首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper deals with a one-week monitoring of the 50 Hz magnetic field on the ground floor and the first floor of houses under 150, 220 and 380 kV high-voltage overhead three-phase AC transmission lines. The field strength varied with the current intensity, the conductor height, and the storey of the house. Because current intensity varies with time the magnetic field depended on the time of day and the day of the week. The recorded magnetic field ranged from 0.1 µT to 4.5 µT. The maximum value was at least 20 times weaker than the 100 µT exposure level recommended by the guidelines of the International Radiation Protection Association (IRPA) and about 140 times smaller than the 640 µT of the European Prestandard (CENELEC). The B-field was, for 99.9% of the measuring time, larger than the 0.2 µT cut-off point used to define categories of exposed and unexposed subjects in EMF epidemiological studies and, for 99.3% of the time, was greater than the 0.3 µT level used by US private engineering companies as the 'prudent avoidance' exposure limit. The weakest average magnetic field was at least 40 times larger than the 0.02 µT background value.  相似文献   

2.
Abstract

Wildfires and prescribed burns are receiving increasing attention as sources of fine particulate matter (PM2.5). The goal of this research project was to understand the impact of mitigation strategies for residences impacted by scheduled prescribed burns and wildfires. Pairs of residences were solicited to have PM2.5 concentrations monitored inside and outside of their houses during four fires. The effect of using air cleaners on indoor PM2.5 was investigated, as well as the effect of keeping windows closed. Appropriately sized air cleaners were provided to one of each pair of residences; occupants of all of the residences were asked to keep windows shut and minimize opening of exterior doors. Additionally, residents were asked to record all of the activities that may be a source of particulate matter, such as cooking and cleaning. Measurements were made during one prescribed burn and three wildfires during the 2002 fire season. Outdoor 24‐hr average PM2.5 concentrations ranging from 6 to 38 µg/m3 were measured during the fires, compared with levels of 2–5 µg/m3 during background measurements when no fires were burning. During the fires, PM2.5 was <3 µg/m3 inside all of the houses with air cleaners installed. This corresponds with a decrease of 63–88% in homes with the air cleaners operating when compared with homes without air cleaners. In the homes without the air cleaners, measured indoor concentrations were 58–100% of the concentrations measured outdoors.  相似文献   

3.
A dynamic multi-compartment computer model has been developed to describe the physical processes determining indoor pollutant concentrations as a function of outdoor concentrations, indoor emission rates and building characteristics. The model has been parameterised for typical UK homes and workplaces and linked to a time-activity model to calculate exposures for a representative homemaker, schoolchild and office worker, with respect to NO2. The estimates of population exposures, for selected urban and rural sites, are expressed in terms of annual means and frequency of hours in which air quality standards are exceeded. The annual mean exposures are estimated to fall within the range of 5–21 ppb for homes with no source, and 21–27 ppb for homes with gas cooking, varying across sites and population groups. The contribution of outdoor exposure to annual mean NO2 exposure varied from 5 to 24%, that of indoor penetration of outdoor air from 17 to 86% and that of gas cooking from 0 to 78%. The frequency of exposure to 1 h mean concentrations above 150 ppb was very low, except for people cooking with gas.  相似文献   

4.
ABSTRACT

A grading system was developed to rate the moisture damage profile of dwellings and to study the relationship between moisture-induced indoor air problems and occupant health. A total of 630 randomly selected houses and apartments, built between 1950 and 1989, were visually inspected. Moisture observations were standardized into three damage levels. Thus, a system to classify the homes into three grades was devised. The two grades of homes associated with the highest levels of damage were graded as index homes.

Overall, 51% of the sample had some kind of moisture fault in them and one in every three homes (33%) was classified as an index home. The mean number of damage incidents in the index dwellings varied from 1.4 to 2.6. The mean number of damage incidents in the reference homes was 0.28. Prevalence of index dwellings was significantly higher (p < 0.01) in houses (38%) than in apartments (26%). There was no major difference in the prevalence of index buildings in houses built in any particular decade (30-35%). Moisture was observed in 28% of bathrooms, in 10% of kitchens, and in 17% of other spaces. Indoor relative humidity (RH) levels were low in most homes.  相似文献   

5.

Background, aims, and scope

Preschool indoor air quality (IAQ) is believed to be different from elementary school or higher school IAQ and preschool is the first place for social activity. Younger children are more susceptible than higher-grade children and spend more time indoors. The purpose of this study was to compare the indoor air quality by investigating the concentrations of airborne particulates and gaseous materials at preschools in urban and rural locations in Korea.

Methods

We investigated the concentrations of airborne particulates and gaseous materials in 71 classrooms at 17 Korean preschools. For comparison, outdoor air was sampled simultaneously with indoor air samples. Airborne concentrations of total suspended particulates, respirable particulates, lead, asbestos, total volatile organic compounds and components, formaldehyde, and CO2 were measured with National Institute for Occupational Safety and Health and/or Environmental Protection Agency analytical methods.

Results

The concentration profiles of the investigated pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. The ratios of indoor/outdoor concentrations (I/O) of particulates and gaseous pollutants were characterized in urban and rural preschools. Total dust concentration was highest in urban indoor settings followed by urban outdoor, rural indoor, and rural outdoor locations with an I/O ratio of 1.37 in urban and 1.35 in rural areas. Although I/O ratios of lead were close to 1, lead concentrations were much higher in urban than in rural areas. The I/O ratio of total VOCs was 2.29 in urban and 2.52 in rural areas, with the highest level in urban indoor settings. The I/O ratio of formaldehyde concentrations was higher in rural than in urban areas because the outdoor rural level was much lower than the urban concentration. Since an I/O ratio higher than 1 implies the presence of indoor sources, we concluded that there are many indoor sources in preschools.

Conclusions

We confirmed that pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. Preschool children are expected to spend more time inside preschool facilities and therefore to be more exposed to pollutants. As far as we know, preschool IAQ is different from elementary school or higher school IAQ. Also, they are more vulnerable than higher-grade children. We found that the indoor and urban concentration profiles of the studied pollutants in preschools were higher than those in outdoor and rural areas. We believe that our findings may be useful for understanding the potential health effects of exposure and intervention studies in preschools.  相似文献   

6.
PM2.5 (particulate matter with an aerodynamic diameter <2.5 μm) samples were collected in the indoor environments of 15 urban homes and their adjacent outdoor environments in Alexandria, Egypt, during the spring time. Indoor and outdoor carbon dioxide (CO2) levels were also measured concurrently. The results showed that indoor and outdoor PM2.5 concentrations in the 15 sites, with daily averages of 45.5 ± 11.1 and 47.3 ± 12.9 µg/m3, respectively, were significantly higher than the ambient 24-hr PM2.5 standard of 35 µg/m3 recommended by the U.S. Environmental Protection Agency (EPA). The indoor PM2.5 and CO2 levels were correlated with the corresponding outdoor levels, demonstrating that outdoor convection and infiltration could lead to direct transportation indoors. Ventilation rates were also measured in the selected residences and ranged from 1.6 to 4.5 hr?1 with median value of 3.3 hr?1. The indoor/outdoor (I/O) ratios of the monitored homes varied from 0.73 to 1.65 with average value of 0.99 ± 0.26 for PM2.5, whereas those for CO2 ranged from 1.13 to 1.66 with average value of 1.41 ± 0.15. Indoor sources and personal activities, including smoking and cooking, were found to significantly influence indoor levels.

Implications: Few studies on indoor air quality were carried out in Egypt, and the scarce data resulted from such studies do not allow accurate assessment of the current situation to take necessary preventive actions. The current research investigates indoor levels of PM2.5 and CO2 in a number of homes located in the city of Alexandria as well as the potential contribution from both indoor and outdoor sources. The study draws attention of policymakers to the importance of the establishment of national indoor air quality standards to protect human health and control air pollution in different indoor environments.  相似文献   

7.
Heavy fuel oil and ash samples were collected from the Assiut thermal power plant in Egypt and subjected to gamma spectrometry analysis for natural radioactivity contents. Considerable results were observed where the ash contains nearly 1,000 times natural radionuclides more than raw oil. The results were confirmed by measuring the samples via using different devices in different institutions. All ash samples had radium equivalent activities and external hazard index values more than 370 Bq/kg and unity respectively. The mean absorbed dose rate was10,650 nGy/h which is nearly 190 times higher than the global average value of 55 nGy/h. The corresponding annual external effective dose is estimated to be 13 mSv/year, which is nearly 30 times higher than that in areas of natural background radiation (0.46 mSv/year).  相似文献   

8.
对乙酰丙酮分光光度法测定室内空气中甲醛的方法进行了优化,同时对北京市11户部分新装修居室室内空气中的甲醛含量进行了测定.结果表明,有8户住宅超过了我国室内空气质量标准GB/T18883-2002规定的甲醛最高容许质量浓度0.10 mg/m3.  相似文献   

9.
This study evaluates effects of good burning practice and correct installation and management of wood heaters on indoor air pollution in an Italian rural area. The same study attests the role of education in mitigating wood smoke pollution. In August 2007 and winters of 2007 and 2008, in a little mountain village of Liguria Apennines (Italy), indoor and outdoor benzene, toluene, ethylbenzene, and xylene (BTEX) concentrations were measured in nine wood-heated houses. During the first sampling, several mistakes in heating plant installations and management were found in all houses. Indoor BTEX concentrations increased during use of wood burning. Low toluene/benzene ratios were in agreement with wood smoke as main indoor and outdoor pollution source. Other BTEX sources were identified as the indoor use of solvents and paints and incense burning. Results obtained during 2007 were presented and discussed with homeowners. Following this preventive intervention, in the second winter sampling all indoor BTEX concentrations decreased, in spite of the colder outdoor air temperatures. Information provided to families has induced the adoption of effective good practices in stoves and fire management. These results highlight the importance of education, supported by reliable data on air pollution, as an effective method to reduce wood smoke exposures.
Implications:Information about burning practices and correct installation and management of wood heaters, supported by reliable data on indoor and outdoor pollution, may help to identify and remove indoor pollution sources. This can be an effective strategy in mitigate wood smoke pollution.  相似文献   

10.
The aims of this study were to explore the status of pollution and the temporal/spatial distribution of indoor and outdoor dust-Pb in the city of Kerman (SE Iran), located in a dry playa and arid climatic zone. Flat panes were laid at appropriate locations, in the indoor and the outdoor spaces of selected one-story houses in different areas of the city, to collect dust samples. Forty-two samples were taken and analyzed using the ICP-MS method. The measurements have shown that the outdoor dust-Pb concentrations varied from 23.7 to 275.2?mg kg?1, with a mean value of 71.8?mg kg?1, and indoor dust-Pb concentrations ranged from 47.6 to 150.2?mg kg?1, with a mean value of 89.6?mg kg?1. Based on these measurements, Pb was enriched in the outdoor and the indoor dust samples up to 48.8 and 29.4 times, respectively. Dilution, as a result of prevalence of geogenic dust in the outdoor space, is expected to be the main cause of the temporal differences. This study has shown that the eastern part of the city is more polluted compared to the other parts, and, because of the stable air conditions, the concentration of Pb in the summer dust is higher than the other seasons.  相似文献   

11.
Simultaneous measurements of indoor and outdoor carbon monoxide (CO) concentrations conducted at two different microenvironments in Athens, Greece, using a non-dispersive infrared analyzer, are described in this paper. The two selected microenvironments, an office and a public school, were located in the vicinity of two streets with heavy traffic, near the center of Athens. A statistical correlation analysis of indoor concentration levels with outdoor concentrations monitored at the school and at the office, as well as with meteorological parameters and outdoor concentrations monitored at a fixed monitoring site, was conducted. Hourly indoor concentrations at the office and at the school showed a significant positive correlation with outdoor concentrations measured at both measurement locations (with correlation coefficient values R=0.74 and R=0.83 respectively) and at the fixed site (with R=0.70 and R=0.67 respectively). The correlation between indoor and outdoor concentrations was even better when hourly concentrations averaged over a 4 h period were considered (correlation coefficient values between indoor and outdoor concentrations measured at the office and at the school were R=0.85 and R=0.92 respectively and the correlation coefficient value between indoor and outdoor fixed site concentrations was R=0.75 for both sites). Mean hourly outdoor concentrations at the fixed monitoring site explained approximately 56% (R=0.75) of the variation of outdoor concentrations at the office and approximately 68 % (R=0.83) of the variation of outdoor concentrations at the school. The mean daily indoor to outdoor (I/O) ratio ranged between 0.74 and 1.00 at the office and between 0.53 and 0.89 at the school.  相似文献   

12.
Abstract

In response to community concerns, the air quality impact of imploding a 22-story building in east Baltimore, MD, was studied. Time- and space-resolved concentrations of indoor and outdoor particulate matter (PM) (nominally 0.5–10 µm) were measured using a portable nephelometer at seven and four locations, respectively. PM10 levels varied in time and space; there was no measurable effect observed upwind of the implosion. The downwind peak PM10 levels varied with distance (54,000–589 µg/m3) exceeding pre-implosion levels for sites 100 and 1130 m 3000- and 20-fold, respectively. Estimated outdoor 24-hr integrated mass concentrations varied from 15 to 72 µg/m3. The implosion did not result in the U.S. Environmental Protection Agency (EPA) National Ambient Air Quality Standard (NAAQS) for PM10 being exceeded. X-ray fluorescence analysis indicated that the elemental composition was dominated by crustal elements: calcium (57%), silicon (23%), aluminum (7.6%), and iron (6.1%). Lead was above background but at a low level (0.17 µg/m3). Peak PM10 concentrations were short-lived; most sites returned to background within 15 min. No increase in indoor PM10 was observed even at the most proximate 250 m location. These results demonstrate that a building implosion can have a severe but short-lived impact on community air quality. Effective protection is offered by being indoors or upwind.  相似文献   

13.
Vertical gradients of volatile organic compounds (VOCs) were measured over a maize field and a soybean field in 1995 and 1996, respectively, in the Lower Coastal Plains of North Carolina. The measurements over the maize field were conducted in its early growth period, during May 1995, and the measurements over the soybean field were conducted in its middle and later growth periods during July through August 1996 at the same location. These measurements were combined with micrometeorological flux measurements to determine emission flux measurements for various VOCs. This measurement programme was part of project NOVA (Natural emissions of Oxidant precursors: Validation of techniques and Assessment) to estimate the flux of VOCs. Methanol was identified as the major biogenic compound for both years with the average flux of 3450 ± 1456 µg/m²/hr over maize and 3079 ± 2766 µg/m²/hr over soybean. Acetone is another compound that was identified as a biogenic compound for both years with the average flux of 425 ± 223 µg/m²/hr over maize and 2701 ± 1710 µg/m²/hr over soybean. In addition to biogenic compounds, a large number of aromatic compounds, including styrene and 1,2,4-trimethylbenzene, were also identified as emissions from the ground over the soybean field.  相似文献   

14.
The present study has been conducted in the frame of BUMA (Prioritization of Building Materials Emissions as indoor pollution sources), a European funded project, aiming at assessing the exposure to emitted compounds in indoor air. Field campaigns in five (5) European cities (Milan, Copenhagen, Dublin, Athens and Nicosia) were carried out. These campaigns covered weekly winter and summer concentration measurements in two (2) public buildings and two (2) private houses in each city. BTEX, terpenes, and carbonyls were measured using passive sampling in two sites inside the building and one outside. VOC emission measurements on selected building material have also been performed using Field and Laboratory Emission Cell (FLEC). The results on indoor concentrations for compounds such as formaldehyde (1.2–62.6 μg m?3), acetaldehyde (0.7–41.6 μg m?3), toluene (0.9–163.5 μg m?3), xylenes (0.2–177.5 μg m?3) and acetone (2.8–308.8 μg m?3) have shown diversity and relatively significant indoor sources depending on the building type, age etc. Indoor concentrations of these substances are varied depending on the building age and type. The percentage of approximately 40% of the indoor air quality levels originated from building materials.  相似文献   

15.
The effect of indoor exposure to nitrogen dioxide, ammonia, particulate matter and parental tobacco smoke on respiratory health was studied over a period of six months in all second graders born and living in two area of continental Croatia 8–10 yr of age. The study group was divided into two sections corresponding to area of residence (industrial/rural). Information on respiratory symptoms was collected from a self-administered questionnaire completed by the parents of the children. The mean values of concentrations of indoor air pollution that had been recorded in 24-h samples of air collected at schools were mostly below threshold limit for ambient pollution. In addition, information on parental smoking, the density of habitation and the type of fuel used for heating and/or cooking in the home was obtained by a questionnaire. In the investigated period the prevalence of respiratory illness was 22% in the children exposed to lower indoor air pollution and 25% in those exposed to higher indoor air pollution. Exposure to parental smoking was also associated with more respiratory symptoms (28 : 19%). The results indicate that the measured air pollutants only had a slight effect on the respiratory health of preadolescent children. However, the effect of exposure to parental smoking was more pronounced.  相似文献   

16.
The relationship between indoor and outdoor airborne particles was investigated for 16 residential houses located in a suburban area of Brisbane, Australia. The submicrometer particle numbers were measured using the Scanning Mobility Particle Sizer, the larger particle numbers using the Aerodynamic Particle Sizer and an approximation of PM2.5 was also measured using a DustTrak. The measurements were conducted for normal and minimum ventilation conditions using simultaneous and non-simultaneous measurement methods designed for the purpose of the study. Comparison of the ratios of indoor to outdoor particle concentrations revealed that while temporary values of the ratio vary in a broad range from 0.2 to 2.5 for both lower and higher ventilation conditions, average values of the ratios were very close to one regardless of ventilation conditions and of particle size range. The ratios were in the range from 0.78 to 1.07 for submicrometer particles, from 0.95 to 1.0 for supermicrometer particles and from 1.01 to 1.08 for PM2.5 fraction. Comparison of the time series of indoor to outdoor particle concentrations shows a clear positive relationship existing for many houses under normal ventilation conditions (estimated to be about and above 2 h−1), but not under minimum ventilation conditions (estimated to be about and below 1 h−1). These results suggest that for normal ventilation conditions, outdoor particle concentrations could be used to predict instantaneous indoor particle concentrations but not for minimum ventilation, unless air exchange rate is known, thus allowing for estimation of the “delay constant”.  相似文献   

17.
Occupational exposures to lead are characterised for a number of different lead-based paint abatement techniques in two work settings: residential renovation and structural steel demolition. Exposure levels reported during heavy structural steel demolition work involving acetylene torch cutting, welding, and abrasive blasting can be more than 100 times greater than the permissible exposure limit (PEL) set by the Occupational Safety and Health Administration (OSHA) for construction (200 µg/m³), which was in effect at the time of this study (the PEL was reduced to 50 µg/m³ in 1993). Surveillance data from an OSHA database for those standard industry classification (SIC) codes with a potential for exposure to lead-based paint in construction show that 49% of the air samples collected by OSHA were greater than 200 µg/m³, suggesting widespread non-compliance. New occupational exposure data from lead-based paint abatement work in public and private housing are also presented. In one public housing development, personal exposures to lead particulates measured during open flame burning and uncontained powered sanding were found to be more than 5000 µg/m³. These findings are contrasted with exposures measured during lead-based paint abatement work performed in accordance with the lead-based paint guidelines released by the US Department of Housing and Urban Development, where exposures were all lower than 25 µg/m³. Data from another public housing abatement project, involving work on 400 dwelling units over a 15-month period, show that workers' blood lead levels did not increase by more than 5 µg/dl above the pre-employment baseline. Abatement techniques studied here include interior and exterior building component replacement and exterior paint-stripping using a needle gun equipped with a high efficiency particulate air (HEPA) vacuum dust containment system. The data presented here show that it is feasible to keep airborne lead exposures below 20 µg/m³ in residential lead hazard control work, and to establish medical removal protection at blood lead levels of 25 µg/dl. These findings should be considered as OSHA finalises its interim final rule for lead exposure in construction work.  相似文献   

18.
Enhanced gamma (Δγ) ray dose rates due to 222Rn progeny wet deposited on the ground surface measured at six monitoring sites in Japan were statistically analyzed to investigate their temporal and spatial variations. Variations of Δγ ray dose rates indicated significant regional differences between the sites on the Sea of Japan coast and those located inland and on the Pacific coast in Japan. At the sites located on the Sea of Japan coast, significant seasonal variation was evident, with higher dose rates in autumn and winter, and lower dose rates in summer. In contrast, however, no significant seasonal variation was observed at the inland and Pacific coast sites in Japan. The variation of Δγ ray dose rates was characterized by three major factors: climatologically changed air masses arriving in Japan, variation of 222Rn and its progeny concentrations in the air column, and the regional characteristics of precipitation. It is evident that the contribution from local 222Rn to Δγ ray dose rates was smaller than those from continental 222Rn. Meso-scale atmospheric disturbance, however, was suggested as an important process for extremely high Δγ ray dose rates, possibly by the accumulation of additional local 222Rn with stronger convergence. It is therefore possible that the variation of Δγ ray dose rates reflects the chemical climatology of 222Rn and its progeny.  相似文献   

19.

Purpose  

Gamma ray irradiation is considered as an effective way to degrade diclofenac. However, due to the extensive coexisting substances in natural waters, the use of gamma ray irradiation for degradation is often influenced by multiple factors. The various factors that affect degradation efficiency, such as initial diclofenac concentration, initial pH, and the concentration of the additives including H2O2 (·OH radical promoter), CH3OH (·OH radical scavenger), thiourea (·OH, H·, and eaq scavenger), humic acid, and NO3 (coexisting substances in natural waters), are investigated. Furthermore, possible intermediate products are identified and corresponding transformation pathways are proposed.  相似文献   

20.
A grading system was developed to rate the moisture damage profile of dwellings and to study the relationship between moisture-induced indoor air problems and occupant health. A total of 630 randomly selected houses and apartments, built between 1950 and 1989, were visually inspected. Moisture observations were standardized into three damage levels. Thus, a system to classify the homes into three grades was devised. The two grades of homes associated with the highest levels of damage were graded as index homes. Overall, 51% of the sample had some kind of moisture fault in them and one in every three homes (33%) was classified as an index home. The mean number of damage incidents in the index dwellings varied from 1.4 to 2.6. The mean number of damage incidents in the reference homes was 0.28. Prevalence of index dwellings was significantly higher (p < 0.01) in houses (38%) than in apartments (26%). There was no major difference in the prevalence of index buildings in houses built in any particular decade (30-35%). Moisture was observed in 28% of bathrooms, in 10% of kitchens, and in 17% of other spaces. Indoor relative humidity (RH) levels were low in most homes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏