1.
This study was conducted to examine the feasibility of using a moving-bed-biofilm reactor with internal circulation through aeration for the treatment of municipal wastewater. The attached film was a mixed-microorganism consortium, which used composite-refined-diatomaceous earth as novel biomass carriers to form a diatomaceous-earth-moving-bed-biofilm-reactor (DEMBBR) process. The startup of laboratory-scale, continuous-flow reactor was successfully achieved without seeding activated sludge. The DEMBBR process removed chemical oxygen demand, total phosphorus, ammonium-nitrogen, and turbidity at the highest rate of 88.5, 83, 92.3, and 96.7%, respectively, with a hydraulic retention time of only 2.5 hours. The DEMBBR was less affected by interruption and adverse operation conditions than the conventional-activated-sludge reactor. Thus, the DEMBBR could be proposed to be a cost-effective, small-wastewater-treatment-process unit.  相似文献   

2.
The treatment of a cyanidation effluent containing thiocyanate, free cyanide, and complexed cyanide was continuously performed for a period of 6 months. Activated carbon, pozzolana, and a mixture of pumice stone and zeolite were tested as supports in fixed bed reactors. Activated carbon adsorbed the different forms of cyanide. In contrast, the other supports did not remove any pollutants from the effluent during an adsorption experiment. All supports successfully allowed fixation of bacteria. More than 90% of the thiocyanate was biologically decomposed into NH4+, CO2 and SO4(2-), even when increasing the feed flow-rate and the pollutant concentrations. Free and complexed cyanides were eliminated, probably through a combination of precipitation and biological degradation. The oxidation of ammonium into nitrate was only performed by the activated carbon-containing column and with the more diluted feeding. The nitrification process was inhibited in all reactors when the cyanide concentrations and feed flow-rates were increased.  相似文献   

3.
Three different combinations of treatment techniques, i.e. electrocoagulation combined with microfiltration (EMR), membrane bioreactor (MBR) and electrocoagulation integrated with membrane bioreactor (hybrid MBR, (HMBR)), were analysed and compared for the treatment of tannery wastewater operated for 7 days under the constant trans-membrane pressure of 5 kPa. HMBR was found to be most suitable in performance as well as fouling reduction, with 94 % of chemical oxygen demand (COD) removal, 100 % chromium removal and 8 % improvement in percentage reduction in permeate flux compared to MBR with only 90 % COD removal and 67 % chromium removal. The effect of mixed liquor suspended solids on fouling was also investigated and was found to be insignificant. EMR was capable of elevating the flux but was not as efficient as HMBR and MBR in COD removal. Fouling reduction by HMBR was further confirmed by SEM-EDX and particle size analysis.  相似文献   

4.
Two two-stage sequencing batch reactors (TSSBR), one attached-growth and one suspended-growth, were operated under three levels of wastewater concentration (approximately 4,000, 2,000 and 500 TOC mg/L), respectively, to compare the pH and ORP (oxidation-reduction potential) patterns and system performance. In both TSSBR systems, the pH and ORP profiles varied with organic loading yet exhibited consistent patterns with distinctive features suitable for real-time control. For all runs at the three levels of influent, both systems achieved similar levels of treatment for BOD5, TOC and TSS of over 97.5, 93.4, and 97.3%, respectively. The attached-growth system out performed the suspended-growth system in achieving the same levels of treatment at much shorter aeration cycle times. The treatment efficiency for NO3(-)-N and PO4(-3) was greatly affected by the carbon content in the wastewater, and the best treatment was achieved during the TOC approximately 4,000 mg/L runs with final effluent at 4.0 and 21.3 mg/L, respectively.  相似文献   

5.
ABR-好氧颗粒污泥处理黄连素废水的启动研究   总被引:1,自引:0,他引:1  
实验研究了ABR-好氧颗粒污泥组合工艺处理黄连素制药废水的启动运行,通过分析发现,ABR装置在HRT为4 d,黄连素浓度为50 mg/L的运行方式下成功启动,反应器运行稳定后每个格室MLSS平均值分别为25 840、21 560、27 500和11 200 mg/L。以ABR出水为营养物,成功培养出粒径在2~10 mm,沉降速率为104~137 m/h,沉降性能优良的好氧颗粒污泥。该组合工艺在启动实验的末期,进水COD浓度为3 000~4 000 mg/L左右,出水COD浓度到达168.4~271mg/L,系统总的去除率保持在90%~95%之间,表明ABR-好氧颗粒污泥组合工艺能够有效地处理黄连素制药废水。  相似文献   

6.
In this study, a cascade of anoxic and oxic fluidized bed biofilm reactors system was carried out to treat synthetic municipal wastewater. The parameters of the influent flow rates and C/N ratios were discussed. System performance was acceptable for chemical oxygen demand (COD), ammonia, and total nitrogen removal. A decrease of ammonia and total nitrogen removal efficiencies, however, was observed when the influent flow rates increased to 5.04 and 6.12 1 h(-1). Total nitrogen removal decreased at the influent C/N ratio of 3:1. The measured ratios of COD reduction in the anoxic column to nitrogen removal through nitrification-denitrification were 3.7, 3.5, 3.3, and 3.1 g COD/g(-1) N on average when the influent C/N ratios changed from 6:1 to 3:1. The observed sludge yield (Yobs) was 0.169 g VSS g COD(-1) because of perfect denitrification in the anoxic column and the relatively long solids retention time.  相似文献   

7.
为了提高一级稳定表流湿地(stable surface flow wetland,SSFW)的出水水质,在单级稳定表流湿地后串联一级潜流人工湿地,构成两级混合稳定表流湿地(two steps hybrid stable surface flow wetland,TSHSSFW),研究气候变化对其净化效果的影响,并同一级潜流人工湿地(one step subsurface flow wetland,OSSFW)进行对比。研究表明,气候变化对TSHSSFW的COD和总磷去除率影响较小,去除率均在80%左右;而对氨氮和总氮的去除率影响比较大,夏季TSHSSFW的氨氮和总氮去除率分别为87.77%和77.74%,而冬季氨氮和总氮的去除率分别为54.07%和48.84%。相比单级潜流人工湿地(OSSFW),有SSFW作为前处理的潜流人工湿地对氨氮和总氮的去除率较高。  相似文献   

8.
Oily wastewater treatment using a novel hybrid PBR-UASB system   总被引:3,自引:0,他引:3  
Jeganathan J  Nakhla G  Bassi A 《Chemosphere》2007,67(8):1492-1501
In this study, anaerobic treatability of oily wastewater was investigated in a hybrid reactor system consisting of a packed bed reactor (PBR) followed by an upflow anaerobic sludge blanket (UASB) reactor at 35 degrees C. The system was operated using real pet food wastewater at different hydraulic retention times and loading rates for 165 d. The PBR was packed with sol-gel/alginate beads containing immobilized enzyme which hydrolyzed the oil and grease (O&G) into free long chain fatty acids, that were biodegraded by the UASB. The hybrid system was operated up to an oil loading rate of 4.9 kg O&Gm(-3)d(-1) (to the PBR) without any operational problems for a period of 100 d, with COD and O&G removal efficiencies above 90% and no sludge flotation was observed in the UASB. Beads supplement to the PBR was less than 2 g d(-1) and the relative activity was about 70%. Further increment in O&G loading to 18.7 kg O&Gm(-3)d(-1) caused destabilization of the system with 0.35% (v float/v feed) sludge float removed from the UASB.  相似文献   

9.
This study compared the swine wastewater treatment of two identical lab-scale two-stage sequencing batch reactors (TSSBR) under similar conditions except that one was operated on a fixed-time mode and the other on a real-time mode. While both TSSBR systems performed very well, the real-time TSSBR performed far better then the fixed-time TSSBR, in every aspect of carbon, nitrogen, and phosphorous removal. The removals of COD, TOC, were at 97% and for BOD5 even at 99.7%. In terms of NH4-N and TKN removals, the real-time TSSBR achieved removal of over 98%. For phosphorus removals (Ortho-P and total P) the results from the real-time TSSBR was quite remarkable at 97.7%.  相似文献   

10.
中小型点源污染的控制是提高水环境质量和解决水资源短缺的关键。一体式悬浮载体生物流化床(ISCBFB)占地面积小、处理效率高,适合中小型点源污水的处理。以公牛啤酒厂废水为试验原水进行了研究,试验期间进水COD平均浓度1 213.38 mg/L,出水平均为50.75 mg/L,平均去除率达到95.82%。进水氨氮平均浓度为22.50 mg/L,出水平均为4.31 mg/L,平均去除率达到80.99%,试验中全部出水水样COD及氨氮浓度均达到国家《污水综合排放标准》(GB 8978-1988)一级标准。总之,一体式悬浮载体生物流化床对啤酒废水具有很好的去除效果。  相似文献   

11.
生物强化技术提高SBR系统对低温苯胺废水处理能力的研究   总被引:1,自引:2,他引:1  
为了考察高效菌株生物强化效能,解决低温条件下含苯胺废水处理效果差的问题.选择实验室筛选的高效低温苯胺降解菌JH-9为研究对象,考察了其苯胺降解能力和絮凝特性,并采用生物强化的方法将其投加到SBR反应系统中,考察其对提高系统低温条件下(12℃)含苯胺废水的处理能力的改善.结果表明:JH-9细菌在初始苯胺浓度为250 ms/L的培养液中培养52 h,去除率可达100%,其对石化废水中的其他污染物也有一定的降解能力,并且具有产絮能力.将其应用于SBR的强化系统对提高系统低温条件下(12℃)对苯胺去除效果很有效,针对含有苯胺174 mg/L的石化废水,强化系统对苯胺的去除率达到97.8%.除此以外该菌对系统TOC的去除、污泥的MLSS、MLVSS、SV等指标均有一定改善,利于保证系统快速启动和稳定运行.  相似文献   

12.
Wastewater samples from an anaerobic reactor were extracted with hexane and derivatized with diazomethane (method 1) and with acetic anidride (method 2). Gas chromatography with electron-capture detection (ECD) was employed for separating the parent compound and intermediates trichlorophenols (TCP) and dichlorophenols (DCP) which originated from the penta chlorophenol (PCP) degradation process. The relations between concentrations of PCP, TCP and DCP areas were linear in the range of concentrations of 0.2 to 8 mg/L and 0.025 mg/L to 5 mg/L for methods 1 and 2, respectively. The repeatability of the extraction methods was satisfactory, with variation coefficients lower than 11%. For method 1, at the fortification level of 0.2 mg/L, recovery of PCP, TCP, and DCP was 112%, 74% and 45%, respectively. For method 2, the corresponding recovery values at the fortification level of 0.1 mg/L were 91%, 93% and 103%, respectively. Storage of the frozen samples did not alter their PCP determination properties. The chromatographic methods adapted for chlorophenol determination in wastewater were suitable with relatively simple manipulation techniques. The obtained results were reproducible and allowed identification of intermediates formed during the PCP degradation process.  相似文献   

13.
Wastewater samples from an anaerobic reactor were extracted with hexane and derivatized with diazomethane (method 1) and with acetic anidride (method 2). Gas chromatography with electron-capture detection (ECD) was employed for separating the parent compound and intermediates trichlorophenols (TCP) and dichlorophenols (DCP) which originated from the penta chlorophenol (PCP) degradation process. The relations between concentrations of PCP, TCP and DCP areas were linear in the range of concentrations of 0.2 to 8 mg/L and 0.025 mg/L to 5 mg/L for methods 1 and 2, respectively. The repeatability of the extraction methods was satisfactory, with variation coefficients lower than 11%. For method 1, at the fortification level of 0.2 mg/L, recovery of PCP, TCP, and DCP was 112%, 74% and 45%, respectively. For method 2, the corresponding recovery values at the fortification level of 0.1 mg/L were 91%, 93% and 103%, respectively. Storage of the frozen samples did not alter their PCP determination properties. The chromatographic methods adapted for chlorophenol determination in wastewater were suitable with relatively simple manipulation techniques. The obtained results were reproducible and allowed identification of intermediates formed during the PCP degradation process.  相似文献   

14.
Environmental Science and Pollution Research - Treatment of textile wastewater using ultrafiltration membranes was carried out in this study. Since membrane fouling is a major operational problem...  相似文献   

15.
在普通活性污泥系统的曝气池中投加一定量的填料构成复合生物反应器 ,可以增加曝气池中的生物体量至 6g/L左右 ,在HRT为 8h ,泥龄为 5d时 ,CODCr、氨氮的去除率分别提高了 2 0 %和9.6% ,容积负荷对复合生物反应器的脱氮能力影响较小。该工艺对污泥膨胀有较好的控制  相似文献   

16.
构建了双室混合生物阴极微生物燃料电池(microbial fuel cell,MFC)处理高盐榨菜废水,探讨了不同电流强度对混合膜 MFC 脱氮的影响,并分析了产电特性及微生物群落特征。结果表明,高电流通量可缩短双室混合膜MFC的完全脱氮周期,且主要缩短的是稳定期周期。相对于其他3个实验组,电流强度最大的S3实验组硝酸盐平均去除速率((5.72±0.10) mg·(L·d)−1)与硝酸盐最高去除速率((8.45±0.15) mg·(L·d)−1)均最大,且实现总氮100%去除的时间最短(19 d),稳定期硝酸盐去除速率k (6.122 5 mg·(L·d)−1)最大,这说明增大电流强度可促进混合膜MFC 电营养反硝化。电营养反硝化菌可直接利用电子进行反硝化反应,而较大的电子通量给阴极电活性自养脱氮微生物提供了丰富的生命燃料。在产电方面,曝气阶段开路电压(S1、S2、S3、S4分别为750、729、721、699 mV)随外加电阻的增大而增大,最大功率密度相差却并不显著(1.09、0.94、1.04、1.02 W·m−3);停止曝气阶段,阴极室电子受体的减少,导致MFC产电性能普遍下降,外电阻最大的S1实验组开路电压(746 mV)与最大功率密度(0.77 W·m−3)为最高。高通量测序结果表明,承担电营养反硝化功能的菌群可能为norank_f_Hydrogenophaga,Azoarcus。以上研究结果可为后续双室混合膜 MFC处理高盐废水提供技术参考。  相似文献   

17.
An aerobic bioreactor and an anaerobic bioreactor, each coupled with a microfiltration membrane filter (MBR), were operated at different hydraulic retention times (HRTs) with primary effluent from the City of Elmhurst, Illinois, municipal-wastewater-treatment plant. The soluble chemical oxygen demand (COD) removal performance of the anaerobic MBR system was similar to that of the aerobic MBR under the same operational conditions, without the added cost of aeration. The results indicated that the solids deposition rate on the membrane surface was lower in the case of anaerobic MBR compared to the aerobic MBR, indicating possible lower loss in water-flux rates. This research found that an anaerobic MBR is a feasible and economical option for municipal-wastewater-treatment plants seeking COD removal by a biological process followed by a separate nitrification and denitrification system.  相似文献   

18.
19.
20.
复合生物反应器处理焦化废水试验研究   总被引:6,自引:0,他引:6  
采用在悬浮相污泥中投入纤维球填料形成单一复合生物反应器来处理焦化废水,研究了各个运行参数对复合生物反应器处理效果的影响,确定出最佳的运行参数,并研究了在最佳运行条件下复合生物反应器对焦化废水中的COD和NH3-N的去除情况。试验结果表明,采用单一复合生物反应器是一种很好的焦化废水处理方法,它能有效地降解焦化废水中的COD和NH3-N等难降解物质,当进水COD和NH3-N分别小于670、260mg/L时,COD和NH3-N的去除率分别可高达94.8%和91.4%。  相似文献   