共查询到20条相似文献,搜索用时 0 毫秒
1.
Determination of commonly used polar herbicides in agricultural drainage waters in Australia by HPLC 总被引:1,自引:0,他引:1
The present study describes the application of different extraction techniques for the preconcentration of ten commonly found acidic and non-acidic polar herbicides (2,4-D, atrazine, bensulfuron-methyl, clomazone, dicamba, diuron, MCPA, metolachlor, simazine and triclopyr) in the aqueous environment. Liquid-liquid extraction (LLE) with dichloromethane, solid-phase extraction (SPE) using Oasis HLB cartridges or SBD-XC Empore disks were compared for extraction efficiency of these herbicides in different matrices, especially water samples from contaminated agricultural drainage water containing high concentrations of particulate matter. Herbicides were separated and quantified by high performance liquid chromatography (HPLC) with an ultraviolet detector. SPE using SDB-XC Empore disks was applied to determine target herbicides in the Murrumbidgee Irrigation Area (NSW, Australia) during a two-week survey from October 2005 to November 2005. The daily aqueous concentrations of herbicides from 24-h composite samples detected at two sites increased after run-off from a storm event and were in the range of: 0.1-17.8 microg l(-1), < 0.1-0.9 microg l(-1) and 0.2-17.8 microg l(-1) at site 1; < 0.1-3.5 microg l(-1), < 0.1-0.2 microg l(-1) and < 0.2-3.2 microg l(-1) at site 2 for simazine, atrazine and diuron, respectively. 相似文献
2.
Solid-phase microextraction coupled with gas chromatography-mass spectrometry (SPME-GC-MS) was used to analyze two triazine (atrazine and simazine) and three chloroacetamide herbicides (acetochlor, alachlor, and metolachlor) in water samples from a midwest US agricultural drainage ditch for two growing seasons. The effects of salt concentration, sample volume, extraction time, and injection time on extraction efficiency using a 100-mum polydimethylsiloxane-coated fiber were investigated. By optimizing these parameters, ditch water detection limits of 0.5 microgL(-1) simazine and 0.25 microgL(-1) atrazine, acetochlor, alachlor, and metolachlor were achieved. The optimum salt concentration was found to be 83% NaCl, while sample volume (10 or 20 mL) negligibly affected analyte peak areas. The optimum extraction time was 40 min, and the optimum injection time was 15 min. Results indicated that atrazine levels in the ditch water exceeded the US maximum contaminant level for drinking water 12% of the time, and atrazine was the most frequently detected among studied analytes. 相似文献
3.
《环境污染与防治》2015,(9)
建立了水样中毒死蜱及其主要代谢产物3,5,6-三氯吡啶醇(TCP)的固相萃取—气相色谱质谱检测法,即采用固相萃取对水样中的毒死蜱及其代谢产物TCP进行富集,浓缩后经双(三甲基硅烷基)三氯乙酰胺(BSTFA)衍生TCP,采用气相色谱质谱进行测定。同时,采用外标法对毒死蜱和TCP进行定量。结果表明,该方法的线性范围为20~1 000μg/L,毒死蜱和TCP的检出限分别为0.375、0.100μg/L;环境水样中的毒死蜱和TCP平均加标回收率分别为89.12%~93.44%和87.37%~90.75%,相对标准偏差(RSD)为2.79%~6.64%和1.22%~5.48%。 相似文献
4.
Stephen W. D. Jenkins Carolyn J. Koester Vincent Y. Taguchi David T. Wang Jean-Paul F. P. Palmentier Kim P. Hong 《Environmental science and pollution research international》1995,2(4):207-210
A simple, rapid method for the extraction of N-nitrosodimethylamine (NDMA) from drinking and surface waters was developed using Ambersorb 572. Development of an alternative method to classical liquid-liquid extraction techniques was necessary to handle the workload presented by implementation of a provincial guideline of 9 ppt for drinking water and a regulatory level of 200 ppt for effluents. A granular adsorbent, Ambersorb 572, was used to extract the NDMA from the water in the sample bottle. The NDMA was extracted from the Ambersorb 572 with dichloromethane in the autosampler vial. Method characteristics include a precision of 4 % for replicate analyses, an accuracy of 6 % at 10 ppt and a detection limit of 1.0 ppt NDMA in water. Comparative data between the Ambersorb 572 method and liquid-liquid extraction showed excellent agreement (average difference of 12 %). With the Ambersorb 572 method, dichloromethane use has been reduced by a factor of 1,000 and productivity has been increased by a factor of 3–4. Monitoring of a drinking water supply showed rapidly changing concentrations of NDMA from day to day. 相似文献
5.
6.
Santilio A Stefanelli P Girolimetti S Dommarco R 《Journal of environmental science and health. Part. B》2011,46(6):535-543
A simple and rapid method has been studied for the determination of acidic herbicides (2,4-D, Dichlorprop, Dichlorprop-p, Fluazifop, Fluroxypyr, MCPA, Mecoprop and Mecoprop-p) on cereals (rye). The method involves an alkaline hydrolysis with sodium hydroxide in order to release covalently bound compounds, prior to QuEChERS extraction, followed by neutralization and analysis via liquid chromatography-double mass spectrometry LC/MS/MS. The performance of the method either with or without alkaline hydrolysis was studied in terms of recovery rates and limit of quantification (LOQ). In either case, recoveries were determined at four spiking levels (0.02 mg/kg, 0.05 mg/kg, 0.1 mg/kg and 0.5 mg/kg) with 5 replicates for each level. Mean recoveries ranged from 90 to 120 %, whereas relative standard deviations (RSD %) proved to be less than 20 %. Quantitative analysis was carried out by the internal standard (Nicarbazin) and the LC/MS/MS analysis was performed in electrospray ionisation (ESI) negative mode using a Zorbax XCB Eclipse column. The developed method was applied to the analysis of several cereals commercially available like as rye flour, oat meal, oat flakes and dehusked oat. Residue levels were found below the limit of quantification (LOQ) of the method. The method has been tested in EU Proficiency Tests for cereals with good results. 相似文献
7.
固相萃取毛细管气相色谱法分析水中有机磷农药残留 总被引:10,自引:0,他引:10
探索了采用固相萃取对样品进行提取富集,以及配备氮磷检测器的毛细管气相色谱(CGC)法分析水中有机磷农药痕量残留的方法。结果表明:敌敌畏、内吸磷、乐果、甲基对硫磷、马拉硫磷和对硫磷等6种农药在20min内有较好的分离;3个不同浓度的标准添加,其回收率范围为52.1%~93.7%,最低检出限范围为1.11~5.21ng/L;同时利用该方法分析太湖梅梁湾水源地和长江沿岸水厂取水口水质,6种有机磷农药均有一定程度检出,但仍未超出集中水源地供水标准。 相似文献
8.
The goal of this study was to develop a robust method of analyzing surface water samples for S-triazine herbicides, chloroacetanilide herbicides, and their transformation products (TPs) using solid-phase extraction (SPE) followed by liquid chromatograph-mass spectrometry (LC-MS) with electrospray ionization (ESI) by in-source collision-induced dissociation (ISCID) capability of an orthogonal electrospray ionization probe on a single quadrupole LC-MS system. The method developed here met the goals of the study and yielded estimated method detection limits (EMDLs) averaging 0.3 ± 0.1 ng L(-1) for S-triazines and their TPs and 0.7 ± 0.4 ng L(-1) for chloroacetanilides and TPs. Spiked filtered river water yielded SPE recoveries ranging from 94.2 % ± 4.8 % for S-triazines and TPs after eliminating three compounds with less that 65 % recovery from analysis and 95.9 % ± 19 % for chloroacetanilides and their TPs. The method was field-tested with filtered water samples collected from four sites over a four-month period. Detectible values of S-triazines and TPs ranged from 0.3 to 1540 ng L(-1) with a mean of 79.3 and a median of 19.4 ng L(-1). Detectible values for chloroacetanilides and TPs ranged from 0.31 to 3780 ng L(-1) with a mean of 252 and a median of 25.6 ng L(-1). An additional goal was to determine if the method was useful for microbial degradation studies using native bacterial communities. The bacteria transformed atrazine (2-chloro-4-ethylamino-6-isopropylamino-S-triazine) solely into 2-hydroxy atrazine (2-hydroxy-4-ethylamino-6-isopropylamino-S-triazine) with concentrations of 78.4, 63.3 and 32.5 ng L(-1) after 12 days of incubation compared with 6.3 and 7.1 ng L(-1) for control dark and control sunlight respectively. 相似文献
9.
Discovery of the fuel additive methyl tert-butyl ether (MTBE) in groundwater, surface water, and stormwater has prompted studies of its sources, transport and fate. More limited data, however, is available on the extent of contamination of coastal waters, as well as the persistence of MTBE in the marine environment. We apply here the combination of solid phase microextraction and gas chromatography-mass spectrometry to the detection of sub-to-low microgram/l concentrations of MTBE in seawater samples. Analysis of samples collected at the Marina del Rey harbor, a shallow recreational harbor near Los Angeles, CA, show MTBE contamination in the low microgram/l level. MTBE measurements were made at different depths, from the surface to the bottom, at five sites within the harbor during months showing no measurable precipitation. The highest concentration of MTBE (18 microgram/l) was found at the boat launching ramp, and the lowest (0.2 microgram/l) near the harbor entrance, approximately 2.3 km from the ramp. The levels of MTBE measured, as well as their variation over the study period, are fully consistent with recreational boating as the primary source of contamination. No evidence for MTBE contamination from the adjacent stormwater control channel was noted. 相似文献
10.
Queiroz ME Silva SM Carvalho D Lanças FM 《Journal of environmental science and health. Part. B》2001,36(5):517-527
A solid-phase microextraction (SPME) procedure has been developed to extract eight organophosphorus pesticides (OPs) in water and the method was compared with a conventional solid phase extraction (SPE) technique. The extracted OPs were analyzed by gas chromatography using thermionic specific detection. Both extraction methods presented linear calibration at least over the concentration range investigated (100 to 1000 ng x mL(-1) for SPE and 1 to 100 ng x mL(-1) for SPME). SPME method presented higher sensitivity than SPE. The quantitation limits were between 0.1 to 1.0 ng x mL(-1) for SPME depending upon the analyte, and 100 ng x mL(-1) for SPE. The precision, as measured by the standard deviations (RSD), were in the range 3.6% to 5.8% for SPME and 2.4% to 9.2% for SPE. Along with the feature of being a solvent - free sampling technique, SPME offers additional benefits due to its high sensitivity, simplicity, and small size sample required (typically: SPE - 500 mL, SPME - 5 mL). 相似文献
11.
固相萃取-毛细管气相色谱法测定蔬菜、土壤和水中的毒死蜱残留量 总被引:4,自引:0,他引:4
采用固相萃取技术提取蔬菜、土壤和水体中毒死蜱,建立了蔬菜、土壤和水体中毒死蜱的固相萃取-气相色谱测定方法,并与传统方法进行了比较。添加浓度为0.1、1、10 mg·L-1,两种方法的水样平均回收率分别在93.7%~102.7%和96.2%~100.2%,变异系数分别在2.2%~7.7%和3.3%~5.1%;土壤平均回收率分别在91.3%~100.7%和92.0%~104.8%,变异系数分别在1.4%~7.0%和0.3%~5.2%;蔬菜平均回收率分别在89.4%~101.4%和92.5%~101.8%,变异系数分别在5.2%~7.1%和3.1%~6.0%。试验结果表明,固相萃取法与传统方法的回收率和变异系数相当,但前者更加省时、省力和省溶剂。 相似文献
12.
Monitoring the sonochemical degradation of phthalate esters in water using solid-phase microextraction 总被引:8,自引:0,他引:8
The sonochemical degradation of aqueous solutions containing low concentrations of six phthalate esters at an ultrasonic frequency of 80 kHz has been investigated. Ultrasonic treatment was found capable of removing the four higher molecular mass phthalates (di-n-butyl phthalate, butylbenzyl phthalate, di-(2-ethylhexyl) phthalate and di-n-octyl phthalate) within 30-60 min of irradiation. The rest (dimethyl phthalate and diethyl phthalate) were more recalcitrant and nearly complete removal could be achieved only after prolonged irradiation times. The relative reactivity of phthalates was explained in terms of their hydrophobicity. Experiments were carried out at an overall initial phthalate concentration of 240 microg l(-1), values of electric power of 75 and 150 W, temperatures of 21 and 50 degrees C and in the presence of NaCl to study the effect of various operating conditions on degradation. Solid-phase microextraction (SPME) coupled with GC-MS proved to be a powerful analytical tool to monitor the sonochemical degradation of phthalate esters at low microg l(-1) concentration levels, minimising the risk of secondary contamination during sample preparation, a major parameter to consider during phthalates analysis. The advantages as well as disadvantages of using SPME are also highlighted. 相似文献
13.
A high-performance liquid chromatographic method was developed to analyse selected endocrine disrupting chemicals in water by using automated on-line solid-phase extraction with a fluorescence detector. The excitation and emission wavelengths of the fluorescence detector were 230 nm and 290 nm, respectively. The selected endocrine disrupting chemicals include hormone steroids such as estradiol (E2), estriol (E3), ethynylestradiol (EE2), and ethynylestradiol 3-methyl ether (MeEE2) as well as nonylphenols (NP), octylphenols (OP), POE(1-2) nonyl phenol (NPE) and bisphenol A (BP). Three types of on-line cartridges (C18, PLRP-s and PRP-1) were tested to pre-concentrate the endocrine disruptors in deionised water. It was found that the recoveries of these chemicals at 1 microg/L were close to 100% except for 4-octyl phenol and 4-n-nonyl phenol, which had recoveries of about 40% to 80%. The two polymer cartridges (PLRP-s and PRP-1) gave higher recoveries than the C18 cartridges. The addition of methanol at 5% to 10% in water significantly improved the recovery of 4-octyl phenol and 4-n-nonyl phenol. The addition of methanol also led to an improvement in the recovery with C18 cartridges. With the addition of methanol in water samples, these three types of cartridges gave similar recoveries for the chemicals. The detection limits of this method ranged from 20 ng/L to 50 ng/L. A river water sample spiked with these chemicals was analysed using the above method and we found no interference with the peaks of the selected endocrine disrupting chemicals. The recoveries for these chemicals were more than 92% except for 4-NP with a recovery of 61%. This relatively simple method is useful for laboratory studies on the environmental fate of these endocrine disrupting chemicals in water. 相似文献
14.
Heinz Singer 《Environmental pollution (Barking, Essex : 1987)》2010,158(10):3054-3064
This study focused on the input of hydrophilic biocides into the aquatic environment and on the efficiency of their removal in conventional wastewater treatment by a mass flux analysis. A fully automated method consisting of on-line solid phase extraction coupled to LC-ESI-MS/MS was developed and validated for the simultaneous trace determination of different biocidal compounds (1,2-benzisothiazoline-3-one (BIT), 3-Iodo-2-propynylbutyl-carbamate (IPBC), irgarol 1051 and 2-N-octyl-4-isothiazolinone (octhilinone, OIT), carbendazim, diazinon, diuron, isoproturon, mecoprop, terbutryn and terbutylazine) and pharmaceuticals (diclofenac and sulfamethoxazole) in wastewater and surface water. In the tertiary effluent, the highest average concentrations were determined for mecoprop (1010 ng/L) which was at comparable levels as the pharmaceuticals diclofenac (690 ng/L) and sulfamethoxazole (140 ng/L) but 1-2 orders of magnitude higher than the other biocidal compounds. Average eliminations for all compounds were usually below 50%. During rain events, increased residual amounts of biocidal contaminants are discharged to receiving surface waters. 相似文献
15.
对土壤中8种有机氯农药(α-HCH、β-HCH、γ-HCH、δ-HCH、p,p’-DDE、p,p’-DDD、o,p’-DDT、p,p’-DDT)进行了分析,使用加速溶剂萃取(ASE)仪对土壤样品中的目标组分进行萃取、凝胶渗透色谱(GPC)仪对萃取液净化、双塔双柱同时进样分析,采用双电子捕获检测器(ECD)同时定性定量测定。结果表明,该方法检测效果较好,8种有机氯农药的回收率在81.3%~88.6%,相对标准偏差为3.9%~5.7%,检出限为0.18~0.37μg/kg。与传统的方法相比,该方法操作简便、重复性好,定性定量更准确。 相似文献
16.
17.
Farag Malhat Hany Badawy Dalia Barakat Ayman Saber 《Journal of environmental science and health. Part. B》2013,48(5):331-335
A method for determination of etoxazole residues in apples, strawberries and green beans was developed and validated. The analyte was extracted with acetonitrile from foodstuff and a charcoal-celite cartridge was used for clean-up of raw extracts. Reversed phase high performance liquid chromatography with photodiode array detector (HPLC-DAD) was used for the determination and quantification of etoxazole residues in the studied samples. The calibration graphs of etoxazole in a solvent or three blank matrixes were linear within the tested intervals 0.01–2 mg L?1, with correlation coefficient of determination >0.999. The combined solid phase extraction (SPE) clean-up and the chromatographic method steps were sensitive and reliable for simultaneous determination of etoxazole residues in the studied samples. The average recoveries of etoxazole in the tested foodstuffs were between 93.4 to 102% at spiking levels of 0.01, 0.10, and 0.50 mg kg?1, with relative standard deviations ranging from 2.8 to 4.7%, in agreement with directives for method validation in residue analyses. The limit of detection (LOD) of the HPLC-DAD system was 100 pg. The limit of quantification of the entire method was 0.01 mg kg?1. 相似文献
18.
Youssef Filali-Meknassi Muriel Auriol Craig D Adams Rao Y Surampalli 《Water environment research》2007,79(6):687-696
In this study, the occurrence of trace amounts of natural and synthetic steroid estrogens in the aquatic environment was studied using liquid chromatography coupled with electrospray mass spectrometry, following solid-phase extraction (SPE). The SPE was performed with C18 and NH2 cartridges. The first objective was to develop a reliable method for analyzing steroid estrogens (resulting from human and animal excretions) in different matrices. The method developed was then applied to quantify the occurrence of natural and synthetic hormones (estrone [E1], 17beta-estradiol [betaE2], 17alpha-estradiol [alphaE2], estriol [E3], and 17alpha-ethinylestradiol [EE2]) in environmental samples in surface water and wastewater treatment plant (WWTP) influent and effluent. In the WWTP influents, betaE2, alphaE2, and E3 were identified as ranging up to 72.6 ng/L in WWTP influent and to 16 ng/L in WWTP effluent. Analysis o f surface wa ter sampled upstream from the WWTP revealed the presence of all five estrogens, at levels up to 19.8 ng/L. These concentrations of estrogens pose an issue for large and small communities, because they are higher than the recommended guidelines for estrogen-active compounds and because a lot of communities use surface water as drinking-water sources. 相似文献
19.
Claudio A. Alister Manuel A. Araya Marcelo Kogan 《Journal of environmental science and health. Part. B》2013,48(1):62-68
This investigation was performed to determine the effect of physicochemical soil properties on penoxsulam, molinate, bentazon, and MCPA adsorption–desorption processes. Four soils from Melozal (35° 43′ S; 71° 41′ W), Parral (36° 08′ S; 71° 52′ W), San Carlos (36° 24′ S; 71° 57′ W), and Panimavida (35° 44′ S; 71° 24′ W) were utilized. Herbicide adsorption reached equilibrium after 4 h in all soils. The Freundlich L-type isotherm described the adsorption process, which showed a high affinity between herbicides and sorption sites mainly because of hydrophobic and H-bonds interaction. Penoxsulam showed the highest adsorption coefficients (4.23 ± 0.72 to 10.69 ± 1.58 mL g?1) and were related to soil pH. Molinate showed Kd values between 1.72 ± 0.01 and 2.3 ± 0.01 mL g?1and were related to soil pH and organic matter, specifically to the amount of humic substances. Bentazon had a high relationship with pH and humic substances and its Kd values were the lowest, ranging from 0.11 ± 0.01 to 0.42 ± 0.01 mL g?1. MCPA Kd ranged from 0.14 ± 0.02 to 2.72 ± 0.01 mL g?1, however its adsorption was related to humic acids and clay content. According to these results, the soil factors that could explain the sorption process of the studied herbicides under paddy rice soil conditions, were principally humic substances and soil pH. Considering the sorption variability observed in this study and the potential risk for groundwater contamination, it is necessary to develop weed rice management strategies that limit use of herbicides that exhibit low soil adsorption in areas with predisposing conditions to soil leaching. 相似文献
20.
This investigation was performed to determine the effect of physicochemical soil properties on penoxsulam, molinate, bentazon, and MCPA adsorption-desorption processes. Four soils from Melozal (35° 43' S; 71° 41' W), Parral (36° 08' S; 71° 52' W), San Carlos (36° 24' S; 71° 57' W), and Panimavida (35° 44' S; 71° 24' W) were utilized. Herbicide adsorption reached equilibrium after 4 h in all soils. The Freundlich L-type isotherm described the adsorption process, which showed a high affinity between herbicides and sorption sites mainly because of hydrophobic and H-bonds interaction. Penoxsulam showed the highest adsorption coefficients (4.23 ± 0.72 to 10.69 ± 1.58 mL g?1) and were related to soil pH. Molinate showed K(d) values between 1.72 ± 0.01 and 2.3 ± 0.01 mL g?1 and were related to soil pH and organic matter, specifically to the amount of humic substances. Bentazon had a high relationship with pH and humic substances and its K(d) values were the lowest, ranging from 0.11 ± 0.01 to 0.42 ± 0.01 mL g?1. MCPA K(d) ranged from 0.14 ± 0.02 to 2.72 ± 0.01 mL g?1, however its adsorption was related to humic acids and clay content. According to these results, the soil factors that could explain the sorption process of the studied herbicides under paddy rice soil conditions, were principally humic substances and soil pH. Considering the sorption variability observed in this study and the potential risk for groundwater contamination, it is necessary to develop weed rice management strategies that limit use of herbicides that exhibit low soil adsorption in areas with predisposing conditions to soil leaching. 相似文献