首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Because landfill gas (LFG) contains an abundance of methane, the utilization of LFG as a renewable energy source is becoming popular in many countries. LFG, however, contains various trace constituents, some of which may pose problems during utilization. For example, siloxanes and halogenated volatile organic compounds (VOCs) can cause difficulties when present in the fuel of gas engines. In addition, many VOCs and mercury have harmful effects on human health, especially on the health of workers at landfill sites and people living near the landfills. Energy recovery from LFG is expected to make great progress in the near future, particularly in Asia, but we found little information on the trace constituents of LFG in this region. Therefore, we sought to characterize the trace components in LFG generated in two landfill sites in China and one site in Japan, to determine the typical concentrations of these trace components in LFG, and to compare their concentrations among landfill sites in Asia. We concluded that the trace components in LFG at the sites studied were mainly siloxanes generated from sewage sludge and harmful benzene, toluene, ethylbenzene, and xylene compounds from petroleum products.  相似文献   

2.
In the combustion facilities, halogens (Cl, F, Br, I) should be considered with regard to the control of the compounds such as polychlorinated dibenzodioxins (PCDD), polychlorinated dibenzofurans (PCDF), halogenated polyaromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB) and volatile heavy metals formed as a result of incomplete combustion and caused adverse environmental effects. In this study halogens were observed in Izmit Hazardous and Clinical Waste Incinerator (IZAYDAS). Halogen contents of the combustion menu, flue gas, fly ash, bottom ash and filter cake were measured and their distributions in these exit streams were determined. Results showed that the major part of the halogens was partitioned to solid residues, i.e., bottom ash and filter cake which represents the removal by wet scrubbers. Fly ash and flue gas fractions of halogens were much lower due to the reduced formation of volatile compounds.  相似文献   

3.
The current landfill gas (LFG) management (based on flaring and utilization for heat generation of the collected gas) and three potential future gas management options (LFG flaring, heat generation and combined heat and power generation) for the Old Ämmässuo landfill (Espoo, Finland) were evaluated by life-cycle assessment modeling. The evaluation accounts for all resource utilization and emissions to the environment related to the gas generation and management for a life-cycle time horizon of 100 yr. The assessment criteria comprise standard impact categories (global warming, photo-chemical ozone formation, stratospheric ozone depletion, acidification and nutrient enrichment) and toxicity-related impact categories (human toxicity via soil, via water and via air, eco-toxicity in soil and in water chronic).The results of the life-cycle impact assessment show that disperse emissions of LFG from the landfill surface determine the highest potential impacts in terms of global warming, stratospheric ozone depletion, and human toxicity via soil. Conversely, the impact potentials estimated for other categories are numerically-negative when the collected LFG is utilized for energy generation, demonstrating that net environmental savings can be obtained. Such savings are proportional to the amount of gas utilized for energy generation and the gas energy recovery efficiency achieved, which thus have to be regarded as key parameters. As a result, the overall best performance is found for the heat generation option – as it has the highest LFG utilization/energy recovery rates – whereas the worst performance is estimated for the LFG flaring option, as no LFG is here utilized for energy generation.Therefore, to reduce the environmental burdens caused by the current gas management strategy, more LFG should be used for energy generation. This inherently requires a superior LFG capture rate that, in addition, would reduce fugitive emissions of LFG from the landfill surface, bringing further environmental benefits.  相似文献   

4.
The objectives of this study were to compare the types and levels of volatile methyl siloxanes (VMS) present in biogas generated in the anaerobic digesters and landfills, evaluate the energetics of siloxane transformations under anaerobic conditions, compare the conditions in anaerobic digesters and municipal solid waste (MSW) landfills which result in differences in siloxane compositions. Biogas samples were collected at the South District Wastewater Treatment Plant and South Dade Landfill in Miami, Florida. In the digester gas, D4 and D5 comprised the bulk of total siloxanes (62% and 27%, respectively) whereas in the landfill gas, the bulk of siloxanes were trimethylsilanol (TMSOH) (58%) followed by D4 (17%). Presence of high levels of TMSOH in the landfill gas indicates that methane utilization may be a possible reaction mechanism for TMSOH formation. The free energy change for transformation of D5 and D4 to TMSOH either by hydrogen or methane utilization are thermodynamically favorable. Either hydrogen or methane should be present at relatively high concentrations for TMSOH formation which explains the high levels present in the landfill gas. The high bond energy and bond distance of the Si–O bond, in view of the atomic sizes of Si and O atoms, indicate that Si atoms can provide a barrier, making it difficult to break the Si–O bonds especially for molecules with specific geometric configurations such as D4 and D5 where oxygen atoms are positioned inside the frame formed by the large Si atoms which are surrounded by the methyl groups.  相似文献   

5.
The content of readily volatile halogenated hydrocarbons (chlorinated and chlorinated, fluorinated hydrocarbons (VCCs/CFCs)) and the BTEX aromatic substances (benzene, toluene, ethylbenzene and xylene) in municipal solid waste (MSW) was determined by two different methods. Moreover, the emission potential of these substances via the gas and leachate phase was investigated during the different biological degradation phases in the landfill. Trichlorofluoromethane (R11), dichlorodifluoromethane (R12) and dichloromethane (R30) were the dominating halogenated trace substances detected in the MSW. In the acid phase, with some VCCs/CFCs the emittance may take place up to 30% via the water phase. Hexane, benzene, and toluene could be detected in all tests. Toluene often occurred in relatively high concentrations in MSW. It could be shown that R11 degraded into dichlorofluoromethane (R21).  相似文献   

6.
This paper focuses on the development of an on-line measurement method for siloxanes and other biogas trace compounds impeding the energy utilisation of biogas, as well as the main gas components, methane and carbon dioxide. The method is based on gas chromatography and FT-IR-analysis. The level of siloxane, hydrogen sulphide and halogens in biogas generated in a number of landfills and digesters in Finland is also presented and factors affecting the concentrations discussed. Generally, the level of biogas trace compounds hampering electricity production was lower than those measured at comparable sites in Central Europe and the US. Moreover, the paper discusses the significance of on-line monitoring of siloxane in connection to biogas-to-electricity applications and points out with activated carbon as an example the benefits of on-line siloxane measurement in the control of siloxane removal technology.  相似文献   

7.
In addition to methane (CH(4)) and carbon dioxide (CO(2)), landfill gas may contain more than 200 non-methane organic compounds (NMOCs) including C(2+)-alkanes, aromatics, and halogenated hydrocarbons. Although the trace components make up less than 1% v/v of typical landfill gas, they may exert a disproportionate environmental burden. The objective of this work was to study the dynamics of CH(4) and NMOCs in the landfill cover soils overlying two types of gas collection systems: a conventional gas collection system with vertical wells and an innovative horizontal gas collection layer consisting of permeable gravel with a geomembrane above it. The 47 NMOCs quantified in the landfill gas samples included primarily alkanes (C(2)-C(10)), alkenes (C(2)-C(4)), halogenated hydrocarbons (including (hydro)chlorofluorocarbons ((H)CFCs)), and aromatic hydrocarbons (BTEXs). In general, both CH(4) and NMOC fluxes were all very small with positive and negative fluxes. The highest percentages of positive fluxes in this study (considering all quantified species) were observed at the hotspots, located mainly along cell perimeters of the conventional cell. The capacity of the cover soil for NMOC oxidation was investigated in microcosms incubated with CH(4) and oxygen (O(2)). The cover soil showed a relatively high capacity for CH(4) oxidation and simultaneous co-oxidation of the halogenated aliphatic compounds, especially at the conventional cell. Fully substituted carbons (TeCM, PCE, CFC-11, CFC-12, CFC-113, HFC-134a, and HCFC-141b) were not degraded in the presence of CH(4) and O(2). Benzene and toluene were also degraded with relative high rates. This study demonstrates that landfill soil covers show a significant potential for CH(4) oxidation and co-oxidation of NMOCs.  相似文献   

8.
Quantifying landfill gas to energy (LFGTE) potential as a source of renewable energy is difficult due to the challenges involved in modeling landfill gas (LFG) generation. In this paper a methodology is presented to estimate LFGTE potential on a regional scale over a 25-year timeframe with consideration of modeling uncertainties. The methodology was demonstrated for the US state of Florida, as a case study, and showed that Florida could increase the annual LFGTE production by more than threefold by 2035 through installation of LFGTE facilities at all landfills. The estimated electricity production potential from Florida LFG is equivalent to removing some 70 million vehicles from highways or replacing over 800 million barrels of oil consumption during the 2010-2035 timeframe. Diverting food waste could significantly reduce fugitive LFG emissions, while having minimal effect on the LFGTE potential; whereas, achieving high diversion goals through increased recycling will result in reduced uncollected LFG and significant loss of energy production potential which may be offset by energy savings from material recovery and reuse. Estimates showed that the power density for Florida LFGTE production could reach as high as 10 Wm(-2) with optimized landfill operation and energy production practices. The environmental benefits from increased lifetime LFG collection efficiencies magnify the value of LFGTE projects.  相似文献   

9.
采用顶空-气相色谱-质谱联用技术,针对3家石油化工企业的38个循环水样进行了VOCs的定性、定量分析。结果表明,石化企业循环水中主要含有烷烃、烯烃、卤代烃、芳香烃、含氧有机物等5类物质,其中卤代烃占总量的67%(w),芳香烃化合物占24%(w),烃类化合物、含氧化合物含量比较低,分别占4%(w)。本研究进一步完善了我国VOCs排放源成分谱,同时也为石化企业循环水中VOCs的管控提供了数据支持。  相似文献   

10.
Landfill gas (LFG) control measures and operating experience are described for two landfill sites which have been developed in the City of Carson, California. Investigations began in 1975 to develop a completed 10.5-ha Class II landfill site (household and commercial wastes) as a six-screen drive-in theatre including projection and concession facilities. LFG control facilities include 30 extraction wells for on-site protection, 19 perimeter extraction wells for migration control, blower/flare facilities and a subslab membrane and automatic gas detection system for backup protection during active system downtime.Investigations for the second site began in 1977 to develop 3.8 ha of a 7.2-ha Class II landfill site as a truck sales and service centre. LFG control facilities include 14 extraction wells, blower/flare facilities and a subslab membrane.Ongoing operation and maintenance of LFG control facilities is required at both sites to permit continued site occupancy. Activities include blower/flare maintenance, well field monitoring and adjustment, site settlement inspection and repair, monitoring system calibration and maintenance, etc.Buildings at both locations are supported on foundation piles driven through the former landfilled materials.  相似文献   

11.
Many developed countries have targeted landfill methane recovery among greenhouse gas mitigation strategies, since methane is the second most important greenhouse gas after carbon dioxide. Major questions remain with respect to actual methane production rates in field settings and the relative mass of methane that is recovered, emitted, oxidized by methanotrophic bacteria, laterally migrated, or temporarily stored within the landfill volume. This paper presents the results of extensive field campaigns at three landfill sites to elucidate the total methane balance and provide field measurements to quantify these pathways. We assessed the overall methane mass balance in field cells with a variety of designs, cover materials, and gas management strategies. Sites included different cell configurations, including temporary clay cover, final clay cover, geosynthetic clay liners, and geomembrane composite covers, and cells with and without gas collection systems. Methane emission rates ranged from -2.2 to >10,000 mg CH(4) m(-2) d(-1). Total methane oxidation rates ranged from 4% to 50% of the methane flux through the cover at sites with positive emissions. Oxidation of atmospheric methane was occurring in vegetated soils above a geomembrane. The results of these studies were used as the basis for guidelines by the French environment agency (ADEME) for default values for percent recovery: 35% for an operating cell with an active landfill gas (LFG) recovery system, 65% for a temporary covered cell with an active LFG recovery system, 85% for a cell with clay final cover and active LFG recovery, and 90% for a cell with a geomembrane final cover and active LFG recovery.  相似文献   

12.
Pilot-scale experiment on anaerobic bioreactor landfills in China   总被引:1,自引:0,他引:1  
Developing countries have begun to investigate bioreactor landfills for municipal solid waste management. This paper describes the impacts of leachate recirculation and recirculation loadings on waste stabilization, landfill gas (LFG) generation and leachate characteristics. Four simulated anaerobic columns, R1-R4, were each filled with about 30 tons of waste and recirculated weekly with 1.6, 0.8 and 0.2m(3) leachate and 0.1m(3) tap water. The results indicated that the chemical oxygen demand (COD) half-time of leachate from R1 was about 180 days, which was 8-14 weeks shorter than that of R2-R4. A large amount of LFG was first produced in R1, and its generation rate was positively correlated to the COD or volatile fatty acid concentrations of influent leachates after the 30th week. By the 50th week of recirculation, the waste in R1 was more stabilized, with 931.2 kg COD or 175.6 kg total organic carbon released and with the highest landfill gas production. However, this contributed mainly to washout by leachate, which also resulted in the reduction of LFG generation potential and accumulation of ammonia and/or phosphorus in the early stage. Therefore, the regimes of leachate recirculation should be adjusted to the phases of waste stabilization to enhance efficiency of energy recovery. Integrated with the strategy of in situ leachate management, extra pre-treatment or post-treatment methods to remove the nutrients are recommended.  相似文献   

13.
This paper examines landfill gas (LFG) emissions at a large inactive waste disposal site to evaluate the viability of investment in LFG recovery through the clean development mechanism (CDM) initiative. For this purpose, field measurements of LFG emissions were conducted and the data were processed by geospatial interpolation to estimate an equivalent site emission rate which was used to calibrate and apply two LFG prediction models to forecast LFG emissions at the site. The mean CH(4) flux values calculated through tessellation, inverse distance weighing and kriging were 0.188±0.014, 0.224±0.012 and 0.237±0.008lCH(4)/m(2)hr, respectively, compared to an arithmetic mean of 0.24l/m(2)hr. The flux values are within the reported range for closed landfills (0.06-0.89l/m(2)hr), and lower than the reported range for active landfills (0.42-2.46l/m(2)hr). Simulation results matched field measurements for low methane generation potential (L(0)) values in the range of 19.8-102.6m(3)/ton of waste. LFG generation dropped rapidly to half its peak level only 4yrs after landfill closure limiting the sustainability of LFG recovery systems in similar contexts and raising into doubt promoted CDM initiatives for similar waste.  相似文献   

14.
Methane (CH4) diffuse emissions from Municipal Solid Waste (MSW) landfills represent one of the most important anthropogenic sources of greenhouse gas. CH4 is produced by anaerobic biodegradation of organic matter in landfilled MSW and constitutes a major component of landfill gas (LFG). Gas recovery is a suitable method to effectively control CH4 emissions from landfill sites and the quantification of CH4 emissions represents a good tool to evaluate the effectiveness of a gas recovery system in reducing LFG emissions. In particular, LFG emissions can indirectly be evaluated from mass balance equations between LFG production, recovery and oxidation in the landfill, as well as by a direct approach based on LFG emission measurements from the landfill surface. However, up to now few direct measurements of landfill CH4 diffuse emissions have been reported in the technical literature. In the present study, both modeling and direct emission measuring methodologies have been applied to the case study of Bellolampo landfill located in Palermo, Italy. The main aim of the present study was to evaluate CH4 diffuse emissions, based on direct measurements carried out with the flux accumulation chamber (static, non-stationary) method, as well as to obtain the CH4 contoured flux map of the landfill. Such emissions were compared with the estimate achieved by means of CH4 mass balance equations. The results showed that the emissions obtained by applying the flux chamber method are in good agreement with the ones derived by the application of the mass balance equation, and that the evaluated contoured flux maps represent a reliable tool to locate areas with abnormal emissions in order to optimize the gas recovery system efficiency.  相似文献   

15.
The current food waste leachate (FWL) disposal practice in Korea warrants urgent attention and necessary action to develop an innovative and sustainable disposal strategy, which is both environmentally friendly and economically beneficial. In this study, methane production by FWL injection into a municipal solid waste landfill with landfill gas (LFG) recovery facility was evaluated for a period of more than 4 months. With the target of recovering LFG with methane content ~50%, optimum LFG extraction rate was decided by a trial and error approach during the field investigation in five different phases. The results showed that, upon FWL injection, LFG extraction rate of ~20 m(3)/h was reasonable to recover LFG with methane content ~58%. Considering the estimated methane production potential of 31.7 m(3) CH(4) per ton of FWL, methane recovery from the landfill was enhanced by 14%. The scientific findings of this short-term investigation indicates that FWL can be injected into the existing sanitary landfills to tackle the present issue and such landfills with efficient liner and gas collection facility can be utilized as absolute and sustainable environmental infrastructures.  相似文献   

16.
The objective of this study was to evaluate a new alternative for yard waste management by constructing, operating and monitoring a landfill-based two-stage batch digester (anaerobic/aerobic) with the recovery of energy and compost. The system was initially operated under anaerobic conditions for 366 days, after which the yard waste was aerated for an additional 191 days. Off gas generated from the aerobic stage was treated by biofilters. Net energy recovery was 84.3MWh, or 46kWh per million metric tons of wet waste (as received), and the biochemical methane potential of the treated waste decreased by 83% during the two-stage operation. The average removal efficiencies of volatile organic compounds and non-methane organic compounds in the biofilters were 96-99% and 68-99%, respectively.  相似文献   

17.
采用膜分离—变压吸附耦合工艺处理DQ催化剂载体生产过程产生的高浓度挥发性有机物(VOCs)废气。实验结果表明:在进气正己烷和非甲烷总烃的质量浓度分别为95 000~212 000 mg/m3和100 000 ~220 000 mg/m3、渗余侧压力0.25 MPa、渗透侧真空度0.09 MPa、进气流量15 Nm³/h的条件下,膜分离单元对废气中正己烷及非甲烷总烃的平均去除率分别为97.88%和97.29%;变压吸附单元对正己烷及非甲烷总烃的平均去除率分别为99.35%和99.33%;整套装置对正己烷及非甲烷总烃的平均总去除率分别为99.99%和99.98%。平均正己烷回收率达95.56%。处理后废气中非甲烷总烃质量浓度小于70 mg/ m3,达到北京市DB 11/ 447—2007 《炼油与石油化学工业大气污染物排放标准》的一级指标。  相似文献   

18.
Biogas utilized for energy production needs to be free from organic silicon compounds, as their burning has damaging effects on turbines and engines; organic silicon compounds in the form of siloxanes can be found in biogas produced from urban wastes, due to their massive industrial use in synthetic product, such as cosmetics, detergents and paints.Siloxanes removal from biogas can be carried out by various methods (Mona, 2009, Ajhar et al., 2010, Schweigkofler and Niessner, 2001); aim of the present work is to find a single practical and economic way to drastically and simultaneously reduce both the hydrogen sulphide and the siloxanes concentration to less than 1 ppm. Some commercial activated carbons previously selected (Monteleone et al., 2011) as being effective in hydrogen sulfide up taking have been tested in an adsorption measurement apparatus, by flowing the most volatile siloxane (hexamethyldisiloxane or L2) in a nitrogen stream, typically 100–200 ppm L2 over N2, through an activated carbon powder bed; the adsorption process was analyzed by varying some experimental parameters (concentration, grain size, bed height). The best activated carbon shows an adsorption capacity of 0.1 g L2 per gram of carbon. The next thermogravimetric analysis (TGA) confirms the capacity data obtained experimentally by the breakthrough curve tests.The capacity results depend on L2 concentration. A regenerative carbon process is then carried out by heating the carbon bed up to 200 °C and flushing out the adsorbed L2 samples in a nitrogen stream in a three step heating procedure up to 200 °C. The adsorption capacity is observed to degrade after cycling the samples through several adsorption–desorption cycles.  相似文献   

19.
Clay is widely used as a traditional cover material for landfills. As clay becomes increasingly costly and scarce, and it also reduces the storage capacity of landfills, alternative materials with low hydraulic conductivity are employed. In developing countries such as China, landfill gas (LFG) is usually extracted for utilization during filling stage, therefore, the intermediate covering system is an important part in a landfill. In this study, a field test of LFG extraction was implemented under the condition of using high-density polyethylene (HDPE) geomembrane layer as the only intermediate cover on the landfill. Results showed that after welding the HDPE geomembranes together to form a whole airtight layer upon a larger area of landfill, the gas flow in the general pipe increased 25% comparing with the design that the HDPE geomembranes were not welded together, which means that the gas extraction ability improved. However as the heat isolation capacity of the HDPE geomembrane layer is low, the gas generation ability of a shallow landfill is likely to be weakened in cold weather. Although using HDPE geomembrane layer as intermediate cover is acceptable in practice, the management and maintenance of it needs to be investigated in order to guarantee its effective operation for a long term.  相似文献   

20.
Sanitary landfills for Municipal Solid Waste (MSW) disposal have been identified as one of the most important anthropogenic sources of methane (CH4) emissions; in order to minimize its negative effects on the environment, landfill gas (LFG) recovery is a suitable tool to control CH4 emissions from a landfill site; further, the measurement of CH4 emissions can represent a good way to evaluate the effectiveness of LFG recovering systems. In general, LFG will escape through any faults in the landfill capping or in the LFG collection system. Indeed, some areas of the capping can be more permeable than others (e.g. portions of a side slope), especially when considering a temporarily capped zone (covered area that is not expected to receive any further waste for a period of at least 3 months, but for engineering reasons does not have a permanent cap yet). These areas, which are characterized by abnormal emissions, are usually defined as “features”: in particular, a feature is a small, discrete area or an installation where CH4 emissions significantly differ from the surrounding zones. In the present study, the influence that specific features have on CH4 emissions has been investigated, based on direct measurements carried out in different seasons by means of a flux chamber to the case study of Palermo (IT) landfill (Bellolampo). The results showed that the flux chamber method is reliable and easy to perform, and the contoured flux maps, obtained by processing the measured data were found to be a suitable tool for identifying areas with abnormal (high) emissions. Further, it was found that a relationship between methane emission rates and landfill side slope can be established. Concerning the influence of the temporary HDPE cover system on CH4 recovery efficiency, it contributed to a significant decrease of the free surface area available for uncontrolled emissions; this aspect, coupled to the increase of the CH4 volumes collected by the LFG recovery system, led to a significant increase of the recovery efficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏