首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
BTPM-AS1PM_(2.5)全自动重量法监测仪是一种根据PM_(2.5)手工重量法原理设计的PM_(2.5)自动监测仪器,能够实现样品采集、滤膜平衡、滤膜称重等环节的自动化。采用线性回归分析法对PM_(2.5)全自动重量法监测仪器的监测结果与PM_(2.5)连续自动监测仪器、手工标准方法进行比对分析,讨论了该原理仪器的流量准确性、滤膜平衡效果、天平稳定性。结果显示:PM_(2.5)全自动重量法仪器监测结果与PM_(2.5)连续自动监测仪器、手工重量法监测结果的相关系数为0.927 2~0.994 1,监测结果之间具有较高的一致性,并且其样品采集、滤膜平衡、滤膜称重等关键环节的主要技术指标能够满足中国PM_(2.5)手工标准测定方法的相关要求。  相似文献   

2.
A cylindrical dialysis sampler (1.2 m in length; 5 cm in diameter) was designed and constructed to sample small–scale phytoremediation processes in the root zone of poplar trees. The study site was a 183–tree plantation of hybrid poplars located at Aberdeen Proving Ground, Maryland, at the J–Field Area of Concern. The grove was planted in 1996 to intercept a chlorinated solvent plume containing 1,1,2,2–tetrachloroethane (1,1,2,2–TeCA, trichloroethene (TCE) and daughter products. Two dialysis samplers were installed: one directly in the poplar grove (approximately 0.3 m from the trunk of a mature tree) and the other outside of the grove but in the plume. Data collected included concentrations of chlorinated VOCs, organic acids, chloroacetic acids, Cl, and dissolved gases (ethane, ethene, CH4, CO2). At the control location, the VOC profile was dominated by cis– 1,2–dichloroethene (cis–1,2–DCE) and trans–1,2–dichloroethene (trans–1,2–DCE) with concentrations ranging from 0.88-4.5 to 4.4-17.6 mg/L, respectively. Concentrations of VOCs were similar across the vertical profile. At the tree location, 1,1,2,2–TeCA and TCE were the dominant VOCs detected but as opposed to the control location were highly variable within the root zone, with the greatest variability associated with locations in the sampler where roots were observed. This highly variable profile at the tree location is indicative of VOC rhizosphere biodegradation and uptake near the active roots. This variability appears to be on the centimeter scale, emphasizing the importance of these high–resolution samplers for the study of rhizosphere influences.  相似文献   

3.
Automatic samplers are a common method of data collection for numerous monitoring projects in the South Florida region and elsewhere. Although total phosphorus (TP) is the primary parameter of interest within this region, nitrogen species such as ammonia nitrogen (NH4-N), nitrate+nitrite nitrogen (NOx-N), and total kjeldahl nitrogen (TKN) are also collected and analyzed. Federal and state quality assurance guidelines require nutrient samples to be preserved by acidification with H2SO4 to a pH < 2 and stored immediately at 4 °C. However, the remoteness of manysampling locations in South Florida makes it difficult to supplyelectricity for the refrigeration of samples collected by autosamplers. In addition, the use of propane-powered refrigerated autosamplers is a costly and ineffective solution in the South Florida climate. Consequently, while samples collected at these remote locations are routinely pre-preservedwith acid, they are not cooled to 4 °C for a period fromone to seven days. This study evaluated if a statistically significant difference ( = 0.05) existed between concentrations of nitrogen species from a common source samplethat was either: processed immediately; refrigerated to 4 °C for seven days; or not refrigerated for seven days.In all cases, the collected sample was pre-preserved by adding 1 mL of 50% H2SO4 to each 1 L discrete sample container before each 7 day testing period. Differences in concentrations of the calculated parameter total nitrogen (TN)were also investigated.Analyses using the Wilcoxon Signed-Rank Test showed no significant differences among the three treatment groups for NOx-N, TKN, TN and TP. Significant differences were observedwhen the NH4-N samples that were processed immediately werepaired with NH4-N samples that were left unrefrigerated or refrigerated for seven days. Information from this study can be used by researchers and managers in evaluating the usefulness of nutrient water quality data that is collected when sample refrigeration is not available.  相似文献   

4.
基于北京市PM2.5和PM10质量浓度、组分浓度以及降水数据,利用数理统计、相关性分析等方法分别从降水总量、降水时长和降水前颗粒物浓度3个角度研究降水对PM2.5、PM10的清除作用,同时以一次典型降水过程为例,具体分析降水对颗粒物的影响。结果表明:降水总量的增加有助于促进PM2.5、PM10的清除,随着降水总量增加,PM2.5、PM10的平均清除率提高,有效清除的比例增加;连续降水可增强对大气颗粒物的湿清除作用,连续降水达3d可有效降低PM2.5、PM10浓度;降水对PM2.5、PM10浓度的清除率和大气颗粒物前一日的平均浓度有较好的正相关性。降水对大气颗粒物的清除可分为清除、回升和平稳3个阶段,各个阶段大气颗粒物的变化趋势不同。降水对于大气气溶胶化学组分和酸碱性的改变具有明显作用,对于大气颗粒物各种组分的清除效果不完全相同。对于大气中OC、NO3-、SO42-和NH4+去除率较高,且这4种组分主要以颗粒态形式被冲刷进入降水中,加剧了北京市降水酸化程度。  相似文献   

5.
大气颗粒物采样器的设计与应用   总被引:2,自引:1,他引:1  
自行开发设计大气颗粒物双通道采样器,通过更换粒径切割器实现对大气总悬浮颗粒物(TSP)、可吸入颗粒物(PM10)或细颗粒物(PM2.5)样品的采集。该仪器通过流量传感器、比例阀和流量控制板精确控制每个通道的采样流量,控制系统还可实时采集大气环境温度、压力、湿度、风速和风向5个气象参数,并根据环境温度、压力的变化对采样的体积流量进行补偿计算,以确保进样口体积流量恒定,保证粒径切割准确。在2011年深圳大学生运动会期间(8月12—23日)和后期(8月24日至9月4日),利用该仪器进行了大气环境野外观测实验,并对该仪器和Thermo2300采样器的结果进行了平行性分析和对比分析,其平行结果和对比结果相关系数均大于0.99。  相似文献   

6.
一种淡水大型底栖无脊椎动物采样器研究   总被引:2,自引:2,他引:0  
研制出一种长方体的十字筐采样器,在采样器内分别填装石、砂、底泥和水草4种基质,利用大型底栖无脊椎动物对生境的选择性进行样本被动采集。基质越多,采样器采集的生物种类越多,生物量也更丰富。用新研制的十字筐采样器和传统的篮式采样器对松花江流域7个采样点进行大型底栖无脊椎动物对比采样,结果显示:十字筐采样器是一种优良的采样器,适合在松花江流域乃至全国推广应用。  相似文献   

7.
Ambient concentrations of PM2.5 and PM10 are of concern with respect to effects on human health and environment. Increased levels of mortality and morbidity have been associated with respirable particulate air pollution. In India, it is not yet mandatory to monitor PM2.5 levels therefore very limited information is available on PM2.5 levels. To understand the fine particle pollution and also correlate with PM10 which are monitored regularly in compliance with ambient air quality standards. This study was carried out to monitor PM2.5, PM10, and NO2 for about one year in a residential cum commercial area of Mumbai city with a view to understand their correlation. The average PM2.5 concentration at ambient and Kerbsite was 43 and 69 μg/m3. The correlation coefficients between PM2.5 and PM10 at ambient and Kerbsite were 0.83 and 0.85 respectively thus indicating that most of the PM2.5 and PM10 are from similar sources. TSP, PM10 levels exceeded Central Pollution Control Board(CPCB) standard during winter season. PM2.5 levels also exceeded 24 hourly average USEPA standard during winter season indicating unhealthy air quality.  相似文献   

8.
A dissolved oxygen (DO) model is calibrated and verified for a highly polluted River Ravi with large flow variations. The model calibration is done under medium flow conditions (431.5 m3/s), whereas the model verification is done using the data collected during low flow conditions (52.6 m3/s). Biokinetic rate coefficients for carbonaceous biochemical oxygen demand (CBOD) and nitrogenous biochemical oxygen demand (NBOD) (i.e, K cr and K n ) are determined through the measured CBOD and ammonia river profiles. The calculated values of K cr and K n are 0.36 day?1 and 0.34 day?1, respectively. The close agreement between the DO model results and the field values shows that the verified model can be used to develop DO management strategies for the River Ravi. The biokinetic coefficients are known to vary with degree of treatment (DOT) and therefore need to be adjusted for a rational water quality management model. The effect of this variation on level of treatment has been evaluated by using the verified model to attain a DO standard of 4 mg/L in the river using the biokinetic rate coefficients as determined during the model calibration and verification process. The required DOT in this case is found to be 96 %, whereas the DOT is 86 % if adjusted biokinetic rate coefficients are used to reflect the effect of wastewater treatment. The cost of wastewater treatment is known to increase exponentially as the removal efficiency increases; therefore, the use of appropriate biokinetic coefficients to manage the water quality in rivers is important.  相似文献   

9.
A workshop on analytical quality control (AQC) of ambient air quality measurement methods for nitrogen dioxide (NO2) and sulphur dioxide (SO2) was conducted by Central Pollution Control Board (CPCB) for officials involved in National Ambient Air Quality Monitoring (NAAQM) in India. Concentrations of NO2 and SO2 were generated by dynamic dilution system under laboratory conditions at low and high levels and measured using static dilution system and wet chemical methods laid down by CPCB under section 16(2)(h) of the air act 1981. CPCB provided the measured values as reference values for comparing the means obtained by the officials participated from thirteen organizations. A tolerance limit of ±15% of the reference values was specified to accept the results. Generated concentrations, which were unknown to the participants, were measured using gaseous sampling assembly (Envirotech APM 411, New Delhi, India), and wet chemical methods laid down by CPCB i.e. the same methodology which is used by the organizations to generate the data of NO2 and SO2 in ambient air. Simultaneously, concentrations were checked by CPCB using automatic analyzers as a check on reference concentration. It is observed that results of automatic analyzers for NO2 and SO2 were within a tolerance of ±5% with %RSD below 3. On the other hand, results of most of the participants showed variability in the measurements with %RSD ranging between ±0.8 and ±88.6 and exceedences of means from the tolerance limit with bias ranging between 1.4 and −59%. To check the cause of high variability in the measurements obtained under identical conditions, duplicate sampling was performed by one of the participants for SO2 at low concentration level. In this study, results of wet chemical methods, automatic analyzers and results of duplicate sampling are analysed statistically to assess the cause of high variability in the measurements. Analysis of t-test and analysis of variance (ANOVA) showed highly significant results for NO2 and SO2 at high concentration levels (α 0.05) and for SO2 at both the levels (α 0.01) respectively indicating some bias is existing either in the sampling or in analytical technique. Duplicate sampling performed to check precision in parallel measurements showed high %RSD indicating the presence of systematic error in sampling technique as the same calibration factor (CF) was used to measure the concentration of duplicate samples. Statistical analysis of flow rates of duplicate sampling showed that the sampling assembly could not maintain the constant flow rate within the ±10% with that measured at the start of the sampling. This resulted in high %RSD and deviation from the reference values for the results of most of the participants, even after accepting ±15% tolerance limit. There is a need to improve and evaluate this gaseous sample collection device under laboratory conditions to generate reliable database of NO2 and SO2 in ambient air.  相似文献   

10.
Passive diffusion samplers were employed in San Miguel(Buenos Aires Metropolitan Area) for a preliminary airpollution monitoring. The highest loads were observedin downtown, compared with an urban background site.Total suspended particulate matter (TSPM) varied from0.257 to 0.033 mg cm-2 month-1; dust was examinedfor particle nature and size distribution. A similartrend was observed for nitrogen dioxide (NO2) andTSPM spatial distribution, suggesting that traffic isthe major pollution source. Sulphur dioxide (SO2)values were low and rather homogeneous. Levels for theinvestigated pollutants are below EPA's guide linevalues. Geographic (flat area, near to Rio de LaPlata) and climatologic factors (rainfalls andvariable wind directions) contribute to disperse pollutants.  相似文献   

11.
This study monitored atmospheric pollutants during high wind speed (> 7 m s−1) at two sampling sites: Taichung Harbor (TH) and Wuci traffic (WT) during March 2004 to January 2005 in central Taiwan. The correlation coefficient (R 2) between TSP, PM2.5, PM2.5−10 particle concentration vs. wind speed at the TH and WT sampling site during high wind speed (< 7 m s−1) were also displayed in this study. In addition, the correlation coefficients between TSP, PM2.5 and PM2.5−10 of ionic species vs. high wind speed were also observed. The results indicated that the correlation coefficient order was TSP > PM2.5−10 > PM2.5 for particle at both sampling sites near Taiwan strait. In addition, the concentration of Cl, NO3 , SO4 2−, NH4 +, Mg2+, Ca2+ and Na+ were also analyzed in this study.  相似文献   

12.
Readily available nitrogen (N) sources such as ammonium nitrate with excessive irrigation present a potential hazard for the environment. The computer program Nitrate Leaching and Economic Analysis Package (NLEAP) is a mechanistic model developed for rapid site-specific estimates of nitrate-nitrogen (NO3-N) moving below the root zone in agricultural crops and potantial impacts of NO3-N leaching into groundwater. In this study, the value of NLEAP was tested to simulate N uptake by crops and NO3-N leaching parameters in large lysimeters under the tomato crop. Three seedlings of tomato variety of H-2274 (Lycopersicum esculentum L.) were transplanted into each lysimeter. N fertilizer at the rate of 140 kg N ha–1 was sidedressed in two split applications, the first half as ammonium sulphate and the second half as ammonium nitrate. The lysimeters were irrigated based on programs of C 0.75, 1.00, 1.25 and 1.50, C referring to class A-Pan evaporation coefficients. Parameters such as leaching index (LI), annual leaching risk potential (ALRP), N available for leaching (NAL), amount of NO3-N leached (NL) and amount of N taken up by the crops (NU) were estimated using the NLEAP computer model. To test the ability of model to simulate N uptake and NL, measured values were compared with simulated values. Significant correlations, R2 = 0.92 and P < 0.03 for the first year and R2 = 0.86 and P < 0.06 for the second year, were found between measured and simulated values for crop N consumption, indicating that the NLEAP model adequately described crop N uptake under the varied irrigation programs using an optimal N fertilization program for the experimental site. Significant correlations, R2 = 0.96 and P < 0.01 for the first year and R2 = 0.97 and P < 0.01 for the second year, were also found between measured and simulated values of NL, indicating that the NLEAP model also adequately predicted NL under the varied irrigation programs. Therefore, this computer model can be useful to estimate the NO3-N moving beyond the root zone under conditions in which the present experiment was carried out. Also, the NLEAP-estimated NAL values and other parameters can also be used to improve N management practices and N fertilizer recommendations that will help to decrease the adverse effect of N fertilizer on groundwater quality and farm profitability.  相似文献   

13.
上海臭氧及前体物变化特征与相关性研究   总被引:19,自引:15,他引:4  
于2010年1~12月期间,在上海城区内采用在线连续观测,分析该地区近地臭氧与其前体物的季节变化规律及相关性,探讨了臭氧浓度与OX和NO2光解速率之间的关系。结果表明,观测期间,上海地区O3总超标天数为13天,超标率为3.56%。O3浓度变化呈现明显的秋冬低、春夏高的季节变化。O3浓度日变化规律呈典型单峰变化,O3各前体物呈双峰形分布,冬季O3与NOX的相关性最强。对OX的贡献中,秋冬以NO2为主,春夏以O3为主;夜间以NO2为主,白天以O3为主。臭氧浓度与OX和NO2光解速率变化规律基本一致。  相似文献   

14.
A new all season passive sampling system for monitoring O3 in the atmosphere has been developed in the laboratory and validated in the field. The unique features for this system include a newly designed passive sampler and a rain shelter, which allow the passive sampler to be installed in the field facing downwards. An equation associated with meteorological parameters is used to calculate the passive sampling rates. This system has been extensively tested in the lab (temperature from –18 to 20°C, relative humidity from 13 to 81%, and wind speed from 0.5 to 150 cm/s) and validated in the field in climates of all seasons. The accuracy of the ozone concentrations in the atmosphere obtained with the use of the new passive sampling system was higher than 85% compared to those obtained with continuous ozone analyzers. The new ozone passive sampling system can be used to measure ambient O3 concentrations ranging from 3 ppb to 1000 ppb based on one-day exposure and 0.1 ppb to 140 ppb for a monthly exposure period. It is also reasonable to conclude that the new passive sampling system can be used for eight-hour exposure study because of the low field blanks and high sampling rates.  相似文献   

15.
Titanium dioxide is the most important photocatalysts used for purifying applications. If a TiO2- containing material is left outdoors as a form of flat panels, it is activated by sunlight to remove harmful NOx gases during the day. The photocatalytic efficiency of a TiO2-treated mortar for removal of NOx was investigated in the frame of this work. For this purpose a fully equipped monitoring system was designed at a pilot site. This system allows the in situ evaluation of the de-polluting properties of a photocatalytic material by taking into account the climatologic phenomena in street canyons, accurate measurements of pollution level and full registration of meteorological data The pilot site involved three artificial canyon streets, a pollution source, continuous NOx measurements inside the canyons and the source as well as background and meteorological measurements. Significant differences on the NOx concentration level were observed between the TiO2 treated and the reference canyon. NOx values in TiO2 canyon were 36.7 to 82.0% lower than the ones observed in the reference one. Data arising from this study could be used to assess the impact of the photocatalytic material on the purification of the urban environment.  相似文献   

16.
环境空气质量新标准对珠三角区域站空气质量评价的影响   总被引:4,自引:4,他引:0  
利用粤港珠三角区域空气质量监控网中天湖、金果湾与万顷沙3个区域站2010年全年SO2、NO2、PM10、O3、PM2.5与CO自动监测的数据,分析了实施环境空气质量新标准(GB 3095—2012)对这3个子站空气质量评价的影响。研究发现,若采用新标准,万顷沙的NO2、PM10和PM2.5年均浓度将不同程度超标。这3个子站空气质量达标率下降7~28个百分点,空气污染指数从91%~99%下降至63%~91%;O3的引入是导致空气质量达标率下降的最主要的原因;O3将取代PM10成为最主要的首要污染物,出现频率大于50%,且O3(8 h)平均浓度的影响大于O3 (1 h)浓度的影响。PM2.5的纳入也是导致空气质量达标率下降的重要因素,其超标率为3%(金果湾)~16%(万顷沙)。NO2标准的收严未对天湖与金果湾空气质量评价造成影响,但导致万顷沙NO2的超标率从2%上升至10%,且NO2作为首要污染物的比例达24%。  相似文献   

17.
Measurement of nitrogen dioxide using passivediffusion tube over 22 months in Cambridge, U.K. areanalysed as a function of sampler exposure time, andcompared with NO2 concentrations obtained from aco-located chemiluminescence analyser. The averageratios of passive sampler to analyser NO2 at acity centre site (mean NO2 concentration 22 ppb)are 1.27 (n = 22), 1.16 (n = 34) and 1.11 (n = 7) forexposures of 1, 2 and 4-weeks, respectively. Modellingthe generation of extra NO2 arising from chemicalreaction between co-diffusing NO and O3 in thetube gave a ratio (modelled/measured) of 1.31 for1-week exposures. Such overestimation is greatest whenNO2 constitutes, on average, about half of totalNOx (= NO + NO2) at the monitoring locality.Although 4-week exposures gave concentrations whichwere not significantly different from analyserNO2, there was no correlation between thedatasets. At both the city-centre site and anothersemi-rural site (mean NO2 concentration 11 ppb)the average of the aggregate of four consecutive1-week sampler exposures or of two consecutive 2-weeksampler exposures was systematically greater than fora single 4-week exposure.The results indicate two independent and opposingsystematic biases in measurement of NO2 bypassive diffusion sampler: an exposure-timeindependent chemical overestimation with magnitudedetermined by local relative concentrations of NO andO3 to NO2, and an exposure-time dependentreduction in sampling efficiency. The impact of theseand other potential sources of systematic bias on theapplication of passive diffusion tubes for assessingambient concentrations of NO2 in short (1-week)or long (4-week) exposures are discussed in detail.  相似文献   

18.
重点对河北省辛集市"十三五"期间整体空气质量变化情况以及影响辛集市优良天数的2个重要参数O3和PM2.5的污染规律进行了分析。结果表明,辛集市"十三五"期间空气质量改善明显,优良天数整体增加,污染天数整体减少。O3浓度及其作为首要污染物出现的天数整体呈现上升趋势,对综合指数的贡献率逐年增加;O3污染高发期主要集中在4—9月,高值区域分布差距较大,但市区污染持续突出。PM2.5浓度逐年下降,以PM2.5为首要污染物的天数逐年减少;PM2.5浓度季节变化特征整体呈现"秋冬高、春夏低"的分布特点,空间分布呈"南北高、中间低"的污染特征。  相似文献   

19.
Two-week average NO2 concentrations were measured in Amsterdam (NL), Huddersfield (UK) and Prague (CZ) at 80 sites in each study area, to assess small area spatial variation, using a tube type and a badge type passive sampler. The badges appeared to be less robust than the tubes. The lower detection limit for tubes and badges was 3.7 and 0.91 µg/m3, respectively for fortnightly measurements. Accuracy of the samplers was determined with reference methods (chemiluminescence). The mean ratio of the concentration measured by diffusion tube over that by the reference method was 1.16, 1.03 and 0.77 in Amsterdam, Huddersfield and Prague, respectively. Standardizing the badges for the results obtained in Amsterdam, the relative mean ratio of the concentration measured by the badges over that by the reference method was 0.95 and 0.58 in Huddersfield and Prague, respectively. NO2 concentrations measured by the two designs did not differ significantly. Mean NO2 concentrations were 36, 26 and 22 µg/m3 in Amsterdam, Huddersfield and Prague, respectively. The precision of duplicate tubes and badges was 8% and 11%, respectively. Both samplers are suitable for determining real variation in small area NO2 concentrations in the ranges which occurred. It is concluded that low-cost, simple NO2 passive samplers can provide reliable information about variation in NO2 concentrations within urban or rural areas on a small spatial scale. Based on its robustness and its precision, tubes were preferred over badges.  相似文献   

20.
It has been suggested that in relation to air quality impacts, roads with low (<20 000 vpd) traffic flow need not be consideredas significant. This study examines this suggestion more closelyby comparing real-time monitoring of traffic related pollutants (NO2, PM10 and PAH) at two sites (including a `canyon-street') in Falmouth, Cornwall in relation to traffic flow. For comparison, real-time monitoring data for NO2 and PM10 is also taken from a well ventilated site in Camelford, Cornwall. The data obtained suggest that roads with traffic flow considerably lower than 20 000 vpd can give rise topollutant levels which have implications for human health. The application of simple linear regression techniques to the datasuggests that under certain conditions simple estimates can be made in relation to likely traffic-related air quality effects in canyon-like streets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏