首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this study was to determine whether the fear of dioxin/furan emissions from waste-to-energy plants was justified by the 2007 status of emissions of French municipal solid waste incinerators (MSWIs). All emissions were examined, plant by plant, but this paper focuses on the incinerator emission that is most frequently mentioned in the French media, toxic dioxins and furans. The study showed that there are 85 large MSWI that generate electricity or heat, i.e., waste-to-energy (WTE) plants, and 39 smaller MSW incinerators. The results showed that all French MSWI are operated well below the EU and French standard of 0.1 ng TEQ Nm?3 (toxic equivalent nanograms per standard cubic meter) and that their total dioxin/furan emissions decreased from 435 g TEQ in 1997 to only 1.2 g in 2008. All other industrial emissions of dioxins have also decreased and the major source is residential combustion of wood (320 g TEQ). It was extremely difficult to obtain MSWI emission data. This unwarranted lack of transparency has resulted in the public perception that MSWI plants are major contributors to dioxin emissions while in fact they have ceased to be so.  相似文献   

2.
Municipal solid waste incinerators every year produce tons of fly ashes which, differently from coal fly ashes, contain large amounts of toxic substances (heavy metals, dioxins, furans). The stabilization/solidification (S/S) technology known as geopolymerization is proposed with the purpose to bond physically and chemically incinerator fly ashes (IFA) in a solid matrix, in order to reduce pollutant mobility. The chemical stability of geopolymers with Si/Al ratio of 1.8–1.9 and Na/Al ratio of 1.0, synthesized by alkali activation of metakaolin and the addition of 20 wt% of two different kinds of IFA, is presented. The concentration of the alkaline solution, water to solid ratio and curing process have been optimized. The room temperature consolidation of IFA containing geopolymers has been tested for leachability in water for 1 day, accordingly to EN 12457 regulation and extended to 7 days to increase the water attack on solid granules. Leachable metals in the test solution, determined by ICP_AES, fall within limit values set by regulation for non-dangerous waste landfill disposal. Geopolymeric matrix evolution with leaching time has been also evaluated in terms of pH and electrical conductivity increase in solution.  相似文献   

3.
Sulfur recirculation is a new technology for reducing boiler corrosion and dioxin formation. It was demonstrated in full-scale tests at a Waste to Energy plant in Göteborg (Sweden) during nearly two months of operation. Sulfur was recirculated as sulfuric acid from the flue gas cleaning back to the boiler, thus creating a sulfur loop.The new technology was evaluated by extensive measurement campaigns during operation under normal conditions (reference case) and operation with sulfur recirculation. The chlorine content of both fly ash and boiler ash decreased and the sulfur content increased during the sulfur recirculation tests. The deposit growth and the particle concentration decreased with sulfur recirculation and the dioxin concentration (I-TEQ) of the flue gas was reduced by approximately 25%. Sulfuric acid dew point measurements showed that the sulfuric acid dosage did not lead to elevated SO3 concentrations, which may otherwise induce low temperature corrosion.In the sulfur recirculation corrosion probe exposures, the corrosion rate decreased for all tested materials (16Mo3, Sanicro 28 and Inconel 625) and material temperatures (450 °C and 525 °C) compared to the reference exposure. The corrosion rates were reduced by 60–90%. Sulfur recirculation prevented the formation of transition metal chlorides at the metal/oxide interface, formation of chromate and reduced the presence of zinc in the corrosion products. Furthermore, measured corrosion rates at 525 °C with sulfur recirculation in operation were similar or lower compared to those measured at 450 °C material temperature in reference conditions, which corresponds to normal operation at normal steam temperatures. This implies that sulfur recirculation allows for higher steam data and electricity production without increasing corrosion.  相似文献   

4.
Biogas or landfill gas can be converted to a high-grade gas rich in methane with the use of municipal solid waste incineration bottom ash as a reactant for fixation of CO2 and H2S. In order to verify results previously obtained at a laboratory scale with 65–90 kg of bottom ash (BA), several test runs were performed at a pilot scale, using 500–1000 kg of bottom ash and up to 9.2 N m3/h real landfill gas from a landfill in the Tuscany region (Italy). The input flow rate was altered. The best process performance was observed at a input flow rate of 3.7 N m3/(h tBA). At this flow rate, the removal efficiencies for H2S were approximately 99.5–99%.  相似文献   

5.
A process model of municipal solid waste incinerators (MSWIs) and new technologies for metal recovery from combustion residues was developed. The environmental impact is modeled as a function of waste composition as well as waste treatment and material recovery technologies. The model includes combustion with a grate incinerator, several flue gas treatment technologies, electricity and steam production from waste heat recovery, metal recovery from slag and fly ash, and landfilling of residues and can be tailored to specific plants and sites (software tools can be downloaded free of charge). Application of the model to Switzerland shows that the treatment of one tonne of municipal solid waste results on average in 425 kg CO2-eq. generated in the incineration process, and 54 kg CO2-eq. accrue in upstream processes such as waste transport and the production of operating materials. Downstream processes, i.e. residue disposal, generates 5 kg CO2-eq. Savings from energy recovery are in the range of 67 to 752 kg CO2-eq. depending on the assumptions regarding the substituted energy production, while the recovery of metals from slag and fly ash currently results in a net saving of approximately 35 kg CO2-eq. A similar impact pattern is observed when assessing the MSWI model for aggregated environmental impacts (ReCiPe) and for non-renewable resource consumption (cumulative exergy demand), except that direct emissions have less and no relevance, respectively, on the total score. The study illustrates that MSWI plants can be an important element of industrial ecology as they provide waste disposal services and can help to close material and energetic cycles.  相似文献   

6.
This paper described the findings and data resulting from the German National Dioxin Measurement Programme at 11 plants with 15 incineration units. The programme's main focus was to provide answers to the question of the causes of dioxins and furans formation in the plant and to look for ways to reduce dioxin and furan emissions, including waste management measures and technical measures taken inside the plants. The investigations confirmed the finding that a major proportion of the dioxin and furan emissions is due to de novo synthesis. Two areas have to be mentioned here, the cooling zone behind the combustion chamber and the dust removal system.Significant differences in dioxin and furan concentration levels were ascertained between variations of operating parameters, e.g. much air, little air, extremely unfavourable operating conditions (i.e. start-up and shut-down without auxiliary burners) and the normal operating conditions specific to a plant. To comply the limit value of 0.1 ng I-TE m−3 it is necessary that conventional thermal treatment plants take additional measures to remove dioxins and furans from the flue gas. The measurements were carried out from 1985 to 1990. In addition, samples of fractions of household waste were analysed for their dioxins and furans.  相似文献   

7.
Surrogate measurements should be low in cost and quick to perform. To examine its feasibility, continuous surrogate monitoring was performed using an organic halogen compound (OHC) analyzer. Surrogates for dioxins (DXNs) from waste incinerators were examined by changing the operating conditions such as the atomized volume of activated carbon added and the temperature at the inlet of the dust collector. OHCs were measured along with DXNs in flue gas at the inlet and the outlet of the dust collector of two waste incinerators over five runs; the fly ash was sampled at the same time. Although the final flue gas concentration of DXNs at the incineration plants was below the regulation criteria, this does not mean complete reduction of DXNs. In addition, the de novo synthesis of DXNs inside the dust collectors was studied by analyzing the mass balance for DXNs concentrations in flue gas and fly ash. Semivolatile chlorinated organic compound concentrations at the outlet of the bag filter were basically well correlated with DXNs levels at the inlet of the bag filter in the test runs. When advanced flue gas treatment is applied by using a bag filter and lime/activated carbon adsorbent, DXNs that may be generated during flue gas cooling processes move to the fly ash, and this amount determines the mass balance of the entire system. It may be useful to monitor surrogate organic halogens for detecting changes in DXN concentrations of both flue gas and fly ash in incineration plants.  相似文献   

8.
The rising popularity of incineration of municipal solid waste (MSW) calls for detailed mathematical modeling and accurate prediction of pollutant emissions. In this paper, mathematical modeling methods for both solid and gaseous phases were employed to simulate the operation of a 450 t/d MSW-burning incinerator to obtain detailed information on the flow and combustion characteristics in the furnace and to predict the amount of pollutant emissions. The predicted data were compared to on-site measurements of gas temperature, gas composition and SNCR de-NOX system. The major operating conditions considered in this paper were grate speed and oxygen concentration. A suitable grate speed ensures complete waste combustion. The predictions are as follows: volatile release increases with increasing grate speed, and the maximal value is within the range of 700–800 kg/m2 h; slow grate speeds result in incomplete combustion of fixed carbon; the gas temperature at slow grate speeds is higher due to adequate oxygenation for fixed carbon combustion, and the deviation reaches 200 K; NOX emission decreases, but CO emission and O2 concentrations increase, and the deviation is 63%, 34% and 35%, respectively. Oxygen-enriched atmospheres promote the destruction of most pollutants due to the high oxygen partial pressure and temperature. The furnace temperature, NO production and CO emission increase as the oxygen concentration increases, and the deviation of furnace exit temperature, NO and CO concentration is 38.26%, 58.43% and 86.67%, respectively. Finally, oxygen concentration is limited to below 35% to prevent excessive CO and NOX emission without compromising plant performance. The current work greatly helps to understand the operating characteristics of large-scale MSW-burning plants.  相似文献   

9.
Using a dual species methane/acetylene instrument based on cavity ring down spectroscopy (CRDS), the dynamic plume tracer dispersion method for quantifying the emission rate of methane was successfully tested in four measurement campaigns: (1) controlled methane and trace gas release with different trace gas configurations, (2) landfill with unknown emission source locations, (3) landfill with closely located emission sources, and (4) comparing with an Fourier transform infrared spectroscopy (FTIR) instrument using multiple trace gasses for source separation. The new real-time, high precision instrument can measure methane plumes more than 1.2 km away from small sources (about 5 kg h?1) in urban areas with a measurement frequency allowing plume crossing at normal driving speed. The method can be used for quantification of total methane emissions from diffuse area sources down to 1 kg per hour and can be used to quantify individual sources with the right choice of wind direction and road distance. The placement of the trace gas is important for obtaining correct quantification and uncertainty of up to 36% can be incurred when the trace gas is not co-located with the methane source. Measurements made at greater distances are less sensitive to errors in trace gas placement and model calculations showed an uncertainty of less than 5% in both urban and open-country for placing the trace gas 100 m from the source, when measurements were done more than 3 km away. Using the ratio of the integrated plume concentrations of tracer gas and methane gives the most reliable results for measurements at various distances to the source, compared to the ratio of the highest concentration in the plume, the direct concentration ratio and using a Gaussian plume model. Under suitable weather and road conditions, the CRDS system can quantify the emission from different sources located close to each other using only one kind of trace gas due to the high time resolution, while the FTIR system can measure multiple trace gasses but with a lower time resolution.  相似文献   

10.
An integrated risk assessment study has been performed in an area within 5 km from a landfill that accepts non hazardous waste. The risk assessment was based on measured emissions and maximum chronic population exposure, for both children and adults, to contaminated air, some foods and soil. The toxic effects assessed were limited to the main known carcinogenic compounds emitted from landfills coming both from landfill gas torch combustion (e.g., dioxins, furans and polycyclic aromatic hydrocarbons, PAHs) and from diffusive emissions (vinyl chloride monomer, VCM). Risk assessment has been performed both for carcinogenic and non-carcinogenic effects. Results indicate that cancer and non-cancer effects risk (hazard index, HI) are largely below the values accepted from the main international agencies (e.g., WHO, US EPA) and national legislation (D.Lgs. 152/2006 and D.Lgs. 4/2008).  相似文献   

11.
This paper describes the experimental study of dioxins removal from flue gas from a co-combustion municipal solid waste and coal incinerator by means of a fluidized absorption tower and a fabric filter. A test rig has been set up. The flow rate of flue gas of the test rig is 150-2000 m3/h. The system was composed of a humidification and cooling system, an absorption tower, a demister, a slurry make-up tank, a desilter, a fabric filter and a measurement system. The total height of the absorption tower was 6.5m, and the diameter of the reactor pool was 1.2 m. When the absorbent was 1% limestone slurry, the recirculation ratio was 3, the jet rate was 5-15 m/s and the submerged depth of the bubbling pipe under the slurry was 0.14 m, the removal efficiency for dioxins was 99.35%. The concentration of dioxins in the treated flue gas was 0.1573 x 10(-13)kg/Nm3 and the concentration of oxygen was 11%. This concentration is comparable to the emission standards of other developed countries.  相似文献   

12.
A utilization way of herb residues is designed to convert herb residues to gas fuel in industrial-scale by a circulating fluidized bed gasifier in this paper. The product gas is used in the production of Chinese medicine, and the heat of the flue gas from the boiler can be used in herb residues drying to realize the energy recycling and no herb residues discharge. The gasification characteristics of herb residues in the circulating fluidized bed of 300 kg/h were investigated for about 200 h. The results indicated that the gas composition and tar yield were affected by biomass flow rate, equivalence ratio (ER), moisture content and char circulating. The lower heating value of product gas was 4–5 MJ/m3 using herb residues as feedstock. When mean biomass flow rate was at 5.5 kg m?2 s?1 and ER at 0.35, the product gas reached a good condition with lower heating value of 4.89 MJ/m3 and cold gas efficiency of 62.36%. When the moisture content changed from 12.5% to 18.7%, the concentrations of H2, CO and CO2 changed from 4.66% to 6.92%, 11.23% to 10.15%, and 16.55% to 17.82% respectively, and the tar content in gas decreased from 15.1 g/m3 to 14.4 g/m3 when the moisture content increased from 12.5% to 15.4%. There are metal oxides in the ash of herb residues, especially CaO, MgO, K2O, Al2O3, and Fe2O3 which have obvious function on tar catalytic decomposition. The ash that attaches to the char particles can decrease the tar yield and improve the quality of gas after returning to the gasifier.  相似文献   

13.
Dioxins like polychlorinated dibenzo-p-dioxins (PCSDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) are mainly emitted from waste incinerators (WIs) and have become an international research focus because of its serious concerns over the adverse health effects. The detoxification of PCCDs/Fs and PCBs is very difficult because of their stable chemical structure. A significant hydrodechlorination/detoxification of polychlorinated 1-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) were achieved in fly ash by using an aqueous mixture of calcium hydroxide and sulfur. Two different fly ashes were studied: originating from municipal waste incinerator (FA1) and industrial waste incinerator (FA2). They were heated with the aqueous mixture at 150 °C for 30 or 60 min with agitation. Higher decomposition (87%) and detoxification (87.7%) of PCDD/Fs and PCBs were achieved at 150 °C with two runs; every run was for 30 min, compared to one run for 60 min. FA2 gave higher decomposition and detoxification as compared to FA1, which might be due to higher metal content that played a catalytic role to decompose and detoxify the PCDDs, PCDFs and PCBs. The decomposition and detoxification of PCDFs in fly ash was higher than PCDDs and was augmented with increasing number of chlorides on aromatic compounds. As the highly significant decomposition and detoxification of higher concentration of PCDD/Fs and PCBs were achieved in 1 hour without additive catalyst and at low temperature of 150 °C, therefore, the developed method is cost effective and most suitable to apply on commercial/industrial level. The detail results of hydrodechlorination/detoxification of PCDD, PCDFs at different conditions are described and its mechanism is discussed.  相似文献   

14.
Greenhouse gas (GHG) emission factors are used with increased frequency for the accounting and reporting of GHG from waste management. However, these factors have been calculated for developed countries of the Northern Hemisphere and are lacking for developing countries. This paper shows how such factors have been developed for the collection, transport and landfilling of municipal waste in South Africa. As such it presents a model on how international results and methodology can be adapted and used to calculate country-specific GHG emission factors from waste. For the collection and transport of municipal waste in South Africa, the average diesel consumption is around 5 dm3 (litres) per tonne of wet waste and the associated GHG emissions are about 15 kg CO2 equivalents (CO2 e). Depending on the type of landfill, the GHG emissions from the landfilling of waste have been calculated to range from ?145 to 1016 kg CO2 e per tonne of wet waste, when taking into account carbon storage, and from 441 to 2532 kg CO2 e per tonne of wet waste, when carbon storage is left out. The highest emission factor per unit of wet waste is for landfill sites without landfill gas collection and these are the dominant waste disposal facilities in South Africa. However, cash strapped municipalities in Africa and the developing world will not be able to significantly upgrade these sites and reduce their GHG burdens if there is no equivalent replacement of the Clean Development Mechanism (CDM) resulting from the Kyoto agreement. Other low cost avenues need to be investigated to suit local conditions, in particular landfill covers which enhance methane oxidation.  相似文献   

15.
This study was performed to suggest the improvements through measuring the amounts of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), re-synthesized in peripheral utilities (PUs) of a commercial-scale municipal solid waste incineration facility (MSWIF) where a few research results existed. The PUs examined in this study consisted of air pre-heaters (APHs) and gas/gas re-heater (GGRH) and kerosene-fired duct burner for selective catalytic reduction (SCR) process. PCDDs/PCDFs in flue gas were simultaneously measured at the inlet and outlet of PUs.Flue gas was cooled down from 380 °C to 249 °C by exchanging the heat with fresh air in APHs, and then heated up to 383 °C by GGRH and duct burner from 164 °C at the outlet of bag filter. The results showed that PCDDs/PCDFs were 3–4 times higher within this temperature range of PUs. In comparison of PCDDs/PCDFs concentrations at the inlet with those at the outlet of PUs, particulate-phase PCDDs/PCDFs were about 9.5–10 times enriched while gaseous-phase ones were decreased by about 33–41%. The PCDDs/PCDFs re-synthesized in the PUs, where PCDDs were relatively higher than PCDFs, showed somewhat different patterns compared to those formed at incinerators and emitted at stack. Through the investigations for PUs, we conclude that the PUs used in MSWIFs was a potential source for de novo synthesis of PCDDs/PCDFs.  相似文献   

16.
氯苯类生产过程POPs污染风险点分析及环境管理建议   总被引:1,自引:0,他引:1       下载免费PDF全文
我国氯苯类生产过程中的二噁英类、五氯苯、六氯苯等非故意产生类持久性有机污染物对环境具有潜在风险。对具有典型工艺特征的氯苯类生产过程中关键节点的二噁英类进行了检测和分析,在残渣、残液、废水和副产品(多氯苯混合物)中发现高浓度二噁英类,主要成分为多氯代二苯并呋喃,推测可能与原料中呋喃类杂质有关。为践行我国《关于持久性有机污染物的斯德哥尔摩公约》的履约责任和控制二噁英类排放造成的环境风险,结合国内外相关管理制度提出了法规制度、监督管理、工艺改进、产品质控和废物处置等方面的环境管理建议。  相似文献   

17.
In the present study, we investigated the effects of two bulking materials, Sphagnum peat and pine wood chips, on the early stages of biowaste composting in two pilot-scale processes. Emphasis was placed on studying the formation conditions of malodorous compost gases in the initial phases of the processes. The results showed that gas emission leaving an open windrow and a closed drum composting system contained elevated concentrations of fermentative microbial metabolites when acid Sphagnum peat (pH 3.2) was used as a bulking material. Moreover, the gas emission of the peat amended drum composter contained a high concentration of odour (up to 450,000 ou m?3 of air). The highest odour values in the outlet gas of peat amended composts coincided with the elevated concentrations of volatile organic compounds such as acetoin and buthanedion. We conclude that the acidifying qualities of composting substrates or bulking material may intensify odour emission from biowaste composts and prolong the early stages of the composting process.  相似文献   

18.
Swine manure was subjected to laboratory scale composting in order to quantify bioaerosols, i.e., airborne culturable bacteria and endotoxin, in the exhaust gas, which provided details on the effect of temperature on bacterial emissions. The concentration of airborne bacteria reached 31,250 colony-forming units (CFU)/m3 during the thermophilic stage of composting, and positively correlated with the temperature profile of the compost pile. Initially, the endotoxin concentration was 1820 endotoxin units (EU)/m3, but it decreased exponentially as the composting process proceeded. The temperature can be an excellent indicator of bacterial emissions during the composting process, indicating that the composting process requires a consistently high temperature to ensure sanitization of both compost and bacterial emissions. The cumulative emission data showed that emission factors was 11.2?13.5 CFU/g dry swine manure and that of endotoxin was 0.5?0.9 EU/g dry swine manure. The bacterial diversity in the bioaerosol was analyzed by polymerase chain reaction-denaturing gradient gel electrophoresis, revealing the presence of various gram-negative bacterial consortia.  相似文献   

19.
In this study biogas and high quality digestate were recovered from winery waste (wine lees) through anaerobic co-digestion with waste activated sludge both in mesophilic and thermophilic conditions. The two conditions studied showed similar yields (0.40 m3/kgCODfed) but different biological process stability: in fact the mesophilic process was clearly more stable than the thermophilic one in terms of bioprocess parameters.The resulting digestates showed good characteristics for both the tested conditions: heavy metals, dioxins (PCDD/F), and dioxin like bi-phenyls (PCBs) were concentred in the effluent if compared with the influent because of the important reduction of the solid dry matter, but remained at levels acceptable for agricultural reuse. Pathogens in digestate decreased. Best reductions were observed in thermophilic condition, while at 37 °C the concentration of Escherichia coli was at concentrations level as high as 1000 UFC/g. Dewatering properties of digestates were evaluated by means of the capillary suction time (CST) and specific resistance to filtration (SRF) tests and it was found that a good dewatering level was achievable only when high doses of polymer (more than 25 g per kg dry solids) were added to sludge.  相似文献   

20.
This paper describes a method developed for quantification of gas emissions from the leachate collection system at landfills and present emission data measured at two Danish landfills with no landfill gas collection systems in place: Fakse landfill and AV Miljø. Landfill top covers are often designed to prevent infiltration of water and thus are made from low permeable materials. At such sites a large part of the gas will often emit through other pathways such as the leachate collection system. These point releases of gaseous constituents from these locations cannot be measured using traditional flux chambers, which are often used to measure gas emissions from landfills. Comparing tracer measurements of methane (CH4) emissions from leachate systems at Fakse landfill and AV Miljø to measurements of total CH4 emissions, it was found that approximately 47% (351 kg CH4 d?1) and 27% (211 kg CH4 d?1), respectively, of the CH4 emitting from the sites occurred from the leachate collection systems. Emission rates observed from individual leachate collection wells at the two landfills ranged from 0.1 to 76 kg CH4 d?1. A strong influence on emission rates caused by rise and fall in atmospheric pressure was observed when continuously measuring emission from a leachate well over a week. Emission of CH4 was one to two orders of magnitude higher during periods of decreasing pressure compared to periods of increasing pressure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号