共查询到7条相似文献,搜索用时 15 毫秒
1.
The EU directives on air quality force member states to inform the public on the status of the ambient air quality. The Internet is commonly used for this purpose and often air quality is being presented as an index ranging from good to bad. A review of existing websites and air quality indices shows that the way air quality is interpreted differs considerably. The paper presents a new air quality index. The index is part of a project to develop a website dedicated to comparing air quality in European cities. The common air quality index (CAQI) is not aimed at replacing existing local indices. The CAQI is a set of two indices: one for roadside monitoring sites and one for average city background conditions. Differentiating between roadside and general city conditions is a first step in assuring consistence in the parameters that are being compared. 相似文献
2.
Robert C. Ward 《Regional Environmental Change》2001,2(2):66-72
Water quality criteria, as a means of distinguishing "good" water from "bad" water, have been employed for over 150 years.
During the 1940s and 1950s, the formulation of water quality criteria and their role in water quality management were hotly
debated in the United States as each state formulated its own approach to water pollution control. In 1965, when the federal
government assumed control of water quality management in the US, a single, national approach to the formulation and use of
criteria had to be selected and implemented nationwide. The purpose of this paper is to briefly review the history of criteria
as a basis for water quality management in the US; note the different water quality management philosophies used by states
prior to 1965; and summarize the relationship of criteria to monitoring over the past 30 years. Standards, as legal instruments,
are developed for a specific water body by designating a use of the water (society value) and the criteria necessary to protect
the use (a scientific finding). Standard violation, as a concept, tends to remain as a single-sample exercise (i.e., the sample
measurement is either above or below the standard). Increasingly, however, there is a demand to classify large bodies of water
(e.g., lake, river segment, or aquifer), over a set time period, such as a day, year, or decade, as either in compliance or
in violation of water quality standards. No peer-reviewed, standardized method for computing standard "violations" has been
widely accepted for this purpose. The paper ends with a call to develop such methods, if water quality managers must produce
standard violation information (infer sample results) over time and space.
Electronic Publication 相似文献
3.
This paper presents an assessment of air quality of the city Eskişehir, located 230 km southwest to the capital of Turkey. Only five of the major air pollutants, most studied worldwide and available for the region, were considered for the assessment. Available sulphur dioxide (SO2), particulate matter (PM), nitrogen dioxide (NO2), ozone (O3), and non-methane volatile organic carbons (NMVOCs) data from local emission inventory studies provided relative source contributions of the selected pollutants to the region.The contributions of these typical pollution parameters, selected for characterizing such an urban atmosphere, were compared with the data established for other cities in the nation and world countries. Additionally, regional ambient SO2 and PM concentrations, determined by semi-automatic monitoring at two sites, were gathered from the National Ambient Air Monitoring Network (NAAMN). Regional data for ambient NO2 (as a precursor of ozone as VOCs) and ozone concentrations, through the application of the passive sampling method, were provided by the still ongoing local air quality monitoring studies conducted at six different sites, as representatives of either the traffic-dense-, or coal/natural gas burning residential-, or industrial/rural-localities of the city. Passively sampled ozone data at a single rural site were also verified with the data from a continuous automatic ozone monitoring system located at that site. Effects of variations in seasonal-activities, newly established railway system, and switching to natural gas usage on the temporal changes of air quality were all considered for the assessment. Based on the comparisons with the national [AQCR (Air Quality Control Regulation). Ministry of Environment (MOE), Ankara. Official Newspaper 19269; 1986.] and a number of international [WHO (World Health Organization). Guidelines for Air Quality. Geneva; 2000. Downloaded in January 2006, website: http://www.who.int/peh/; EU (European Union). Council Directive 1999/30/EC relating to limit values for sulfur dioxide, nitrogen dioxide and lead in ambient air. Of J Eur Communities L 163: 14–30; 29.6.1999; EU (European Union). Council Directive 2002/3/EC relating to ozone in ambient air. Of J Eur Communities. L 67: 14–30; 9.3.2002.; USEPA (U.S. Environmental Protection Agency). National Ambient Air Quality Standards (NAAQS). Downloaded in January 2006, website: http://www.epa.gov/ttn/naaqs/] ambient air standards, among all the pollutants studied, only the annual average SO2 concentration was found to exceed one specific limit value (EU limit for protection of the ecosystem). A part of the data (VOC/NOx ratio), for determining the effects of photochemical interactions, indicated that VOC-limited regime was prevailing throughout the city. 相似文献
4.
Bell ML 《Environment international》2006,32(5):586-593
Ambient monitors are commonly used to estimate exposure for epidemiological studies, and air quality modeling is infrequently applied. However air quality modeling systems have the potential to alleviate some, although not all, of the limitations of monitoring networks. To investigate this application, exposure estimates were generated for a case study high ozone episode in the Northern Georgia Region of the United States based on measurements and concentration estimates from an air quality modeling system. Hourly estimates for 2268 4-km by 4-km gridcells were generated in a domain that includes only eight ozone monitors. Individual and population-based ozone exposures were estimated using multiple approaches, including area-weighted average of modeled estimates, nearest monitor, and spatial interpolation by inverse distance weighting and kriging. Results based on concentration fields from the air quality modeling system revealed spatial heterogeneity that was obscured by approaches based on the monitoring network. With some techniques, such as spatial interpolation, monitoring data alone was insufficient to estimate exposure for certain areas, especially for rural populations. For locations far from ozone monitors, the estimates from the nearest monitor approach tended to overestimate exposure, compared to modeled estimates. Counties in which one or more monitors were present had statistically higher population density and modeled ozone estimates than did counties without monitors (p-value <0.05). This work demonstrates the use of air quality modeling to generate higher spatial and temporal resolution exposure estimates, and compares the advantages of this approach to traditional methods that use monitoring data alone. The air quality modeling method faces its own limitations, such as the need to thoroughly evaluate concentration estimates and the use of ambient levels rather than personal exposure. 相似文献
5.
准确识别中美大气污染的空间交互影响可以为两国在大气污染治理领域开展双边合作提供科学依据。以PM 2.5浓度表征大气污染程度,采用收敛交叉映射(Convergent Cross Mapping,CCM)方法,在采集伯克利地球发布的小时数据的基础上通过算数平均得到2018年1月1日至2018年12月31日的PM 2.5浓度日均数据,从国家和城市两个层面识别了中美大气污染的空间交互影响。研究发现,中美两国的大气污染是空间交互影响的。其中,国家层面,在CCM因果检验基础上的广义同步检验表明,在1%显著性水平上,大气污染仅存在由美国指向中国的单向因果关系。城市层面,中美两国10个样本城市之间理论上共存在50个可能的因果关系(5×5×2)。研究发现,在1%显著性水平上,美国城市指向中国城市的因果关系有12个,而中国城市指向美国城市的因果关系仅有5个。在影响强度上,美国城市的大气污染对中国城市的影响强度高于中国城市的大气污染对美国城市的影响强度,如重庆的大气污染对华盛顿的影响强度为0.21,而华盛顿的大气污染对重庆的影响强度为0.35。面对大气污染的空间交互影响,中美两国可通过积极开展联合科研攻关,厘清大气污染的传输路径及其驱动因素,进行污染物的联合监测与数据管理;通过共享大气污染治理技术和建立大气污染防治基金等方式,加强在大气污染治理领域的合作。一旦中美两国成功建立起大气污染双边合作治理体系,依靠两国的国际地位和国际影响力,必将吸引越来越多的国家参与进来共同行动,大气污染全球治理体系的构建将非常值得期待。 相似文献
6.
This study investigates the contribution of radon (222Rn)-bearing water to indoor 222Rn in thermal baths. The 222Rn concentrations in air were monitored in the bathroom and the bedroom. Particulate matter (PM, both PM10 and PM2.5) and carbon dioxide (CO2) were also monitored with portable analyzers. The bathrooms were supplied with hot spring water containing 66-260 kBq m−3 of 222Rn. The results show that the spray of hot spring water from the bath spouts is the dominant mechanism by which 222Rn is released into the air of the bathroom, and then it diffuses into the bedroom. Average 222Rn level was 110-410% higher in the bedrooms and 510-1200% higher in the bathrooms compared to the corresponding average levels when there was no use of hot spring water. The indoor 222Rn levels were influenced by the 222Rn concentrations in the hot spring water and the bathing times. The average 222Rn transfer coefficients from water to air were 6.2 × 10−4-4.1 × 10−3. The 24-h average levels of CO2 and PM10 in the hotel rooms were 89% and 22% higher than the present Indoor Air Quality (IAQ) standard of China. The main particle pollutant in the hotel rooms was PM2.5. Radon and PM10 levels in some hotel rooms were at much higher concentrations than guideline levels, and thus the potential health risks to tourists and especially to the hotel workers should be of great concern, and measures should be taken to lower inhalation exposure to these air pollutants. 相似文献
7.
T. I. Moiseenko 《Russian Journal of Ecology》2008,39(6):390-397
A methodological approach to water quality assessment within the scope of the ecosystem health concept is substantiated. Key tasks in water body pollution rating are specified. A rationale for the system of criteria for the diagnosis of aquatic ecosystem health is given on the basis of analysis of determinate changes in their organization levels under anthropogenic stress. The results of testing the proposed methods in water objects of the Volga basin and Lake Imandra are described. 相似文献