  相似文献   

11.
While polyurethane foam (PUF) disk passive air samplers are employed increasingly to monitor persistent organic pollutants in indoor air, they essentially sample only the vapour phase. As a previous investigation of the vapour : particle phase partitioning of hexabromocyclododecanes HBCDs in (outdoor) air reported them to be present largely in the particulate phase, we monitored three offices using active air samplers. In each, approximately 65% of HBCDs were present in the vapour phase, suggesting PUF disk passive samplers are suitable for monitoring HBCDs in indoor air. Concentrations in the three offices (239-359 pg Sigma HBCD m(-3)) exceed substantially those reported in outdoor air from the United States (2.1-11 pg Sigma HBCD m(-3)), but are in line with outdoor air from Stockholm. The relative abundance of the three principal diastereomers in office air was closer to that found in technical HBCD formulations (i.e. predominantly gamma-HBCD) than in most US outdoor air samples. Time integrated air concentrations of alpha-, beta-, and gamma-HBCD were obtained for an office using a low volume sampler operated over a 50 d period alongside PUF disk samplers. This calibration exercise yielded the following passive air sampling rates for both a fully- and part-sheltered PUF disk sampler design: for alpha-, beta-, and gamma-HBCD, 0.87, 0.89, and 0.91 m3 d(-1) respectively (fully-sheltered) and 1.38, 1.54, and 1.55 m3 d(-1) respectively (part-sheltered). Deployment of the part-sheltered configuration yielded concentrations approximately 35% lower than those obtained using a high volume sampler, consistent with PUF disk samplers measuring primarily the vapour phase.  相似文献   

12.
Five different instruments for the determination of the mass concentration of PM10 in air were compared side-by-side for up to 33 days in an undisturbed indoor environment: a tripod mounted BGI Inc. PQ100 gravimetric sampler with a US EPA certified Graseby Andersen PM10 inlet; an Airmetrics Minivol static gravimetric sampler; a Casella cyclone gravimetric personal sampler; an Institute of Occupational Medicine gravimetric PM10 personal sampler; and two TSI Inc. Dustrak real-time optical scattering personal samplers. For 24 h sampling of ambient PM10 concentrations around 10 microg m(-3), the estimated measurement uncertainty for the two gravimetric personal samplers was larger (approximately +/- 20%) compared with estimated measurement uncertainty for the PQ100/Graseby Andersen sampler (< +/- 5%). Measurement uncertainty for the Dustraks was lower (approximately +/- 15% on average) but calibration of the optical response against a reference PM10 method is essential since the Dustraks systematically over-read PM10 determined gravimetrically by a factor approximately 2.2. However, once calibrated, the Dustrak devices demonstrated excellent functionality in terms of ease of portability and real-time data acquisition. Estimated measurement uncertainty for PM10 concentrations determined with the Minivol were +/- 5%. The Minivol data correlated well with PQ100/Graseby Andersen data (r= 0.97, n = 18) but were, on average, 23% greater. The reason for the systematic discrepancy could not be traced. Intercomparison experiments such as these are essential for assessing measurement error and revealing systematic bias. Application of two Dustraks demonstrated the spatial and temporal variability of exposure to PM10 in different walking and transport microenvironments in the city of Edinburgh, UK. For example, very large exposures to PM10 were identified for the lower deck of a double-decker tour bus compared with the open upper deck of the same vehicle. The variability observed emphasises the need to determine truly personal exposure profiles of PM10 for quantifying exposure response relationships for epidemiological studies.  相似文献   

13.
The need for ambient gaseous ammonia (NH(3)) measurements has increased in the last decade as reactive NH(3) concentrations and deposition fluxes show little change even with tightening standards on nitrogen oxides (NO(x)) emissions. Currently, there are several networks developing methods for adding NH(3) measurements in the U.S. Gaseous NH(3) measurements will provide scientists and policymakers data which can be used to estimate ecosystem inputs, validate air quality models including trends and regional variability, and evaluate changes to the environment based on additional emission reduction requirements and estimates of critical nitrogen load exceedances. The passive samplers described in this paper were deployed in duplicate or triplicate and collocated with annular denuders or continuous instruments to determine their accuracy. The samplers assessed included the Adapted Low-Cost Passive High Absorption (ALPHA), Radiello(?), and Ogawa passive samplers. The median relative percent differences (MRPD) between the reference method and passive samplers for the ALPHA, Radiello(?) and Ogawa were -2.4%, -37% and -44%, respectively. The precision between duplicate samplers for the ALPHA and Ogawa samplers, was 7% and 6%, respectively. Triplicate Radiello(?) precision was assessed using the coefficient of variation (CV). The CV for the Radiello(?) samplers was 10%. This article discusses the statistical results from these studies.  相似文献   

14.
Studies on health effects of air pollutants ideally define exposure through the collection of air samples in the participants' homes. Concentrations derived from these samples are then considered as an estimate for the average concentration of air pollutants in the homes. Conclusions drawn from such studies therefore depend very much on the validity of the measured air pollution concentrations. In this paper we analysed repeated BTEX and NO(2) measurements with a time period of several months lying between the two conducted home visits. We investigated the variability of their concentrations over time by determining correlation coefficients and calculating within- and between-home variances. Our population consisted of 631 homes of participants from two cohort studies within the framework of the German study on Indoor Factors and Genetics in Asthma. Air pollutants were measured using passive samplers both indoors and outdoors. The measured BTEX concentrations were poorly correlated, with Pearson's correlation coefficient r ranging from -0.19 to 0.27. Additionally, a considerable seasonal effect could be observed. A higher correlation was found for the NO(2) concentrations with r ranging between 0.24 and 0.55. For the BTEX, the between-home variance was bigger than the within-home variance, for NO(2) both variances were of about the same order. Our results indicate that in a setting of moderate climate like in Germany, the variability of BTEX and NO(2) concentrations over time is high and a single measurement is a poor surrogate for the long-term concentrations of these air pollutants.  相似文献   

15.
The Building Research Establishment (BRE) has been using diffusive samplers for the study of VOCs in indoor and outdoor air since 1989. The Perkin Elmer type sampler packed with Tenax TA adsorbent is used for the diffusive sampling of C6-C16 organic compounds. This method was applied in a major study of relationships between the environment and child health carried out during 1990-1993 in the Avon area of the UK. The present paper reports results of an investigation into the repeatability of the sampler in outdoor air and measurements of 6 aromatic hydrocarbons inside and outside a home over a 5 year period and inside and outside an office building over a 12 month period. Both the home and the office were located in Hertfordshire, England. Concentrations of VOCs recorded are similar to those found in the Avon area. Higher concentrations of each of the six compounds were recorded inside the home than outside, whilst greater amounts of benzene and toluene were found inside the office than outside. Seasonal variations in concentrations are observed and measurements recorded outdoors are similar to those recorded by other workers.  相似文献   

16.
The spatial and temporal variations of PM(2.5), PM(10) and TSP in three African cities of different sizes (Dar es Salaam, Ouagadougou and Gaborone) were investigated using portable particle counters. Three different areas (downtown, green residential and traditional residential) and a reference site were designated in each of the cities in order to detect intra-urban and temporal variability. Morning, noon and night measurements were conducted in the urban areas while observations at reference stations were made continuously over the field periods. A clear diurnal pattern in particle concentrations was found in inland Gaborone and Ouagadougou, with morning and night peaks where the latter was the highest. However, in coastal Dar es Salaam the night peak was almost absent due to delayed stabilisation of the air. Particle concentrations at the Ouagadougou reference station were extreme. The direct contribution of vehicle emissions are of secondary importance since the PM(2.5)/PM(10) ratios are low (0.1-0.3). Much of the particles are supposed to be soil particles that are entrained in the air by daytime high windspeeds followed by nighttime subsidence as the air is stabilised and windspeed decreases. However, in all three cities, resuspension are important as areas with a network of unpaved roads showed the highest concentrations of suspended particles. Generally, the central business district had the lowest concentrations of particulate matter.  相似文献   

17.
Daily PM10 concentrations were measured at four sampling stations located in Chiang Mai and Lamphun provinces, Thailand. The sampling scheme was conducted during June 2005 to June 2006; every 3 days for 24 h in each sampling period. The result revealed that all stations shared the same pattern, in which the PM10 (particulate matters with diameter of less than 10 microm) concentration increased at the beginning of dry season (December) and reached its peak in March before decreasing by the end of April. The maximum PM10 concentration for each sampling station was in the range of 140-182 microg/m(3) which was 1.1-1.5 times higher than the Thai ambient air quality standard of 120 microg/m(3). This distinctly high concentration of PM10 in the dry season (Dec. 05-Mar. 06) was recognized as a unique seasonal pattern for the northern part of Thailand. PM10 concentration had a medium level of negative correlation (r = -0.696 to -0.635) with the visibility data. Comparing the maximum PM10 concentration detected at each sampling station to the permitted PM10 level of the national air quality standard, the warning visibility values for the PM10 pollution-watch system were determined as 10 km for Chiang Mai Province and 5 km for Lamphun Province. From the analysis of PM10 constituents, no component exceeded the national air quality standard. The total concentrations of PM10-bond polycyclic aromatic hydrocarbons (PAHs) are calculated in terms of total toxicity equivalent concentrations (TTECs) using the toxicity equivalent factors (TEFs) method. TTECs in Chiang Mai and Lamphun ambient air was found at a level comparable to those observed in Nagasaki, Bangkok and Rome and at a lower level than those reported at Copenhagen. The annual number of lung cancer cases for Chiang Mai and Lamphun Provinces was estimated at two cases/year which was lower than the number of cases in Bangkok (27 cases/year). The principal component analysis/absolute principal component scores (PCA/APCS) model and multiple regression analysis were applied to the PM10 and its constituents data. The results pointed to the vegetative burning as the largest PM10 contributor in Chiang Mai and Lamphun ambient air. Vegetative burning, natural gas burning & coke ovens, and secondary particle accounted for 46-82%, 12-49%, and 3-19% of the PM10 concentrations, respectively. However, natural gas burning & coke ovens as well as vehicle exhaust also deserved careful attention due to their large contributions to PAHs concentration. In the wet season and transition periods, 42-60% of the total PAHs concentrations originated from vehicle exhaust while 16-37% and 14-38% of them were apportioned to natural gas burning & coke ovens and vegetative burning, respectively. In the dry period, natural gas burning & coke ovens, vehicle exhaust, and vegetative burning accounted for 47-59%, 20-25%, and 19-28% of total PAHs concentrations. The close agreement between the measured and predicted concentrations data (R(2) > 0.8) assured enough capability of PCA/APCS receptor model to be used for the PM10 and PAHs source apportionment.  相似文献   

18.
广东省南海市主干道气溶胶中多环芳烃(PAHs)的研究   总被引:1,自引:0,他引:1  
气溶胶采样点位于广东省南海市桂江路边缘及两侧 ,采集时间为 2 4 h,连续采集三天。使用仪器为国产大体积采样器。同时在公园内设点采样 ,以作背景研究。样品经超声波抽提和层析柱分离得到正构烷烃、芳烃 (AHs)和极性组分等三种有机组分。对 PAHs进行 GC MS分析 ,气溶胶中具有较高含量的芴、菲、蒽、荧蒽、芘、苯并 [a]蒽、、苯并 [b]荧蒽、苯并 [k]荧蒽、苯并 [a]芘、茚并 [1 ,2 ,3-cd]芘、二苯并 [a,h]蒽、苯并 [g,h,i]等。通过 TSP研究认为 ,主干道的机动车排放和扬尘是气溶胶的主要来源 ,气候改变也是 TSP变化的另一重要因素。  相似文献   

19.
The main objective of the study was to evaluate the applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide (CP) in the hospital working environment. For this purpose, air contamination of Masaryk Memorial Cancer Institute (Czech Republic) was monitored using the sampling apparatus containing the samplers described above. In addition, the surface contamination was also determined using the wipe sampling technique. During the monitoring, contamination of three different workplaces (storage room, preparation room and outpatient clinic) was studied. Using Strata X solid sorbent tubes, airborne CP was determined in all (n = 5) samples collected at the outpatient clinic over a 5 day monitoring period (concentration range: 0.3-4.3 ng m(-3)). Other samplers (including PTFE filters) did not collect any detectable amount of CP (the limit of detection, LOD ≤ 0.1 ng m(-3)). Negative results detected at filter samples indicate that CP determined at Strata X samples was most probably of gaseous origin. Surface contamination ranged from <2 to 19, <8 to 418 and 133-15,500 pg cm(-2) at the storage room, preparation room and outpatient clinic, respectively. The study showed that evaporation of antineoplastic drugs should not be neglected, albeit the concentrations determined in our study are relatively low. Therefore, proper monitoring of airborne contamination should involve simultaneous sampling of both particle-bonded and gaseous phases. In this way, Strata X sorbent tubes seem to be an effective tool for the sampling of gaseous CP in the indoor air.  相似文献   

20.
大气中痕量持久性有机污染物年均值的测定   总被引:7,自引:1,他引:6  
采用以XAD-2树脂为吸附介质的大气被动采样器,在四川卧龙自然保护区设置6个采样点,进行了为期2年(2005年-2007年)的环境大气样品采集。用气相色谱-高分辨质谱方法对HCB,HCHs,DDTs和PCBs测定。结果表明,平行样品的重现性良好,平均相对偏差为9%。POPs检测下限的范围为1.0pg/m^3-5.9pg/m^3。2年的年均值数据表现出较好的一致性和规律性。以XAD-2树脂为吸附介质的大气被动采样器能够便利地采集进而测定半年或一年污染物的平均浓度,可以经济、有效地获得大气中痕量POPs的年均值。ρ(α—HCH)/ρ(γ-HCH)从成都到卧龙的上升的趋势反映的是传输过程中HCH的降解;而卧龙地区跨年度数据所反映出的ρ(α—HCH)/ρ(γ-HCH)下降趋势,可以归因于林丹的使用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号