共查询到20条相似文献,搜索用时 0 毫秒
1.
Microalgae as a main feedstock has attracted much attention in recent years but is still not economically feasible due to high algal culture cost. The objective of this study was to develop a comprehensive eco-friendly technology for cultivating microalgae Platymonas subcordiformis using aquaculture wastewater as growth medium for biomass and biofuel production. Platymonas subcordiformis was grown in pretreated flounder aquaculture wastewaters taken from different stages. Each of wastewater contained different levels of nutrients. The biomass yield of microalgae and associated nitrogen and phosphorous removal were investigated. The results showed that algal cell density increased 8.9 times than the initial level. Platymonas subcordiformis removed nitrogen and phosphorus from wastewater with an average removal efficiency of 87%-95% for nitrogen and 98%-99% for phosphorus. It was feasible to couple the removal of nitrogen and phosphorus from wastewater to algal biomass and biofuel production. However, further studies are required to make this technologies economically viable for algae biofuel production. 相似文献
2.
以海水养殖废水为研究对象,探究了微藻膜反应器的脱氮除磷效能及膜污染特性.采用青岛大扁藻(Platymonas helgolandica tsingtaoensis)作为生物源,经过60 d的运行,微藻膜反应器的TN和TP去除率分别为73.6%和77.9%,TN和TP去除速率达到15g·(m3·d)-1和2.8g·(m3·d)-1.反应器中的微藻能够较快富集,最大生长速率可达53.3mg·(L·d)-1,最大生物量可达1.4 g·L-1.第18d和38d分别对反应器中的微藻进行采收,未影响反应器的脱氮除磷效能,且可以在一定程度上缓解膜污染现象.微藻生物量的增加会显著提高膜污染物质的含量,三维荧光光谱结果表明,色氨酸类蛋白质和芳香类蛋白质是造成膜污染的重要因素. 相似文献
3.
城镇污水处理厂尾水排入水体后,尾水中的氮、磷仍易引起受纳水体富营养化问题,开展尾水深度处理以进一步去除氮、磷营养物质具有现实意义。通过试验研究了不同菌藻共培养对氮、磷的去除效果,筛选出优势菌藻组合,采用响应面法研究了通气量、光波长、细菌接种量对氮、磷去除效果的交互影响,提出最优参数组合,并建立菌藻共生系统,进行验证试验。结果表明:不同菌藻组合中,蛋白核小球藻-地衣芽胞杆菌-恶臭假单胞菌共培养组对TN、TP的去除效果较好;此菌藻共生系统在蓝光、通气量为1.8 L/min及细菌接种量为20%(体积比)条件下,TN去除率最大可达93.7%,1 d 后TP基本上完全被去除;在蓝光、通气量为2.0 L/min及细菌接种量为5%条件下,2 d后氮去除率可达98.4%;在红光、通气量为2.0~3.0 L/min及细菌接种量为10%~20%条件下,2 d后氨氮可完全被去除。菌藻共生系统对氮、磷去除效果的最优参数组合为蓝光、通气量为1.8 L/min及细菌接种量为20%,最优参数组合验证的结果与预测值相符,系统出水符合GB 3838—2002《地表水环境质量标准》Ⅴ类水质标准,可为菌藻共生系统的实际应用提供理论基础。
相似文献4.
生物膜反应器降解生物质气化洗焦废水 总被引:3,自引:1,他引:3
陶瓷球作为固定介质 ,接种本实验室保藏的Pseudomonassp1和Pseudomonassp2混合菌种 ,应用生物膜反应器处理生物质气化过程中产生的洗焦废水 ,对反应器运转整个过程的进出水COD浓度、进出水苯、萘、菲、吡啶、喹啉、异喹啉的含量、反应器内和反应器出水含菌量进行测定 ,以了解生物膜反应器处理生物质气化洗焦废水的特性 .结果表明 ,反应器经挂膜、增菌后 ,可达到稳定运转状态 ,有效的控制了反应器内微生物细胞的流失 ,使生物质气化洗焦废水中的有机物得到较好去除 . 相似文献
5.
6.
宏组学方法及在污水生物处理系统研究中的应用 总被引:1,自引:0,他引:1
近年来随着测序、质谱等技术的高速发展,基于核酸分子信息为基础的包含宏基因组学、宏转录组学、宏蛋白组学与代谢组学等核心内容的生物分子宏组学方法逐渐成熟,成为揭示污水生物处理系统中的关键微生物菌群结构和功能特征的有力工具,也在检测污水系统中多种ARGs以及探究其传播机制上发挥出无法替代的巨大优势,在污水生物处理研究中应用宏组学,对于深化认知污水处理系统本质、提高污水处理效率以及控制ARGs在环境中的传播具有重要指导意义.本文对宏组学方法进行了简单的介绍,着重综述了其在污水生物脱氮、强化生物除磷及探究抗生素抗性基因等方面的进展,并展望了其在污水生物处理系统中的广泛应用前景. 相似文献
7.
Addition of anaerobic tanks to an oxidation ditch system to enhance removal of phosphorus from wastewater 总被引:1,自引:0,他引:1
IntroductionEutrophicationofwaterbodieshasbeenattendedmanyyearsbyscientistsandthepublic .Phosphorusinthewaterbodiesoriginatesfromtheatmosphere,agricultureanddomesticandindustrialwastewater;domesticandindustrialwastewaterbeingthelargestsource .Therefore ,… 相似文献
8.
9.
10.
11.
12.
13.
基于城市污水资源化的微藻筛选与污水预处理 总被引:1,自引:2,他引:1
利用城市污水培养微藻,可在实现污水无害化处理的同时,培养微藻回收生物质能源.污水为微藻的培养提供氮、磷等营养组分和所需水源.由于城市污水含有大量的微生物,成分复杂,且不同藻种对污水的适应性与耐受性不同,因此,需要筛选出适宜于城市污水培养和高效产脂的藻种,并研究城市污水预处理方式,以使预处理后的城市污水更适于微藻的生长与产脂.本文根据课题组前期获得的藻种在城市污水中的生长与产脂情况以及对污水的净化能力筛选出适宜于城市污水培养的藻种.其中斜生栅藻(Scenedesmus obliquus)原始株与蛋白核小球藻(Chlorella pyrenoidosa)离子诱变藻株生物质与油脂产量较高,经污水培养后油脂产量分别可达0.43 g·L~(-1)、0.33 g·L~(-1),且含有较多的C16~C18脂肪酸,适宜于生物柴油的制备,同时可使培养后污水中COD、NH_4~+-N、TN、TP的去除率分别达到86.4%、100%、94.3%、93.4%和81.8%、100%、94.9%、94.2%.对可规模化扩大的污水预处理方式进行研究,发现不同藻种所最适的污水预处理方式不同.对于耐污性能较强的斜生栅藻原始株,除去粗大悬浮物后的城市污水即可用于其培养.对于蛋白核小球藻诱变株,城市污水经沉淀、过滤联合预处理后适宜于其培养. 相似文献
14.
15.
选择合适的污水处理工艺对污水处理厂的建设与运行有着关键的作用,通过对DEST工艺原理进行了介绍,同时结合某县污水厂工程实例对该工艺的设计参数、工艺特点进行了详细介绍和分析,并提出了该工艺的适用性以及设计中应注意的一些问题。 相似文献
16.
17.
城市污水处理厂化学强化生物除磷的试验研究 总被引:3,自引:0,他引:3
为有效解决北京某城市污水处理厂出水总磷含量较高的实际问题,通过在生物处理工艺(A2O)后端添加化学除磷强化单元的方法,依次开展了实验室试验和现场的生产性试验.实验室试验以好氧池出水为试验用水,对不同浓度梯度的聚合氯化铝(PAC)、聚合硫酸铁(PFS)、三氯化铁(FeCl3)等除磷效果进行了对比研究,并分别对其除磷机理进行了深入的探讨.试验结果表明:3种药剂中,PAC除磷效果最好,当其投加量为60mg/L,投加系数β为4.15时,出水总磷含量可小于0.5mg/L,而且药剂投加成本较低,仅为0.078元/t.现场生产性试验选取好氧池出水端为药剂投加点,对PAC的除磷效果进行现场验证.经试验测定,当PAC投加量为60mg/L,投加系数β为4.22时,污水处理厂出水总磷含量远低于0.5mg/L,符合排放要求.考虑到进水量和负荷的波动,在保证出水达标排放的前提下,为保证药剂的有效利用,通过采取针对性措施提高前端生物除磷效率及反馈投加药剂的方法,以有效减少药剂的投加量及化学污泥的排放量,达到节能减排的目的. 相似文献
18.
城市污水处理厂污泥臭氧减量技术研究 总被引:2,自引:1,他引:2
通过半连续式实验考察了臭氧投加量和初始pH对剩余污泥臭氧处理的影响.结果表明,随着臭氧投加量的增加,污泥溶解率增加,有机质、氮、磷等物质释放到污泥液相中;最佳臭氧投加量控制在约150 mg·g-1(以SS计),污泥溶解率可达约26%;污泥臭氧减量应在初始pH中性或偏碱性条件下进行,此时污泥溶解率较高,有利于有机质和氮的溶出.臭氧处理后污泥回流至生物处理系统对微生物的生物活性、COD和TN的去除效果无显著影响,但由于系统中无剩余污泥排放,导致TP的去除效果明显下降.臭氧处理后污泥上清液的Ca(OH)2除磷实验发现,较高的钙磷摩尔比对上清液除磷有利;当其值控制在10.0左右时,TP的去除率大于80%. 相似文献
19.
20.
一体化多级生物膜反应器处理高氮小城镇污水脱氮试验研究 总被引:5,自引:0,他引:5
采用新型一体化多级生物膜反应器处理高氮小城镇污水,在反应器中实现了高效的同步硝化反硝化脱氮,同时采用多点进水方式解决了脱氮低碳源问题.试验结果表明,在温度20℃,有机负荷(COD)为0.85 kg·m-3·d-1、氮负荷为0.27 kg·m-3·d-1、HRT为9h、分点进水条件下,可使进水COD为320 mg.L-1,TN为97 mg.L-1,NH;.N为84mg·L-1左右的高氮城镇污水,出水COD、TN、NH4 -N分别为16 mg·L-1、19.1mg·L-1、6.86 mg·L-1,达到国家一级排放B标准. 相似文献