首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到7条相似文献,搜索用时 0 毫秒
1.
The purpose of this study was to develop an analytical method for the determination of organophosphorus and pyrethroid pesticides in soybean by pressurized liquid extraction (PLE). Two organic solvents, acetone and acetonitrile, were evaluated as extraction solvents. In both cases, the amount of extract was enhanced with increasing extraction temperature. The extracts obtained using acetonitrile were measured by gas chromatography/mass spectrometry after a cleanup process based on the analytical method for the Japanese Positive List System for Agricultural Chemicals Remaining in Foods. The effect of extraction temperature (range: 40– 130°C) on extraction efficiency was evaluated by a recovery study using 21 organophosphorus pesticides and 10 pyrethroid pesticides as target analytes and acetonitrile as the solvent. The results indicated that at 130°C, some organophosphorus pesticides might be degraded, whereas extraction temperatures between 70°C and 100°C were optimal. Next, a prepared sample containing fenitrothion and permethrin was analyzed. Although the sample was not soaked in water prior to analysis, PLE provided analytical results comparable to those obtained by solvent extraction with homogenization. Therefore, PLE is considered a simple and alternative technique for the extraction of organophosphorus and pyrethroid pesticides in soybean.  相似文献   

2.
Abstract

A pressurized liquid extraction (PLE) method was presented for the determination of six neonicotinoid pesticides, acetamiprid, clothianidin, dinotefuran, imidacloprid, thiacloprid, and thiamethoxam in green onion. The critical parameters of PLE, e.g. extraction solvent, temperature, pressure, number of cycles, and static extraction time, were optimized by test on the spiked green onion with six neonicotinoids and the incurred green onion applied with four commercial neonicotinoid insecticide formulations (acetamiprid, dinotefuran, imidacloprid, and thiamethoxam). As a result, the recoveries of six neonicotinoids obtained by one cycle PLE with acetonitrile at 140?°C and 50?bar for 10?min were 94.7–99.5%. These results were acceptable according to the validation guideline for testing method of agricultural chemicals in food by Ministry of Health, Labour, and Welfare in Japan. PLE was also validated by the test on the incurred green onion. The analytical values of four neonicotinoids obtained by PLE were good agreement with those obtained by solid–liquid extraction with homogenizer, which is employed for Japanese official method for the analysis of pesticide residues in food (the ratios of analytical values obtained by PLE to those obtained by solid–liquid extraction were 99.7–101.2%). These results indicate that PLE is applicable for the determination of neonicotinoids in green onion.  相似文献   

3.
Abstract

A saponification extraction method with gas chromatography pseudo-MRM (pMRM) mass spectrometry detection was developed for the determination of 50 total polycyclic aromatic hydrocarbons (TPAH50, a combination of parent and alkylated homologues) in biota. The method was aimed at monitoring and identification of potential TPAH contaminants in bitumen impacted environments. Alkylated PAHs were determined by multi-level, quantitative calibration using parent PAHs. The developed and thoroughly validated method required only one injection for TPAH50 analysis which represents significant saving of time and expensive authentic alkylated standards. The current method was tested with certified reference mussel tissue NIST 1974c and performed well. In a comparison study, the method reached a limit of quantitation (LOQ) for the TPAH50 between 0.1 and 0.2?ng g?1, while the QuEChERs enhanced matrix removal – lipid (EMR) kit produced by Agilent showed an LOQ of 5–10?ng g?1. The current method relied on response factors (RF) for the quantitation of alkylated PAHs determined against parent PAHs. These RFs were shown to be stable and consistent over the course of 1 year, during which over 200 routine environmental biota monitoring samples were analyzed. The environmental biota monitoring samples analyzed include muscle, carcass and liver, with an average total PAH50 concentration of 13, 90 and 135?ng g?1, respectively. Results show significant differences in the distributions of 1 ringed, 2 ringed, 3 ringed, 4 ringed, and 5+ ringed TPAHs between the types of biota samples.  相似文献   

4.
This research aimed to optimize the extraction method parameters for sample pretreatment and determine the levels of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) contamination in food packaging made of paper. Techniques used were pressurized liquid extraction (PLE) followed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Influence parameters of PLE were carefully evaluated for extracted concentration of samples in low level (ng g?1). The study found that the optimal conditions for PLE were 30 min static extraction time with a flush volume of 100% cell volume and one extraction cycle at 80°C and 1,000 psi. The extraction technique validated the absolute recovery from PFOS and PFOA fortified control samples at three different levels (5, 50, and 200 ng g?1), with seven repeats at each fortification level. The average recoveries were 79% or higher, with relative standard deviation (RSD) less than 11%. Optimization of the PLE method was established based on recovery data, accuracy, precision, and repeatability of the method. Using optimal PLE technique, PFOS and PFOA were extracted from 34 food-packaging samples collected in Thailand. PFOS and PFOA were detected in all kinds of collected samples, with average concentrations of 4.89 and 2.87 ng g?1, respectively. The concentrations of PFOS and PFOA were highest in fast-food container samples: 36.99 and 9.99 ng g?1, respectively.  相似文献   

5.
The aim of this study was to develop an analytical method for the determination of residues of organophosphorus and carbamate pesticides which are widely used in Tunisia. This method involves a liquid-liquid extraction procedure followed by liquid chromatography tandem mass spectrometry (LC/MS/MS) for the identification and quantification of compounds. Ionization of molecules was performed by the electrospray mode. Multiple reactions monitoring (MRM) was the acquisition mode used for the monitoring of two MS/MS transitions for each compound. The average recoveries obtained, at three different fortification levels, ranged between 65% and 106% for most of the pesticides studied, except for methamidophos (lower than 25%).The linearity of the method was in the range of 5 to 50 μ g/L with a correlation coefficient from 0.995 to 0.999, depending on the analyte. The estimated limit of detection and limit of quantification were 2 μ g/L and 5 μ g/L, respectively. The precision of the analytical procedure was satisfactory and the coefficients of variation, evaluated at three concentration levels were lower than 15% for most pesticides studied. The application of the method was investigated in a population of agricultural workers chronically exposed to various pesticides some of which, such as carbofuran, carbendazim, methomyl and pirimicarb, were detected in some serum samples.  相似文献   

6.
The work was carried out to develop and validate a method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous detection and quantification of five neonicotinoid insecticides: acetamiprid, clothianidin, imidacloprid, thiacloprid and thiamethoxam in groundwater samples for the purpose of a further column experiment. This experiment will be used to analyze breakthrough curves of neonicotinoids under a saturated water flow to set transport parameters, where the reliability of the results of chemical analysis plays an important role. The validation was performed in a concentration range from 0.09?µg L?1 to 100?µg L?1 using an Infinity 1290 (Agilent, USA) chromatograph coupled with a QTrap 5500 mass spectrometer (Sciex, Canada). The calibration curves were obtained on the basis of the results of six standard solution analyses. Linearity was not lower than 0.998. The limit of detection was set at the lowest concentration which can be determined with an acceptable accuracy and precision. All pesticides had recoveries in the range 85–109% with relative standard deviation values less than 8.1%. The estimated measurement uncertainty did not exceed 30%, so the LC-MS/MS method fits for the intended purpose.  相似文献   

7.
This work describes the development, optimization and validation of an analytical method for the simultaneous detection and identification of 74 pharmaceutically active compounds (PhACs), from various therapeutic groups, in both environmental (ground and surface water) and wastewaters (WW). The method is based on the simultaneous extraction of all target compounds by solid phase extraction (SPE), using a hydrophilic-lipophilic balanced polymer followed by ultra high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS). Two selected reaction monitoring (SRM) transitions have been monitored per compound in order to fulfil the EC guidelines, as well as to ensure an accurate identification of target compounds in the samples. Quantification is performed by internal standard approach, applying 24 specific isotopically labeled compounds. The main advantages of the developed method, besides the selectivity and reliability of the results, is its high throughput. All compounds are extracted in a single step and the instrumental analysis lasts 5 min (NI mode) + 8 min (PI mode), allowing fast throughput of samples. The limits of detection range from 0.01 to 50 ng L−1, depending on the matrix, for most of the compounds. Finally, the method developed has been applied to the analysis of pharmaceuticals in the Ebro river basin (NE Spain).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号