首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and efficient method has been developed for the simultaneous determination of 73 multi-class acidic pesticides, such as phenoxy acid and sulfonylurea herbicides, in vegetables and fruits. The sample preparation procedure was carefully optimized for the efficient removal of co-extracted matrix components. The method involves extraction of acidic pesticides with acetonitrile containing hydrochloric acid, removal of water from crude extract by salting out, and sequential cleanup by octadecylsilyl silica gel and silica gel columns. For samples containing high amounts of pigments, such as spinach, additional cleanup using a graphitized carbon column was performed prior to liquid chromatography–mass spectrometry (LC–MS/MS) analysis. Recovery tests were performed for five times for each sample of cabbage, spinach, potato, eggplant, orange, and apple fortified at 0.01 mg kg?1. Out of the 73 tested pesticides, 70 for cabbage, 67 for spinach, 69 for potato, 67 for eggplant, 64 for orange, and 70 for apple were within the range of 70–120%, with relative standard deviations below 25%. Nitenpyram and pyrasulfotole showed low recoveries for all the samples tested, probably due to low recoveries from silica gel column. The developed method effectively removed co-extracted matrix components and was highly selective, with no interfering peaks found in the chromatograms of blank samples. The overall results indicate that the developed method is suitable for the quantitative analysis of acidic pesticide residues in vegetables and fruits.  相似文献   

2.
A multiresidue method was developed to determine 19 carbamate pesticides in tea samples. Optimizations of different parameters, such as the type of extraction solvents, clean-up cartridges, and elution solvents were carried out. The developed method used acetonitrile as extraction solvent, amino cartridge for adsorbents and acetone-n-hexane as the eluting solution. Nineteen carbamate residues were then analyzed by high-pressure liquid chromatography (HPLC) with fluorescence detector. The present results showed good linearity by correlation coefficients of more than 0.9999 for all analyses. Limits of detection and quantification varied from 0.0005–0.023 mg L? 1, 0.008–0.077 mg L? 1, respectively. Recoveries of sixteen carbamate pesticides ranged from 65% to 135% at the spiked level of 0.5, 1.0 and 2.0 mg L? 1. The relative standard deviations were lower than 20% and coefficient of variations were lower than 15%. The results indicate that the proposed method provides an effective multi and trace level screening determination of carbamate pesticides residues for tea samples.  相似文献   

3.
The aim of the research is to evaluate pesticide residue contamination of fresh and frozen fruits and vegetables, agricultural raw material, purchased from Polish farmers for production of frozen fruits and vegetables, and the estimation of the multiresidue method effectiveness expressed as the proportion of pesticides detected in food samples to the total number of pesticides analyzed by multiresidue methods. A total of 144 samples (of black currants, red currants, raspberries, cherries, strawberries, blackberries, cauliflowers and broccoli) were analyzed using LC-MS/MS method for the determination of 60 pesticides. QuEChERS extraction, matrix-matched calibration and dynamic multiple reaction monitoring method were used. Residues of 15 compounds, mainly fungicides and insecticides, were detected in 46 samples. The percentage of samples with residues above the maximum residue levels (MRL) was 15%, whereas samples with residues below MRL were 17%. A total of 13 samples contained more than one pesticide residue. Pesticide residues were detected most often in samples of black currants (50%), broccoli (36.4%), raspberries (29%) and red currants (21.8%). The most frequently detected pesticides were carbendazim and acetamiprid. The proportion of pesticides detected during our study to the total number of analyzed pesticides amounted to 25%. It was compared to literature findings. For three fourth of multiresidue methods, the proportion was below 50% for methods developed for the analysis of less than 100 pesticides, and below 30% for methods developed for the analysis of more than 100 pesticides. It appears that a lot of efforts and means is lost on pesticides never or rarely detected in examined samples. The workload and cost effectiveness of the development and application of multiresidue methods along with the range of pesticides covered by the method should be carefully and thoroughly considered anytime when a new method or workflow is developed. Including non-targeted screenings in pesticide residue control seems to be an alternative worth considering.  相似文献   

4.
A multiresidue method for the analysis of 86 persistent pollutants in marine sediments at ultra-trace level has been developed and validated using pressurized liquid extraction (PLE) and stir-bar sorptive extraction (SBSE) coupled with thermal desorption and gas chromatography-triple quadrupole mass spectrometry (TD-GC-MS/MS QqQ). The compounds analyzed belong to various families such as polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polybrominated diphenylethers, organophosphorus and organochlorine pesticides and other pesticides such as urons, and triazines. The analytes have very different polarities and log Kow values, which is an important parameter in the optimization of a SBSE method. Due to PLE high efficiency and throughput rates, along with the proven ability for multiresidue analysis and excellent sensitivity of SBSE, we present an efficient method. The limits of quantification obtained ranged from 0.014 to 1.0 ng g−1, with detection limits below pg g−1 levels. In order to validate the proposed methodology, quality parameters such as recovery, linearity and reproducibility were studied. Recoveries ranged from 63% to 119%, reproducibility (in terms of Relative Standard Deviation for ten determinations) was lower than 35% in all cases, and determination coefficients higher than 0.990 for all analytes. The main factors that affect PLE, SBSE and GC-MS/MS procedures were optimized. The method was applied to the analysis of nine marine sediments obtained from the nine main submarine wastewater discharge points (emissaries) presents along the coast of Tenerife Island (Canary Islands, Spain).  相似文献   

5.
A multiresidue analysis of 50 pesticides has been developed as a rapid screening method for organic contaminants in water samples. Solid phase extraction was accomplished with two adsorbents in a single column. Simultaneous analysis was performed with gas chromatography-mass spectrometry (GC-MS). The limits of detection for each pesticide are at sub-ppb levels. This method was used to check contamination of water from the Adige river (Northern Italy).  相似文献   

6.
Abstract

Nine different C18 solid‐phase extraction (SPE) cartridges were evaluated for their efficiency at extracting nine pesticides and two s‐triazine metabolites from spiked deionized water samples. The SPE cartridges were found to contain nitrogen (N) and/or phosphorus (P) contaminants and varied in their extraction efficiency for certain pesticides and metabolites. Four of the nine SPE cartridges gave acceptable (70 to 120%) pesticide and metabolite recovery percentages, while five cartridges had marginal (50 to 70%) to poor (< 50%) recoveries. Statistical analyses showed that the poor to marginal recoveries found for three compounds could not be explained by considering several indigenous chemical and physical traits of the cartridge. It is suggested that proper SPE cartridge selection for pesticide recovery should be evaluated using several different cartridges.  相似文献   

7.
A simultaneous method for quantifying eight metabolites of organophosphate pesticides and pyrethroid pesticides in urine samples has been established. The analytes were extracted using liquid–liquid extraction coupled with WCX solid phase extraction (SPE) cartridges. Eight metabolites were chemically derivatized before analysis using gas chromatography–tandem mass spectrometry (GC–MS–MS). The separation was performed on a HP-5MS capillary column (30 m × 0.25 mm × 0.25 µm) with temperature programming. The detection was performed under electro-spray ionization (ESI) in multiple reaction monitoring (MRM) mode. An internal standard method was used. The extraction solvent, types of SPE cartridges and eluents were optimized by comparing the sample recoveries under different conditions. The results showed that the calibration curves of the five organophosphorus pesticides metabolites were linear in the range of 0.2–200 μg/L (r2 ≥ 0.992) and that of the three pyrethroid pesticides metabolites were linear in the range of 0.025–250 μg/L (r2 ≥ 0.991). The limits of detection (LODs, S/N ≥ 3) and the limits of quantification (LOQs, S/N ≥ 10) of the eight metabolites were 0.008–0.833 μg/L and 0.25–2.5 μg/L, respectively. The recoveries of the eight metabolites ranged from 54.08% to 82.49%. This efficient, stable, and cost-effective method is adequate to handle the large number of samples required for surveying the exposure level of organophosphorus and pyrethroid pesticides in the general population.  相似文献   

8.
This paper reports the results of studies performed to investigate the potential of applying thin layer chromatography (TLC) detection in combination with selected extraction and cleanup methods, for providing an alternative cost-effective analytical procedure for screening and confirmation of pesticide residues in plant commodities. The extraction was carried out with ethyl acetate and an on-line extraction method applying an acetone-dichloromethane mixture. The extracts were cleaned up with SX-3 gel, an adsorbent mixture of active carbon, magnesia, and diatomaceous earth, and on silica micro cartridges. The Rf values of 118 pesticides were tested in eleven elution systems with UV, and eight biotest methods and chemical detection reagents. Cabbage, green peas, orange, and tomatoes were selected as representative sample matrices for fruits and vegetables, while maize, rice, and wheat represented cereal grains. As an internal quality control measure, marker compounds were applied on each plate to verify the proper elution and detection conditions. The Rf values varied in the different elution systems. The best separation (widest Rf range) was achieved with silica gel (SG)--ethyl acetate (0.05-0.7), SG--benzene, (0.02-0.7) and reverse phase RP-18 F-254S layer with acetone: methanol: water/30:30:30 (v/v) (0.1-0.8). The relative standard deviation of Rf values (CV(Rf)) within laboratory reproducibility was generally less than 20%, except below 0.2 Rf, where the CVRf rapidly increased with decreasing Rf values. The fungi spore inhibition, chloroplast inhibition, and enzyme inhibition were found most suitable for detection of pesticides primarily for confirming their identity or screening for known substances. Their use for determination of pesticide residues in samples of unknown origin is not recommended.  相似文献   

9.
以白碳黑、硅灰、硅藻土和硅胶筛选硅质原料,并与钙质原料电石渣制备了水化硅酸钙。借助XRF、BET、FT—IR等表征手段,通过多次重复除磷实验,研究了硅质原料特性对水化硅酸钙回收磷性能的影响。结果表明,白碳黑具有极高的反应活性,因此可作为制备具有磷回收特性的水化硅酸钙的硅质原料。结合XRD等表征发现,白碳黑的有效利用率是影响水化硅酸钙回收磷性能的关键,该利用率取决于白碳黑与电石渣的摩尔配比以及水热反应温度。当电石渣与白碳黑的摩尔比为1.6:1,反应温度为170℃时,白碳黑具有最佳的利用效率。该条件制备的水化硅酸钙可作为晶种,在其表面结晶形成羟基磷灰石,从而达到磷回收的目的,磷回收后固体物质中的磷含量为19.05%。  相似文献   

10.
A simple, sensitive, reliable method was developed for the simultaneous determination of organochlorine and pyrethriod pesticide residues in Chinese patent medicines Six ingredient rehmannia pills and Xiaoyao pills. These pesticides were extracted by ethyl acetate. The extraction time and volume of ethyl acetate were optimized. Cleanup of extracts was performed with dispersive-solid phase extraction using graphitized carbon black as the sorbent. The determination of pesticides in the final extracts was carried out by gas chromatography–tandem mass spectrometry in multiple reaction monitoring mode (GC-MS/MS, MRM). The linearity of the calibration curves is good in matrix-matched standard and yields the coefficients of determination (R2) ≥0.99 for all of the target analytes. Under optimized conditions, the average recoveries (five replicates) for most pesticides range from 75.5% to 114.6%, and RSDs are less than 10.0%. The LODs of 18 pesticides in Six ingredient rehmannia pill and Xiaoyao pills are in the range of 0.01–8.82 μg kg?1. The developed method meets the requirements of pesticide residue analysis and could be effectively used for routine analysis of the organochlorine and pyrethriod pesticide residues in Six ingredient rehmannia pills and Xiaoyao pills.  相似文献   

11.
ABSTRACT

A simple high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) multiresidue analysis method was developed for the simultaneous determination of polar pesticides, plant growth regulators and other polar compounds. These included amitrole, chlormequat, mepiquat, cyromazine, ETU, PTU, perchlorate, and daminozide using a mixed-mode column. A 10 g test portion was shaken with acidified methanol for 10 min. After centrifugation, the sample extract was injected and analyzed within 11 min by LC-MS-MS. This column eliminated the need for derivatization or the use of ion paring reagent. Two MS-MS transitions were monitored in the method for each target compound to achieve true positive identification. Eight isotopically-labeled internal standards corresponding to each analyte were used to correct for matrix suppression effect and/or instrument signal drift. The average recovery for all analytes at 20, 40, and 250 ng/g (n = 6) ranged from 73–136%, with a relative standard deviation of ≤ 20%.  相似文献   

12.
Maaret Kulovaara 《Chemosphere》1993,27(12):2333-2340
DDT and benzo[a]pyrene (BaP) were added both separately and as a mixture to filtered (0.22 μm) humic surface water samples. Following a contact time of 1 d, the fraction bound to dissolved organic matter and the freely dissolved part were separated by using reversed-phase octadecyl silica cartridges. The enriched solutes were analysed by gas chromatography-mass spectrometry in the selective ion monitoring (GC-MS/SIM) mode. Partition coefficients to dissolved organic matter, calculated on the basis of the recovery data, varied between 2.0 × 104 and 6.6 × 104 mL/g for BaP depending on the experimental conditions, whereas the corresponding values for DDT (0.6 × 104 mL/g) showed no significant variation.  相似文献   

13.
An analytical method was developed and tested for the simultaneous determination of chlorothalonil and its main metabolite 4-hydroxychlorothalonil, in airborne samples. High performance liquid chromatography equipped with Ultra-violet detector was used to separate and quantify the analytes. Glass microfibre filters for the collection of the analytes' particles were tested. Solid sorbents, such as Tenax, Florisil, XAD-2 and silica gel, were studied to find out the most suitable material for the collection of the analytes in the gas phase. The results have shown that only chlorothalonil was trapped in the vapor phase with highest results obtained when silica gel was the sorbent of choice. Linearity was demonstrated in a wide concentration range 0.01-10.00 mg L(-1). Recoveries from spiked glass microfibre filters and silica gel cartridges for chlorothalonil and 4-hydroxychlorothalonil were almost quantitative. The quantification limits were calculated to be 8.4 and 19.6 ng m(-3) in air for chlorothalonil and 4-hydroxychlorothalonil, respectively. The two analytes spiked on the GF/A filters and silica gel cartridges were proven to be stable for more than 15 days, at 4degrees C and ambient temperature. The applicability of the present method was demonstrated by the analysis of the chlorothalonil and its metabolite in greenhouse air.  相似文献   

14.
《Chemosphere》1987,16(5):1065-1069
Quantitative recovery of some organophosphorus pesticide residues has not been possible with existing silica gel-cleanup procedures. We have developed a modification that permits quantitative recovery of all organophosphorus pesticides tested except those with a carbamate functional group. The method uses a 3.5 g silica gel column with a 1% acetic acid wash to condition the column prior to the addition of the sample. Percentage recovery and standard deviation of compounds such as phorate and disulfoton are 96 (5.6) and 98 (1.0) respectively. Recoveries range from 92 to 101% for the 11 compounds tested.  相似文献   

15.
In this study, an enzyme-linked immunosorbent assay (ELISA) was optimized and applied to the determination of endosulfan residues in 20 different kinds of food commodities including vegetables, dry fruits, tea and meat. The limit of detection (IC(15)) was 0.8 microg kg(-1) and the sensitivity (IC(50)) was 5.3 microg kg(-1). Three simple extraction methods were developed, including shaking on the rotary shaker at 250 r min(-1) overnight, shaking on the rotary shaker for 1 h and thoroughly mixing for 2 min. Methanol was used as the extraction solvent in this study. The extracts were diluted in 0.5% fish skin gelatin (FG) in phosphate-buffered saline (PBS) at various dilutions in order to remove the matrix interference. For cabbage (purple and green), asparagus, Japanese green, Chinese cabbage, scallion, garland chrysanthemum, spinach and garlic, the extracts were diluted 10-fold; for carrots and tea, the extracts were diluted 15-fold and 900-fold, respectively. The extracts of celery, adzuki beans and chestnuts, were diluted 20-fold to avoid the matrix interference; ginger, vegetable soybean and peanut extracts were diluted 100-fold; mutton and chicken extracts were diluted 10-fold and for eel, the dilution was 40-fold. Average recoveries were 63.13-125.61%. Validation was conducted by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). The results of this study will be useful to the wide application of an ELISA for the rapid determination of pesticides in food samples.  相似文献   

16.
A multiresidue method was assessed for the determination of several pesticides (organochlorine, organophosphorus, pyrethroids, triazole, amidine) using gas chromatography/mass spectrometry. The extraction of pesticides was carried out by liquid-liquid extraction (LLE) and solid-phase extraction (SPE) using two types of columns (CN and C18). The extracts were cleaned by the addition of florisil, the pesticides were separated by capillary column gas chromatography and detected by mass spectrometry in the electron impact mode. The extraction using C18 column provided the best results for most of the analyzed pesticides. The majority of pesticides recoveries from the four fruits and vegetables (apples, pears, tomatoes and pepper) were greater than 60%. Linearity and precision were satisfactory. The estimated limits of detection and limits of quantification ranged from 0.01 to 0.1 mg/kg and from 0.02 to 0.3 mg/kg, respectively. The proposed procedure was found to be useful for the multiresidue analyses of pesticides in agricultural products for routine monitoring programs.  相似文献   

17.
Atmospheric samples have been collected between 14 March and 12 September 2012 on a 2-week basis (15 days of sampling and exchange of traps each 7 days) in Strasbourg (east of France) for the analysis of 43 pesticides. Samples (particle and gas phases) were separately extracted using Accelerated Solvent Extraction (ASE) and pre-concentrated by Solid Phase Micro-Extraction (SPME) before analysis by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). Four SPME consecutive injections at distinct temperatures were made in order to increase the sensitivity of detection for the all monitored pesticides. Currently used detected pesticides can be grouped in four classes; those used in maize crops (acetochlor, benoxacor, dicamba, s-metolachlor, pendimethalin, and bromoxynil), in cereal crops (benoxacor, chlorothalonil, fenpropimorph, and propiconazole), in vineyards (tebuconazole), and as herbicides for orchards, meadows of green spaces (2,4-MCPA, trichlopyr). This is in accordance with the diversity of crops found in the Alsace region and trends observed are in accordance with the period of application of these pesticides. Variations observed permit also to demonstrate that the long time sampling duration used in this study is efficient to visualize temporal variations of airborne pesticides concentrations. Then, long time high-volume sampling could be a simple method permitting atmospheric survey of atmospheric contamination without any long analysis time and consequently low cost.  相似文献   

18.
A multiresidue method was assessed for the determination of several pesticides (organochlorine, organophosphorus, pyrethroids, triazole, amidine) using gas chromatography/mass spectrometry. The extraction of pesticides was carried out by liquid-liquid extraction (LLE) and solid-phase extraction (SPE) using two types of columns (CN and C18). The extracts were cleaned by the addition of florisil, the pesticides were separated by capillary column gas chromatography and detected by mass spectrometry in the electron impact mode. The extraction using C18 column provided the best results for most of the analyzed pesticides. The majority of pesticides recoveries from the four fruits and vegetables (apples, pears, tomatoes and pepper) were greater than 60%. Linearity and precision were satisfactory. The estimated limits of detection and limits of quantification ranged from 0.01 to 0.1 mg/kg and from 0.02 to 0.3 mg/kg, respectively. The proposed procedure was found to be useful for the multiresidue analyses of pesticides in agricultural products for routine monitoring programs.  相似文献   

19.
Abstract

Maize consists of a cereal widely used in the preparation of different food products. Brazil is one of the world's largest maize producers. Several types of pesticides have been applied in maize crop, which can lead to the contamination of the derived products. The present work aims at the validation of multiresidue method to analyze the matrix effect and level of pesticides in maize flour. Twenty residues were investigated in samples commercialized in the state of Ceará, Brazil. The method was satisfactorily validated, according to parameters recommended by European Union. About 55% of the pesticides had an intense negative matrix effect. Multiresidue analyzes showed the presence of traces of fenitrotion in 20% of maize flour samples. Detected levels were below maximum residue limits recommended for maize. The results indicate that maize products need continuous monitoring to ensure food security.  相似文献   

20.
A multiresidue solid-phase extraction (SPE) method for the isolation and subsequent gas chromatographic determination of organochlorine and organophosphorus pesticide residues in low-moisture, nonfatty products is described. Residues are extracted from samples with an acetonitrile/water mixture. Cleanup of the extract is performed using graphitized carbon black and anion exchange SPE columns, and analysis is performed by gas chromatography with Hall electrolytic conductivity and flame photometric detection. Recovery data was obtained by fortifying corn, oats and wheat with pesticides. The average recoveries were 79-123% for eight organochlorine and 51-122% for 28 organophosphorus pesticide residues. The limit of quantitation for chlorpyriphos was 0.05 ppm using the Hall electrolytic conductivity detector and < 0.005 ppm using the flame photometric detector.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号