首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
ABSTRACT: An 18-month field experiment was conducted to evaluate the effectiveness of grass filter strips in removing sediment and various nitrogen species from runoff. Runoff was collected from six 3.7 m wide experimental plots with 24.7 m long runoff source areas. Two plots had 8.5 m filters, two plots had 4.3 m filters, and two plots had no filters. Runoff was analyzed for total suspended solids (TSS), total Kjeldahl nitrogen (TKN),. filtered TKN (FTKN), NH4+-N, and NO3-N. The Mann-Kendall nonparametric test for trend (changes in filter effectiveness over time) indicated that there were no trends in the yields and concentrations of TSS, NO3--N, NH4-N, TKN, and FTKN for the 8.5 m filter over time. For the shorter 4.3 m filters, there were significant upward trends in TKN yield and downward trends in TSS, NH4-N, and FTKN concentrations, indicating that trapping efficiency may have started changing with time. The Kruskal-Wallis test indicated that the 8.5 m filters reduced median yields and concentrations of TSS and all N species, but the 4.3 m filters only reduced the median yields and concentrations of TSS, NH4+-N, TKN, and the median concentration of FTKN. The 8.5 and 4.3 m filters reduced contaminate yields and concentrations from 42 to 90 percent and from 20 to 83 percent, respectively.  相似文献   

2.
This paper presents the results of an intensive monitoring activity of the particulate, fall-out and soil of selected living areas in Italy with the aim to detect the asbestos concentration in air and subsequent risk of exposure for the population in ambient living environments, and to assess the nature of the other mineral phases composing the particulate matrix. Some areas were sorted out because of the presence of asbestos containing materials on site whereas others were used as blank spots in the attempt to detect the background environmental concentration of asbestos in air. Because the concentration of asbestos in ambient environments is presumably very low, and it is well known that conventional low–medium flow sampling systems with filters of small diameter (25 mm) may collect only a very small fraction of particulate over a short period, for the first time here, an intense monitoring activity was conducted with a high flow sampling system. The high flow system requires the use of large cellulose filters with the advantage that, increasing the amount of collected dust, the probability to collect asbestos fibers increases. Both the protocol of monitoring and analysis are novel and prompted by the need to increase the sensitivity towards the small number of expected fibers. With this goal, the collection of fall-out samples (the particulate falling into a collector filled with distilled water during the monitoring shift) and soil samples was also accomplished. The analytical protocol of the matrix particulate included preliminary X-ray powder diffraction (XRPD), optical microscopy and quantitative electron microscopy (SEM and TEM). Correlations with climatic trends and PM10 concentration data were also attempted.The surprising outcome of this work is that, despite the nature of the investigated site, the amount of dispersed asbestos fibers is very low and invariably lower than the theoretical method detection limits of the SEM and TEM techniques for identification and counting of asbestos fibers. The results are compared to the literature data worldwide and an updated model for asbestos fibers dispersion in ambient environments is proposed.  相似文献   

3.
The adverse effects of stratospheric ozone depletion on human health and welfare is a major environmental concern. One potential welfare effect is reduction in plant productivity, including agricultural crops, due to increased UV-B radiation and tropospheric ozone formation. This paper evaluates the economic effects of potential changes in crop yields due to hypothetical depletions in stratospheric ozone over regions of the U.S.A. Results suggest that increases in tropospheric ozone due to a 15 per cent stratospheric ozone depletion may cause economic losses of around 0·9 billion dollars. Combined effects of both tropospheric ozone and UV-B radiation range from 1·3 to 2·5 billion dollars. These estimates are preliminary, given the high degree of uncertainty in key plant science and aerometric data.  相似文献   

4.
Chambers are commonly used to measure the emission of many trace gases and chemicals from soil. An aerodynamic (flow through) chamber was designed and fabricated to accurately measure the surface flux of trace gases. Flow through the chamber was controlled with a small vacuum at the outlet. Due to the design using fans, a partition plate, and aerodynamic ends, air is forced to sweep parallel and uniform over the entire soil surface. A fraction of the air flowing inside the chamber is sampled in the outlet. The air velocity inside the chamber is controlled by fan speed and outlet suction flow rate. The chamber design resulted in a uniform distribution of air velocity at the soil surface. Steady state flux was attained within 5 min when the outlet air suction rate was 20 L/min or higher. For expected flux rates, the presence of the chamber did not affect the measured fluxes at outlet suction rates of around 20 L/min, except that the chamber caused some cooling of the surface in field experiments. Sensitive measurements of the pressure deficit across the soil layer in conjunction with measured fluxes in the source box and chamber outlet show that the outflow rate must be controlled carefully to minimize errors in the flux measurements. Both over- and underestimation of the fluxes are possible if the outlet flow rate is not controlled carefully. For this design, the chamber accurately measured steady flux at outlet air suction rates of approximately 20 L/min when the pressure deficit within the chamber with respect to the ambient atmosphere ranged between 0.46 and 0.79 Pa.  相似文献   

5.
Phosphorus removal in vegetated filter strips   总被引:5,自引:0,他引:5  
Vegetated filter strips (VFS) are used recently for removal, at or near the source, of sediment and sediment-bound chemicals from cropland runoff. Vegetation within the flowpath increases water infiltration and decreases water turbulence, thus enhancing pollutant removal by sedimentation within filter media and infiltration through the filter surface. Field experiments have been conducted to examine the efficiency of vegetated filter strips for phosphorus removal from cropland runoff with 20 filters with varying length (2 to 15 m), slope (2.3 and 5%), and vegetated cover, including bare-soil plots as control. Artificial runoff used in this study had an average phosphorus concentration of 2.37 mg L(-1) and a sediment concentration of 2700 mg L(-1). The average phosphorus trapping efficiency of all vegetated filters was 61% and ranged from 31% in a 2-m filter to 89% in a 15-m filter. Filter length has been found to be the predominant factor affecting P trapping in VFS. The rate of inflow, type of vegetation, and density of vegetation coverage had secondary influences on P removal. Short filters (2 and 5 m), which are somewhat effective in sediment removal, are much less effective in P removal. Increasing the filter length beyond 15 m is ineffective in enhancing sediment removal but is expected to further enhance P removal. Sediment deposition, infiltration, and plant adsorption are the primary mechanisms for phosphorus trapping in VFS.  相似文献   

6.
A solar still of a single basin-slope coupled with a finned condensing chamber and installed thermoelectric modules at the bottom of the water basin has been presented in this paper. A mathematical model under steady state conditions has been introduced and improved to investigate the system performance. An increase of solar radiation and ambient temperature or a decrease in wind velocity affect positively the distillation rate, the still efficiency, and the system efficiency. Integrating a condenser and finned condenser increases the distillation rate of the proposed system. The results of the simulation have been verified by comparing them with published theoretical and experimental results, and the comparison shows very good agreement.  相似文献   

7.
ABSTRACT: Rapid-rate filter with sand or anthracite as filter media was studied at filtration rates of 4.5 and 9.0 m3/m2-h. Different parameters were evaluated by adopting a proposed simplified model. A suitable combination of anthracite-sand as filter media was given by using corresponding filter parameters of single-medium filters and break-even optimization technique.  相似文献   

8.
ABSTRACT

In this paper, an improved kinetics model of soot oxidation based on the traditional B-K model is employed to characterize the thermal regeneration process of diesel particulate filters (DPF). Considering the influence of specific surface area and inhibition factor on soot oxidation, the regeneration process is simulated and analyzed using the commercial FLUENT software combined with UDF method. The results show that soot particles react from the middle of the filter to both ends, and the temporal profile of soot mass in the thermal regeneration process could be divided into three sections: smooth reaction, rapid reaction, and late reaction. The regeneration time decreases with the increasing of the incoming oxygen volume fraction. When the thickness of the deposited soot layer is less than 0.1 mm, the regeneration time is prolonged as the thickness of the deposited layer decreases. When the thickness is more than 0.1 mm, the regeneration time shows the opposite trend with the thickness of the deposited layer. Meanwhile, the curve of maximum wall temperature changing with time is divided into heating, rapid-burning, and slow-burning regimes. The maximum wall temperature increases as the volume fraction of oxygen flow increases, and as the deposited layer thickness increases.  相似文献   

9.
The present investigation involves theories, simulations and experiments on deposit layers on super-heater tubes in a circulating fluidised bed in Västerås in Sweden. Simulation of particle trajectories in the vicinity of two super-heater tubes is conducted in a Eulerian-Lagrangian mode for the flue gas and the ash particles from the combustion process. Particle impingements on the tubes are investigated for different particle sizes. Measurements of the buildup of deposit layers in the super-heater environment are conducted using a deposit probe. Deposit layer growth and growth rate is analysed for different probe temperatures, as well as the aspect of sintering on the probe ring surface. Analysis of the probe deposit material and deposits from the super-heaters and from textile filters are chemically analysed. The temperature dependence of the deposit materials viscosity is predicted from the chemical analysis of the samples. A model is included to simulate the effect of the deposit layer thickness on the tube heat exchange. The results from the particle trajectory simulations show that particle larger than 10 mm will mainly impinge on the front of the first tube and that smaller particles are more dispersed due to turbulence and thermophorectic forces, enabling a more even impingement on the whole surface of the tubes. The probe deposit layer growth measurements show significant temperature dependence. The deposit material sintering and distribution is proven to be dependent on; temperature, particle size and exposure time. The stickiness of the deposit material is shown to be dependent on the SiO2 and alkali relation in the samples, estimated through a viscosity model.  相似文献   

10.
高效纤维素分解菌复合系的构建及其环境适应性研究   总被引:1,自引:0,他引:1  
以纤维素培养基和纤维素刚果红培养基为初筛和复筛培养基,从采集的样品中分离得到具有纤维素分解能力的菌株20株。选择其中具有较高纤维素酶活力的12个菌株与2株自生固氮菌和EM菌进行正交实验,得到3个组合表现出协同降解纤维素的作用,对滤纸降解效果为组合12〉组合8〉组合5。选用组合12进行了一系列的环境适应性研究,结果表明,碳源为微晶纤维素+CMC-Na时CMC酶活最高,最适氮源为蛋白胨+酵母膏,最适pH6.5,最适培养温度为30℃。培养第6天CMC酶活最高。  相似文献   

11.
Renewed interest in quantifying greenhouse gas emissions from soil has led to an increase in the application of chamber-based flux measurement techniques. Despite the apparent conceptual simplicity of chamber-based methods, nuances in chamber design, deployment, and data analyses can have marked effects on the quality of the flux data derived. In many cases, fluxes are calculated from chamber headspace vs. time series consisting of three or four data points. Several mathematical techniques have been used to calculate a soil gas flux from time course data. This paper explores the influences of sampling and analytical variability associated with trace gas concentration quantification on the flux estimated by linear and nonlinear models. We used Monte Carlo simulation to calculate the minimum detectable fluxes (α = 0.05) of linear regression (LR), the Hutchinson/Mosier (H/M) method, the quadratic method (Quad), the revised H/M (HMR) model, and restricted versions of the Quad and H/M methods over a range of analytical precisions and chamber deployment times (DT) for data sets consisting of three or four time points. We found that LR had the smallest detection limit thresholds and was the least sensitive to analytical precision and chamber deployment time. The HMR model had the highest detection limits and was most sensitive to analytical precision and chamber deployment time. Equations were developed that enable the calculation of flux detection limits of any gas species if analytical precision, chamber deployment time, and ambient concentration of the gas species are known.  相似文献   

12.
The objective of the study was to investigate the importance of protozoan predation as a biological removal mechanism in sand filters used for purification of bacteria from wastewater. Eleven sand filter columns were seeded with a high dose of wastewater (70 mm d(-1)) and a high concentration (10(8) colony forming units [CFU] mL(-1)) of Aeromonas hydrophila (American Type Culture Collection [ATCC] 14715) for a period of 30 d. Water samples from three filter outlets were analyzed for the concentration of A. hydrophila. In addition, one filter column was sacrificed each sampling day for the quantification of A. hydrophila, culturable bacteria (heterotrophic plate counts, HPC), total bacterial counts, and protozoa in the sand. The mean removal efficiency of A. hydrophila in the sand filter columns was 4.7 log units. The concentration of A. hydrophila in the sand filter effluent, however, had a clearly time-dependent pattern from high (log 6) and unstable concentrations to low and more stable levels (log 2). The removal efficiency of A. hydrophila correlated significantly (P = 0.0005, r2 = 0.6) with numbers of protozoa in the sand filters. Significantly higher (P < 0.05) concentrations of A. hydrophila were observed in sand filter effluents from columns treated with the protozoan inhibitor cycloheximide, compared with nontreated columns. Results from the present study show that protozoan grazing plays an important role as a bacterial removal mechanism in sand infiltration systems.  相似文献   

13.
This paper examines the application of advanced computer image processing techniques integrated with communication technologies such as radio frequency identification (RFID), global positioning system (GPS), general packet radio system (GPRS), and geographic information system (GIS) with a camera for solving the problem of solid waste collection and automated bin level detection. A new method of bin level detection is proposed that uses a Gabor wavelet filter as a feature extractor. Taking advantage of the desirable characteristics of Gabor filters, such as mask size and frequency selectivity, we have designed four filters corresponding to different frequency values for the extraction of waste features from images of the bin. The feature vector output based on Gabor filters is used as the input of the classification algorithm, which is a feed-forward back propagation (BP) network. The effectiveness of the proposed method is demonstrated on a large number of images. Both the mask size and the frequency of the Gabor filter allow it to serve as a feature extractor, and the bin level detector with the Gabor wavelet filter in conjunction with the BP acts as a classifier to provide a robust solution for solid waste automated bin level detection, collection and management.  相似文献   

14.
简述了我国应对机动车污染防治的概况;针对柴油车污染后处理装置,指出流通式或部分流通式过滤器不能有效降低柴油车排气中的微粒数量,对微粒质量的降低比例也仅在50%左右,而壁流式微粒过滤器对超细微粒的分离效率超过90%,能有效解决超细微粒对公众健康的危害。  相似文献   

15.
Sediment is a major agricultural pollutant threatening water quality. Vegetated buffers, including vegetative filter strips, riparian buffers, and grassed waterways, are best management practices (BMPs) installed in many areas to filter sediments from tailwaters, and deter sediment transport to water bodies. Along with reducing sediment transport, the filters also help trap sediment bound nutrients and pesticides. The objectives of this study were: (i) to review vegetated buffer efficacy on sediment trapping, and (ii) to develop statistical models to investigate the major factors influencing sediment trapping. A range of sediment trapping efficacies was found in a review of over 80 representative BMP experiments. A synthesis of the literature regarding the effects of vegetated buffers on sediment trapping is needed. The meta-analysis results based on the limited data showed that buffer width and slope are two major factors influencing BMPs efficacy of vegetated buffers on sediment trapping. Regardless of the area ratio of buffer to agricultural field, a 10 m buffer and a 9% slope optimized the sediment trapping capability of vegetated buffers.  相似文献   

16.
Direct multicomponent analysis of malodorous volatile organic compounds (VOCs) present in ambient air samples from 29 swine (Sus scrofa) production facilities was used to develop a 19-component artificial swine odor solution that simulated olfactory properties of swine effluent. Analyses employing either a human panel consisting of 14 subjects or gas chromatography were performed on the air stream from an emission chamber to assess human olfactory responses or odorant concentration, respectively. Analysis of the olfactory responses using Fisher's LSD statistics showed that the subjects were sensitive to changes in air concentration of the VOC standard across dilutions differing by approximately 16%. The effect of chemical synergisms and antagonisms on human olfactory response magnitudes was assessed by altering the individual concentration of nine compounds in artificial swine odor over a twofold concentration range while maintaining the other 18 components at a constant concentration. A synergistic olfactory response was observed when the air concentration of acetic acid was increased relative to the concentration of other VOC odorants in the standard. An antagonistic olfactory response was observed when the air concentration of 4-ethyl phenol was increased relative to the other VOC odorants in the standard. The collective odorant responses for nine major VOCs associated with swine odor were used to develop an olfactory prediction model to estimate human odor response magnitudes to swine manure odorants through measured air concentrations of indicator VOCs. The results of this study show that direct multicomponent analysis of VOCs emitted from swine effluent can be applied toward estimating perceived odor intensity.  相似文献   

17.
Land-spreading and spray irrigation are the most widely used practices for the disposal of dairy wastewaters in Ireland but in some cases there can be problems due to contamination of surface and ground water. The use of intermittent sand filtration has been suggested as an alternative treatment process. However, a single pass through a sand filter limits denitrification because of the absence of reducing conditions following nitrification and the lack of an available carbon source. This leads to poor total nitrogen (TN) reduction and an effluent that is high in nitrate nitrogen (NO3-N). This paper follows a previous paper in which two instrumented stratified sand filter columns (0.9 and 0.425 m deep, and both 0.3 m in diameter) were intermittently loaded with synthetic dairy parlor washings at a number of hydraulic loading rates, leading to a TN reduction of 27 to 41%. In the present study, under a chemical oxygen demand (COD) of 23.4 g m(-2) d(-1), the TN was reduced by 83.2% when three-quarters of the sand filter effluent was recirculated through an anoxic zone. This produced an effluent NO3-N concentration of 60 mg L(-1). With recirculation, the improvement in the removal of organic matter and ammonia N (NH4-N) is minimal. Recirculating sand filters appear to offer a mechanically simple and effective method for the removal of nitrogen from dairy parlor effluents and are a significant improvement over a single-pass sand filter.  相似文献   

18.
19.
Improvement of the activity of anaerobic sludge by low-intensity ultrasound   总被引:1,自引:0,他引:1  
This paper aims to study the enhancement effect of low-intensity ultrasound on anaerobic sludge activity and the efficiency of anaerobic wastewater treatment. Dehydrogenate activity (DHA) and the content of coenzyme F(420) were detected to indicate the change of activity of anaerobic sludge induced by ultrasound at 35 kHz. Single-factor and multiple-factor optimization experiments showed that the optimal ultrasonic intensity and irradiation period were 0.2 W/cm(2) and 10 min, respectively, and the biological activity was enhanced dramatically under the optimal condition. The chemical oxygen demand (COD) removal efficiency was increased by ultrasonic treatment and the COD in the effluent was 30% lower than that of the control (without exposure). The hypothetical mechanism of biological activity enhancement by ultrasound was also discussed according to the results.  相似文献   

20.
Evaporative cooling of water in a small porous clay vessel was studied under controlled humidity conditions. In steady-state experiments performed at an ambient temperature of 23 °C, the cooling effect increased from 4.7 to 8.3 °C as the ambient relative humidity decreased from 60 to 15%. External heat and mass transfer coefficients, estimated from the steady-state measurements, were used in mathematical models to predict the experimentally observed transient temperature variation of the water under ramp changes of the ambient relative humidity. With a prototypical cool chamber containing water tested in Kolkata, India under an ambient temperature of 34.5–35 °C, the cooling effect reached a maximum of 7 °C between 3 and 3:30 PM and then declined to 4.5 °C around 6 PM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏