首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Human enteroviruses (HEVs) occur in high concentrations in wastewater and can contaminate receiving environmental waters, constituting a major cause of acute waterborne disease worldwide. In this study, we investigated the relative abundance, occurrence, and seasonal distribution of polio and other enteroviruses at three wastewater treatment plants (WWTPs) in Naples, Southern Italy, from January 2010 to December 2014. Influent and effluent samples from the three WWTPs were collected monthly. One hundred and sixty-one of the 731 wastewater samples collected (22.0%) before and after water treatment were CPE positive on RD cells; while no samples were positive on L20B cells from any WWTPs. Among the 140 non-polio enterovirus isolated from inlet sewage, 69.3% were Coxsackieviruses type B and 30.7% were Echoviruses. Among these, CVB3 and CVB5 were most prevalent, followed by CVB4 and Echo6. The twenty-one samples tested after treatment contained 6 CVB4, 5 CVB3, 3 Echo11, and 2 Echo6; while other serotypes were isolated less frequently. Data on viral detection in treated effluents of WWTPs confirmed the potential environmental contamination by HEVs and could be useful to establish standards for policies on wastewater management.  相似文献   

2.
3.
Human enteric viruses are a major cause of waterborne diseases, and can be transmitted by contaminated water of all kinds, including drinking and recreational water. The objectives of the present study were to assess the occurrence of enteric viruses (enterovirus, norovirus, adenovirus, hepatitis A and E virus) in raw and treated wastewaters, in rivers receiving wastewater discharges, and in drinking waters. Wastewater treatment plants’ (WWTP) pathogen removal efficiencies by adenovirus quantitative real-time PCR and the presence of infectious enterovirus, by cell culture assays, in treated wastewaters and in surface waters were also evaluated. A total of 90 water samples were collected: raw and treated wastewaters (treated effluents and ultrafiltered water reused for industrial purposes), water from two rivers receiving treated discharges, and drinking water. Nested PCR assays were used for the identification of viral DNA/RNA, followed by direct amplicon sequencing. All raw sewage samples (21/21), 61.9 % of treated wastewater samples (13/21), and 25 % of ultrafiltered water samples (3/12) were contaminated with at least one viral family. Multiple virus families and genera were frequently detected. Mean positive PCRs per sample decreased significantly from raw to treated sewage and to ultrafiltered waters. Moreover, quantitative adenovirus data showed a reduction in excess of 99 % in viral genome copies following wastewater treatment. In surface waters, 78.6 % (22/28) of samples tested positive for one or more viruses by molecular methods, but enterovirus-specific infectivity assays did not reveal infectious particles in these samples. All drinking water samples tested negative for all viruses, demonstrating the effectiveness of treatment in removing viral pathogens from drinking water. Integrated strategies to manage water from all sources are crucial to ensure water quality.  相似文献   

4.
Wild polioviruses still remain endemic in three countries (Afghanistan, Pakistan, and Nigeria) and re-emergency of wild polio has been reported in previously polio-free countries. Environmental surveillance has been used as a supplementary tool in monitoring the circulation of wild poliovirus (PVs) and/or vaccine-derived PVs even in the absence of acute flaccid paralysis cases. This study aimed to monitor the presence of polioviruses in wastewater samples collected at one wastewater treatment plant located in the municipality of Rio de Janeiro, Brazil. From December 2011 to June 2012 and from September to December 2012, 31 samples were collected and processed. RD and L20B cell cultures were able to isolate PVs and non-polio enteroviruses in 27/31 samples. Polioviruses were isolated in eight samples (type 1 Sabin = 1, type 2 Sabin = 5, and type 3 Sabin = 2). Vaccine-derived polioviruses were not detected nor evidence of recombination with other PVs or non-polio enterovirus serotypes were observed among the isolates. The Sabin-related serotypes 2 and 3 presented nucleotide substitutions in positions associated with the neurovirulent phenotype at the 5′-UTR. Changes in important Amino acid residues at VP1 were also observed in the serotypes 2 and 3. Environmental surveillance has been used successfully in monitoring the circulation of PVs and non-polio enteroviruses and it is of crucial importance in the final stages of the WHO global polio eradication initiative. Our results show the continuous circulation of Sabin-like PVs and non-polio enteroviruses in the analyzed area during the study period.  相似文献   

5.
Human sapoviruses were identified in 15 (12.4 %) of 121 inlet sewage samples collected from wastewater treatment plants in Naples and Palermo, Italy, in 2011. All strains, except one GI.1, were genotyped as GI.2 by sequencing a capsid gene fragment. This is the first detection of sapovirus in wastewaters in Italy.  相似文献   

6.
This study was designed to determine the quantitative polymerase chain reaction (qPCR) signal persistence of viruses in three effluent-dominated streams. Samples were collected from the effluent outfall of three wastewater treatment plants in the Western United States and downstream at different locations. All samples were tested for the presence of pepper mild mottle virus (PMMoV), adenoviruses, norovirus GI and GII, Aichi virus, and enteroviruses using qPCR. PMMoV was detected most frequently in 54/57 (94.7%) samples, followed by adenoviruses which was detected in 21/57 (36.8%) samples. PMMoV was detected at all locations downstream and up to 32 km from the discharge point. This study demonstrated that the detection signal of PMMoV was able to persist in wastewater discharges to a greater degree than human enteric viruses in effluent-dominated rivers.  相似文献   

7.
Human enteric viruses occur in high concentrations in wastewater and can contaminate receiving environmental waters. Due to the lack of data on the prevalence of enteric viruses in New Caledonia, the presence and the concentrations of enteric viruses in wastewater and seawater were determined. Untreated wastewater and seawater samples were collected monthly for 1 year from a wastewater treatment plant (WWTP) and from the WWTP’s outlet, located directly on a popular recreational beach. Samples were tested for norovirus genogroups I and II (NoV GI and GII), astroviruses (AsV), sapoviruses (SaV), enteroviruses (EV), hepatitis A viruses (HAV), rotaviruses (RoV), human adenoviruses (HAdV) and human polyomaviruses (HPyV). To support these data, faecal samples from cases of gastroenteritis were tested for the first time for NoV and detected in the population. NoV GI, NoV GII, EV, SaV, HAdV and HPyV were detected in all wastewaters, RoV in 75 % and AsV in 67 %. HAV were not detected in wastewater. Overall, 92 % of seawater samples were positive for at least one virus. HPyV were detected most frequently in 92 % of samples and at concentrations up to 7.7 × 103 genome copies/L. NoV GI, NoV GII, EV, SaV, RoV and HAdV were found in 33, 66, 41, 33, 16 and 66 % of seawater samples, respectively. AsV were not detected in seawater. This study reports for the first time the presence of NoV and other enteric viruses in New Caledonia and highlights the year-round presence of enteric viruses in the seawater of a popular beach.  相似文献   

8.
Enteric viruses transmitted via the faecal-oral route occur in high concentrations in wastewater and may contaminate drinking water sources and cause disease. In order to quantify enteric adenovirus and norovirus genotypes I and II (GI and GII) impacting a drinking source in Norway, samples of surface water (52), wastewater inlet (64) and outlet (59) were collected between January 2011 and April 2012. Samples were concentrated in two steps, using an electropositive disc filter and polyethylene glycol precipitation, followed by nucleic acid extraction and analysis by quantitative polymerase chain reaction. Virus was detected in 47/52 (90.4 %) of surface water, 59/64 (92 %) of wastewater inlet and 55/59 (93 %) of wastewater outlet samples. Norovirus GI occurred in the highest concentrations in surface water (2.51e + 04) and adenovirus in wastewater (2.15e + 07). While adenovirus was the most frequently detected in all matrices, norovirus GI was more frequently detected in surface water and norovirus GII in wastewater. This study is the first in Norway to monitor both sewage and a drinking water source in parallel, and confirms the year-round presence of norovirus and adenovirus in a Norwegian drinking water source.  相似文献   

9.
Noroviruses (NoVs) are important human pathogens associated with foodborne and waterborne gastroenteritis. These viruses are genetically highly heterogeneous, with more than forty genotypes within three genogroups (GI, GII, and GIV) identified in humans. However, the vast majority of human infections are associated with variants of a unique genotype, GII.4. Aside from these NoV strains of epidemiological relevance, NoV strains of genogroup GIV (Alphatron-like) are reported in a sporadic fashion and their overall prevalence in the community is unknown and this likely reflects the lack of specific diagnostic tools. We analyzed raw sewages collected from 32 wastewater treatment plants distributed throughout Italy (307 samples) and stool specimens collected from hospitalized patients with clinical signs of diarrhea of unknown etiology (285 samples). By using specific qualitative and quantitative RT-PCR assays, 21.8 % of the sewage samples and 3.2 % of the stool specimens tested positive for GIV NoVs. The number of genome copies in fecal samples ranged from 5.08 × 104 to 1.73× 106/g of feces. Sequence analysis showed limited genetic variability in human GIV viruses. The presence of GIV NoV both in sewage and in clinical samples confirms that not only GI and GII NoVs but also GIV strains are circulating in humans. Monitoring of GIV NoV is recommended in order to understand the dynamics of circulation in human populations, environmental contamination, and potential health risks.  相似文献   

10.
Within the initiatives for poliomyelitis eradication by WHO, Italy activated an environmental surveillance (ES) in 2005. ES complements clinical Acute Flaccid Paralysis (AFP) surveillance for possible polio cases, detects poliovirus circulation in environmental sewage, and is used to monitor transmission in communities. In addition to polioviruses, the analyses comprised: (i) the monitoring of the presence of non-polio enteroviruses in sewage samples and (ii) the temporal and geographical distribution of the detected viruses. From 2009 to 2015, 2880 sewage samples were collected from eight cities participating in the surveillance. Overall, 1479 samples resulted positive for enteroviruses. No wild-type polioviruses were found, although four Sabin-like polioviruses were detected. The low degree of mutation found in the genomes of these four isolates suggests that these viruses have had a limited circulation in the population. All non-polio enteroviruses belonged to species B and the most frequent serotype was CV-B5, followed by CV-B4, E-11, E-6, E-7, CV-B3, and CV-B2. Variations in the frequency of different serotypes were also observed in different seasons and/or Italian areas. Environmental surveillance in Italy, as part of the ‘WHO global polio eradication program’, is a powerful tool to augment the polio surveillance and to investigate the silent circulation or the re-emergence of enteroviruses in the population.  相似文献   

11.
A hepatitis E outbreak, which occurred on a small isolated island, provided an opportunity to evaluate the association between the number of hepatitis E cases in the community and the concentration of virus detected in sewage. Samples were collected from the different sewage treatment plants from the island and analyzed for the presence of hepatitis E (HEV) virus using real-time RT-PCR. We demonstrated that if 1–4 % of inhabitants connected to a WWTP were infected with HEV, raw sewage contained HEV at detectable levels. The finding that such a small number of infected people can contaminate municipal sewage works raises the potential of the further distribution of the virus. Indeed, investigating the routes of transmission of HEV, including the potential for sewage effluent to contain infectious HEV, may help us to better understand the epidemiology of this pathogen, which is considered to be an emerging concern in Europe.  相似文献   

12.
13.
Noroviruses (NoVs) are responsible for numerous cases of waterborne and foodborne gastroenteritis every year. They are released in the sewage and their detection in this environment can reflect the epidemiology of the viral strains circulating in the community. A three-year (2007–2010) survey was conducted in order to evaluate the presence of human NoVs using RT-PCR in 518 sewage samples collected at the entrance and exit of two biological sewage treatment plants located in Monastir region, Tunisia. In this study, we aimed to genetically characterize the most prevalent GI and GII NoV strains, in order to obtain a rough estimate of the efficacy of disinfection treatments and to compare the results with clinical data documented in the same area during the same period. This work confirms the wide circulation and the genetic diversity of NoVs in Tunisia and the widespread distribution of NoV variants in both raw and treated wastewater. Indeed, NoV was detected in 192 (37.1 %) sewage samples, among them mixed infections with group A rotavirus were detected in 125 (65.1 %) cases. The genotypes of the GI NoVs were GI.1, GI.2, GI.4, GI.5, and GI of unassigned genotype (GI.UA), and the genotypes of the GII NoVs were all GII.12. This study enhances the currently poor environmental virological data gathered in Tunisia, demonstrates the benefit of environmental surveillance as a tool to determine the epidemiology of NoVs circulating in a given community, and underlines the need for the design and support of similar long-term studies in our country, in order to compensate for the absence of a national surveillance system for gastroenteric viruses.  相似文献   

14.
This study proposed to detect the enterovirus (EV) infection in children with type 1 diabetes mellitus (T1D) and to assess the role of insufficiently treated water and sewage as sources of viral spreading. Three hundred and eighty-two serum specimens of children with T1D, one hundred serum specimens of children who did not suffer from T1D as control, and forty-eight water and sewage samples were screened for EV RNA using nested RT-PCR. The number of genome copies and infectious units of EVs in raw and treated sewage and water samples were investigated using real-time (RT)-PCR and plaque assay, respectively. T1D markers [Fasting blood glucose (FBG), HbA1c, and C-peptide], in addition to anti-Coxsackie A & B viruses (CVs A & B) IgG, were measured in control, T1D-negative EV (T1D–EV?), and T1D-positive EV (T1D–EV+) children specimens. The prevalence of EV genome was significantly higher in diabetic children (26.2%, 100 out of 382) than the control children (0%, 0 out of 100). FBG and HbA1c in T1D–EV? and T1D–EV+ children specimens were significantly higher than those in the control group, while c-peptide in T1D–EV? and T1D–EV+ children specimens was significantly lower than that in the control (n = 100; p < 0.001). Positivity of anti-CVs A & B IgG was 70.7, 6.7, and 22.9% in T1D–EV+, T1D–EV?, and control children specimens, respectively. The prevalence of EV genome in drinking water and treated sewage samples was 25 and 33.3%, respectively. The prevalence of EV infectious units in drinking water and treated sewage samples was 8.5 and 25%, respectively. Quantification assays were performed to assess the capabilities of both wastewater treatment plants (WWTPs) and water treatment plants (WTPs) to remove EV. The reduction of EV genome in Zenin WWTP ranged from 2 to 4 log10, while the reduction of EV infectious units ranged from 1 to 4 log10. The reduction of EV genome in El-Giza WTP ranged from 1 to 3 log10, while the reduction of EV infectious units ranged from 1 to 2 log10. This capability of reduction did not prevent the appearance of infectious EV in treated sewage and drinking water. Plaque purification was performed for isolation of separate EV isolates from treated and untreated water and sewage samples. Characterization of the EV amplicons by RT-PCR followed by sequencing of these isolates revealed high homology (97%) with human coxsackievirus B4 (CV B4) in 60% of the isolates, while the rest of the isolates belonged to poliovirus type 1 and type 2 vaccine strains. On the other hand, characterization of the EV amplicons by RT-PCR followed by sequencing for T1D–EV+ children specimens indicated that all samples contained CV B4 with the same sequence characterized in the environmental samples. CV B4-contaminated drinking water or treated sewage may play a role as a causative agent of T1D in children.  相似文献   

15.
The occurrence of enteric viruses in reclaimed wastewater, their removal by efficient treatment processes and the public health hazards associated with their release into the environments are of great significance in environmental microbiology. In this study, TaqMan-based real-time polymerase chain reaction (qPCR) was used to assess the prevalence of human adenovirus (HAdV), rotavirus (RV) and hepatitis A virus (HAV) in the final effluents of two wastewater treatment plants in the Eastern Cape Province, South Africa, over a twelve-month sampling period. The correlation between the concentrations of viruses in the effluents samples and faecal coliform (FC) densities were assessed as to validate the use of FC as microbiological indicator in water quality assessment. HAdV was detected in 62.5 % (30/48) of the samples with concentrations ranging between 8.4 × 101 and 1.0 × 105 genome copies/L while HAV and RV were only detected at concentrations below the set detection limits. FCs densities ranged from 1 to 2.7 × 104 CFU/100 ml. Adenovirus species HAdV-B (serotype 2) and HAdV-F (serotype 41) were detected in 86.7 % (26/30) and 6.7 % (2/30) of the HAdV-positive samples, respectively. No consistent seasonal trend was observed in HAdV concentrations, however, increased concentrations of HAdV were generally observed in the winter months. Also, there was no correlation between the occurrence of HAdV and FC at both the treatment plants. The persistent occurrence of HAdV in the discharged treated effluents points to the potential public health risk through the release of HAdV into the receiving watersheds, and the possibility of their transmission to human population.  相似文献   

16.
Human bocavirus (HBoV) is predominantly found in the respiratory tract infections and in the stool of patients with gastroenteritis symptoms. However, data on the prevalence of HBoV genotypes in environmental samples are limited. Here we addressed the prevalence of HBoV in sewage collected from three different wastewater treatment plants in Egypt. HBoV-1, HBoV-2, and HBoV-3 were detected, whereas none of the samples were positive for HBoV-4. The median concentration of HBoV in influent samples was 8.5 × 103 GC/l for HBoV-1, 3.0 × 104 GC/l for HBoV-2, and 2.5 × 104 GC/l for HBoV-3. The concentration was reduced but not completely removed in the effluent samples. The median concentration in the outlet samples was 2.9 × 103 GC/l for HBoV-1, 4.1 × 103 GC/l for HBoV-2, and 2.1 × 103 GC/l for HBoV-3. Moreover, no seasonality pattern of HBoVs was found. The high incidence of HBoV in sewage samples provided an evidence of its circulation in the local population. Although the role of HBoV in respiratory or gastro-intestinal infections still remains to be fully elucidated, the risk of infection via contaminated water should be taken into consideration.  相似文献   

17.
Torque teno virus (TTV) was surveyed in tap water collected in schools from three municipalities located in the south of Brazil. TTV genomes were found in 11.7 % (4/34) of the samples. TTV DNA was detected in 10.5 % (2/19) of the samples collected at the city of Caxias do Sul and in 25 % (2/8) of the samples from Pelotas. Those cities have a low rate of sewage treatment. All samples from Santa Cruz do Sul, which has nearly 92 % of its sewage treated, were negative. These results suggest that the amount of sewage treated may have an effect on the detection rates of TTV DNA in drinking water in a given urban area, showing a mild negative correlation (r = ?0.76), when comparing the percentage of sewage treatment to the detection of TTV genomes. The detection rate of TTV was also compared with Escherichia coli, showing a strong correlation (r = 0.97), indicating that TTV may be a suitable marker of fecal contamination.  相似文献   

18.
The objective of this study is to compare the prevalence of rotaviruses groups A and C in Egyptian children and aquatic environment. From 110 stool specimens of children with acute diarrhea and using RT-PCR, 35 samples (31.8 %) were positive for human rotavirus group A and 15 samples (13.6 %) were positive for human rotavirus group C. From 96 samples collected from Zenin wastewater treatment plant over a 2-year period (November 2009–October 2011) and using RT-PCR, rotavirus group A was detected in (4/24) 16.7 %, (5/24) 20.8 %, (4/24) 16.7 %, and (4/24) 16.7 %, while rotavirus group C was detected in (2/24) 8.3 %, (3/24) 12.5 %, (3/24) 12.5 %, and (0/24) 0 % in raw sewage, after primary sedimentation, after secondary sedimentation, and after final chlorination, respectively. Moreover, from 96 samples collected from El-Giza water treatment plant over a 2-year period (November 2009–October 2011), rotavirus group A was detected in (7/24) 29.2 %, (6/24) 25 %, (5/24) 20.8 %, and (3/24) 12.5 %, while rotavirus group C was detected in (3/24) 12.5 %, (1/24) 4.2 %, (1/24) 4.2 %, and (0/24) 0 % in raw Nile water, after sedimentation, after sand filtration, and after final chlorination, respectively. Using SYBR Green real-time RT-PCR, the number of human rotavirus group A genome or infectious units was higher than rotavirus group C. VP6 sequence analysis of the RT-PCR positive rotavirus group C samples revealed that four clinical specimens and three environmental samples showed similar sequences clustered with Moduganari/Human Nigerian strain AF 325806 with 98 % homology, and two clinical specimens and one environmental sample showed similar sequences clustered with Dhaka CB/Human Bangladesh strain AY 754826 with 97 % homology.  相似文献   

19.
20.
A polymerase chain reaction–denaturing gradient gel electrophoresis (PCR–DGGE) method was employed to estimate the contamination sources of human enteroviruses and understand how their dominant strains vary in a wastewater treatment and reclamation system consisting of sewage collection, wastewater treatment with membrane bioreactor and open lakes for reclaimed water storage and reuse. After PCR–DGGE using a selected primer set targeting enteroviruses, phylogenetic analysis of acquired enterovirus gene sequences was performed. Enteroviruses identified from the septic tank were much more diverse than those from grey water and kitchen wastewater. Several unique types of enterovirus different from those in wastewater samples were dominant in a biological wastewater treatment unit. Membrane filtration followed by chlorination was proved effective for physically eliminating enteroviruses; however, secondary contamination likely occurred as the reclaimed water was stored in artificial lakes. Enterovirus 71 (EV71), a hand-foot-and-mouth disease (HFMD) viral pathogen, was detected mainly from the artificial lakes, implying that wastewater effluent was not the contamination source of EV71 and that there were unidentified non-point sources of the contamination with the HFMD viral pathogen in the reclaimed water stored in the artificial lakes. The PCR–DGGE targeting enteroviruses provided robust evidence about viral contamination sources in the wastewater treatment and reclamation system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号