共查询到20条相似文献,搜索用时 23 毫秒
1.
James L. Repace 《Environment international》1982,8(1-6)
As national trends accelerate towards the reduction of ventilation and infiltration rates in buildings, coupled with an increased use of synthetic chemicals in the indoor environment, a new phenomenon has arisen: the “sick building” syndrome. Traditional approaches to environmental health developed for the outdoor air, or for the industrial occupational setting, are inadequate to deal with this problem. It is argued that a comprehensive approach to the problem of indoor air pollution is necessary to protect public health. 相似文献
2.
Indoor air pollution and inter-room pollutant transport due to unvented kerosene-fired space heaters
《Environment international》1987,13(2):159-166
Two kerosene-fired space heaters, one white-flame convective and one blue-flame radiant, were operated in the master bedroom and living room of an unoccupied house (elevation: 1800 m) under several simulated use conditions. Tests were conducted in the master bedroom with the bedroom door and bedroom window open and closed. The heaters were operated until an 8 °C temperature rise was achieved in the room. Increases in bedroom concentrations of CO, CO2, NO, NO2, and O2 are reported. The increases in CO2 levels ranged from 2440 to 5440 mL/m3 (ppm) while the increases in NO2 levels ranged from 0.12 to 0.60 mL/m3 (ppm). The NO2 emission rate from the convective heater was reduced at the high altitude location as compared with previous emission rate measurements conducted near sea level with the same heater. In addition, inter-room pollutant transport rates are reported for bedroom tests conducted with the window closed. While inter-room pollutant transport rates were less than 10 m3 with the bedroom door closed (opening area less than 100 cm2), they ranged from 16 m3/h to 53 m3/h with the bedroom door open 2.5 cm (opening = 520 cm2), and ranged from 190 to 3400 m3/h with the door fully open (opening area = 15,000 cm2). Continuous emission rate data are reported for tests conducted with the heater in the living room. 相似文献
3.
Lars Mlhave 《Environment international》1982,8(1-6)
The emission of organic gases and vapours of solvent type from 42 commonly used building materials was measured under standard atmospheric conditions. An average of 22 compounds was found in the air around each building material, and the total concentration of gases and vapours was from 0.01 to 1410 mg/m3. The average arithmetic emission rate was 9.5 mg/m2 h, and 52 different compounds were identified. A mathematical model was established for the indoor air concentrations of pollutants originating from building materials. The model was tested on three model rooms constructed from the materials investigated. The calculated total air concentrations of gases and vapours in the three rooms ranged from 1.6 to 23.6 mg/m3, and the number of compounds in the air from 23 to 32. These concentrations and number of compounds did not differ from those found in actual rooms similar in size and construction to the model rooms. The risks of health effects due to the compounds identified from the building materials were investigated, and criteria for future air quality standards are discussed. It is concluded that the possibility of negative health effects cannot be neglected, especially not for the more sensitive minority of the general population. 相似文献
4.
大气污染具有明显的跨界特性,跨区域联防联治机制是大气污染治理的重要手段。欧洲跨界大气污染治理具有完整的治理体系和丰富的实践经验,取得了显著成就,充分借鉴和吸收欧洲跨界大气污染治理的经验,对提高中国大气污染治理的科学性和有效性、推动解决大气污染治理难题具有重要意义。本文深入分析了欧洲跨界大气污染治理的背景、制度演化、治理体系和政策措施,结果发现,欧洲跨界大气污染治理机制是以EMEP为基础、以CLRTAP为核心、八项议定书为补充的不断扩展治理领域和政策边界的动态过程,其治理政策的制定表现出明显的阶段性特征。从科学化定量体系和制度化保障体系两个维度总结了欧洲跨界大气污染治理的主要措施,结合中国实际,对中国跨界大气污染治理提出了政策建议:(1)建立健全大气治理立法及配套执行体系,并严格落实问责;(2)尽快建立和完善跨界大气污染监测评估系统;(3)科学划分大气污染治理区域,成立跨区域组织领导机构;(4)加快研究制定符合国情的跨区域生态补偿机制。 相似文献
5.
Bickerstaff K 《Environment international》2004,30(6):827-840
This paper reviews recent work in the field of risk perception research, taking its examples primarily from work relating to air pollution issues. The paper opens with a brief discussion of the psychological literature on risk perception, in order to set out the key insights, criticisms and more recent developments associated with such approaches, before turning to the findings of recent socio-cultural analyses of perceptions of air pollution. This account, which considers how social and cultural factors influence the way in which people interpret and make sense of risk, draws linkages with psychological risk perception research, revealing that over the last decade there has been a pronounced degree of convergence between the conclusions being reached across these two (historically disparate) fields of research. The paper concludes by evaluating the relevance of risk perception research for the science and policy of risk assessment and management. 相似文献
6.
In a 30-m3 test chamber the air pollutants caused by man were measured. Variables were the number of persons and the rate of air change. During 2-h test sessions the temperature, relative humidity, carbon dioxide, and intensity of odors were measured. The relationship between the perceived odor intensities and the concentrations of carbon dioxide-independent of the number of persons and the air change rate—was observed. At air change rates of 12–15 m3/person/h, the carbon dioxide concentration was not higher than 0.15% and the odor intensity was evaluated only as a “slight annoyance.” Higher ventilation rates are necessary if smoking and increased physical activities are done in the rooms. 相似文献
7.
B. Brunekreef H.A. Smit K. Biersteker J.S.M. Boleij E. Lebret 《Environment international》1982,8(1-6)
Most houses in the Netherlands are equipped with gas-fired heaters and cooking appliances,since large amounts of natural gas are available within the country since the mid-1960's. Carbon monoxide poisoning due to coal fires has virtually ceased to exist when coal-fired heaters were replaced by gas heaters. However, such poisonings still occur, although to a lesser extent, due to the use of instantaneous water heaters (geisers) that are gas fired. An investigation was carried out to establish the CO production potential of geisers under normal conditions of use. The study involved 254 houses; the results indicated that 17% of the geisers produced a CO level of more than 50 μL/L in the kitchens where they were located, after 15 min of operation. Presence of a flue, burner type, and maintenance system proved to be the main controlling factors. 相似文献
8.
To study respiratory health effects of long-term exposure to ambient air pollutant mixture, we observed 7058 school children 5-16 years of age living in the four Chinese cities of Lanzhou, Chongqing, Wuhan, and Guangzhou. These children were enrolled from elementary schools located in eight districts, one urban district and one suburban district in each of the above cities. Ambient levels of PM(2.5), PM(10-2.5), total suspended particles (TSP), SO(2), and NO(x) were measured in these districts from 1993 to 1996. Based on a cluster analysis of arithmetic mean concentrations of PM(2.5), PM(10-2.5), (TSP-PM(10)), SO(2), and NO(x), we classified these children into four ordinal categories of exposure to ambient air pollutant mixtures. We tested for exposure-response relationships using logistic regression models, controlling for relevant covariates. We observed monotonic, positive relationships of exposure to the pollutant mixture with prevalence rates of cough with phlegm and wheeze. Other outcomes were not associated with the exposure in a monotonic exposure-response pattern. Even so, odds ratios for cough, phlegm, bronchitis, and asthma in the higher exposure district clusters were all higher than in the lowest exposure district cluster. We found evidence that exposure to the pollutant mixtures had adverse effects on children living in the four Chinese cities. 相似文献
9.
The paper deals with bacterial and fungal populations and other pollutants in the indoors of slums, middle class, and upper class dwellings. Both allergenic and nonallergenic organisms have been observed to be higher in slums than in other dwellings. Further, females were more susceptible to various kinds of allergies than males. 相似文献
10.
Zhang Ming Sun Ruifeng Wang Wenwen 《Environment, Development and Sustainability》2021,23(9):12814-12827
Environment, Development and Sustainability - Air pollution treatment has become the priority in environmental management for Chinese government. However, environmental problems are closely related... 相似文献
11.
Particulate air pollution in Lanzhou China 总被引:4,自引:0,他引:4
Concentrations of total suspended particles (TSP) and PM(10) in Lanzhou China have been kept high for the past two decades. Data collected during the intensive observational period from October 1999 to April 2001 show high TSP and PM(10) concentrations. Starting from November, the PM(10) pollution intensifies, and reaches mid to high alert level of air pollution, continues until April next year, and is at low alert level in the summer. In the winter and spring, the TSP concentration is 2-10 times higher than the third-level criterion of air quality (severe pollution). Effects of intrinsic factors (sources of pollution) and remote preconditions (propagation of dust storms) for severe PM(10) and TSP pollution in Lanzhou are analyzed. 相似文献
12.
Samuel C. Morris 《Environment international》1981,5(2):69-72
In industrial hygiene and health physics the goal has been to protect the health of the individual. Therefore monitoring the exposure people actually receive has been the principal concern. In regulating public exposures to air pollution, the focus has been much different. Recently, use of personal monitors and alternative means of estimating actual exposures has expanded rapidly. The role of personal monitors in epidemiology, exposure studies, and in supplementing the existing fixed station monitoring network for establishing trends and for regulatory purposes is discussed. The implications for air quality standards in recent findings of personal and indoor exposures is considered. New developments that are needed, and those that are not needed, are outlined. 相似文献
13.
This paper attempts to explain regional differences in fertility rates in the standard metropolitan statistical areas of the United States through socioeconomic factors and air pollution. An important feature of this study is that it uses the most recent data pertaining to a homogeneous sample of observations within a country rather than using data for different countries. Statistical results suggest that given other factors, fertility and the level of air pollution have an inverse relationship. This quantitative effect is statistically significant but the absolute impact is rather low. Our results also suggest that an increase in the level of income, relative education of females, temperature, and the availability of physicians would in the long run reduce fertility rates in the urban areas of the United States. 相似文献
14.
The use of coefficients, derived from cross-sectional mortality studies, for air pollution risk assessment is quite controversial. In this study, the major limitations of cross-sectional studies are reviewed. The consistency of results from the major recent cross-sectional studies is examined, and the sensitivity of results to model specification is analyzed. Finally, the implications for risk assessment of our inquiries are discussed. 相似文献
15.
Wayne R. Ott 《Environment international》1982,7(3):179-196
In recent years, considerable attention has focused on the concept of “human exposure” to environmental pollutants, but different investigators seem to have developed different definitions of this concept and used different approaches for estimating it. This paper reviews a number of “exposure” studies in a single environmental medium—air pollution—to see how others have defined this concept in the literature. Many previous investigators unfortunately calculate “exposures” by relying on data from fixed air monitoring stations, and they assume that people are located in the same place, usually their residential address, throughout a 24-h period. However, a second body of literature shows that fixed air monitoring stations do not necessarily reflect human exposures, because concentrations observed indoors—in homes, offices, factories, and motor vehicles—differ from those observed at fixed stations, and people usually spend considerable time in these locations. In an effort to standardize the nomenclature dealing with exposures, a definition is proposed in which the pollutant must come into contact with the physical boundary of the person. Then, exposure of person i to pollutant concentration c is viewed as two events occurring jointly: person i is present at a particular location, and concentration c is present at the same location. Mathematical definitions for “integrated exposure,” “average exposure,” and “standardized exposure” with various averaging periods also are introduced. Finally, two different yet compatible research approaches are suggested for determining human exposures to air pollution. 相似文献
16.
Naihua Duan 《Environment international》1982,8(1-6)
Four models for human exposure to air pollution are discussed and compared. The simple microenvironment monitoring model measures pollutant concentrations at fixed locations, regarded as proxies for similar locations or microenvironments. Since this model does not require pollutant measurements on the individual level, it is easy to implement. However, the model can only be used to estimate the average exposure in a population, and it does not provide any estimate of the variability and distribution of individual exposures. The replicated microenvironment monitoring model provides some estimates of the variability and distribution. However, because of the possible discrepancy between the microenvironment concentration distribution and the individual concentration distribution, some adjustment might be necessary. Integrated personal monitoring allows direct estimation of the average exposure as well as the variability and distribution of individual exposures. Coupled with the appropriate time budget data, a regression analysis can be applied to estimate the contribution from each microenvironment type. However, possible collinearity problems might result in low precision in those estimates. Moreover, it might be difficult to adjust for a possible Hawthorne effect. Continuous personal monitoring has the advantage of recording exposure in each microenvironment type separately, allowing direct estimation of the average exposure as well as the variability and distribution of exposures in each microenvironment type. Moreover, it can also be conducted in conjunction with a two-stage sampling scheme, using information from a large data base on activity patterns, thereby making more efficient use of the monitoring data. It is also easier to adjust for a possible Hawthorne effect in this design. 相似文献
17.
空气污染对居民公共健康的影响,引起了人们高度的关注。但大多数学者研究从样本的独立性出发且不考虑内生性问题,忽视区域之间空间相关性,所得结论和政策建议需谨慎对待。为了弥补上述不足,本文基于Grossman中国宏观健康生产函数,选取2001—2014年中国广东省珠江三角洲9个城市作为样本,选择以PM_(10)和PM_(2.5)作为空气污染的代理指标,在充分考虑空间效应和严格假设检验的基础上选择合适的空间计量经济学模型,对此进行实证研究。主要研究结果显示:空气污染对居民的公共健康带来了负面影响,即PM_(10)和PM_(2.5)每增加1%,导致哮喘疾病和内科门诊等疾病人数不断上升,且影响都比较大,尤其是对哮喘疾病的影响分别为0.2236%和0.2272%。经济增长对公共健康均有显著的促进作用,影响最大;其它财政医疗支出、卫生技术人员和人口密度等要素对居民公共健康的影响较小。由于空气污染的负外部性,研究还发现,区域之间空气污染的"溢出效应"对领域居民公共健康存在显著的影响,说明忽视空间自相关性的存在,会使得空气污染对公众健康的估计产生偏差。从长期看,空气污染对本地居民公共健康的直接效应都显著为正,PM_(2.5)间接效应显著为负,但PM_(10)间接效应并不显著。因此,各级政府除了在源头上治理污染物的排放,提高公共健康水平外,还应该打破各自为阵的行政垄断,应该作为一个整体,实现跨区域环保合作,共同治理和制定公共卫生政策等。这对区域之间协同减排和保护居民公共健康具有重要的理论和现实意义。 相似文献
18.
19.
Ambient air pollution and children's lung function in China 总被引:1,自引:0,他引:1
ObjectiveTo describe the correlations between ambient air pollutants (TSP, SO2, NOx) and the level of children's lung function (FVC, FEV1, MMEF) in China.MethodsWe collected the research articles on ambient air pollution and children's lung function published from 1985 to 2006 and selected 11 articles finally according to the following criteria: (1) Children between the age of 7 and 15 as objects; (2) Local air quality monitoring results were reported; (3) Strict quality control was taken when testing children's lung function; (4) The results were expressed by the average of measured value. Then we analyzed the correlation relationship between the level of ambient air pollutants and children's lung function and compared the effects of ambient air pollutants on children's lung function of boy and girl.ResultsThe selected articles included the results of 7 cities in China. Among them, the results of 6 cities' studies revealed that the levels of children's lung function were significantly lower in the areas with heavy ambient air pollution than those in the areas with light ambient air pollution. According to the articles, the average levels of TSP were at the range of 0.084 mg/m3–0.835 mg/m3, SO2 were 0.013 mg/m3–0.929 mg/m3, NOx were 0.044 mg/m3–0.229 mg/m3. Correlation analysis showed significant negative correlation between the levels of TSP and SO2 and children's FVC and FEV1, as well as the levels of NOx and children's MMEF. The correlation coefficient was ? 0.797 (t = ? 4.384, P = 0.001) between TSP and FVC, ? 0.693 (t = ? 4.190, P < 0.001) between Ln (SO2) and FVC, ? 0.886 (t = ? 5.392, P = 0.001) and ? 0.685 (t = ? 4.101, P = 0.001) between FEV1 and TSP and Ln (SO2), and ? 0.973 (t = ? 5.993, P = 0.027) between NOxNOx and MMEF, respectively. The results also suggested that the decreases of lung function for girl with the increasing of ambient air pollution were significantly greater for boy.ConclusionThe levels of ambient air TSP and SO2 correlated with the damage of the big airway function of children, while NOxNOx affected the small airway function chiefly. Furthermore, lung function of girl was more susceptible to ambient air pollutants than boy. 相似文献
20.
This article intends to shed a light on air quality in Turkey and compare air pollutant emissions on a national scale with that of the European countries. In order to estimate the quantities of Turkish emissions in the past and their future predictions, a national emission inventory was prepared with respect to five major pollutants consisting of particulate matter(PM), SOx, NOx, non-methane volatile organic compounds, and CO with 5-year intervals between 1985 and 2005. The results suggest that Turkey is a rather large emission source at the European scale, although emission indicators on unit area and per capita were shown to be somewhat smaller in magnitude. Levels of air pollution in some of the big cities in Turkey were also evaluated from available national monitoring data. These evaluations for the urban air qualities covered SO2 and PM parameters between 1986 and 1996, and results were compared with the present Turkish air quality limits, their probable revisions, WHO (Europe) guidelines and related EC directives. Results showed that the air quality limits were not met, especially during the winter periods in Turkish cities. Urban air pollutants characterizing the air in Turkish cities other than SO2 and PM, however, could not have been evaluated as these pollutants were not systematically monitored in these cities. 相似文献