首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The partition and effective diffusion coefficients of formaldehyde were measured for three materials (conventional gypsum wallboard, “green” gypsum wallboard, and “green” carpet) under three relative humidity (RH) conditions (20%, 50%, and 70% RH). The “green” materials contained recycled materials and were friendly to environment. A dynamic dual-chamber test method was used. Results showed that a higher relative humidity led to a larger effective diffusion coefficient for two kinds of wallboards and carpet. The carpet was also found to be very permeable resulting in an effective diffusion coefficient at the same order of magnitude with the formaldehyde diffusion coefficient in air. The partition coefficient (K ma) of formaldehyde in conventional wallboard was 1.52 times larger at 50% RH than at 20% RH, whereas it decreased slightly from 50% to 70% RH, presumably due to the combined effects of water solubility of formaldehyde and micro-pore blocking by condensed moisture at the high RH level. The partition coefficient of formaldehyde increased slightly with the increase of relative humidity in “green” wallboard and “green” carpet. At the same relative humidity level, the “green” wallboard had larger partition coefficient and effective diffusion coefficient than the conventional wallboard, presumably due to the micro-pore structure differences between the two materials. The data generated could be used to assess the sorption effects of formaldehyde on building materials and to evaluate its impact on the formaldehyde concentration in buildings.

Implications: Based on the results of this study, the sink effects of these commonly used materials (conventional and “green” gypsum wallboards, “green” carpet) on indoor formaldehyde concentration could be estimated. The effects of relative humidity on the diffusion and partition coefficients of formaldehyde were found to differ for materials and for different humidity levels, indicating the need for further investigation of the mechanisms through which humidity effects take place.  相似文献   

2.
Aerosol light scattering measurements as a function of relative humidity   总被引:1,自引:0,他引:1  
The hygroscopic nature of atmospheric fine aerosol was investigated at a rural site in the Great Smoky Mountains National Park during July and August 1995. Passing the sample aerosol through an inlet, which housed an array of Perma Pure diffusion dryers, controlled the sample aerosol's relative humidity (RH). After conditioning the aerosol sample in the inlet, the light scattering coefficient and the aerosol size distribution were simultaneously measured. During this study, the conditioned aerosol's humidity ranged between 5% < RH < 95%. Aerosol response curves were produced using the ratio bspw/bspd; where bspw is the scattering coefficient measured at some RH greater than 20% and bspd is the scattering coefficient of the "dry" aerosol. For this work, any sample RH values below 15% were considered dry. Results of this investigation showed that the light scattering ratio increased continuously and smoothly over the entire range of relative humidity. The magnitude of the ratio at a particular RH value, however, varied considerably in time, particularly for RH values greater than approximately 60%. Curves of the scattering coefficient ratios as a function of RH were generated for each day and compared to the average 12-hour chemical composition of the aerosol. This comparison showed that for any particular RH value the ratio was highest during time periods of high sulfate concentrations and lowest during time periods of high soil or high organic carbon concentrations.  相似文献   

3.
The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S. Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. On the basis of a previous study, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high-performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using the natural log of the percent relative humidity (RH) and inverse of temperature (in K) as independent variables and the natural log of emission factors as the dependent variable. The coefficients for the inverse of temperature and log RH with log emission factor were found to be statistically significant for all of the samples at the 95% confidence level. This study should assist in retrospectively estimating indoor formaldehyde exposure of occupants of THUs.  相似文献   

4.
The diffusion coefficient, D, partition coefficient, K, and the initial volatile organic compounds (VOCs) in dry building materials, are the three key parameters used to predict the VOC emissions. D and K may be strongly affected by temperature. We have developed a new and simple method, the C-history method, to measure the diffusion coefficient, D and the partition coefficient, K of formaldehyde in dry building materials at temperatures of 18, 30, 40 and 50 °C. The measured variations of the diffusion coefficients and the partition coefficients with temperature for particle board, vinyl floor, medium- and high-density board are presented. A formula relating the partition coefficient and related factors is obtained through analysis. This formula can predict the partition coefficient in principle and provide an insight for fitting experimental data, and it agrees well with the experimental results.  相似文献   

5.
This paper describes a laboratory project to assess the accuracy of emission and indoor air quality models to be used in predicting formaldehyde (HCHO) concentrations in residences due to pressed-wood products made with urea-formaldehyde bonding resins. The products tested were partlcleboard underlayment, hardwood- plywood paneling and medium-density fiberboard (mdf). The products were initially characterized in chambers by measuring their formaldehyde surface emission rates over a range of formaldehyde concentrations, air exchange rates and two combinations of temperature and relative humidity (23° C and 5 0% RH; 26°C and 60% RH). They were then installed in a two-room prototype house in three different combinations (underlayment flooring only; underlayment flooring and paneling; and underlayment flooring, paneling, and mdf). The equilibrium formaldehyde concentrations were monitored as a function of air exchange rate. Particleboard underlayment and mdf, but not paneling, behaved as the emission model predicted over a large concentration range, under both sets of temperature and relative humidity. Good agreement was also obtained between measured formaldehyde concentrations and those predicted by a mass-balance indoor air quality model.  相似文献   

6.
Several buildings were contaminated with Bacillus anthracis in the fall of 2001. These events required consideration of how to disinfect large indoor spaces for continued worker occupation. The interactions of gaseous disinfectants with indoor materials may inhibit the disinfection process, cause persistence of the disinfectant, and lead to possible byproduct formation and persistence. Methyl bromide (CH3Br) is a candidate for disinfection/deactivation of biological agents in buildings. In this study, 24 indoor materials were exposed to CH3Br for 16 hr at concentrations ranging from 100 to 2500 ppm in 48-L electropolished stainless steel chambers. CH3Br concentrations were measured during and after disinfection. Its interactions with materials were observed to be small, with nearly complete and rapid desorption. Between 3% and 8% of CH3Br adsorbed to four materials (office partition, ceiling tile, particle-board, and gypsum wallboard with satin paint), and the degree of adsorption decreased with increasing relative humidity. The percentage of adsorption to all other materials was <2%. This result suggests that when designing disinfection events with CH3Br, loss to indoor materials can be neglected in terms of disinfectant dose calculations. Possible reaction products were identified and/or quantified before and after exposure to CH3Br. Several monomethylated and dimethylated aliphatic compounds were observed in chamber air at low concentrations after the exposures of six materials to CH3Br. Concentration increases also occurred for chemicals that were observed to naturally off-gas from materials before exposure to CH3Br, suggesting that CH3Br may play a role in enhancing the natural off-gassing of chemicals, for example, by competitive displacement of compounds that already existed in the materials. The results described in this paper should facilitate the design of building disinfection systems involving CH3Br.  相似文献   

7.
The effectiveness of gaseous ozone (O3) as a disinfectant was tested on Bacillus subtilis spores, which share the same physiological characteristics as Bacillus anthracis spores that cause the anthrax disease. Spores dried on surfaces of different carrier material were exposed to O3 gas in the range of 500-5000 ppm and at relative humidity (RH) of 70-95%. Gaseous O3 was found to be very effective against the B. subtilis spores, and at O3 concentrations as low as 3 mg/L (1500 ppm), approximately 3-log inactivation was obtained within 4 hr of exposure. The inactivation curves consisted of a short lag phase followed by an exponential decrease in the number of surviving spores. Prehydration of the bacterial spores has eliminated the initial lag phase. The inactivation rate increased with increasing O3 concentration but not >3 mg/L. The inactivation rate also increased with increase in RH. Different survival curves were obtained for various surfaces used to carry spores. Inactivation rates of spores on glass, a vinyl floor tile, and office paper were nearly the same. Whereas cut pile carpet and hardwood flooring surfaces resulted in much lower inactivation rates, another type of carpet (loop pile) showed significant enhancement in the inactivation of the spores.  相似文献   

8.
Goal, Scope and Background Reducing occupant exposure to indoor mold is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the problem. The efficacy of antimicrobial cleaners to remove, eliminate or control mold growth on surfaces can easily be tested on non-porous surfaces. However, the testing of antimicrobial cleaner efficacy on porous surfaces, such as those found in the indoor environment such as gypsum board can be more complicated and prone to incorrect conclusions regarding residual organisms. The mold Stachybotrys chartarum has been found to be associated with idiopathic pulmonary hemorrhage in infants and has been studied for toxin production and its occurrence in water damaged buildings. Growth of S. chartarum on building materials such as gypsum wallboard has been frequently documented. Methods Research to control S. chartarum growth using 13 separate antimicrobial cleaners on contaminated gypsum wallboard has been performed in laboratory testing. Popular brands of cleaning products were tested by following directions printed on the product packaging. Results A variety of gypsum wallboard surfaces were used to test these cleaning products at high relative humidity. The results indicate differences in antimicrobial efficacy for the six month period of testing. Discussion Results for the six types of GWB surfaces varied extensively. However, three cleaning products exhibited significantly better results than others. Lysol All-Purpose Cleaner-Orange Breeze (full strength) demonstrated results which ranked among the best in five of the six surfaces tested. Both Borax and Orange Glo Multipurpose Degreaser demonstrated results which ranked among the best in four of the six surfaces tested. Conclusions The best antimicrobial cleaner to choose is often dependent on the type of surface to be cleaned of S. chartarum contamination. For Plain GWB, no paint, the best cleaners were Borax, Lysol All-Purpose Cleaner-Orange Breeze (full strength), Orange Glo Multipurpose Degreaser, and Fantastik Orange Action. Recommendations and Perspectives These results are not meant to endorse the incomplete removal of mold contaminated building materials. However, it is recognized that complete removal may not always be possible and solutions to control mold regrowth may contribute to reduced occupant exposure. Current recommendations of removal and replacement of porous building materials should be followed. It is not the intension of this discussion to endorse any product. Reporting on the performance of these products under the stated conditions was and remains the only purpose. ESS-Submission Editor: Dr. Lee Young (youngrisk@bresnan.net)  相似文献   

9.
Abstract

Most of the synthetic gypsum generated from wet flue gas desulfurization (FGD) scrubbers is currently being used for wallboard production. Because oxidized mercury is readily captured by the wet FGD scrubber, and coal-fired power plants equipped with wet scrubbers desire to benefit from the partial mercury control that these systems provide, some mercury is likely to be bound in with the FGD gypsum and wallboard. In this study, the feasibility of identifying mercury species in the FGD gypsum and wallboard samples was investigated using a large sample size thermal desorption method. Potential candidates of pure mercury standards including mercuric chloride (HgCl2), mercurous chloride (Hg2Cl2), mercury oxide (HgO), mercury sulfide (HgS), and mercuric sulfate (HgSO4) were analyzed to compare their results with those obtained from FGD gypsum and dry wallboard samples. Although any of the thermal evolutionary curves obtained from these pure mercury standards did not exactly match with those of the FGD gypsum and wallboard samples, it was identified that Hg2Cl2 and HgCl2 could be candidates. An additional chlorine analysis from the gypsum and wallboard samples indicated that the chlorine concentrations were approximately 2 orders of magnitude higher than the mercury concentrations, suggesting possible chlorine association with mercury.  相似文献   

10.
There is scant information related to heterogeneous indoor chemistry at ozone concentrations necessary for the effective disinfection of buildings, i.e., hundreds to thousands of ppm. In the present study, 24 materials were exposed for 16 h to ozone concentrations of 1000–1200 ppm in the inlet streams of test chambers. Initial ozone deposition velocities were similar to those reported in the published literature for much lower ozone concentrations, but decayed rapidly as reaction sites on material surfaces were consumed. For every material, deposition velocities converged to a relatively constant, and typically low, value after approximately 11 h. The four materials with the highest sustained deposition velocities were ceiling tile, office partition, medium density fiberboard and gypsum wallboard backing. Analysis of ozone reaction probabilities indicated that throughout each experiment, and particularly after several hours of disinfection, surface reaction resistance dominated the overall resistance to ozone deposition for nearly all materials. Total building disinfection by-products (all carbonyls) were quantified per unit area of each material for the experimental period. Paper, office partition, and medium density fiberboard each released greater than 38 mg m−2 of by-products.  相似文献   

11.
Based on the extraction method presented by Smith et al. (2008), this paper proposes an improved method, the multi-emission/flush regression method, to simultaneously determine the initial emittable concentration and the partition coefficient. Compared to the extraction method, the proposed method has the following advantages: (1) it is unnecessary for the target volatile organic compounds (VOCs) to emit completely from the material, thus greatly reducing experimental time; (2) it provides a simpler way to obtain the partition coefficients of VOCs for tested materials and can avoid the measurement uncertainties at low VOC concentrations which often occur during the last few cycles of the extraction method; (3) it does not require grinding the building material into powders thus making this method more convenient to use. Comparisons were made between the initial emittable VOC concentrations determined by the original extraction method and the proposed method. Results show good agreements between these two methods. To further validate the proposed method, the type of static chamber developed by Wang et al. (2006) was used to conduct the experiment for a type of medium density board, and formaldehyde was selected as the target compound. Based on the initial emittable concentration and partition coefficient obtained using the proposed method, and the diffusion coefficient obtained by the mercury intruding porosimetry, the chamber formaldehyde concentration was predicted and compared with the experimental measurements. Results show that the predicted chamber VOC concentration using the measured parameters agree well with the experimental data.  相似文献   

12.
Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.  相似文献   

13.
Ozone concentrations that are several orders of magnitude greater than typical urban ambient concentrations are necessary for gas-phase ozonation of buildings, either for deodorization or for disinfection of biological agents. However, there is currently no published literature on the interaction of building materials and ozone under such extreme conditions. It would be useful to understand, for example in the case of building re-occupation planning, what types and amounts of reaction products may form and persist in a building after ozonation. In this study, 24 materials were exposed to ozone at concentrations of 1000 ppm in the inlet stream of experimental chambers. Fifteen target carbonyls were selected and measured as building ozonation by-products (BOBPs). During the 36 h that include the 16 h ozonation and 20 h persistence phase, the total BOBP mass released from flooring and wall coverings ranged from 1 to 20 mg m−2, with most of the carbonyls being of lower molecular weight (C1–C4). In contrast, total BOBP mass released from wood-based products ranged from 20 to 100 mg m−2, with a greater fraction of the BOBPs being heavier carbonyls (C5–C9). The total BOBP mass released during an ozonation event is a function of both the total surface area of the material and the BOBP emission rate per unit area of material. Ceiling tile, carpet, office partition, and gypsum wallboard with flat latex paint often have large surface areas in commercial buildings and these same materials exhibited relatively high BOBP releases. The greatest overall BOBP mass releases were observed for three materials that building occupants might have significant contact with: paper, office partition, and medium density fiberboard, e.g., often used in office furniture. These materials also exhibited extended BOBP persistence following ozonation; some BOBPs (e.g., nonanal) persist for months or more at emission rates large enough to result in indoor concentrations that exceed their odor threshold.  相似文献   

14.
The aim of this study was to measure the air concentrations of carbon dioxide (CO2) and formaldehyde (HCHO) in daycare centers to determine relevant influencing factors, including temperature, relative humidity (RH), type of facility, number of children, type of ventilation system, ventilation time, and air cleaning system. The authors measured HCHO, CO2, temperature, and RH in the center of classrooms in 289 daycare centers. Spearman’s correlation and Mann–Whitney analyses were used to examine the relationships and differences in HCHO and CO2 for varying temperatures, RH values, and categorical indoor environmental factors. There were no significant differences in the HCHO and CO2 air concentrations with varying numbers of children, ventilation times, or ventilation and air cleaning system types. However, both the HCHO and CO2 air concentrations were significantly different for varying RH values, which were divided into five categories (p < 0.001). Only the HCHO air concentrations were significantly different for varying temperatures, which were divided into five categories (p < 0.001). Significant correlations were found between HCHO air concentrations and the temperature (r = 0.35, p < 0.0001), RH (r = 0.51, p < 0.0001), and CO2 (r = 0.36, p < 0.0001). The study results support maintaining an appropriate temperature and RH range for reducing airborne HCHO in daycare centers. Further research is needed to elucidate the precise mechanisms responsible for the relationships observed in this study.

Implications: Data from 289 daycare centers in Seoul, South Korea, indicate that HCHO concentrations show a positive correlation with indoor temperature and relative humidity. This indicates that keeping temperatures low will help keep HCHO concentrations low, by both a direct and an indirect effect, since low temperatures also cause low relative humidity.  相似文献   


15.
Light extinction, which is the extent of attenuation of light signal for every distance traveled by light in the absence of special weather conditions (e.g., fog and rain), can be expressed as the sum of scattering and absorption effects of aerosols. In this paper, diurnal and seasonal variations of the extinction coefficient are investigated for the urban areas of Tehran from 2007 to 2009. Cases of visibility impairment that were concurrent with reports of fog, mist, precipitation, or relative humidity above 90 % are filtered. The mean value and standard deviation of daily extinction are 0.49 and 0.39 km?1, respectively. The average is much higher than that in many other large cities in the world, indicating the rather poor air quality over Tehran. The extinction coefficient shows obvious diurnal variations in each season, with a peak in the morning that is more pronounced in the wintertime. Also, there is a very slight increasing trend in the annual variations of atmospheric extinction coefficient, which suggests that air quality has regressed since 2007. The horizontal extinction coefficient decreased from January to July in each year and then increased between July and December, with the maximum value in the winter. Diurnal variation of extinction is often associated with small values for low relative humidity (RH), but increases significantly at higher RH. Annual correlation analysis shows that there is a positive correlation between the extinction coefficient and RH, CO, PM10, SO2, and NO2 concentration, while negative correlation exists between the extinction and T, WS, and O3, implying their unfavorable impact on extinction variation. The extinction budget was derived from multiple regression equations using the regression coefficients. On average, 44 % of the extinction is from suspended particles, 3 % is from air molecules, about 5 % is from NO2 absorption, 0.35 % is from RH, and approximately 48 % is unaccounted for, which may represent errors in the data as well as contribution of other atmospheric constituents omitted from the analysis. Stronger regression equation is achieved in the summer, meaning that the extinction is more predictable in this season using pollutant concentrations.  相似文献   

16.
Matrix diffusion is an important transport process in geologic materials of low hydraulic conductivity. For predicting the fate and transport of contaminants, a detailed understanding of the diffusion processes in natural porous media is essential. In this study, diffusive tracer transport (iodide) was investigated in a variety of geologically different limestone and sandstone rocks. Porosity, structural and mineralogical composition, hydraulic conductivity, and other rock properties were determined. The effective diffusion coefficients were measured using the time-lag method. The results of the diffusion experiments indicate that there is a close relationship between total porosity and the effective diffusion coefficient of a rock (analogous to Archie's Law). Consequently, the tortousity factor can be expressed as a function of total porosity. The relationship fits best for thicker samples (> 1.0 cm) with high porosities (> 20%), because of the reduced influence of heterogeneity in larger samples. In general, these correlations appear to be a simple way to determine tortuosity and the effective diffusion coefficient from easy to determine rock porosity values.  相似文献   

17.
The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods (Document 2.12) requires conditioning of PM2.5 filters at 20-23 degrees C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed +/-2 degrees C and +/-5% RH during the conditioning period. The quality assurance team at EPA Region 2's regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements. The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA's Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, +/-0.2 degrees C and +/-0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 microg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.  相似文献   

18.

Background, aim

The aims of the NORMACAT project are: to develop tools and unbiased standardized methods to measure the performance and to validate the safety of new materials and systems integrating photocatalysis, to develop new photocatalytic media with higher efficiency and to give recommendations aimed at improving the tested materials and systems.

Method

To achieve this objective, it was necessary to design standardized test benches and protocols to assess photocatalytic efficiency of materials or systems used in the treatment of volatile organic compounds (VOCs) and odour under conditions close to applications. The tests are based on the validation of robust analytical methods at the parts per billion by volume level that not only follow the disappearance of the initial VOCs but also identify the secondary species and calculate the mineralization rates.

Results

The first results of inter-laboratory closed chamber tests, according to XP B44-013 AFNOR standard, are described. The photocatalytic degradation of mixtures of several defined pollutants under controlled conditions (temperature, relative humidity, initial concentration) was carried out in two independent laboratories with the same photocatalytic device and with various analytical procedures. Comparison of the degradation rate and of the mineralization efficiency allowed the determination of the clean air delivery rate in both cases. Formaldehyde was the only by-product detected during photocatalytic test under standardized experimental conditions. The concentration of transient formaldehyde varied according to the initial VOC concentration. Moreover the photocatalytic reaction rate of formaldehyde in mixture with other pollutants was analysed. It was concluded that formaldehyde concentration did not increase with time.

Conclusion??perspective

This type of experiment should allow the comparison of the performances of different photoreactors and of photocatalytic media under controlled and reproducible conditions against mixtures of pollutants including formaldehyde.  相似文献   

19.
We used an environmental transmission electron microscope to observe deliquescence and hygroscopic growth of atmospheric particles with hygroscopic coatings over the range 0–100% relative humidity (RH). The particles were collected from polluted and clean environments. Types included a sulfate-coated NaCl/silicate aggregate particle, a sulfate-coated sea-salt particle, and a Mg-rich, chloride-coated sea-salt particle. They all exhibited initial water uptake between 50% and 60% RH, although the first major morphological changes occurred at 70% RH. A deliquescence sphere, adjacent to the core particle, formed between 70% and 76% RH when deliquescence occurred or when the liquid phase was able to break out of the solid exterior coating. The deliquescence sphere grew to engulf the particle with increasing RH. Some particles developed a splatter zone associated with a particle coating. Efflorescence occurred over the range 49–44% RH. Our results indicate that some coated particles undergo a multi-step deliquescence process and that composition of the different phases within the coating affects deliquescence and hygroscopic growth below 76% RH. Above 76% RH, the dominant hygroscopic growth was due to water uptake by NaCl. Efflorescence of these particles also was strongly linked to NaCl, although the presence of other phases inhibited formation of a single NaCl crystal. Our results show that the observed coatings can both enhance particle solubility and lower the effective deliquescence RH of the particle. Thus, these coatings cause important phase and size changes for aerosol particles that could feed back into many other chemical and physical processes that contribute to radiative forcing within the atmosphere.  相似文献   

20.
Deposition is an important process for the removal of aerosol particles. Negative air ion (NAI) generators can charge the ultrafine airborne particles and enhance their deposition rate. However, many NAI generators may also emit ozone and increase the concentration of particles in the presence of biogenic volatile organic compounds owing to the secondary organic aerosol (SOA) production. To validate the effectiveness of NAI generator, the authors investigated the enhancement effect of an NAI generator on the deposition of the ultrafine SOAs generated from the ozonolysis of d-limonene in a test chamber under controlled ventilation rate and relative humidity (RH). The experimental results demonstrated that compared with other effects, including the gravity, particle eddy diffusion, and the Brownian diffusion, the effect of NAIs is the most dominate one on the deposition of SOA particles onto the wall surface in the near-wall region (<1 cm away from the wall). According to these experiments, the tested NAI generator could efficiently enhance the deposition rate by an enhancement factor ranging from 8.17 ± 0.38 to 25.3 ± 1.1, with a low ozone production rate. This NAI generator had better performance on the deposition of the SOAs with smaller particle sizes and it performed even better under higher RH. The enhancement effect of the NAI generator was related to its high NAI production and electric field strength.

Implications: This study investigated a novel technique of negative air ion (NAI) generator that can enhance the precipitation of nano-scale secondary organic aerosol (SOA). The tested NAI generator can significantly improve the deposition rate of SOA with an enhancement factor of about 8.17 ± 0.38 to 25.3 ± 1.1. The enhancement factor rose when relative humidity increased.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号