首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Evaluation and analysis of noise pollution levels have been carried out to determine the level of noise and its sources in Ilorin metropolis. Noise measurements have been done in the morning, at noon, in the evening, and at night to determine noise pollution all over the city. The selected areas of study are commercial centers, road junctions/busy roads, passenger loading parks, and high-density and low-density residential areas. The road junctions had the highest noise pollution levels, followed by commercial centers. The results of this study show that the noise levels in Ilorin metropolis exceeded allowed values at 30 of 42 measurements points. There is a significant difference (P?<?0.05) in the noise pollution levels and traffic noise index in all the locations. From the measured noise values, a map of noise pollution was developed for Ilorin. Many solutions proposed for noise abatement in the city are set out.  相似文献   

2.
The aim of the study is to investigate how environmental factors, associated with exposure to industrial noise, affect the development of chronic noise-induced hearing loss.The studywas conducted on 186 male subjectsworking in two bottling plants, situated respectively in a small farming community, and in a medium-sized city with significant levels of noise pollution. Levels of occupational exposure were the same for the two groups.The subjects were selected by means of a preliminary medical examination, and exposed to tonal hearing tests and acoustic impedance tests. Statistical analysis was performed on hearing threshold values obtained at the frequencies of 500, 1000, 2000 and 4000 Hz.The comparison between the thresholds obtained in the two groups showed a statistically significant difference, especially at the frequency of 4000 Hz and for occupational exposure exceeding 17 yr. The results led us to conclude that environmental factors, and urban noise in particular, influence the onset and development of occupational acoustic trauma, and that those working in the country are significantly less affected than those in the city. Since occupational exposure was the same for both groups, their different responses must therefore be interpreted as due to differences in nonoccupational exposure, in turn dependent on different opportunities for rest from noise and different levels of exposure to noise pollution.  相似文献   

3.
This study aimed to determine the levels of placental cadmium (PCd) and cord blood cadmium (CBCd) and the resulting expression of placental metallothionein (MT) in neonates and to investigate cadmium (Cd) exposure levels in neonates and mothers who live in Guiyu, China, an electronic waste (e-waste) pollution site. Among the 423 mothers included in the study from 2004/2005 to 2007, 289 lived in Guiyu (exposed group) and 134 lived in Chaonan, located 10 km away from Guiyu (controls) and had never been exposed to e-waste pollution. CBCd and PCd levels were measured by atomic absorption spectrometry. Placental MT was examined by immunohistochemistry. Information on maternal and neonatal characteristics and exposure conditions was obtained from hospital records and by personal interviews. For the 3 years, the median CBCd was higher for Guiyu neonates than for controls (3.61 vs. 1.25 ??g/L), with 25.61% of Guiyu subjects exhibiting a median CBCd that exceeded the safety limit defined by the World Health Organization (5 ??g/L), as compared with 14.18% of control neonates (p < 0.01). In Guiyu, the mean PCd was higher than that for controls (0.17 ± 0.48 vs. 0.10 ± 0.11 ??g/g, p ?? 0.01). The high levels of CBCd and PCd were significantly associated with parents?? occupational and environmental exposure to e-waste recycling pollutants. Staining for MT was positive and dense for 67.00% (67/100) of Guiyu neonates as compared with 32.69% (17/52) of controls (p < 0.01). Exposure to e-waste recycling pollutants increased Cd exposure in neonates, which was accompanied by increased placental MT expression.  相似文献   

4.
CO concentrations were measured in five kindergartens, one children's hospital and two homes for aged, practically without indoor sources, all situated in the city centre, for ten random days in winter and ten in summer. The indoor CO concentrations were the result of the distance from and the traffic density in the nearest street, of general pollution level, seasonal differences, day-to-day variations and daily cycle of air pollution, the vicinity of traffic having a dominant influence. Therefore location of institutions for sensitive population groups in old city centres within a block of houses seems to be a suitable solution as far as exposure to CO is concerned.Revised version of a paper presented as poster at the VIth World Congress on Air Quality, Paris 1983.  相似文献   

5.
The noise pollution is a major problem for the quality of life in urban areas. This study was conducted to compare the noise pollution levels at busy roads/road junctions, passengers loading parks, commercial, industrial and residential areas in Ilorin metropolis. A total number of 47-locations were selected within the metropolis. Statistical analysis shows significant difference (P < 0.05) in noise pollution levels between industrial areas and low density residential areas, industrial areas and high density areas, industrial areas and passengers loading parks, industrial areas and commercial areas, busy roads/road junctions and low density areas, passengers loading parks and commercial areas and commercial areas and low density areas. There is no significant difference (P > 0.05) in noise pollution levels between industrial areas and busy roads/road junctions, busy roads/road junctions and high density areas, busy roads/road junctions and passengers loading parks, busy roads/road junctions and commercial areas, passengers loading parks and high density areas, passengers loading parks and commercial areas and commercial areas and high density areas. The results show that Industrial areas have the highest noise pollution levels (110.2 dB(A)) followed by busy roads/Road junctions (91.5 dB(A)), Passengers loading parks (87.8 dB(A)) and Commercial areas (84.4 dB(A)). The noise pollution levels in Ilorin metropolis exceeded the recommended level by WHO at 34 of 47 measuring points. It can be concluded that the city is environmentally noise polluted and road traffic and industrial machineries are the major sources of it. Noting the noise emission standards, technical control measures, planning and promoting the citizens awareness about the high noise risk may help to relieve the noise problem in the metropolis.  相似文献   

6.
Epidemiological studies typically use monitored air pollution data from a single station or as averaged data from several stations to estimate population exposure. In industrialized urban areas, this approach may present critical issues due to the spatial complexities of air pollutants which are emitted by different sources. This study focused on the city of Taranto, which is one of the most highly industrialized cities in southern Italy. Epidemiological studies have revealed several critical situations in this area, in terms of mortality excess and short-term health effects of air pollution. The aims of this paper are to study the variability of air pollutants in the city of Taranto and to interpret the results in relation to the applicability of the data in assessing population exposure. Meteorological and pollution data (SO2, NO2, PM10), measured simultaneously and continuously during the period 2006–2010 in five air quality stations, were analyzed. Relative and absolute spatial concentration variations were investigated by means of statistical indexes. Results show significant differences among stations. The highest correlation between stations was observed for PM10 concentrations, while critical values were found for NO2. The worst values were observed for the SO2 series. The high values of 90th percentile of differences between pairs of monitoring sites for the three pollutants index suggest that mean concentrations differ by large amounts from site to site. The overall analysis supports the hypothesis that various parts of the city are differently affected by the different emission sources, depending on meteorological conditions. In particular, analysis revealed that the influence of the industrial site may be primarily identified with the series of SO2 data which exhibit higher mean concentration values and positive correlations with wind intensity when the monitoring station is downwind from the industrial site. Results suggest evaluating the population exposure to air pollutants in industrialized cities by taking into account the possible zones of influence of different emission sources. More research is needed to identify an indicator, which ought to be a synthesis of several pollutants, and take into account the meteorological variables.  相似文献   

7.
生物综合毒性分析仪的毒性测试方法及适用范围研究   总被引:4,自引:2,他引:2  
比较研究了三种常用便携式生物综合毒性分析仪测定重金属及有机污染的灵敏度,初步提出了仪器使用注意事项及建议使用范围。结果表明,基于生物发光原理的Toxscreen-II和Deltatox仪器对重金属污染敏感,Toxscreen-II测得Hg、Cr(VI)、As的EC50值分别为0.0082、0.07、4.41mg/L;基于化学发光原理的Eclox对有机污染敏感,Eclox的EC50(苯酚)为1.21mg/L。鉴于综合毒性分析仪中等毒性检测限高于我国地表水标准限值,建议该类仪器更适用于环境污染事故中污染水体的毒性初筛判定。  相似文献   

8.
Samples of Jerusalem limestones were exposed to high levels of common air pollutants (SO2, NO) in the presence and absence of hydrocarbon, water vapor and ultra-violet light. After exposure, the outer layers were shaved off and analyzed for sulfate and nitrate. The results revealed that even after one day of exposure significant concentrations of CaSO4 and Ca(NO3)2 could be detected in the external 40 m layers. Sulfate formation was found to relate very strongly to relative humidity with nearly undetectable production at humidities below 10%. Nitrate formation was found to relate to UV light and to a limited extent to the presence of hydrocarbon but was unchanged at different humidities. Surface samples were taken from different sites of the old city wall and were also analyzed for the same substances. The data showed that the concentrations of especially CaSO4, and to a limited extend Ca(NO3)2, measured at various points along the city walls were higher than the expected values extrapolated from laboratory simulations. The elevated pollution content may be explained in part due to the deposition of transported ions, especially sulfate, onto the stone surface. It was concluded that although air pollution may not cause any structural damage in the foreseeable future it definitely deteriorates the fine details of the ancient monument.  相似文献   

9.
Copacabana is one of the most famous neighborhoods of the city of Rio de Janeiro/Brazil but suffers from a high inhabitant density. One of the many environmental problems faced is related to noise pollution. In order to assess not only the noise levels, to which the population is exposed, but also to quantify the influence of architectural aspects, the paper presents the steps taken towards a simulation of the noise emission and propagation in this area. The results of the simulation are compared to measurements in different locations and daily-hours. The discrepancies are analyzed and the methodology is discussed in view of its application to a huge urban center like the city of Rio de Janeiro.  相似文献   

10.
Carbon monoxide concentrations were measured in six shops situated in narrow busy streets of the city centre for ten days in winter and ten days in summer and correlated with the measurements simultaneaously performed at an outdoor background reference point. The correlation was significant for four out of six shops in winter, but not in summer. Day-to-day variations seemed to be influenced by gross contamination due to changing weather conditions whereas differences in concentration levels from site to site were strongly influenced by the proximity and density of traffic. The exposure of a pedestrian in winter was in good correlation with background outdoor levels and it was considerably lower than that of a car driver driving though the city.  相似文献   

11.
对南通市楼顶式移动基站电磁辐射污染进行了调查。结果表明,南通市418个楼顶站基站周边地面50 m范围内电磁辐射功率密度值均能满足《电磁环境控制限值》(GB 8702—2014)的要求;楼顶美化天线、集束天线和景观塔等建设较晚的楼顶塔形地面电磁辐射强度相对较小,楼顶角钢塔、拉线塔和抱杆等建设较早的塔形地面电磁辐射强度相对较大;楼顶塔所在楼顶平台监测值存在轻度超标的情况。提出,应严格控制楼顶塔所在楼顶的人员可达性,即基站电磁辐射防护区应高出楼顶2 m以上,避免公众进入基站电磁辐射防护区内,受到基站天线的过量辐射影响。  相似文献   

12.
移动通信网基站电磁辐射调研及居民环境超标原因分析   总被引:2,自引:0,他引:2  
对北京市区近 2 0 0个移动电话基地站电磁辐射进行了测试 ,结合基地站电磁辐射特征对电磁辐射超标原因进行分析。从规划布局、天线架设规范方面提出了减小移动电话基地站电磁辐射污染的对策  相似文献   

13.
Sulphur dioxide and PM10 levels are investigated in Erzurum during the periods of 1990–2000 heating season to assess air pollution level. For that reason, emissions of sulphur dioxide and particulate matter were calculated by using consumption of fuels and Turkish emission factors. These emission values were evaluated together with air pollution levels, which were measured at six stations in Erzurum atmosphere during 1990–2000 winter periods. Results reveal that in 1990–1994 heating period, there is an increasing trend in the emissions and air pollution levels over Erzurum, and the air quality limits were not met. The daily 24 h limit (short-term limit) was exceeded 127 days in 1992–1993 winter period. The reason for this increase was found to be the switching to use of low-quality fossil fuels instead of cleaner ones. Results also indicated that there was a considerable decrease in emissions of air pollutants and air pollution levels after 1995. This can be explained by the consumption of more high-quality fossil fuels. The correlation coefficient of SO2 with PM10 is obtained as r2 = 0.85, which is a high value supporting the idea that both pollutants are emitted from the same source.  相似文献   

14.
以齐齐哈尔市近30年地表水生物监测数据、理化监测数据为研究依据,提出一套基于指示生物的地表水体评价方法。该方法将地表水体划分为5个级别,并从中筛选出每个级别对应的指示生物,最终建立一套基于指示生物描述水体污染程度的评价体系。该方法以理化指标为基础,筛选多种优势种作为指示生物,对水体进行综合评价。相比单一生物监测评价指标,该评价方法更能反映整个生态系统状况,从而更客观地反映水体真实情况,有望为地表水体污染评价新方法的建立提供参考。  相似文献   

15.
The aim of this study was to assess the pollution status of metals in sediments of Hara Biosphere Reserve using pollution indicators. For this purpose, sediment samples from nine locations were collected and characterized for metal content (Pb, Cr, Zn, Cu, and Fe) using the total digestion technique. Comparison of metal concentrations with that of sediment quality guidelines (SQGs) demonstrated no association with negative biological effects for Cu and Zn, while the values of Pb and Cr mainly illustrated to have association with negative biological effects. The results of the geo-accumulation index (I geo) indicated no contamination for Cr, Cu, Zn, and Fe, while the values of Pb demonstrated to have moderate contamination based on I geo values. The analysis of the enrichment factor (EF) showed no enrichment for Cu and Zn and minor enrichment for Pb and Cr. Similar results were also found for quantification of contamination (QoC) analysis, where the values of Cu and Zn demonstrated to have a geogenic source of contamination, while the values of Pb and Cr mainly illustrated to have an anthropogenic source of contamination. According to EF and QoC calculations, the values of Cu and Zn were derived mainly from natural processes and exposure of material from the earth’s crust, while the values for Pb and Cr were enriched by anthropogenic activities. The results of the contamination factor (C f i ) demonstrated low contamination levels for Fe, Cr, Zn, and Cu and moderate contamination levels for Pb. The pollution load index (PLI), showing the overall contamination of metals, demonstrated moderate pollution status in the study area.  相似文献   

16.
This study describes the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils, among ground personnel within the aviation industry. The OPs tri-n-butyl phosphate (TnBP), dibutyl phenyl phosphate (DBPP), triphenyl phosphate (TPP) and tricresyl phosphate (TCP) have been emphasized due to their use in such oils. Oil aerosol/vapor and total volatile organic compounds (tVOCs) in air were also determined. In total, 228 and 182 OPs and oil aerosol/vapor samples from technician and loader work tasks during work on 42 and 21 aircrafts, respectively, were collected in pairs. In general, the measured exposure levels were below the limit of quantification (LOQ) for 84%/98% (oil aerosol) and 82%/90% (TCP) of the samples collected during technician/loader work tasks. The air concentration ranges for all samples related to technician work were 相似文献   

17.
In recent years, the level of heavy metal pollution in urban areas has been of considerable concern. The principal source has been attributed to the motor vehicle and increasing inner city congestion, which has lead to a change and enlargement of transport stop-start zones. These areas of high traffic density are associated with an increased release of heavy metals into the adjacent residential or commercial areas. Seventy-five roadside dust samples were collected throughout the inner city and by-pass motorway areas of Thessaloniki, Northern Greece. Samples were taken from arterial, major and minor roads, as well as the ring road, to compare and contrast the levels of heavy metals, namely Cu, Zn, Cd, Mn and Pb. Flame Atomic Absorption Spectroscopy (FAAS) was developed to quantitatively determine concentrations of both total element and geochemical fractionation, within the two dust particulate fraction sizes <75 microm and 75-125 microm. Acid digestion using Aqua Regia (3:1 conc. HCl:HNO(3)) was employed for the total elemental analysis, a method that was validated through the use of certified reference materials (CRM). Fractionation studies involved a three-step sequential extraction method performed on five selected samples (representatives of high, mid and low total elemental concentrations). The resultant solutions were analysed for lead and zinc levels to ascertain fractionation throughout the different geochemical fractions, thus assessing bioavailability.It was found that congestion/stop-start traffic patterns did influence and have led to increased levels of heavy metal deposition along inner city roads compared to levels observed on the new relief ring road. Dust particulate fraction sizes were only found to show statistically significant differences in cadmium and manganese, at the probability P < 0.001 or 99.9% confidence limit. Both Cd and Mn showed higher total levels in the smaller fraction sizes (<75 microm), implying that their major release source is exhaust emissions. There were no significant differences in the other elements, at the P > 0.05 or 95% confidence limit. Road type was seen to have little affect on cadmium and manganese, though lead, copper and zinc were all found to show higher levels on the inner city routes. This can be related back to the wear-and-tear of vehicle components as a result of the stop-start traffic patterns (brake pads etc). Both Pb and Zn have shown to be in chemical forms that are bio available to ecosystems.  相似文献   

18.
The Metropolitan Region of Santiago has been declared as nonattainment area for carbon monoxide (CO). The data was based on seven air monitoring stations that do not necessarily represent the real population exposure. Usually, a series of coefficients that relates the concentration of pollutants with health effects (betas of the concentration–response equations) are used. For the calculation of these betas, normally, a city average air pollution concentration is used; nevertheless, these betas do not necessarily represent the real risk of exposure that the inhabitants are experimented. For this reason, this study estimates two aspects that are unknown and that are necessary to policymakers in public health decisions. First, estimate the exposure at a lower spatial resolution level and, second, estimate a concentration–response curve that differs spatially and depends on the proportion of susceptible groups. We followed the Air Pollution and Health, European Approach/Spanish Multicenter Study on the Relationship Between Air Pollution and the Mortality methodology for the determination of the short-term health effect due to CO population exposure at the three spatial levels (city, zone, and county). We found that there are different risks in cardiorespiratory mortality in the group over 64 years old associated to an unequal exposure to CO in Santiago city. The higher risks are in counties located to the south–east of the city. These finding confirm the necessity to face, in a different way, the approach when evaluating control strategies and policy decision to control air pollution in Santiago.  相似文献   

19.
The aim of this study was risk characterization of a replaced urban industrial land located north of Qingdao, in relation to heavy metals values. Soil concentrations of Cd, Pb, Cu, Ni, Cr, and Zn were analyzed. It was observed that the components of Cd, Pb, Cu, Ni, Cr, and Zn are about 2.22, 8.07, 4.70, 6.81, 2.65, and 3.0-folds, respectively, when compared with the local natural background values in Qingdao. The spatial distribution of heavy metals indicated that these hotspots for Cr and Zn located in the southwestern part, Ni and Cd in the middle of the south area, Pb in the northwest, and Cu in the middle of the east area. The values of pollution index and Nemerow integrated pollution index revealed that 100 % of soil samples were moderately or heavily contaminated by six heavy metals. From these results, human health risk assessment for sensitive population was performed according to two different land uses. For non-carcinogenic risk, the direct oral ingestion appeared to be the main exposure pathway followed by dermal and inhalation absorption. The HI values of Pb and Cr characterized for children were larger than 1, while HI values of each metal for adults in two scenarios were lower than 1. Besides, carcinogenic risk from inhalation exposure to Cr for children and adults in two scenarios all exceeded the safety limit.  相似文献   

20.
The concentrations of HCB, PCB, and PAH in epiphytic mosses (Hylocomium splendens and Pleurozium schreberi) and forest humus were used to study the atmospheric exposure of conferous forests in a region in central Sweden. Air concentrations of HCB and PCB were monitored around an expected source. Moss contamination was used as a short-term exposure indicator, and humus contamination was assumed to indicate long-term exposure to HCB, PCB, and PAH.The level of HCB in mosses (0.4–1.7 ng/g, by dry weight, DW) complied well with background values. The levels of PCB measured as a sum of 7 identified PCB-congeners varied between 2–28 ng/g DW, with the highest levels in moss from the western part of the region, and decreasing concentrations from west to east. Around an expected PCB source in the southeastern part of the region the concentrations of PCB declined with increasing distance from the source area. The identified PAH concentrations in mosses varied between 39 and 730 ng/g DW. The PAH content in the mosses consisted mainly of nonvolatile PAH while the more volatile PAH were below the detection limit. The levels of HCB in humus were slightly more than in mosses (0.4–3.3 ng/g DW), and complied well with the background values. Sum PCB in the humus varied between 2 and 28 ng/g DW. The PAH in the humus were mainly nonvolatile PAH. The PAH concentrations in humus varied between 99 and 2600 ng/g DW. The air concentrations of PCB around the expected source (radius <1.5 km) were higher than background levels, and most likely caused the raised levels of PCB measured in the moss nearby.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号