首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
针对室内空气中颗粒状污染物流动特性的测量搭建了PTV测量系统,该系统由白光照明、CCD摄像头采集图像及四轨迹像点匹配算法软件构成.测量结果表明,该PTV系统具有测量室内空气中可吸入颗粒扩散与流动的速度分布、浓度分布等特性.  相似文献   

2.
The aim of this study was to compare the personal exposure to particles and bioaerosols with that measured by stationary samplers in the main microenvironments, i.e., the home and the workplace. A random sample of 81 elementary school teachers was selected from the 823 teachers working for two councils in eastern Finland for the winter time measurement period. Bioaerosol and other particles were collected on filters by button samplers using personal sampling and microenvironmental measurements in homes and workplaces. The 24-hour sampling period was repeated twice for each teacher. Particle mass, absorption coefficient of the filter and the concentration of viable and total microorganisms were analyzed from each filter. In this paper, the study design, quality assurance principles and results of particle and bioaerosol exposure are described. The results show that particle mass concentrations, absorption coefficient and fungi were higher in personal exposure samples than in home and workplace samples. Furthermore, these concentrations were usually lower in the home than in the workplace. Bacterial concentrations were highest in heavily populated workplaces, while the viable fungi concentrations were lowest in workplaces. The fungi and bacteria results showed high variation, which emphasises the importance of quality assurance (duplicates and field blanks) in the microbial field measurements. Our results indicate that personal exposure measurements of bioaerosols in indoor environments are feasible and supplement the information obtained by stationary samplers.  相似文献   

3.
An investigation of the relationship between observed nickel aerosol exposures and urinary nickel excretion was undertaken at a Scandinavian nickel refinery. The goal of the study was to assess the impact of nickel aerosol speciation, the use of particle size-selective sampling instrumentation and adjustment of urinary levels for creatinine excretion on the usefulness of urinary nickel excretion as a marker for exposure. Urinary nickel measurements and paired 'total' and inhalable aerosol exposure measurements were collected each day for one week from refinery workers in four process areas. The mean observed urinary nickel concentration was 12 micrograms L-1 (11 micrograms of Ni per g of creatinine). The strongest relationships between urinary excretion and aerosol exposure were found when urinary nickel levels were adjusted for creatinine excretion and when exposure to only soluble forms of nickel aerosol was considered. No significant difference was observed between measures of 'total' and inhalable aerosol in the ability to predict urinary excretion patterns. In the light of these results, it is recommended that consideration be given to the chemical species distribution of nickel aerosol in the use of urinary nickel measurements as a screening tool for cancer risk in occupationally-exposed populations.  相似文献   

4.
Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.  相似文献   

5.
The Respicon has been introduced as a sampler for health related measurements of airborne contaminants at workplaces. The instrument is aimed at simultaneous collection of three health related aerosol fractions: (a) the coarser inhalable fraction, defining the aerosol fraction that may enter the nose and mouth during breathing; (b) the intermediate thoracic fraction, defining the fraction that may penetrate beyond the larynx and so reach the lung; and (c) the finer respirable fraction, defining the fraction that may penetrate to gas exchange region of the lung. The instrument has a number of features attractive to occupational hygienists: in addition to providing the three aerosol fractions simultaneously, it is light and compact enough to be used as a personal sampler. yet can be a tripod mounted for area sampling, it can provide samples not only for gravimetric analysis but also microscopic and chemical analyses; and it is also available in a photometric direct-reading version. The instrument has previously been evaluated as an area sampler and, in this mode of operation, has shown reasonable accuracy in collecting respirable, thoracic and inhalable particles, the latter up to particle diameters of ca. 80 microm. Except for some scattered unpublished data there exist no systematic investigations in the Respicon's performance when used as a personal sampler in the industrial environment. In this paper, we will report on a study of side by side comparison of the Respicon with the IOM inhalable sampler, regarded as a reference instrument for the inhalable fraction. The main study was performed at six different workplaces in a nickel refinery. Statistical analysis of the gravimetrically-determined concentration data reveals consistently lower aerosol exposure values for the Respicon as compared to the IOM sampler. The data for the nickel workplaces are compared with findings from other studies. The results are interpreted in the light of the overall results and the possibility of introducing a correction factor is discussed.  相似文献   

6.
An experimental system was developed for the rapid measurement of the aspiration/transfer efficiency of aerosol samplers in a wind tunnel. We attempted to measure the aspiration and particle transfer characteristics of two inlets commonly used for sampling airborne Particulate Matter (PM): the 'Total Suspended Particulate' or TSP inlet, and the louvered 'dichotomous sampler inlet' typically used in sampling PM10 or PM2.5. We were able to determine the fraction of the external aerosol that enters the inlet and is transferred through it, and hence is available for collection by a filter, or further size fractionation into PM10 or PM2.5. This 'sampling efficiency' was analysed as a function of dimensionless aerodynamic parameters in order to understand the factors governing inlet performance. We found that for the louvered inlet the sampling efficiency increases as the external wind increases. Under all conditions expected in practical use the louvered inlet aspirates sufficient PM to allow either PM10 or PM2.5 to be selected downstream. The TSP inlet's sampling efficiency decreases with increasing external wind, and the TSP inlet is likely to under-sample the coarse end of the PM10 fraction at moderate and high external winds. As this inlet is generally not used with a downstream size fractionator, changes in sampling efficiency directly affect the measured aerosol concentration. We also investigated whether it is possible to dimensionally scale the PM inlets to operate at either higher or lower flow rates, while preserving the same sampling characteristics as the current full-scale, 16.67 L min(-1) versions. In the case of the louvered inlet, our results indicate that scaling to lower flow rates is possible; scaling to higher flow rates was not tested. For the TSP sampler, the sampling efficiency changes if the sampler is scaled to operate at smaller or larger flow rates, leading to unreliable performance.  相似文献   

7.
Until 2009, the limit values for airborne sulfuric acid in Europe were based on the inhalable particle fraction (e.g. MAK (Maximum allowed concentration at workplace) value 0.1 mg m(-3) as the inhalable fraction). With the publication of the Commission Directive 2009/161/EU, an Indicative Occupational Exposure Limit Value (IOELV) of 0.05 mg m(-3) for sulfuric acid aerosols was based for the first time on the thoracic particle fraction. To permit a comparison of the measured values for the inhalable fraction with those of the thoracic fraction and to quantify the thoracic fraction, a cyclone was fabricated out of sulfuric-acid-resistant stainless steel that achieves suitable collection characteristics (PM(10)) at a flow rate of 5.34 L min(-1). 49 measurements were carried out in parallel in 21 companies. At concentrations well below the IOELV, there is little difference between the thoracic and inhalable particle concentrations. At higher concentrations (>0.1 mg m(-3) inhalable aerosol), larger droplets have a marked effect on the measured values and the thoracic fraction accounts for only 32.1 ± 12.5% of the inhalable fraction. The EU's IOELV and the proposal of the MAK Commission therefore provide a comparable level of protection. In the transposition of the IOELV into national law, an air limit of 0.1 mg m(-3) could therefore be implemented for the inhalable fraction.  相似文献   

8.
In the absence of methods for determining particle size distributions in the inhalable size range with good discrimination, the samples collected by personal air sampling devices can only be characterized by their total mass. This parameter gives no information regarding the size distribution of the aerosol or the size-selection characteristics of different samplers in field use conditions. A method is described where the particles collected by a sampler are removed, suspended, and re-deposited on a mixed cellulose-ester filter, and examined by optical microscopy to determine particle aerodynamic diameters. This method is particularly appropriate to wood dust particles which are generally large and close to rectangular prisms in shape. Over 200 wood dust samples have been collected in three different wood-products industries, using the traditional closed-face polystyrene/acrylonitrile cassette, the Institute of Occupational Medicine inhalable sampler, and the Button sampler developed by the University of Cincinnati. A portion of these samples has been analyzed to determine the limitations of this method. Extensive quality control measures are being developed to improve the robustness of the procedure, and preliminary results suggest the method has an accuracy similar to that required of National Institute for Occupational Safety and Health (NIOSH) methods. The results should provide valuable insights into the collection characteristics of the samplers and the impact of these characteristics on comparison of sampler results to present and potential future limit values. The NIOSH Deep South Education and Research Center has a focus on research into hazards of the forestry and associated wood-products industry, and it is hoped to expand this activity in the future.  相似文献   

9.
Ambient aerosol concentrations along the roadside of metropolitan cities of Pakistan were measured using a Grimm 1.109 dust monitor. Considering the high ambient aerosol concentrations, regional lung deposition of aerosol particles in the human respiratory tract was calculated to assess extent of exposure. Lung deposition was computed in terms of mass concentration and the associated surface area for 12 male traffic wardens using the latest version of the stochastic lung deposition code Inhalation, Deposition, and Exhalation of Aerosols in the Lung. The results have revealed 4 to 10 times higher concentrations than recommended by WHO guidelines. The deposition results derived from the model disclose that extrathoracic deposition is in the range of 22 to 28 % with total lung deposition ranging from 40 to 44 % for the scanned particle window of 0.25–10 μm. Considering an average 8-h shift per day and an average breathing rate of 1.3 m3?h?1, it is approximated that in a worker, up to 1.6 mg of inhalable particle mass can deposit per day.  相似文献   

10.
The use of hydrated magnesium carbonate hydroxide (magnesia alba) for drying the hands is a strong source for particulate matter in indoor climbing halls. Particle mass concentrations (PM10, PM2.5 and PM1) were measured with an optical particle counter in 9 indoor climbing halls and in 5 sports halls. Mean values for PM10 in indoor climbing halls are generally on the order of 200-500 microg m(-3). For periods of high activity, which last for several hours, PM10 values between 1000 and 4000 microg m(-3) were observed. PM(2.5) is on the order of 30-100 microg m(-3) and reaches values up to 500 microg m(-3), if many users are present. In sports halls, the mass concentrations are usually much lower (PM10 < 100 microg m(-3), PM2.5 < or = 20 microg m(-3)). However, for apparatus gymnastics (a sport in which magnesia alba is also used) similar dust concentrations as for indoor climbing were observed. The size distribution and the total particle number concentration (3.7 nm-10 microm electrical mobility diameter) were determined in one climbing hall by an electrical aerosol spectrometer. The highest number concentrations were between 8000 and 12 000 cm(-3), indicating that the use of magnesia alba is no strong source for ultrafine particles. Scanning electron microscopy and energy-dispersive X-ray microanalysis revealed that virtually all particles are hydrated magnesium carbonate hydroxide. In-situ experiments in an environmental scanning electron microscope showed that the particles do not dissolve at relative humidities up to 100%. Thus, it is concluded that solid particles of magnesia alba are airborne and have the potential to deposit in the human respiratory tract. The particle mass concentrations in indoor climbing halls are much higher than those reported for schools and reach, in many cases, levels which are observed for industrial occupations. The observed dust concentrations are below the current occupational exposure limits in Germany of 3 and 10 mg m(-3) for respirable and inhalable dust. However, the dust concentrations exceed the German guide lines for work places without use of hazardous substances. In addition, minimizing dust concentrations to technologically feasible values is required by the current German legislation. Therefore, substantial reduction of the dust concentration is required.  相似文献   

11.
Bioaerosol sampling by a personal rotating cup sampler CIP 10-M   总被引:1,自引:0,他引:1  
High concentrations of bioaerosols containing bacterial, fungal and biotoxinic matter are encountered in many workplaces, e.g. solid waste treatment plants, waste water treatment plants and sewage networks. A personal bioaerosol sampler, the CIP 10-M (M-microbiologic), has been developed to measure worker exposure to airborne biological agents. This sampler is battery operated; it is light and easy to wear and offers full work shift autonomy. It can sample much higher concentrations than biological impactors and limits the mechanical stress on the microorganisms. Biological particles are collected in 2 ml of liquid medium inside a rotating cup fitted with radial vanes to maintain an air flow rate of 10 l min(-1) at a rotational speed of approximately 7,000 rpm. The rotating cup is made of sterilisable material. The sampled particles follow a helicoidal trajectory as they are pushed to the surface of the liquid by centrifugal force, which creates a thin vertical liquid layer. Sterile water or another collecting liquid can be used. Three particle size selectors allow health-related aerosol fractions to be sampled according to international conventions. The sampled microbiological particles can be easily recovered for counting, incubation or further biochemical analysis, e.g., for airborne endotoxins. Its physical sampling efficiency was laboratory tested and field trials were carried out in industrial waste management conditions. The results indicate satisfactory collection efficiency, whilst experimental application has demonstrated the usefulness of the CIP 10-M personal sampler for individual bioaerosol exposure monitoring.  相似文献   

12.
An understanding of the scaling laws governing aerosol sampler performance leads to new options for testing aerosol samplers at small scale in a small laboratory wind tunnel. Two methods are described in this paper. The first involves an extension of what is referred to as the "conventional" approach, in which scaled aerosol sampler systems are tested in a small wind tunnel while exposed to relatively monodisperse aerosols. Such aerosols are collected by test and reference samplers respectively and assessed gravimetrically. The new studies were carried out for a modified, low flowrate version of the IOM personal inhalable aerosol sampler. It was shown that such experiments can be carried out with a very high level of repeatability, and this supported the general validity of the aerosol sampler scaling laws. The second method involves a novel testing system and protocol for evaluating the performances of aerosol samplers. Here, scaled aerosol samplers of interest are exposed to polydisperse aerosols, again in a small wind tunnel. In this instance, the sampled particles are counted and sized using a direct-reading aerodynamic particle sizer (the APS). A prototype automated aerosol sampler testing system based on this approach was built and evaluated in preliminary experiments to determine the performance of another modified version of the IOM personal inhalable aerosol sampler. The design of the new test system accounts for the complex fluid mechanical coupling that occurs near the sampler inlet involving the transition between the external flow outside the sampler and the internal airflow inside the sampler, leading in turn to uncontrolled particle losses. The problem was overcome by the insertion of porous plastic foam plugs. where the penetration characteristics are well understood, into the entries of both the test and the reference samplers. Preliminary experiments with this new system also supported the general validity of the aerosol sampler scaling laws. In addition, they demonstrated high potential that this approach may be applied in a standardised aerosol testing method and protocol.  相似文献   

13.
Atmospheric aerosols were collected during the scientific expedition to Mt. Qomolangma (Everest) in May–June, 2005. The elemental concentrations of the aerosols were determined by inductively coupled plasma mass spectrometry. This yielded data for the concentration of 14 elements: Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, and Pb. The mean elemental concentrations were generally comparable with those from central Asia and the Arctic, while much higher than those from Antarctic. Size, morphology, and chemical composition of 900 individual aerosol particles were determined by scanning electron microscopy and energy-dispersive X-ray microanalysis. Based on morphology and elemental composition, the particles were clustered into eight groups: soot (8%), tar ball (3%), alumosilicates/silica (55%), calcium sulfate (16%), Ca/Mg carbonate (2%), Fe/Ti-rich particles (3%), Pb-rich particles (1%), and biological particles (12%). The sampling site, located at 6,520 m in the Himalayas, is particularly remote and located at high altitude. Nonetheless, high aerosol enrichment factors for copper, chromium, lead, nickel, vanadium, and zinc all suggest the influence of long-range transported pollution, while enrichment in calcium and the presence of alumino-silicates in individual particle analyses indicates a distinct mineral dust influence. The backward air mass trajectories showed that the northwestern part of India may contribute to the atmospheric aerosol in the central high Himalayas.  相似文献   

14.
为了解可吸入颗粒物污染水平与气象因素之间的关系,从2008年9月—2010年2月采集乌鲁木齐市可吸入颗粒物样品,并对其随时间的变化特征及其与气象因素之间的相关性进行了统计分析。结果表明,采样时间内可吸入颗粒物中PM2.5和PM2.5-10的质量浓度的范围分别为38.2~468.7μg/m3和20.8~243.1μg/m3,平均浓度分别为134.2μg/m3和69.2μg/m3。可吸入颗粒物同时受几种气象因素的影响,其浓度与温度、能见度、风速呈负相关,与湿度呈正相关。  相似文献   

15.
Real-time particle sizers provide rapid information about atmospheric particles, particularly peak exposures, which may be important in the development of adverse health outcomes. However, these instruments are subject to erroneous readings in high-humidity environments when compared with measurements from filter-based, federal reference method (FRM) samplers. Laboratory tests were conducted to evaluate the ability of three inlet conditioners to dry aerosol prior to entering a real-time particle sizer for measuring coarse aerosols (Model 3321 Aerodynamic Particle Sizer, APS) under simulated highly humid conditions. Two 30 day field studies in Birmingham, AL, USA were conducted to compare the response of two APSs operated with and without an inlet conditioner to that measured with FRM samplers. In field studies, the correlation of PM(10-2.5) derived from the APS and that measured with the FRM was substantially stronger with an inlet conditioner applied (r2 ranged from 0.91 to 0.99) than with no conditioner (r2 = 0.61). Laboratory experiments confirmed the ability of the heater and desiccant conditioner to remove particle-borne moisture. In field tests, water was found associated with particles across the sizing range of the APS (0.5 microm to 20 microm) when relative humidity was high in Birmingham. Certain types of inlet conditioners may substantially improve the correlation between particulate mass concentration derived from real-time particle sizers and filter-based samplers in humid conditions.  相似文献   

16.
In support of a feasibility study of reproductive and developmental health among females employed in the Monchegorsk (Russia) nickel refinery, personal exposure and biological monitoring assessments were conducted. The inhalable aerosol fraction was measured and characterised by chemical speciation and particle-size distribution measurements. Unexpected findings were that: (i), pyrometallurgical working environments had significant levels of water-soluble nickel; (ii), significant exposure to cobalt occurred for the nickel workers; (iii), particles of size corresponding to the thoracic and respirable fractions appeared to be virtually absent in most of the areas surveyed. The water-soluble fraction is judged to be primarily responsible for the observed urinary nickel and cobalt concentrations. It is concluded relative to current international occupational-exposure limits for nickel in air, and because of the high nickel concentrations observed in urine, that the Monchegorsk nickel workers are heavily exposed. The implication of this finding for follow-up epidemiological work is alluded to.  相似文献   

17.
Measurements of aerosol particles in the air of an urban area in the UK have been made. Ambient air was sampled and the particulates measured after passing through a size selective PM10 inlet. Particle mass was measured using a Tapered Element Oscillating Microbalance (TEOM). Particle number and size distributions were obtained using an Electrical Aerosol Analyser (EAA) and an Aerodynamic Particle Sizer (APS). Measurements were also made of local meteorological parameters. Fine particle number concentrations were found to show better temporal agreement, including diurnal variation, with particle mass concentrations than the coarser particle number concentrations.  相似文献   

18.
Alumina used in the production of primary aluminium contains Be which partly vaporises from the cryolite bath into the workroom atmosphere. Since Be may be toxic at lower exposure levels than previously thought, the personal exposure to Be among workers in 7 Norwegian primary smelters has been assessed. In total, 480 personal Respicon? virtual impactor full shift air samples have been collected during 2 sampling campaigns and analysed for water soluble Be, Al and Na using inductively coupled plasma optical emission spectrometry. In addition, water soluble F(-) has been measured by ion chromatography. The Be air concentrations in the inhalable, thoracic and respirable aerosol fractions have been calculated. The Be concentrations in the inhalable aerosol fraction vary between the different smelters. The highest GM concentration of Be in the inhalable fraction (122 ng m(-3), n = 30) was measured in the prebake pot room of a smelter using predominantly Jamaican alumina where also the highest individual air concentration of 270 ng m(-3) of Be was identified. The relative distribution of Be in the different aerosol fractions was fairly constant with the mean Be amount for the two sampling campaigns between 44-49% in the thoracic fraction expressed as % of the inhalable amount. Linear regression analysis shows a high correlation between water soluble Be, Al, F and Na describing an average measured chemical bulk composition of the water soluble thoracic fraction as Na(5.7)Al(3.1)F(18). Be is likely to be present as traces in this particulate matter by replacing Al atoms in the condensed fluorides and/or as a major element in a nanoparticle sized fluoride. Thus, the major amount of Be present in the work room atmosphere of Al smelter pot rooms will predominantly be present in combination with substantial amounts of water soluble Al, F and Na.  相似文献   

19.
选取燃烧型煤和原煤的典型链条炉,应用自行设计的固定源烟气颗粒物稀释采样系统,现场测试细颗粒物PM_(2.5)、PM_(10)和金属元素的排放特征。结果表明,型煤燃烧细颗粒物的排放比例高于原煤,型煤燃烧除尘器进口、出口PM_(2.5)质量比原煤燃烧分别增加715%和708%。燃烧型煤时,As和Pb在各粒径段的质量比均比原煤大。同时,由于型煤燃烧可吸入颗粒物的排放比例增加,包含或附着在烟尘上的金属元素排放比例也相应增加。  相似文献   

20.
Particulate matter suspended in the air has adverse effects onhuman health. Its level of concentration is an important parameter in evaluating the degree of hazard it poses to the atmosphere. Conventional methods used in measuring particulatematter are often filter-based, which indicates some disadvantagesbecause such a base requires labor and time. In this study, to achieve real-time measurements, a new electrical method was developed for measuring PM10 and PM2.5 concentrations. The basicprinciple is to electrically charge particles passing through thePM inlet using a corona charger and measure the currents createdby charged particles to obtain the number concentration of particulate matter. A new type inlet based on the particle cupimpactor configuration was designed and its performance was evaluated. A unipolar diffusion charger was developed and thecharger's efficiency was determined experimentally in terms ofPn, which represents the penetration through the charger,P, times the average charge number acquired by a particle,n, for different particle sizes. The correlation was constructed between the PM10 (or the PM2.5) mass concentrationsand the electrical currents due to particles, which were chargedby the diffusion charger.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号