首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A series of flow-cell experiments was conducted to investigate aqueous dissolution and mass-removal behavior for systems wherein immiscible liquid was non-uniformly distributed in physically heterogeneous source zones. The study focused specifically on characterizing the relationship between mass flux reduction and mass removal for systems for which immiscible liquid is poorly accessible to flowing water. Two idealized scenarios were examined, one wherein immiscible liquid at residual saturation exists within a lower-permeability unit residing in a higher-permeability matrix, and one wherein immiscible liquid at higher saturation (a pool) exists within a higher-permeability unit adjacent to a lower-permeability unit. The results showed that significant reductions in mass flux occurred at relatively moderate mass-removal fractions for all systems. Conversely, minimal mass flux reduction occurred until a relatively large fraction of mass (>80%) was removed for the control experiment, which was designed to exhibit ideal mass removal. In general, mass flux reduction was observed to follow an approximately one-to-one relationship with mass removal. Two methods for estimating mass-flux-reduction/mass-removal behavior, one based on system-indicator parameters (ganglia-to-pool ratio) and the other a simple mass-removal function, were used to evaluate the measured data. The results of this study illustrate the impact of poorly accessible immiscible liquid on mass-removal and mass-flux processes, and the difficulties posed for estimating mass-flux-reduction/mass-removal behavior.  相似文献   

2.
The magnitude of contaminant mass-flux reduction associated with a specific amount of contaminant mass removed is a key consideration for evaluating the effectiveness of a source-zone remediation effort. Thus, there is great interest in characterizing, estimating, and predicting relationships between mass-flux reduction and mass removal. Published data collected for several field studies were examined to evaluate relationships between mass-flux reduction and source-zone mass removal. The studies analyzed herein represent a variety of source-zone architectures, immiscible-liquid compositions, and implemented remediation technologies. There are two general approaches to characterizing the mass-flux-reduction/mass-removal relationship, end-point analysis and time-continuous analysis. End-point analysis, based on comparing masses and mass fluxes measured before and after a source-zone remediation effort, was conducted for 21 remediation projects. Mass removals were greater than 60% for all but three of the studies. Mass-flux reductions ranging from slightly less than to slightly greater than one-to-one were observed for the majority of the sites. However, these single-snapshot characterizations are limited in that the antecedent behavior is indeterminate. Time-continuous analysis, based on continuous monitoring of mass removal and mass flux, was performed for two sites, both for which data were obtained under water-flushing conditions. The reductions in mass flux were significantly different for the two sites (90% vs. approximately 8%) for similar mass removals ( approximately 40%). These results illustrate the dependence of the mass-flux-reduction/mass-removal relationship on source-zone architecture and associated mass-transfer processes. Minimal mass-flux reduction was observed for a system wherein mass removal was relatively efficient (ideal mass-transfer and displacement). Conversely, a significant degree of mass-flux reduction was observed for a site wherein mass removal was inefficient (non-ideal mass-transfer and displacement). The mass-flux-reduction/mass-removal relationship for the latter site exhibited a multi-step behavior, which cannot be predicted using some of the available simple estimation functions.  相似文献   

3.
We investigated, using model simulations, the changes occurring in the distribution of dense non-aqueous phase liquid (DNAPL) mass (Sn) within the source zone during depletion through dissolution, and the resulting changes in the contaminant flux distribution (J) at the source control plane (CP). Two numerical codes (ISCO3D and T2VOC) were used to simulate selected scenarios of DNAPL dissolution and transport in three-dimensional, heterogeneous, spatially correlated, random permeability fields with emplaced sources. Data from the model simulations were interpreted based on population statistics (mean, standard deviation, coefficient of variation) and spatial statistics (centroid, second moments, variograms). The mean and standard deviation of the Sn and J distributions decreased with source mass depletion by dissolution. The decrease in mean and standard deviation was proportional for the J distribution resulting in a constant coefficient of variation (CV), while for the Sn distribution, the mean decreased faster than the standard deviation. The spatial distributions exhibited similar behavior as the population distribution, i.e., the CP flux distribution was more stable (defined by temporally constant second moments and range of variograms) than the Sn distribution. These observations appeared to be independent of the heterogeneity of the permeability (k) field (variance of the log permeability field=1 and 2.45), correlation structure (positive vs. negative correlation between the k and Sn domains) and the DNAPL dissolution model (equilibrium vs. rate-limited), for the cases studied. Analysis of data from a flux monitoring field study (Hill Air Force Base, Utah) at a DNAPL source CP before and after source remediation also revealed temporal invariance of the contaminant flux distribution. These modeling and field observations suggest that the temporal evolution of the contaminant flux distribution can be estimated if the initial distribution is known. However, the findings are preliminary and broader implications to sampling strategies for remediation performance assessment need to be evaluated in additional modeling and experimental studies.  相似文献   

4.
The effectiveness of removal of nonaqueous phase liquids (NAPLs) from the entrapment source zone of the subsurface has been limited by soil heterogeneity and the inability to locate all entrapped sources. The goal of this study was to demonstrate the uncertainty of degree of source removal associated with aquifer heterogeneity. In this demonstration, source zone NAPL removal using surfactant-enhanced dissolution was considered. Model components that simulate the processes of natural dissolution in aqueous phase and surfactant-enhanced dissolution were incorporated into an existing code of contaminant transport. The dissolution modules of the simulator used previously developed Gilland-Sherwood type phenomenological models of NAPL dissolution to estimate mass transfer coefficients that are upscaleable to multidimensional flow conditions found at field sites. The model was used to simulate the mass removal from 10 NAPL entrapment zone configurations based on previously conducted two-dimensional tank experiments. These entrapment zones represent the NAPL distribution in spatially correlated random fields of aquifer hydraulic conductivity. The numerical simulations representing two-dimensional conditions show that effectiveness of mass removal depends on the aquifer heterogeneity that controls the NAPL entrapment and delivery of the surfactant to the locations of entrapped NAPLs. Flow bypassing resulting from heterogeneity and the reduction of relative permeability due to NAPL entrapment reduces the delivery efficiency of the surfactant, thus prolonging the remediation time to achieve desired end-point NAPL saturations and downstream dissolved concentrations. In some extreme cases, the injected surfactant completely bypassed the NAPL source zones. It was also found that mass depletion rates for different NAPL source configurations vary significantly. The study shows that heterogeneity result in uncertainties in the mass removal and achievable end-points that are directly related to dissolved contaminant plume development downstream of the NAPL entrapment zone.  相似文献   

5.
An existing multiphase flow simulator was modified in order to determine the effects of four mechanisms on NAPL mass removal in a strongly layered heterogeneous vadose zone during soil vapor extraction (SVE): a) NAPL flow, b) diffusion and dispersion from low permeability zones, c) slow desorption from sediment grains, and d) rate-limited dissolution of trapped NAPL. The impacts of water and NAPL saturation distribution, NAPL-type (i.e., free, residual, or trapped) distribution, and spatial heterogeneity of the permeability field on these mechanisms were evaluated. Two different initial source zone architectures (one with and one without trapped NAPL) were considered and these architectures were used to evaluate seven different SVE scenarios. For all runs, slow diffusion from low permeability zones that gas flow bypassed was a dominant factor for diminished SVE effectiveness at later times. This effect was more significant at high water saturation due to the decrease of gas-phase relative permeability. Transverse dispersion contributed to fast NAPL mass removal from the low permeability layer in both source zone architectures, but longitudinal dispersion did not affect overall mass removal time. Both slow desorption from sediment grains and rate-limited mass transfer from trapped NAPL only marginally affected removal times. However, mass transfer from trapped NAPL did affect mass removal at later time, as well as the NAPL distribution. NAPL flow from low to high permeability zones contributed to faster mass removal from the low permeability layer, and this effect increased when water infiltration was eliminated. These simulations indicate that if trapped NAPL exists in heterogeneous porous media, mass transfer can be improved by delivering gas directly to zones with trapped NAPL and by lowering the water content, which increases the gas relative permeability and changes trapped NAPL to free NAPL.  相似文献   

6.
The U.S. Environmental Protection Agency (EPA), in cooperation with Accutech Remedial Systems (ARS) and the New Jersey Institute of Technology (NJIT), performed a field demonstration of Pneumatic Fracturing Extraction (PFE)SM for the removal of chlorinated-volatile organic compounds (VOCs) from vadose zones of low permeability. The demonstration was conducted in the fall of 1992 at an industrial park in Somerville, New Jersey, where removal of VOC contamination in shale bedrock was required to comply with New Jersey’s Environmental Cleanup Responsibility Act (ECRA). During the demonstration, airflow and contaminant concentrations were monitored to establish a database against which the developer’s claims about the technology were evaluated. The developer contended that PFE would increase extracted airfkiw rates from the subsurface formation by at least 100 percent and would increase the mass removal rate for the key contaminant, trichloroethene (TCE), by at least 50 percent. Also, during the demonstration hot-gas injection was evaluated. Based on comparisons of four-hour test results before and after fracturing, airflow rates increased more than 600 percent, and TCE mass-removal rates increased about 675 percent. The increase in TCE mass-removal rates appeared to be a result, primarily, of the increased airflow. In addition, the extracted air contained significantly higher concentrations of other VOCs after fracturing. Using data developed in the four-hour postfracture test, the estimated cost for a hypothetical one-year clean-up is $140 per pound of TCE removed, or $140 per ton of soil contaminated with one pound of TCE. Experiments to evaluate the effects of injecting heated air, at 200 to 250°F, into the vadose zone gave inconclusive results.  相似文献   

7.
Changes in contaminant fluxes resulting from aggressive remediation of dense nonaqueous phase liquid (DNAPL) source zone were investigated at two sites, one at Hill Air Force Base (AFB), Utah, and the other at Ft. Lewis Military Reservation, Washington. Passive Flux Meters (PFM) and a variation of the Integral Pumping Test (IPT) were used to measure fluxes in ten wells installed along a transect down-gradient of the trichloroethylene (TCE) source zone, and perpendicular to the mean groundwater flow direction. At both sites, groundwater and contaminant fluxes were measured before and after the source-zone treatment. The measured contaminant fluxes (J; ML(-2)T(-1)) were integrated across the well transect to estimate contaminant mass discharge (M(D); MT(-1)) from the source zone. Estimated M(D) before source treatment, based on both PFM and IPT methods, were approximately 76 g/day for TCE at the Hill AFB site; and approximately 640 g/day for TCE, and approximately 206 g/day for cis-dichloroethylene (DCE) at the Ft. Lewis site. TCE flux measurements made 1 year after source treatment at the Hill AFB site decreased to approximately 5 g/day. On the other hand, increased fluxes of DCE, a degradation byproduct of TCE, in tests subsequent to remediation at the Hill AFB site suggest enhanced microbial degradation after surfactant flooding. At the Ft. Lewis site, TCE mass discharge rates subsequent to remediation decreased to approximately 3 g/day for TCE and approximately 3 g/day for DCE approximately 1.8 years after remediation. At both field sites, PFM and IPT approaches provided comparable results for contaminant mass discharge rates, and show significant reductions (>90%) in TCE mass discharge as a result of DNAPL mass depletion from the source zone.  相似文献   

8.
Complaints by the neighbourhood due to odour pollution from livestock farming are increasing. Therefore, some countries have already developed guidelines to address odour from livestock. These guidelines are in use to assess the necessary separation distance between livestock buildings and residential areas such that odour is not felt as an annoyance. In all these guidelines, the separation distance is calculated as a function of the rate of pollution. These are mainly power functions with an exponent between 0.3 and 0.5. The Austrian regulatory dispersion model, a Gauss model, is used to calculate the frequency distribution of the dilution factor for 12 classes of distances between 50 and 500 m downwind from the source. These data were fitted to an extended Weibull distribution of the dilution factor to determine the exponent of the power function describing the separation distance as a function of the emission. The exponent has a value of about 0.72. This result, achieved with a wind and stability statistics representative for the Austrian flatlands north of the Alps, indicates a stronger dependance of the separation distance from the odour emission than suggested by the guidelines.  相似文献   

9.
The chemical mass balance (CMB) receptor model is commonly used in source apportionment studies as a means for attributing measured airborne particulate matter (PM) to its constituent emission sources. Traditionally, error terms (e.g., measurement and source profile uncertainty) associated with the model have been treated in an additive sense. In this work, however, arguments are made for the assumption of multiplicative errors, and the effects of this assumption are realized in a Bayesian probabilistic formulation which incorporates a ‘modified’ receptor model. One practical, beneficial effect of the multiplicative error assumption is that it automatically precludes the possibility of negative source contributions, without requiring additional constraints on the problem. The present Bayesian treatment further differs from traditional approaches in that the source profiles are inferred alongside the source contributions. Existing knowledge regarding the source profiles is incorporated as prior information to be updated through the Bayesian inferential scheme. Hundreds of parameters are therefore present in the expression for the joint probability of the source contributions and profiles (the posterior probability density function, or PDF), whose domain is explored efficiently using the Hamiltonian Markov chain Monte Carlo method. The overall methodology is evaluated and results compared to the US Environmental Protection Agency's standard CMB model using a test case based on PM data from Fresno, California.  相似文献   

10.
In situ chemical oxidation is a technology that has been applied to speed up remediation of a contaminant source zone by inducing increased mass transfer from DNAPL sources into the aqueous phase for subsequent destruction. The DNAPL source zone can consist of one or more individual sources that may be present as an interconnected pool of high saturation, as a region of disconnected ganglia at residual saturation, or as combinations of these two morphologies. Potassium permanganate (KMnO(4)) is a commonly employed oxidant that has been shown to rapidly destroy DNAPL compounds like PCE and TCE following second-order kinetics in an aqueous system. During the oxidation of a target DNAPL compound, or naturally occurring reduced species in the subsurface, manganese oxide (MnO(2)) solids are produced. Research has shown that these manganese oxide solids may result in permeability reductions in the porous media thus reducing the ability for oxidant to be transported to individual DNAPL sources. It can also occur at the DNAPL-water interface, decreasing contact of the oxidant with the DNAPL. Additionally, MnO(2) formation at the DNAPL-water interface, and/or flow-bypassing as a result of permeability reductions around the source, may alter the mass transfer from the DNAPL into the aqueous phase, potentially diminishing the magnitude of any DNAPL mass depletion rate increase induced by oxidation. An experiment was performed in a two-dimensional (2D) sand-filled tank that included several discrete DNAPL source zones. Spatial and temporal monitoring of aqueous PCE, chloride, and permanganate concentrations was used to relate changes in mass depletion of, and mass flux, from DNAPL residual and pool source zones to chemical oxidation performance and MnO(2) formation. During the experiment, permeability changes were monitored throughout the 2D tank and these were related to MnO(2) deposition as measured through post-oxidation soil coring. Under the conditions of this experiment, MnO(2) formation was found to reduce permeability in and around DNAPL source zones resulting in changes to the overall flow pattern, with the effects depending on source zone configuration. A pool with little or no residual around it, in a relatively homogeneous flow field, appeared to benefit from resulting MnO(2) pore-blocking that substantially reduced mass transfer from the pool even though there was relatively little PCE mass removed from the pool. In contrast, a pool with residual around it (in a more typical heterogeneous flow field) appeared to undergo increased mass transfer as MnO(2) reduced permeability, altering the water flow and increasing the mixing at the DNAPL-water interface. Further, the magnitude of increased PCE mass depletion during oxidation appeared to depend on the PCE source configuration (pool versus ganglia) and decreased as MnO(2) was formed and deposited at the DNAPL-water interface. Overall, the oxidation of PCE mass appeared to be rate-limited by the mass transfer from the DNAPL to aqueous phase.  相似文献   

11.
Analytical solutions, describing the time-dependent DNAPL source-zone mass and contaminant discharge rate, derived previously in Part I [Falta, R.W., Rao, P.S., Basu, N., this issue. Assessing the impacts of partial mass depletion in DNAPL source zones: I. Analytical modeling of source strength functions and plume response. J. Contam. Hydrol.] are used as a flux-boundary condition in a semi-analytical contaminant transport model. These analytical solutions assume a power relationship between the flow-averaged source concentration, and the source DNAPL mass; the empirical exponent (gamma) is a function of the flow field heterogeneity, DNAPL architecture, and the correlation between them. The DNAPL source strength terms can account for partial source remediation, either at time zero, or at some later time after the DNAPL release. The transport model considers advection, retardation, three-dimensional dispersion, and sequential first-order decay/production of several species. A separate solution is used to compute the time-dependent mass of each contaminant in the plume. A series of examples using different values of gamma shows how the benefits of partial DNAPL source remediation can vary with site conditions. In general, when gamma>1, relatively large short-term reductions in the plume concentrations and mass occur, but the source longevity is not strongly affected. Conversely, when gamma<1, the short-term reductions in the plume concentrations and mass are smaller, but the source longevity can be greatly reduced. In either case, the source remediation effort is much more effective if it is undertaken at an early time, before much contaminant mass has entered the plume. If the remediation effort is significantly delayed, the leading parts of the plume are not affected by the source remediation, and additional control or remediation of the plume itself is required.  相似文献   

12.
Magnetic resonance imaging (MRI) was used to visualize the NAPL source zone architecture before and after surfactant-enhanced NAPL dissolution in three-dimensional (3D) heterogeneously packed flowcells characterized by different longitudinal correlation lengths: 2.1 cm (aquifer 1) and 1.1 cm (aquifer 2). Surfactant flowpaths were determined by imaging the breakthrough of a paramagnetic tracer (MnCl(2)) analyzed by the method of moments. In both experimental aquifers, preferential flow occurred in high permeability materials with low NAPL saturations, and NAPL was preferentially removed from the top of the aquifers with low saturation. Alternate flushing with water and two surfactant pulses (5-6 pore volumes each) resulted in approximately 63% of NAPL mass removal from both aquifers. However, overall reduction in mass flux (Mass Flux 1) exiting the flowcell was lower in aquifer 2 (68%) than in aquifer 1 (81%), and local effluent concentrations were found to increase by as high as 120 times at local sampling ports from aquifer 2 after surfactant flushing. 3D MRI images of NAPL revealed that NAPL migrated downward and created additional NAPL source zones in previously uncontaminated areas at the bottom of the aquifers. The additional NAPL source zones were created in the direction transverse to flow in aquifer 2, which explains the higher mass flux relative to aquifer 1. Analysis using a total trapping number indicates that mobilization of NAPL trapped in the two coarsest sand fractions is possible when saturation is below 0.5 and 0.4, respectively. Results from this study highlight the potential impacts of porous media heterogeneity and NAPL source zone architecture on advanced in-situ flushing technologies.  相似文献   

13.
Fracturing, either pneumatic or hydraulic, is a method to improve the performance of soil vapor extraction (SVE) in relatively low permeability soils (< 10(-5) cm/s). A two-dimensional model is presented to simulate trichloroethylene (TCE) soil vapor extraction modified by fracturing. Flow and transport is modeled using mobile macropore and micropore networks, which also have been identified in the literature as dual porosity, dual permeability, or heterogeneous flow models. In this model, fluids can flow in both the macropore and micropore networks. This represents a more general model compared to immobile micropore, mobile macropore models presented thus far in the literature for vapor flow and transport in two dimensions. The model considers pressure- and concentration-driven exchange between the macropore and micropore networks, concentration-driven exchange between the gas and sorbed phases within each network, and equilibrium exchange between the gas and water and a sorbed phase within each network. The parameters employed in an example simulation are based on field measurements made at a fractured site. Considered in the simulations were the influence of the volume percentage of fractures, the length of fractures, the relative location of the water table, and the influence of pulsed pumping. For these simulations, internetwork concentration-driven exchange most significantly affected mass removal. The volume percentage of fractures more significantly influence flow and mass removal than the length of fractures. The depth of the water table below the contamination plume only significantly influenced flow and mass removal when the water table was within 60 cm of the bottom of the contaminated soil in the vadose zone for the parameters considered in this study. Pulsed pumping was not found to increase the amount of mass removed in this study.  相似文献   

14.
Analytical solutions are developed for approximating the time-dependent contaminant discharge from DNAPL source zones undergoing dissolution and other decay processes. The source functions assume a power relationship between source mass and chemical discharge and can consider partial DNAPL source remediation (depletion) at any time after the initial DNAPL release. The source functions are used as a time-dependent boundary condition in an idealized chemical transport model to develop leading order approximations of the plume response to DNAPL source removal. The results suggest that partial DNAPL remediation does not tend to have a dramatic impact on the maximum extent of the plume if very low concentration values are used to define the plume boundaries. However, the solutions show that partial DNAPL removal from the source zone is likely to lead to large reductions in plume concentrations and mass, and it reduces the longevity of the plume. When the mass discharge from the source zone is linearly related to the DNAPL mass, it is shown that partial DNAPL depletion leads to linearly proportional reductions in the plume mass and concentrations.  相似文献   

15.
Three-dimensional, coupled variably saturated flow and biogeochemical reactive transport modeling of a 2008 in situ uranium bioremediation field experiment is used to better understand the interplay of transport and biogeochemical reactions controlling uranium behavior under pulsed acetate amendment, seasonal water table variation, spatially variable physical (hydraulic conductivity, porosity) and geochemical (reactive surface area) material properties. While the simulation of the 2008 Big Rusty acetate biostimulation field experiment in Rifle, Colorado was generally consistent with behaviors identified in previous field experiments at the Rifle IFRC site, the additional process and property detail provided several new insights. A principal conclusion from this work is that uranium bioreduction is most effective when acetate, in excess of the sulfate-reducing bacteria demand, is available to the metal-reducing bacteria. The inclusion of an initially small population of slow growing sulfate-reducing bacteria identified in proteomic analyses led to an additional source of Fe(II) from the dissolution of Fe(III) minerals promoted by biogenic sulfide. The falling water table during the experiment significantly reduced the saturated thickness of the aquifer and resulted in reactants and products, as well as unmitigated uranium, in the newly unsaturated vadose zone. High permeability sandy gravel structures resulted in locally high flow rates in the vicinity of injection wells that increased acetate dilution. In downgradient locations, these structures created preferential flow paths for acetate delivery that enhanced local zones of TEAP reactivity and subsidiary reactions. Conversely, smaller transport rates associated with the lower permeability lithofacies (e.g., fine) and vadose zone were shown to limit acetate access and reaction. Once accessed by acetate, however, these same zones limited subsequent acetate dilution and provided longer residence times that resulted in higher concentrations of TEAP reaction products when terminal electron donors and acceptors were not limiting. Finally, facies-based porosity and reactive surface area variations were shown to affect aqueous uranium concentration distributions with localized effects of the fine lithofacies having the largest impact on U(VI) surface complexation. The ability to model the comprehensive biogeochemical reaction network, and spatially and temporally variable processes, properties, and conditions controlling uranium behavior during engineered bioremediation in the naturally complex Rifle IFRC subsurface system required a subsurface simulator that could use the large memory and computational performance of a massively parallel computer. In this case, the eSTOMP simulator, operating on 128 processor cores for 12h, was used to simulate the 110-day field experiment and 50 days of post-biostimulation behavior.  相似文献   

16.
Urban air pollutant concentration data often tend to fit a two-parameter averaging-time model having three characteristics: (1) pollutant concentrations are (two-parameter) lognormally distributed for all averaging times; (2) median concentrations are proportional to averaging time raised to an exponent; and (3) maximum concentrations are approximately inversely proportional to averaging time raised to an exponent. Concentration data obtained near many isolated point sources and in some urban areas often do not fit a two-parameter lognormal distribution. An increment (either positive or negative) can be added to each such concentration in order to fit the data instead to a three-parameter lognormal distribution. This increment has been incorporated as the third parameter in a new three-parameter averaging-time model that can be used in both point-source and urban settings. Examples show how this new model can be used to analyze SO2 concentration data obtained near a point source to determine the degree of emission reduction needed to achieve the national ambient air quality standards.  相似文献   

17.
Infiltration of PCE in a system containing spatial wettability variations   总被引:2,自引:0,他引:2  
A two-dimensional infiltration experiment was conducted to investigate and quantify the effect of spatial wettability variations on DNAPL migration and entrapment in saturated sands. Experimental observations of tetrachloroethylene (PCE) infiltration showed that organic-wet sand lenses acted as very effective capillary barriers, retaining PCE and inhibiting its downward migration. A multiphase numerical simulator was used to model this sand box experiment. The simulator incorporates wettability-modified van Genuchten and Brooks-Corey capillary pressure/saturation relationships as well as Burdine and Mualem relative permeability relationships. PCE mass distributions, estimated by image analysis of digital photographs taken during the infiltration event, were compared to simulation results. Although both relative permeability models were qualitatively able to predict the PCE retention in the organic-wet layers, simulations with the Mualem model failed to capture the observed rate of PCE migration. A traditional multiphase simulator, incorporating water-wet capillary retention relations, failed to predict both PCE pathways and retention behavior. This study illustrates the potential influence of subsurface wettability variations on DNAPL migration and entrapment and supports the use of modified capillary relations in conjunction with the Burdine model in multiphase flow simulators.  相似文献   

18.
Understanding the process of mass transfer from source zones of aquifers contaminated with organic chemicals in the form of dense non-aqueous phase liquids (DNAPL) is of importance in site management and remediation. A series of intermediate-scale tank experiments was conducted to examine the influence of aquifer heterogeneity on DNAPL mass transfer contributing to dissolved mass emission from source zone into groundwater under natural flow before and after remediation. A Tetrachloroethylene (PCE) spill was performed into six source zone models of increasing heterogeneity, and both the spatial distribution of the dissolution behavior and the net effluent mass flux were examined. Experimentally created initial PCE entrapment architecture resulting from the PCE migration was largely influenced by the coarser sand lenses and the PCE occupied between 30 and 60% of the model aquifer depth. The presence of DNAPL had no apparent effect on the bulk hydraulic conductivity of the porous media. Up to 71% of PCE mass in each of the tested source zone was removed during a series of surfactant flushes, with associated induced PCE mobilization responsible for increasing vertical DNAPL distributions. Effluent mass flux due to water dissolution was also found to increase progressively due to the increase in NAPL-water contact area even though the PCE mass was reduced. Doubling of local groundwater flow velocities showed negligible rate-limited effects at the scale of these experiments. Thus, mass transfer behavior was directly controlled by the morphology of DNAPL within each source zone. Effluent mass flux values were normalized by the up-gradient DNAPL distributions. For the suite of aquifer heterogeneities and all remedial stages, normalized flux values fell within a narrow band with mean of 0.39 and showed insensitivity to average source zone saturations.  相似文献   

19.
In many natural and contaminated aquifers, geochemical processes result in the production or consumption of dissolved gases. In cases where methanogenesis or denitrification occurs, the production of gases may result in the formation and growth of gas bubbles below the water table. Near the water table, entrapment of atmospheric gases during water table rise may provide a significant source of O(2) to waters otherwise depleted in O(2). Furthermore, the presence of bubbles will affect the hydraulic conductivity of an aquifer, resulting in changes to the groundwater flow regime. The interactions between physical transport, biogeochemical processes, and gas bubble formation, entrapment and release is complex and requires suitable analysis tools. The objective of the present work is the development of a numerical model capable of quantitatively assessing these processes. The multicomponent reactive transport code MIN3P has been enhanced to simulate bubble growth and contraction due to in-situ gas production or consumption, bubble entrapment due to water table rise and subsequent re-equilibration of the bubble with ambient groundwater, and permeability changes due to trapped gas phase saturation. The resulting formulation allows for the investigation of complex geochemical systems where microbially mediated redox reactions both produce and consume gases as well as affect solution chemistry, alkalinity, and pH. The enhanced model has been used to simulate processes in a petroleum hydrocarbon contaminated aquifer where methanogenesis is an important redox process. The simulations are constrained by data from a crude oil spill site near Bemidji, MN. Our results suggest that permeability reduction in the methanogenic zone due to in-situ formation of gas bubbles, and dissolution of entrapped atmospheric bubbles near the water table, both work to attenuate the dissolved gas plume emanating from the source zone. Furthermore, the simulations demonstrate that under the given conditions more than 50% of all produced CH(4) partitions to the gas phase or is aerobically oxidised near the water table, suggesting that these processes should be accounted for when assessing the rate and extent of methanogenic degradation of hydrocarbons.  相似文献   

20.
The transfer of contaminant mass between the nonaqueous- and aqueous-phases is a process of central importance for the remediation of sites contaminated by dense nonaqueous-phase liquids (DNAPLs). This paper describes a comparison of the results obtained with various alternative DNAPL-aqueous-phase mass transfer models contained in the literature for predicting DNAPL source-zone depletion times in groundwater systems. These dissolution models were largely developed through laboratory column experiments. To gain insight into the implications of various representations of the local-scale kinetic as well as equilibrium DNAPL dissolution processes, aquifer heterogeneity and the complex architecture of a DNAPL source-zone, the aqueous-phase contaminant concentrations and mass fluxes arriving at a down-gradient compliance boundary are analyzed in a conditional stochastic framework. The hydrogeologic setting is a heterogeneous fluvial aquifer in Southwest Germany, referred to as the aquifer analog dataset, that was intensively characterized in three dimensions for hydrogeological parameters that include permeability, effective porosity, grain size, mineralogy and sorption coefficients. By embedding the various dissolution models into the compositional, multiphase flow model, CompFlow, the relative times predicted for complete depletion of a released DNAPL source due to natural dissolution are explored. Issues related to achieving environmental benefits through, for example, partial DNAPL-zone source removal via enhanced remedial technologies are also discussed. In this context, performance metrics in the form of peak aqueous-phase contaminant concentrations and mass fluxes arriving at a down-gradient compliance boundary are compared to each other. This is done for each of the alternative mass transfer models. A significant reduction in the fractional flux at a downstream location from the DNAPL source can be achieved by partial source-zone mass reduction; however, peak concentration levels at the same location remain much higher than the United States Environment Protection Agency (US-EPA) drinking water limits. Although groundwater quality was found to improve more rapidly for the equilibrium dissolution model, it is also shown that dissolution models that promote rapid DNAPL disappearance produce greater prediction uncertainty in the aqueous-phase flux reduction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号