共查询到20条相似文献,搜索用时 0 毫秒
1.
Background, aim and scope The applicability of the Whole Effluent Assessment concept for the proof of compliance with the “best available techniques” has been analysed with paper mill wastewater from Germany by considering its persistency (P), potentially bio-accumulative substances (B) and toxicity (T). 相似文献
2.
Biological treatment of antibiotic production effluents is an economical approach; however, there are still difficulties to overcome because of the recalcitrant characteristics of these compounds to biodegradation. This study aims to reveal that anaerobic treatment technology can be an option as pretreatment before the activated sludge system treatment to treat antibiotic production effluents. The ISO 8192 method was chosen to test the inhibitory effect of raw and treated antibiotic production effluents in this work. Inhibition tests, which were applied according to ISO 8192, highlighted that the anaerobic treatment effluent is less inhibitory than antibiotic production effluent for activated sludge system. Early EC 50 concentrations (30-min values) of raw and treated wastewaters were lower than 180-min values. Also, triple effects (sulfamethoxazole–erythromycin–tetracycline) of antibiotics are more toxic than dual effects (sulfamethoxazole–tetracycline). In light of the experimental results obtained and their evaluation, it can be concluded that anaerobic digestion can be applied as a biological pretreatment method for pharmaceutical industry wastewater including antibiotic mixtures prior to aerobic treatment. 相似文献
3.
Ozonation as final wastewater (WW) polishing step, following conventional activated sludge treatment is increasingly implemented in sewage treatment for contaminant degradation to prevent surface water pollution. While the oxidative degradation of chemicals has been extensively investigated, the in vivo toxicological characteristics of ozonated whole effluents are rarely a matter of research.In the present study, whole effluents were toxicologically evaluated with an in vivo test battery before and after full-scale ozonation and subsequent sand filtration on site at a treatment plant. One aquatic plant (duckweed, Lemna minor) and five invertebrate species of different systematic groups ( Lumbriculus variegatus, Chironomus riparius, Potamopyrgus antipodarum, Daphnia magna) were exposed to the effluents in a flow-through-designed test system with a test duration of 7-28 d.None of the considered toxicity endpoints correlated with the pollutant elimination. A tendency towards an increased toxicity after ozonation was apparent in three of the test systems showing [statistically] significant adverse effects in the L. variegatus toxicity test (decrease in reproduction and biomass). After sand filtration, adverse effects were reduced to a similar level like after conventional treatment. Solely the Daphnia reproduction test revealed beneficial effects after ozonation in combination with sand filtration.Results of the test battery indicate the formation of adverse oxidation products during WW ozonation. L. variegatus appeared to be the most sensitive of the five test species. Sand filtration effectively removes or detoxifies toxic oxidation products, as toxic effects were subsequently reduced to the level after conventional treatment. 相似文献
4.
Hydrodynamic forces generated by an orifice plate under low pressure were examined as a means of disrupting flocs, in order to improve disinfection of treated wastewater effluents. Changes in cavitation conditions were found to have little impact on the extent of particle breakage in this experimental setup. The rate of strain (flow rate divided by the hole radius cubed), however, was found to be the best predictor of floc breakage. Floc breakage was not affected by changes in floc concentration, but was very sensitive to differences between flocs collected from different sources. Larger flocs (90 to 106 microm) were broken apart to a greater extent than smaller ones (53 to 63 microm). Hydrodynamic treatment decreased the viability of bacteria associated with large flocs, and also increased the ultraviolet dose response by up to one log unit (i.e., a factor of ten). Subjecting final effluent wastewaters to hydrodynamic treatment, therefore, provides a treatment strategy for conditions in which the presence of flocs limits the level of disinfection that can be achieved. 相似文献
5.
Environmental Science and Pollution Research - Digital textile printing (DTP) is a game-changer technology that is rapidly expanding worldwide. On the other hand, process wastewater is rich in... 相似文献
6.
探讨了微生物絮凝剂处理二级出水过程中投加量和pH值对溶解性有机碳和浊度处理效果的影响,及将微生物絮凝剂与聚合氯化铝按不同比例复配后的去除效果及pH值对最佳投药量下去除效果的影响。并使用三维荧光光谱(3DEEM)分析了不同种类的絮凝剂在去除水中溶解性有机物(DOM)时的差别。实验结果表明:微生物絮凝剂的最佳投药量为20 mg·L-1,最适pH值为7.5,此时TOC去除率为17%,浊度去除率为45%。最佳复配投药量为微生物絮凝剂10 mg·L-1聚合氯化铝20 mg·L-1,最适pH值为7,此时TOC去除率为33%,浊度去除率为51%。复配使用对腐殖质有很好的去除效果。 相似文献
7.
残留的抗生素和新产生的抗生素代谢产物会通过不同的途径进入到环境中,污染环境,诱导产生一些耐药和变异的超级细菌,严重危害人类健康.梳理分析了污水处理厂出水中常见的抗生素种类,阐述了光降解抗生素的反应机理和影响抗生素光降解的因素,并从高效光转化材料的制备、光降解产物的精准识别和降解产物的生物毒性评估角度提出开展后续研究的建... 相似文献
8.
The main objective of this study was to examine the efficacy and capacity of using constructed wetlands on industrial pollutant removal. Four parallel pilot-scale modified free water surface (FWS) constructed wetland systems [dimension for each system: 4-m (L)x1-m (W)x1-m (D)] were installed inside an industrial park for conducting the proposed treatability study. The averaged influent contains approximately 170 mg l(-1) chemical oxygen demand (COD), 80 mg l(-1) biochemical oxygen demand (BOD), 90 mg l(-1) suspend solid (SS), and 32 mg l(-1) NH(3)-N. In the plant-selection study, four different wetland plant species including floating plants [Pistia stratiotes L. (P. stratiotes) and Ipomoea aquatica (I. aquatica)] and emergent plants [Phragmites communis L. (P. communis) and Typha orientalis Presl. (T. orientalis)] were evaluated. Results show that only the emergent plant (P. communis) could survive and reproduce with a continuous feed of 0.4m(3)d(-1) of the raw wastewater. Thus, P. communis was used in the subsequent treatment study. Two different control parameters including hydraulic retention time (HRT) (3, 5, and 7d) and media [vesicles ceramic bioballs and small gravels, 1cm in diameter] were examined in the treatment study. Results indicate that the system with a 5-d HRT (feed rate of 0.4m(3)d(-1)) and vesicles ceramic bioballs as the media had the acceptable and optimal pollutant removal efficiency. If operated under conditions of the above parameters, the pilot-plant wetland system can achieve removal of 61% COD, 89% BOD, 81% SS, 35% TP, and 56% NH(3)-N. The treated wastewater meets the current industrial wastewater discharge standards in Taiwan. 相似文献
9.
Textile plant wastewater being treated in a facultative pond system had too high of a solids concentration to be reused in the dying and rinsing processes. Electrocoagulation was evaluated to further treat the pond effluent to remove turbidity, which was caused by dyes and microorganisms. A range of amperages were tested for removal of turbidity and chemical oxygen demand (COD). Electrocoagulation lowered the turbidity from 1400 NTU to below 50 NTU; and COD was lowered from 550 mg/L to approximately 250 mg/L, which was acceptable for reuse. In addition, a laboratory-scale sedimentation study was conducted on the electrocoagulated pond effluent, which indicated that a settling time of 35 minutes would provide for 80% removal of suspended solids, which was acceptable for reuse of the water in plant processes. 相似文献
10.
Attempts were made in this study to examine the effectiveness of sequencing batch reactor (SBR) for the treatment of beverage industrial wastewater. The SBR was operated at three different organic loading rates (OLRs): 2, 1.7 and 1.1 kg COD/m3 d. Results of continuous long-term operation showed that by decreasing OLR from 2 to 1.7 kg COD/m3 day, the removal efficiency was increased from 95.5 to 99.3% for COD, from 95.3 to 98.1% for BOD and from 87 to 97.7% for TSS. While further decreasing of the OLR to 1.1 kg COD/m3 day, there is no significant adverse effect on organics removal. Also, residual total nitrogen (TN) concentration decreased by decreasing the OLR. However, increasing the OLRs exerted a slightly negative effect on the removal of total phosphorous. On the other hand, the experimental data indicated that the substrate utilization kinetic followed Monod's kinetics model approximately. The maximum specific substrate utilization rate (micro(max), half velocity coefficient (Ks), growth yield coefficient (Y) and decay coefficient (Kd) were 2.94 d(-1), 15.22 mg/L, 0.2384 g VSS/g COD and 0.2019 h(-1), respectively. 相似文献
11.
Synthetic crystalline hydrous ferric oxide (CHFO) (particle size 0.14 to 0.29 mm) has been used systematically for adsorptive chromium(VI) removal from contaminated water. Batch experiments were performed as a function of pH, contact time, solute concentration, and regeneration of adsorbents. Column experiments were performed for breakthrough points in the presence and absence of other ions and treatment of industrial effluent. The optimum pH range was 2.0 to 4.0. The adsorption kinetic data could be described well by both second-order and pseudo-first-order models. The isotherm adsorption data at 30 +/- 2 degrees C obeyed the Langmuir model best. The monolayer adsorption capacity was 35.7 mg/g. Chromium(VI)-rich CHFO could be regenerated up to 89 +/- 1% with 2.0 M sodium hydroxide. Regenerated column reuse showed a decrease (10 to 12%) in breakthrough capacity. Finally, the CHFO- (dried at 300 degrees C) packed column was used for the recovery (98.5 +/- 1.0%) of chromium(VI) from contaminated industrial waste effluent of Hindustan Motor Limited (Hooghly, West Bengal, India). 相似文献
12.
微絮凝 -直接过滤工艺是一种将混凝反应、沉淀截留集中在同一滤柱内同步完成的高效水处理工艺。该工艺应用于城市污水的深度处理中 ,通过絮凝剂的加入 ,具有同步去除PO3 -4 P、SS和部分COD的功能。本文研究了该工艺对二级处理出水中PO3 -4 P、SS和COD的去除效果及其规律。研究表明 :采用聚合氯化铁 (PFC)作为絮凝剂 ,当Fe/P摩尔比为 2∶1时 ,水中PO3 -4 P的去除率达 98.8% ,浓度可降至 0 .1mg/L以下 ,同时SS、COD去除率也有明显提高。与传统的混凝、沉淀除磷工艺相比 ,该工艺具有操作简单、结构紧凑、占地面积小、污泥量少等优点 ,是一种更为经济和简单的处理单元 ,适用于现有城市污水处理厂的除磷和进一步提高水质的深度处理 相似文献
13.
Many treatment technologies for wastewater containing heavy metals have been developed in recent years, but these technologies have some disadvantages, such as poor removing efficiency and complex operation. For this reason, a macromolecular heavy metal coagulant polyethyleneimine-sodium xanthogenate (PEX) was prepared by grafting a xanthogenate group to polyethyleneimine. It was determined that PEX has the function of removing both turbidity and copper ions. It was also determined that copper ions and turbidity have a cooperative removal effect with each other in the process of treating wastewater containing both turbidity and copper ions by PEX. The investigation showed that PEX is an amphoteric polyelectrolyte. At lower pH values, the amino groups of the macromolecule are electrically positive; therefore, turbidity is removed because of electroneutralization coagulation; at higher pH values, both amino groups and xanthogenic radical groups contribute to the removal of heavy metals, as a result of chelation. Compared with traditional chemical precipitation by calcium oxide and coagulation by an ordinary inorganic coagulant, PEX showed obvious advantages, for example, removing both turbidity and copper ions, higher removal efficiency, lower suitable pH value, and higher floc settlement velocity. 相似文献
14.
Three municipal wastewater treatment plants (WWTPs) in southeastern Pennsylvania were sampled to determine the presence and concentrations of 12 natural and synthetic estrogen hormones in the wastewater influent and effluent. The target estrogens were 17alpha-estradiol, estrone, estriol, equilin, 17alpha-dihydroequilin, 17beta-estradiol, 17alpha-ethinyl estradiol, gestodene, norgestrel, levonorgestrel, medrogestone, and trimegestone. One WWTP uses a biofilm reactor (packed-bed trickling filter),and the other two use suspended-growth media (continuously stirred activated sludge reactor and sequential batch reactor). Estrone was detected in all the three plants; estriol and estradiol were detected at two WWTPs; and 17 alpha-dihydroequilin and 17 alpha-ethinyl estradiol were detected at one WWTP. The concentration of estrogens in the influent and effluent of the three treatment plants ranged from 1.2 to 259 ng/L and 0.5 to 49 ng/L, respectively. The percentage removal of estrogens from the aqueous phase ranged from 41 to 99%, except in the case of 17alpha-dihydroequilin; the removal of 17alpha-dihydroequilin was negligible. The suspended-growth media systems showed higher removal efficiencies for estrogens than the biofilm system. The analytical method uses a Varian C-18 solid-phase extraction (Varian Inc., Palo Alto, California), followed by a derivatization with bis(trimethylsilyl)trifluoroacetamide. The detection limits for the estrogen compounds ranged from 0.1 to 10 ng/L using a sample size of 1 L. The method recoveries ranged from 71 to 120%, and the relative standard deviation ranged from 6 to 14% for all the hormones. 相似文献
15.
Dechlorinating agents and pH adjustment are often used to preserve wastewater samples for cyanide analysis. The effects of four approved preservation protocols on the results of the total cyanide analysis of effluents from four water reclamation plants were examined. The results differed widely, and a clear pattern emerged. Immediate analysis without pH adjustment generally gave total cyanide concentrations below the reporting limit of 5 microg/L, irrespective of the dechlorinating agents used. When the pH was adjusted to > or =12, a slight increase in the measured total cyanide concentration was observed when thiosulfate was used to dechlorinate the samples, and a significant increase (>10 microg/L) was observed when arsenite was used as the dechlorinating agent. These results provide evidence that approved preservation protocols may give rise to cyanide formation in chlorinated wastewater effluent matrices. 相似文献
16.
The concentrations and distribution of β-blockers, lipid regulators, and psychiatric and cancer drugs in the influent and effluent of the municipal wastewater treatment plant (WWTP) and the effluent of 16 hospitals that discharge into the wastewater treatment plant mentioned in this study at two sampling dates in summer and winter were examined. The pharmaceutical contribution of hospitals to municipal wastewater was determined. The removal of target pharmaceuticals was evaluated in a WWTP consisting of conventional biological treatment using activated sludge. Additionally, the potential environmental risk for the aquatic receiving environments (salt lake) was assessed. Beta-blockers and psychiatric drugs were detected in high concentrations in the wastewater samples. Atenolol (919 ng/L) from β-blockers and carbamazepine (7008 ng/L) from psychiatric pharmaceuticals were detected at the highest concentrations in hospital wastewater. The total pharmaceutical concentration determined at the WWTP influent and effluent was between 335 and 737 ng/L in summer and between 174 and 226 ng/L in winter. The concentrations detected in hospital effluents are higher than the concentrations detected in WWTP. The total pharmaceutical contributions from hospitals to the WWTP in summer and winter were determined to be 2% and 4%, respectively. Total pharmaceutical removal in the WWTP ranged from 23 to 54%. According to the risk ratios, atenolol could pose a high risk (risk quotient > 10) for fish in summer and winter. There are different reasons for the increase in pharmaceutical consumption in recent years. One of these reasons is the COVID-19 pandemic, which has been going on for 2 years. In particular, hospitals were operated at full capacity during the pandemic, and the occurrence and concentration of pharmaceuticals used for the therapy of COVID-19 patients has increased in hospital effluent. Pandemic conditions have increased the tendency of people to use psychiatric drugs. It is thought that beta-blocker consumption has increased due to cardiovascular diseases caused by COVID-19. Therefore, the environmental risk of pharmaceuticals for aquatic organisms in hospital effluent should be monitored and evaluated. 相似文献
17.
Environmental Science and Pollution Research - The goal of this work was to evaluate the performance of the LED irradiated photo-Fenton process on the removal of (i) estrogenic activity and (ii)... 相似文献
18.
磷酸铵镁沉淀法处理废水时常受众多因素影响,其中重金属类杂质对该过程影响较大。实验研究了Mn 2+、Cu 2+杂质存在条件下,用该法去除制药废水中PO 43-、NH 4+污染物,同时,用XRD、XRF、SEM等手段研究了所得鸟粪石晶体特征。结果表明,pH为9.5时,Mn 2+、Cu 2+杂质存在条件下,PO 43-去除率分别为88%和85%,投加晶种有利于回收特定晶形鸟粪石,Cu 2+对磷酸铵镁结晶过程的影响较Mn 2+存在时显著。 相似文献
19.
针对榨菜废水中较高的盐度对微生物的抑制和处理效能不稳定问题,开展电化学法处理高盐榨菜废水的实验研究。利用响应面法(RSM)探讨了榨菜废水COD的去除率与电流密度、极板间距和pH值之间的关系。通过Design-Ex-pert 7.1数据处理软件得到一个二次响应曲面模型以及优化的水平值。结果表明,最佳反应条件为电流密度为12.37 A/dm2,极板间距为18.82 mm,pH为5.92,此条件下COD去除率为83.21%(预测值为83.25%)。二次响应曲面方差分析结果表明,回归模型达到显著性水平,在研究区域内拟合较好,模型的精密度、可信度和精确度均在可行范围内,与实验结果吻合程度较高。 相似文献
20.
Iron electrodes were used for electrocoagulation (EC) treatment of wastewater from a dairy plant. Electrolysis time, pH, current density and distance between electrodes were considered to assess the removal efficiency of chemical oxygen demand (COD), total solids (TS) and their fractions and turbidity. Samples were collected from the effluent of a dairy plant using a sampling methodology proportional to the flow. The treatments were applied according to design factorial of half fraction with two levels of treatments and three repetitions at the central point. The optimization of parameters for treating dairy industry effluent by electrocoagulation using iron electrodes showed that electric current application for 15 minutes, an initial sample pH close to neutral (pH 7.0) and a current density of 50 A . m?2 resulted in a significant reduction in COD by 58 %; removal of turbidity, suspended solids and volatile suspended solids by 95 %; and a final treated effluent pH of approximately 9.5. Negative consequences of the type of electrode used were the emergence of an undesirable color and an increase in the proportion of dissolved solids in the treated effluent. 相似文献
|