首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

2.
Kim BH  Lee SJ  Mun SJ  Chang YS 《Chemosphere》2005,58(11):1589-1599
Many studies have been conducted that monitor and trace the sources of polychlorinated dibenzo-p-dioxin/furans (PCDD/Fs) by comparing congener patterns of environmental samples with those of possible sources. In this study, we measured PCDD/F concentrations and compared congener patterns of samples of various media found in and around an industrial waste incinerator in Korea, including stack gas, fly ash, bottom ash, ambient air, soil, pine needle, and human blood. We obtained reliable data on the relationship between the PCDD/F distributions in these sources and the environment, and thus found indicators with which to assess the impact of such sources on the surrounding environment. In addition, the difference between the levels of PCDD/Fs in the blood of short-term workers and long-term workers demonstrates that these workers are exposed to the compounds produced by the indicator.  相似文献   

3.
Unintentionally produced persistent organic pollutants (UP-POPs) including polychlorinated dibenzo-p-dioxins, and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), and polychlorinated naphthalenes (PCNs) were characterized and quantified in stack gas and fly ash from the second ventilation systems in five typical converters in five different steelmaking plants. The 2378-substituted PCDD/Fs (2378-PCDD/Fs) and dioxin-like PCB (dl-PCBs) toxic equivalents (TEQs) were 1.84–10.3 pg WHO-TEQ Nm?3 in the stack gas and 5.59–87.6 pg WHO-TEQ g?1 in the fly ash, and the PCN TEQs were 0.06–0.56 pg TEQ Nm?3 in the stack gas and 0.03–0.08 pg TEQ g?1 in the fly ash. The concentrations of UP-POPs in the present study were generally lower than those in other metallurgical processes, such as electric arc furnaces, iron ore sintering, and secondary metallurgical processes. Adding scrap metal might increase UP-POP emissions, indicating that raw material composition was a key influence on emissions. HxCDF, HpCDF, OCDF, HpCDD, and OCDD were the dominant PCDD/Fs in the stack gas and fly ash. TeCB and PeCB were dominant in the stack gas, but HxCB provided more to the total PCB concentrations in the fly ash. The lower chlorinated PCNs were dominant in all of the samples. The 2378-PCDD/F, dl-PCB, and PCN emission factors in stack gases from the steelmaking converter processes (per ton of steel produced) were 1.88–2.89, 0.14–0.76, and 229–759 μg t?1, respectively.  相似文献   

4.
Dioxin contents in fly ash from large-scale MSW incinerators in Taiwan   总被引:6,自引:0,他引:6  
In this study, fly ash samples were collected from three municipal waste incinerators (MWI) in Taiwan. These MWIs investigated are equipped with different air pollution control devices (APCDs). Preliminary results indicated that 2,3,7,8-PCDD/Fs homologue patterns of various types of fly ash were quite similar for all three MWIs. Concentrations of higher-chlorinated congeners of PCDDs and PCDFs were remarkably higher than those of lower-chlorinated congeners. In the case of MSW-A, the PCDD/PCDF ratios of ashes were found in the decreasing order for cyclone, boiler and baghouse. The PCDD/PCDF ratios in various types of fly ash of MWI-B was boiler-A < boiler-B < ESP < boiler-C. As for MSW-C, no obvious trend has been observed for PCDD/PCDF ratio. However, the ratio in boiler ash was higher than that in baghouse ash of MWI-A. The dioxin contents in fly ash would increase as the fly ash passed through APCD zones. In other words, the environmental conditions of APCD may actually cause the increase of the dioxin contents in fly ash. The trend for dioxin contents in fly ash collected from three MSW incinerators investigated was MSW-C < MSW-A < MSW-B.  相似文献   

5.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

6.
Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers' findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/ Fs, also needs to be carefully reconsidered.  相似文献   

7.
Cheng PS  Hsu MS  Ma E  Chou U  Ling YC 《Chemosphere》2003,52(9):1389-1396
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in twenty-one ambient air samples, eight soil samples and two stack gas samples, collected near or in a municipal solid waste incinerator (MSWI) in Hsinchu, Taiwan. A systematic decrease of PCDD/Fs in the ambient air from the northeastern area was observed. PCDD/Fs levels measured in the ambient air range from 0.058 to 0.127 pg-TEQ/m3. Higher PCDD/Fs levels in the ambient air were found during winter. In addition, PCDD/Fs levels measured in the soil range from 0.524 to 5.02 pg-TEQ/g d.m. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) did not provide sufficient evidence that the environmental PCDD/Fs contamination was caused by emissions from the Hsinchu MSWI. An unknown PCDD/Fs source was proposed using congener profile analysis and supported by both PCA and HCA.  相似文献   

8.
Abstract

Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers’ findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/Fs, also needs to be carefully reconsidered.  相似文献   

9.
The distribution of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), in brief dioxins, has seldom been addressed systematically in fly ash from municipal solid waste incinerators (MSWIs). This study shows the amount and fingerprint of PCDD/Fs in fly ash from four different Chinese MSWIs, that is, three mechanical grate units and one circulating fluidized bed unit. In these fly ash samples, dioxins-related parameters (international toxic equivalent quantity, total amount of PCDD/Fs, individual isomer classes, and 17 toxic 2,3,7,8-substituted congeners) all tend to increase with decreasing particle size for mechanical grate incinerators, yet only for the finest fraction for fluidized bed units. Moreover, the fluidized bed incinerator seems superior to grate incineration in controlling dioxins, yet a comparison is hampered by internal differences in the sample, for example, the fluidized bed fly ash has much lower carbon and chlorine contents. In addition, the presence of sulfur from mixing coal as supplemental fuel to the MSW may poison the catalytic steps in dioxins formation and thus suppress the formation of dioxins. With more residual carbon and chlorine in the fly ash, it is easier to form dioxins during cooling. Nevertheless, there is no apparent relation between Fe, Cu, and Zn contents and that of dioxins in fly ash.  相似文献   

10.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

11.
Municipal solid waste incinerators (MSWIs) have long been the major contributors of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to ambient air in Taiwan. After stringent MSWI emission standards were introduced in 2001, the long-term continuous monitoring of flue gas and ambient air quality became necessary to ensure the effectiveness of the related control strategies. Three MSWIs and the surrounding ambient air were investigated in the current study for PCDD/F characteristics during 2006 to 2011. The average concentrations in the flue gas ranged from 0.008?~?0.0488 ng I-TEQ/Nm3, which is much less than the emission standard in Taiwan (0.1 ng I-TEQ/Nm3) (I-TEQ is the abbreviation of International Toxic Equivalent). This led to extremely low levels in the ambient air, 0.0255 pg I-TEQ/Nm3, much less than the levels seen in most urban areas around the world. Additionally, the results obtained using the Industrial Source Complex Short-Term Dispersion Model (ISCST3) indicate that the PCDD/F contributions from the three MSWIs to the ambient air were only in the range from 0.164?~?0.723 %. Principal component analysis (PCA) showed that the PCDD/Fs in the air samples had very similar characteristics to those from mobile sources. The results thus show that stringent regulations have been an effective control strategy, especially for urban areas, such as Taipei City.  相似文献   

12.
The distribution of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), in brief dioxins, has seldom been addressed systematically in fly ash from municipal solid waste incinerators (MSWIs). This study shows the amount and fingerprint of PCDD/Fs in fly ash from four different Chinese MSWIs, that is, three mechanical grate units and one circulating fluidized bed unit. In these fly ash samples, dioxins-related parameters (international toxic equivalent quantity, total amount of PCDD/Fs, individual isomer classes, and 17 toxic 2,3,7,8-substituted congeners) all tend to increase with decreasing particle size for mechanical grate incinerators, yet only for the finest fraction for fluidized bed units. Moreover, the fluidized bed incinerator seems superior to grate incineration in controlling dioxins, yet a comparison is hampered by internal differences in the sample, for example, the fluidized bed fly ash has much lower carbon and chlorine contents. In addition, the presence of sulfur from mixing coal as supplemental fuel to the MSW may poison the catalytic steps in dioxins formation and thus suppress the formation of dioxins. With more residual carbon and chlorine in the fly ash, it is easier to form dioxins during cooling. Nevertheless, there is no apparent relation between Fe, Cu, and Zn contents and that of dioxins in fly ash.

Implications This paper is of interest because it presents the amounts and distribution of PCDD/Fs in fly ash samples from some typical waste incineration plants in China, featuring distinct incinerator types, combustion conditions, fuel composition, or residual carbon, chloride, and heavy metal contents in fly ash.  相似文献   

13.
The formation and emission of dioxins in large scale thermal processes   总被引:15,自引:0,他引:15  
Everaert K  Baeyens J 《Chemosphere》2002,46(3):439-448
The paper assesses extensive data of PCDD/F measurements on flue gas emissions from thermal processes, including, e.g. municipal solid waste incinerators (MSWIs), combustors of wood and industrial waste, coal fired powerplants and boilers, ferro and non-ferro processes. Numerous investigators have conducted laboratory experiments to assess the formation mechanisms of PCDD/F. The results, obtained from fixed-bed experiments, have been critically evaluated and indicate that de novo synthesis is the dominant mechanism in actual thermal processes where conditions that favour the precursor formation are not experienced. The analysis of PCDD/F profiles from the large scale thermal processes in general, and MSWIs in particular, supports the dominant role of the de novo synthesis, irrespective of the type of thermal process considered. The PCDF/PCDD ratio exceeds 1 and the degree of chlorination points towards the dominant presence of HpCDD and OCDD within the dioxin group, and of PeCDF, HxCDF and HpCDF within the furan group. Since real-time measurement of PCDD/F is impossible, the correlation of PCDD/F emissions with operating parameters and/or emission levels of other more easily measured pollutants could be a tool in predicting the PCDD/F formation levels. Data of Flemish MSWIs were used to statistically assess such correlations. From an evaluation of the data at a given operating temperature, misleading conclusions can be drawn. Only the effect of temperature is evident. After converting all data at a reference temperature of, e.g. 230 degrees C, PCDD/F concentrations achieve nearly constant values, irrespective of the values of other parameters, thus stressing that the major controlling parameter for the PCDD/F emission is the temperature of the ESP. The PCDD/F concentrations increase with temperature in the range up to 280 degrees C. The ESP temperature should be kept preferably between 180 degrees C and 200 degrees C, where de novo synthesis is reduced and where PCDD/Fs are increasingly adsorbed on the fly ash, in line with the standard temperature dependence of adsorption isotherms.  相似文献   

14.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

15.
Levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in both air and soil samples were measured at three different sites in Italy, in proximity to three municipal solid waste incinerators (MSWIs) to determine baseline contamination and the contributory role of incinerator emissions. At the first site, located in an agricultural, cattle-breeding, typically flattish area of the Po Valley, the dioxin concentrations had already been measured before the start-up of the new MSWI. These dioxin concentrations were then again measured after two years of continual operation of the incinerator. Despite the presence of the plant, the PCDD/Fs concentrations appear not to have been affected and were found to be in a range of 22-125 fg I-TEQ m(-3) in the air samples and 0.7-1.5 pg I-TEQ g(-1) in the soil samples. The second site is located in an industrial district of the Veneto Region, in the surroundings of an old MSWI that is not equipped with Best Available Technology (BAT) dioxin removal system. The PCDD/Fs concentrations in the air samples were between 144 and 337 fg I-TEQ m(-3). This is a typical range of values for industrial areas, while the soil samples showed contamination levels between 1.1 and 1.4 pg I-TEQ g(-1). The third site lies in the Adige Valley, near a MSWI that has been equipped with BAT for flue gas cleaning. The observed values ranged from 10 to 67 fg I-TEQ m(-3) for the air samples and 0.08-1.2 pg I-TEQ g(-1) for the soil samples. The contributory factors of the varying characteristics of the different areas together with the types of technology adopted at each MSWI plant are discussed. The PCDD/Fs levels are subsequently compared with established values from previous studies.  相似文献   

16.
Congener specific polychlorinated biphenyl (PCB) data from the stack gas of nine Korean municipal waste incinerators was used to determine characteristic congener patterns of emitted PCBs. Principal component analysis revealed three classes of incinerators according to their pattern of PCB congener emissions: those resembling the background sampling material; those producing large quantities of a few tetra-chlorinated congeners; those producing large proportions of mono (MO-) and non-ortho (NO-) congeners relative to di-ortho (DO-) levels. Also, correlations between individual PCB congeners and polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) were discovered for several NO-PCBs and tetra and penta chlorinated PCDFs. Full PCB congener data is presented along with operating conditions for each incinerator.  相似文献   

17.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

18.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

19.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

20.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号