共查询到20条相似文献,搜索用时 15 毫秒
1.
Synthetic endocrine disruptors in the environment and water remediation by advanced oxidation processes 总被引:6,自引:0,他引:6
The present study is an overview of the literature on classes and types of compounds described as "endocrine disruptors" and their treatability in water by advanced oxidation processes, which generate hydroxyl radicals in water. The review is limited to details of the destruction of three classes of endocrine disruptors, namely bisphenols, alkylphenols and phthalates, which are among the most highly suspected endocrine disrupting compounds that interfere with the hormonal system of wildlife. It was found that photocatalysis with titanium dioxide was the most frequently tested advanced oxidation method most likely due its potential to render complete mineralization. There is sufficient research also with direct and indirect photolysis and ozonation, which were less effective for the overall mineralization but more representative of the conditions existing in real water treatment plants. 相似文献
2.
Arslan-Alaton I 《Journal of environmental management》2007,82(2):145-154
The occurrence of significant amounts of biocidal finishing agents in the environment as a consequence of intensive textile finishing activities has become a subject of major public health concern and scientific interest only recently. In the present study, the treatment efficiency of selected, well-known advanced oxidation processes (Fenton, Photo-Fenton, TiO(2)/UV-A, TiO(2)/UV-A/H(2)O(2)) and ozone was compared for the degradation and detoxification of a commercial textile biocide formulation containing a 2,4,4'-trichloro-2'-hydroxydiphenyl ether as the active ingredient. The aqueous biocide solution was prepared to mimic typical effluent originating from the antimicrobial finishing operation (BOD(5,o) < or =5 mg/L; COD(o)=200 mg/L; DOC(o) (dissolved organic carbon)=58 mg/L; AOX(o) (adsorbable organic halogens)=48 mg/L; LC(50,o) (lethal concentration causing 50% death or immobilization in Daphnia magna)=8% v/v). Ozonation experiments were conducted at different ozone doses (500-900 mg/h) and initial pH (7-12) to assess the effect of ozonation on degradation (COD, DOC removal), dearomatization (UV(280) and UV(254) abatement), dechlorination (AOX removal) and detoxification (changes in LC(50)). For the Fenton experiments, the effect of varying ferrous iron catalyst concentrations and UV-A light irradiation (the Photo-Fenton process) was examined. In the heterogenous photocatalytic experiments, Degussa P25-type TiO(2) was used as the catalyst and the effect of reaction pH (3, 7 and 12) and H(2)O(2) addition on the photocatalytic treatment efficiency was examined. Although in the photochemical (i.e. Photo-Fenton, TiO(2)/UV-A and TiO(2)/UV-A/H(2)O(2)) experiments appreciably higher COD and DOC removal efficiencies were obtained, ozonation appeared to be equally effective to achieve dearomatization (UV(280) abatement) at all studied reaction pH. During ozonation of the textile biocide effluent, AOX abatement proceeded significantly faster than dearomatization and was complete after 20 min ozonation (267 mg O(3)). On the other hand, for complete detoxification, ozonation had to be continued for at least 30 min (corresponding to 400mg O(3)). Effective AOX and acute toxicity removal was also obtained after heterogeneous photocatalytic treatment (TiO(2)/UV-A and TiO(2)/UV-A/H(2)O(2)). The Fenton-based treatment experiments and particularly the dark Fenton reaction resulted in relatively poor degradation, dearomatization, AOX and acute toxicity removals. 相似文献
3.
Comparison of Diuron degradation by direct UV photolysis and advanced oxidation processes 总被引:1,自引:0,他引:1
The rates of Diuron elimination by some advanced oxidation processes (AOPs) such as Fe(III)/UV, Ferrioxalate/UV, Fe(III)/H(2)O(2)/UV, Ferrioxalate/UV/H(2)O(2) and Fe(III)/H(2)O(2) have been compared. Experiments have been conducted at pH=2.3+/-0.1 with a batch reactor equipped with a low-pressure mercury lamp emitting mainly at 253.7nm. Data obtained under the following experimental conditions ([H(2)O(2)](0)=10(-3)M, [Diuron](0)=5x10(-5)M and [Fe(III)](0)=10(-3)M) have shown that rates of Diuron oxidation were higher with the systems Fe(III)/H(2)O(2)/UV and Ferrioxalate/UV/H(2)O(2) than with Fe(III)/UV and Fe(III)/H(2)O(2). On the other hand, Fe(III)/UV was found to be very efficient in mineralization of Diuron solution in comparison to direct UV photolysis. The experimental results showed that radical ()OH is the major pathway in the process of Diuron degradation. 相似文献
4.
Evaluation of Fenton and ozone-based advanced oxidation processes as mature landfill leachate pre-treatments 总被引:1,自引:0,他引:1
Fenton treatment (Fe2+/H2O2) and different ozone-based Advanced Oxidation Processes (AOPs) (O3, O3/OH− and O3/H2O2) were evaluated as pre-treatment of a mature landfill leachate, in order to improve the biodegradability of its recalcitrant organic matter for subsequent biological treatment. With a two-fold diluted leachate, at optimised experimental conditions (initial pH 3, H2O2 to Fe2+ molar ratio of 3, Fe2+ dosage of 4 mmol L−1, and reaction time of 40 min) Fenton treatment removed about 46% of chemical oxygen demand (COD) and increased the five-day biochemical oxygen demand (BOD5) to COD ratio (BOD5/COD) from 0.01 to 0.15. The highest removal efficiency and biodegradability was achieved by ozone at higher pH values, solely or combined with H2O2. These results confirm the enhanced production of hydroxyl radical under such conditions. After the application for 60 min of ozone at 5.6 g O3 h−1, initial pH 7, and 400 mg L−1 of hydrogen peroxide, COD removal efficiency was 72% and BOD5/COD increased from 0.01 to 0.24. An estimation of the operating costs of the AOPs processes investigated revealed that Fe2+/H2O2 was the most economical system (8.2 € m−3 g−1 of COD removed) to treat the landfill leachate. This economic study, however, should be treated with caution since it does not consider the initial investment, prices at plant scale, maintenance and labour costs. 相似文献
5.
Removal of Pb(II) from wastewater using wheat bran 总被引:5,自引:0,他引:5
The adsorption of Pb(II) ions from aqueous solutions on wheat bran (WB) has been investigated as a function of initial concentration, adsorbent dose, adsorbent particle size, agitation speed, temperature, contact time and pH of solution. The equilibrium process was described well by the Langmuir isotherm model with maximum sorption capacities of 69.0, 80.7 and 87.0 mgg(-1) of Pb(II) on wheat bran at 20, 40 and 60 degrees C, respectively. Thermodynamic parameters, i.e. DeltaG(0), DeltaH(0) and DeltaS(0) have also been calculated for the system and the sorption process was found to be endothermic. Good correlation coefficients were obtained for the pseudo second-order kinetic model. The metal ion could be stripped by addition of 0.5M HCl, making the adsorbent regeneration and its reutilization possible. 相似文献
6.
《International Journal of Green Energy》2013,10(1):83-91
The present study is targeted on the feasibility of photocatalytic treatment of industrial wastewater containing metal ions. Photoreductive deposition of metal ions using solar energy irradiated TiO2, has been investigated in presence of citric acid as a hole scavenger. Treatment studies have also been performed at pH values 2, 4, 7, 8, and 10 to determine optimum reaction conditions. Results showed that at the pH value of 2, 100% reduction was achieved for Cr(VI) in a minimum time period. A maximum removal of 95.5% was achieved for Ni(II) at the pH value of 10. 相似文献
7.
Sulfate-reducing bacteria (SRB) that could grow on modified Postgate C medium (PC) containing chromium(VI) were isolated from industrial wastewaters and their chromium(VI) reduction capacities were investigated as a function of changes in the initial pH values, chromium, sulfate, NaCl and reactive dye concentrations. The optimum pH value at 50 mg l(-1) initial chromium(VI) concentration was determined to be 8. Chromium(VI) reduction by SRB was investigated at 22.7-98.4 mg l(-1) initial chromium(VI) concentrations. At the end of the experiments, the mixed cultures of SRB were found to reduce within 2-6 days more than 99% of the initial chromium(VI) levels, which ranged from 22.7 to 74.9 mg l(-1). The effects of the initial 0-9.0 g l(-1) concentrations of disodium sulfate and 0-6% (w/v) concentrations of NaCI to chromium reduction showed that the lowest concentrations of sulfate and NaCI were the best for chromium reduction in the PC medium including 50 mg l(-1) chromium(VI). Chromium(VI) reduction in 50 mg l(-1) and 25-100 mg l(-1) Remazol Blue, Reactive Black B or Reactive Red RB containing media were also investigated. In the experiments, 25-30% of the initial dye concentrations and 95% of the chromium(VI) was removed from the medium at the end of 72-h and 24-h incubation periods, respectively. 相似文献
8.
Applicability of a Septic Tank/Engineered Wetland Coupled System in the Treatment and Recycling of Wastewater from a Small Community 总被引:1,自引:0,他引:1
Mbuligwe SE 《Environmental management》2005,35(1):99-108
A septic tank (ST)/engineered wetland coupled system used to treat and recycle wastewater from a small community in Dar es Salaam, Tanzania was monitored to assess its performance. The engineered wetland system (EWS) had two parallel units each with two serial beds packed with different sizes of media and vegetated differently. The larger-sized medium bed was upstream and was planted with Phragmites (reeds) and the smaller-sized medium bed was downstream and was planted with Typha (cattails). The ST/EWS coupled system was able to remove ammonia by an average of 60%, nitrate by 71%, sulfate by 55%, chemical oxygen demand by 91%, and fecal coliform as well as total coliform by almost 100%. The effluent from the ST/EWS coupled system is used for irrigation. Notably, users of the recycled irrigation water do not harbor any negative feelings about it. This study demonstrates that it is possible to treat and recycle domestic wastewater using ST/EWS coupled systems. The study also brings attention to the fact that an ST/EWS coupled system has operation and maintenance (O&M) needs that must be fulfilled for its effectiveness and acceptability. These include removal of unwanted weeds, harvesting of wetland plants when the EWS becomes unappealingly bushy, and routine repair. 相似文献
9.
The word “electrocoagulation” (EC) will be sometimes used with “electroflotation” (EF) and can be considered as the electrocoagulation/flotation (ECF) process. Through the process of electrolysis, coagulating agents such as metal hydroxides are produced. When aluminium electrodes are used, the aluminium dissolves at the anode and hydrogen gas is released at the cathode. The coagulating agent combines with the pollutants to form large size flocs. As the bubbles rise to the top of the tank they adhere to particles suspended in the water and float them to the surface. In fact, a conceptual framework of the overall ECF process is linked to coagulant generation, pollutant aggregation, and pollutant removal by flotation and settling when it has been applied efficiently to various water and wastewater treatment processes. This review paper considers a significant number of common applications of EC and ECF processes which have been published in journal and conference papers. 相似文献
10.
This study aimed to identify the significant factors that give large effects on the efficiency of Cu(II) extraction from aqueous solutions by soybean oil-based organic solvents using fractional factorial design. Six factors (mixing time (t), di-2-ethylhexylphosphoric acid concentration ([D2EHPA]), organic to aqueous phase ratio (O:A), sodium sulfate concentration ([Na(2)SO(4)]), equilibrium pH (pH(eq)) and tributylphosphate concentration ([TBP])) affecting the percentage extraction (%E) of Cu(II) were investigated. A 2(6-1) fractional factorial design was applied and the results were analyzed statistically. The results show that only [D2EHPA], pH(eq) and their second-order interaction ([D2EHPA] × pH(eq)) influenced the %E significantly. Regression models for %E were developed and the adequacy of the reduced model was examined. The results of this study indicate that fractional factorial design is a useful tool for screening a large number of variables and reducing the number of experiments. 相似文献
11.
The potential of cost-effective coconut husk for the removal of toxic metal ions for environmental protection 总被引:2,自引:0,他引:2
Coconut (Cocos nucifera) husk, an agricultural waste, has been thoroughly investigated for the removal of toxic Cd(II), Cr(III) and Hg(II) ions from aqueous media. The parameters like nature and composition of electrolyte, concentration of toxic ions, dosage of coconut husk, and equilibration time between the two phases were optimized for their maximum accumulation onto the solid surface. The effect of common ions on the uptake of metal ions has been monitored under optimal conditions. The variation of retention of each metal ion with temperature was used to compute the thermodynamic quantities DeltaH, DeltaS and DeltaG. The values 18.1+/-0.6 kJmol(-1), 74+/-2 Jmol(-1)K(-1), and -3.8+/-0.04 kJmol(-1) at 298 K; 10.8+/-0.8 kJmol(-1), 48.8+/-2.7 Jmol(-1)K(-1), and -4.6+/-0.3 kJmol(-1) at 298 K; and -37.4+/-2k Jmol(-1), 105+/-7 Jmol(-1)K(-1) and -2.58+/-0.5 kJmol(-1) at 298 K were obtained for Cd(II), Cr(III) and Hg(II) ions, respectively. The sorption data were analysed by applying different sorption isotherms. The sorption capacity and energy were evaluated for each metal ion. The values of the Freundlich constants 1/n and C(m) were 0.92+/-0.04 and 52.6+/-22.2 mmolg(-1); 0.85+/-0.05 and 56.0+/-0.03 mmolg(-1); and 0.88+/-0.03 and 6.84+/-0.45 mmolg(-1) for Cd(II) Cr(III) and Hg(II) ions, respectively. Similarly, the Dubinin-Radushkevich (D-R) constants beta, X(m,) and E were evaluated for the three metal ions. To check the selectivity of the sorbent, sorption of a number of elements was measured under similar conditions. Separation of Zn(II) from Cd(II); Cr(III) from I(I), Zr(IV), Se(IV), and Hg(II) from Se(IV) and Zn(II) can be achieved using this sorbent. This cheap material has potential applications in analytical chemistry, water decontamination, industrial effluent treatment and in pollution abatement. 相似文献
12.
This study aims to prepare a low-cost, environmentally friendly, and alternative, biosorbent to remove chromium Cr (III) and lead Pb (II) from polluted water and to find out the highest removal efficiencies using 2k factorial experiments. The Cr (III) and Pb (II) tolerant fungal strain identified as Penicillium chrysogenum was isolated from ceramic industrial sludge. The impact of process variables on biosorption of Cr (III) and Pb (II) by P. chrysogenum was first evaluated with the Taguchi screening design. Factors and levels were determined to optimize Cr (III) and Pb (II) removal efficiency. According to this, five factors; initial concentration, pH, biosorbent dose, temperature, and inactivation methods were determined for both metals, each factor defined as a fixed factor with two levels. Optimization of the parameters affecting the removal process was determined by the Taguchi method and the signal-to-noise (S/N) ratios are calculated. The maximum removal efficiency (99.92%) was observed at pH 7, biosorbent 1 mg L–1, inactivation with autoclaving, and at 20°C with an initial metal concentration of 50 mg L–1 Cr (III). On the other hand, the maximum removal efficiency (98.99%) was observed at pH 4, biosorbent 5 mg L–1, inactivation with autoclaving, and at 20°C with an initial metal concentration of 50 mg L–1 Pb (II). Furthermore, metal ions removal by P. chrysogenum was also confirmed by scanning electron microscopy (SEM) combined with an energy dispersive X-ray spectrometer (EDS). The presence of functional groups on fungal cells of metal binding was investigated by Fourier transform infrared (FT-IR). 相似文献
13.
两种高浓度酚醛树脂生产废水的树脂吸附处理及其资源化研究 总被引:1,自引:0,他引:1
采用XDA-1树脂吸附和碱液解吸工艺对两种高浓度酚醛树脂生产废水进行处理和回收研究。结果显示,在室温、pH 4~6、流速1~2BV/h条件下,两种废水的酚浓度分别从9500mg/L和24500mg/L降低到1mg/L和5mg/L,CODC r分别从18800mg/L和212000mg/L降低到1450mg/L和97500mg/L。用浓度4%的NaOH溶液在60℃条件下进行解析,解吸效率达99%。从两种废水中分别回收了浓度8%~12%的羟甲基酚和甲基苯酚,既减少了对环境的污染,又回收了资源。 相似文献
14.
Fate of pathogenic microorganisms and indicators in secondary activated sludge wastewater treatment plants 总被引:1,自引:0,他引:1
This study was undertaken to investigate the removal of pathogenic microorganisms and their indicators in a laboratory scale biological treatment system that simulated the secondary treatment process of a wastewater treatment plant (WWTP). Four groups of microorganisms including bacteria, viruses, protozoa and helminths as well as the selected indicators were employed in the investigation. The results demonstrated that approximately 2-3 log10 removal of the microbial indicators was achieved in the treatment process. The log removal of Clostridium perfringens spores was low due to their irreversible adsorption to sludge flocs. The laboratory treatment system demonstrated a similar removal capability for Escherichia coli and the bacterial indicators (total coliforms, enterococci and particles <2.73 microm/L). The MS-2 bacteriophage, measured as a viral indicator, showed a lower removal than poliovirus, which may be considered as a worst case scenario for virus removal. The results of using particle profiling as an indicator for protozoa and helminths appeared to be inaccurate. The removal performance for bacterial and protozoan pathogens and their indicators in a full scale WWTP and the laboratory treatment system was compared. 相似文献
15.
To increase reliability and electrical performance, shallow-trench isolation (STI) (or called field-oxide (FOX)) structures were inserted in the bulk-contact region of 60-V high-voltage p-channel lateral-diffused MOSFET (pLDMOS) devices in this study. As the FOX ratio increased with the addition of FOX segments, the value of the secondary breakdown current (It2) was enhanced. Therefore, the anti-electrostatic discharge ability of a pLDMOS device can be efficiently improved using this novel method. In addition, when the weighting ratio of FOX structures increased, variation values in the trigger voltage (Vt1) and holding voltage (Vh) of the corresponding samples remained within the range of approximately 1–4 V. The Ron value decreased because of more uniform conduction. The experimental data for the FOX structures added to the bulk revealed that the It2 value was improved by approximately 13.98%, Vh values were greater than 60 V (which is favorable for latch-up immunity), and the Ron value was decreased by approximately 12.62% compared with a reference device under test (without FOX segments in the bulk-contact region). 相似文献
16.
二维与三维电解法处理含铜废水的试验研究 总被引:1,自引:0,他引:1
孙颖 《中国环境管理干部学院学报》2011,(5):63-65
以含铜废水为处理对象,考察了二维电解法的电解电压、电解时间、pH值、极间距对铜去除率的影响。在此基础上为提高处理效率,两极间填充活性炭和玻璃珠形成三维电解,确定了三维电解的最佳运行条件是极间距4cm,pH值3~4,电解电压22 V,电解135min,铜离子的去除率为80.6%。 相似文献
17.
Magdalena Svanstrm Morgan Frling Michael Modell William A. Peters Jefferson Tester 《Resources, Conservation and Recycling》2004,41(4):573
Environmental aspects of using supercritical water oxidation (SCWO) to treat sewage sludge were studied using a life cycle assessment (LCA) methodology. The system studied is the first commercial scale SCWO plant for sewage sludge in the world, treating sludge from the municipal wastewater treatment facility in Harlingen, TX, USA. The environmental impacts were evaluated using three specific environmental attributes: global warming potential (GWP), photo-oxidant creation potential (POCP) and resource depletion; as well as two single point indicators: EPS2000 and EcoIndicator99. The LCA results show that for the described process, gas-fired preheating of the sludge is the major contributor to environmental impacts, and emissions from generating electricity for pumping and for oxygen production are also important. Overall, SCWO processing of undigested sewage sludge is an environmentally attractive technology, particularly when heat is recovered from the process. Energy-conserving measures and recovery of excess oxygen from the SCWO process should be considered for improving the sustainability potential. 相似文献
18.
小叶榕落叶改性条件优化及其处理含Cu~(2+)废水动力学研究 总被引:1,自引:0,他引:1
以废弃的小叶榕落叶作为吸附剂,通过正交试验选择制备改性小叶榕落叶的最佳条件,结果表明:当硝酸浓度为10moL/L,干燥温度为120℃和氢氧化钠浓度为1moL/L时,改性后的小叶榕落叶的活性最强,对废水中Cu2+的吸附率最高。利用改性后的小叶榕落叶进行了吸附去除水中Cu2+的研究,得出当pH为5.7,铜的最大吸附容量Qmax=0.59mg(Cu)/g(改性落叶)。并通过非线性回归,构建了影响因素同吸附率之间的数学模型和落叶吸附的动力学模型。 相似文献
19.
Volatile organic compound emissions from wastewater treatment plants in Taiwan: legal regulations and costs of control 总被引:2,自引:0,他引:2
This study assessed volatile organic compound (VOC) emission characteristics from wastewater treatment plants (WWTPs) in five Taiwanese industrial districts engaged in numerous manufacturing processes, including petrochemical, science-based industry (primarily semiconductors, photo-electronics, electronic products and biological technology), as well as multiple manufacturing processes (primarily pharmaceuticals and paint manufacturing). The most aqueous hydrocarbons dissolved in the wastewater of Taiwanese WWTPs were acetone, acrylonitrile, methylene chloride, and chloroform for the petrochemical districts; acetone, chloroform, and toluene for the science-based districts; and chlorinated and aromatic hydrocarbons for the multiple industrial districts. The aqueous pollutants in the united WWTPs were closely related to the characteristics of the manufacturing plants in the districts. To effectively prevent VOC emissions from the primary treatment section of petrochemical WWTPs, the updated regulations governing VOC emissions were issued by the Taiwanese Environmental Protection Administration in September 2005, legally mandating a seal cover system incorporating venting and air purification equipment. Cost analysis indicates that incinerators with regenerative heat recovery are optimal for treating high VOC concentrations, exceeding 10,000ppm as CH(4), from the oil separation basins. However, the emission concentrations, ranging from 100 to 1000ppm as CH(4) from the other primary treatment facilities and bio-treatment stages, should be collected and then injected into the biological oxidation basins via existing or new blowers. The additional capital and operating costs required to treat the VOC emissions of 1000ppm as CH(4) from primary treatment facilities are less than US$0.1 for perm(3) wastewater treatment capacity. 相似文献
20.
Mohamed Kaddari Mahmoud El Mouden Abdelowahed Hajjaji 《International Journal of Green Energy》2017,14(10):839-844
This paper presents potential energy savings by installing high-efficiency motors instead of existing ones and their impact on greenhouse gases emissions reductions. This research study of the energy efficiency of electric motors has been performed in a typical thermal power plant. In the literature, the focus has been mainly on separate and away electric motors from operating facilities. The important advantage of this paper over other studies is that it uses the actual motors’ efficiency in the evaluation. The gains both in terms of electrical energy savings and in terms of financial economy by using high-efficiency motors have been discussed. As a result, the energy saving can be expected as 12.6% at the operating rate. This excellent result also reduces greenhouse gas emission by 1,423 tons every year. The analysis of the data provided an overview on energy losses often generated by the degradation and rewinding of electrical motors. This study represents very encouraging results that will help energy managers of industrial plants to become more involved in energy efficiency strategies. 相似文献