首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The relationship between different features of lichen communities in Quercus robur canopies and environmental variables, including concentrations of NO2 and NH3 was investigated. NO2 concentration was the most significant variable, it was positively correlated with the proportion of lichen cover comprising nitrophytes and negatively correlated with total lichen cover. None of the lichen community features were correlated with NH3 concentrations, which were relatively low across the site. Since nitrophytes and nitrophobes are likely to react in opposite directions to nitrogenous compounds, total lichen cover is not a suitable indicator for these pollutants. It is, therefore, suggested that the proportion of lichen cover comprising nitrophytes may be a suitable simple indicator of air quality, particularly in locations where the pollution climate is dominated by oxides of nitrogen.  相似文献   

2.
Biotreatment of various ratios of H2S and NH3 gas mixtures was studied using the biofilters, packed with co-immobilized cells (Arthrobacter oxydans CH8 for NH3 and Pseudomonas putida CH11 for H2S). Extensive tests to determine removal characteristics, removal efficiency, removal kinetics, and pressure drops of the biofilters were performed. To estimate the largest allowable inlet concentration, a prediction model was also employed. Greater than 95% and 90% removal efficiencies were observed for NH3 and H2S, respectively, irrespective of the ratios of H2S and NH3 gas mixtures. The results showed that H2S removal of the biofilter was significantly affected by high inlet concentrations of H2S and NH3. As high H2S concentration was an inhibitory substrate for the growth of heterotrophic sulfur-oxidizing bacteria, the activity of H2S oxidation was thus inhibited. In the case of high NH3 concentration, the poor H2S removal efficiency might be attributed to the acidification of the biofilter. The phenomenon was caused by acidic metabolite accumulation of NH3. Through kinetic analysis, the presence of NH3 did not hinder the NH3 removal, but a high H2S concentration would result in low removal efficiency. Conversely, H2S of adequate concentrations would favor the removal of incoming NH3. The results also indicated that maximum inlet concentrations (model-estimated) agreed well with the experimental values for space velocities of 50–150 h−1. Hence, the results would be used as the guideline for the design and operation of biofilters.  相似文献   

3.
A study of major atmospheric particulate sulfate species was conducted during 30 July 1980–1983 September 1980 in Sterling Forest, a rural area in Tuxedo, NY, not affected by major local sources of pollution. In situ measurements of total sulfate, sulfuric acid and ammonium sulfate ammonium bisulfate were made using Thermal Analysis-Flame Photometric Detection (TA-FPD). These measurements were compared to the total sulfate and strong acid (H+) concentration measured in simultaneously collected 12 h, treated quartz filter samples. The concentration of NH4HSO4 was inferred from the difference between the total strong acid concentration and the sulfuric acid measurements, so that total sulfate and acid concentrations could be balanced. A major sulfate pollution episode occurred during the period of 27–29 August. The concentration of H+ showed an excess above that necessary to account for the TA-FPD H2SO4 measurement, indicating the presence of NH4 HSO4. The maximum 12 h average concentrations of H2SO4, NH4HSO4 and (NH4)2SO4 were 5.18, 11.42 and 10.08 μg m−3 as SO42− respectively, and were measured from 9:15 to 21:15 on 28 August. The study demonstrated the usefulness of concurrent measurements of airborne particulate sulfate by filter extraction and TA-FPD to identify acidic sulfate species.  相似文献   

4.
Effects of high ammonia emissions and nitrogen deposition were investigated on lichens around a pig stockfarm (ca. 7,000 animals) in central Italy. Four sites were selected along a transect at 200, 400, 1000 and 2500 m from the stockfarm, the diversity of epiphytic lichens was measured and transplanted thalli of Xanthoria parietina and Flavoparmelia caperata exposed, together with passive NH3 (diffusion tubes) samplers. Ammonia dramatically decreased from the centre of the stockfarm to the sampled sites, where it was correlated with bark pH. Total lichen diversity was not associated with either NH3 concentrations or bark pH, but the diversity of strictly nitrophytic species was highly correlated with both parameters. Physconia grisea was the best indicator species for NH3 pollution. Total N accumulated in X. parietina and F. caperata was correlated with NH3 concentrations.  相似文献   

5.
This study characterized the seasonal concentration (C) and emission (E) patterns of odor, ammonia (NH3), and hydrogen sulfide (H2S) over the course of a whole year and their diurnal patterns in cold, warm, and mild seasons for a naturally ventilated free-stall dairy barn. It was found that seasonal odor and NH3 and H2S emissions varied greatly: from 17.2 to 84.4 odor units (OU) sec?1 AU?1 (AU: animal unit, 500 kg of animal body mass), from 0.27 to 0.92 mg sec?1 AU?1, and from 3 to 105 μg sec?1 AU?1, respectively. The overall concentrations of odor and NH3 were higher in the winter, whereas the emissions were higher in the mild and warm seasons. Diurnal variation was most significant for odor emission (OE) in the mild season when the ratio of maximum (279.2 OU sec?1 AU?1) to minimum value (60.5 OU sec?1 AU?1) was up to 4.6. The indoor air quality was also evaluated by considering not only the health effect of individual gases, but also the additive effect of NH3 and H2S. Results showed that the indoor air quality was poorest in cold seasons when NH3 C could exceed the threshold limit set out in occupational health regulation, and in fact could worsen due to the additive effect of the two gases. Further, it was suggested NH3 was a good indicator for predicting odor concentration (OC) or OE. The impact of climatic parameters on odor and gases were also examined, and it was found ventilation rate (VR) negatively affected OC and NH3 C, but positively impacted OE and NH3 E. Using 70% of the total data, a multilinear model for OE was developed as a function of VR and indoor relative humidity and was validated to be acceptable using the rest of the data.

Implications: Diurnal and seasonal variations of odor, NH3, and H2S concentrations and emissions were monitored for a naturally ventilated dairy barn in a cold region. The emission factors were calculated and indoor air quality was evaluated. The overall odor and NH3 concentrations were higher in winter, whereas emissions were higher in the mild and warm seasons. Diurnal variation was most significant for odor emission in the mild season, when the ratio of maximum to minimum value was up to 4.6. The results can be used to estimate odor and gas emissions from other dairy barns in Canada and other cold regions.  相似文献   

6.
采用酸性洗涤塔、生物滤塔和生物曝气池的组合工艺处理NH3、H2S恶臭混合气体,研究表明,该组合工艺对NH3和H2S有很好的去除效果,在进气流量为35 L/min,喷淋量45 L/h时,NH3进气浓度50.15~525.4 mg/m3,H2S进气浓度10.23~110.36 mg/m3时,NH3单一进气去除率稳定在99%以上,H2S单一进气去除率90%以上。混合进气后,NH3去除率几乎为100%,H2S的去除率提高至98%以上。在一定的浓度范围内,NH3和H2S之间的相互作用对两者的去除效果没有明显的影响,而且起到了相互促进降解的作用。同时,进气流量和填料层高度都会影响NH3、H2S的去除率。系统对进气容积负荷变化的缓冲能力强,在偶尔超负荷条件下运行并不能使系统崩溃,并且微生物对高负荷逐渐表现出适应性。大部分溶于水的氨由生物曝气池去除,去除率达到96.9%。  相似文献   

7.
Abstract

Simultaneous removal of NH3 and H2S was investigated using two types of biofilters—one packed with wood chips and the other with granular activated carbon (GAC). Experimental tests and measurements included analyses of removal efficiency (RE), metabolic products, and results of long-term operation (around 240 days). The REs for NH3 and H2S were 92 and 99.9%, respectively, before deactivation. After deactivation, the RE for NH3 and H2S were decreased to 30–50% and 75%, respectively. The activity of nitrifying bacteria was inhibited by high concentrations of H2S (over 200 ppm) but recovered gradually after H2S addition was ceased. However, the Thiobacillus thioparus as sulfur oxidizing bacteria did not show inhibition at the NH3 concentration under 150-ppm conditions. The deactivation of the biofilter was caused by metabolic products [elemental sulfur and (NH4)2SO4] ac-cumulating on the packing materials during the extended operation. The removal capacities for NH3 and H2S were 6.0–8.0 and 45–75 mg N, S/L/hr, respectively.  相似文献   

8.
ABSTRACT

The purpose of this research was to determine the efficiency of a polymer biocover for the abatement of H2S and NH3 emissions from an east-central Missouri swine lagoon with a total surface area of 7800 m2. The flux rate of NH3, H2S, and CH4 was monitored continuously from two adjacent, circular (d = 66 m) control and treatment plots using a nonintrusive, micrometeorological method during three independent sampling periods that ranged between 52 and 149 hr. Abatement rates were observed to undergo a temporal acclimation event in which NH3 abatement efficiency improved from 17 to 54% (p = <0.0001 to 0.0005) and H2S abatement efficiency improved from 23 to 58% (p < 0.0001) over a 3-month period. The increase in abatement efficiency for NH3 and H2S over the sampling period was correlated with the development of a stable anaerobic floc layer on the bottom surface of the biocover that reduced mass transfer of NH3 and H2S across the surface. Analysis of methanogenesis activity showed that the biocover enhanced the rate of anaerobic digestion by 25% when compared with the control. The biocover-enhanced anaerobic digestion process was shown to represent an effective mechanism to counteract the accumulation of methanogenic substrates in the biocovered lagoon.  相似文献   

9.
Abstract

Controlled bench-scale laboratory experiments were conducted to evaluate the recovery of ammonia (NH3) and hydrogen sulflde (H2S) from dynamic isolation flux chambers. H2S (80–4000 ppb) and NH3 (5000–40,000 ppb) samples were diffused through the flux chamber to simulate ground level area source emissions while measuring the inlet and outlet flux chamber concentrations simultaneously. Results showed that the recovery of H2S during a 30-min sampling time was almost complete for concentrations >2000 ppb. At the lowest concentration of 80 ppb, 92.55% of the H2S could be recovered during the given sampling period. NH3 emissions exhibited similar behavior between concentrations of 5000–40,000 ppb. Within the 30-min sampling period, 92.62% of the 5000-ppb NH3 sample could be recovered. Complete recovery was achieved for concentrations >40,000 ppb. Predictive equations were developed for gas adsorption. From these equations, the maximum difference between chamber inlet and outlet concentrations of NH3 or H2S was predicted to be 7.5% at the lowest concentration used for either gas. In the calculation of emission factors for NH3 and H2S, no adsorption correction factor is recommended for concentrations >37,500 ppb and 2100 ppb for NH3 and H2S, respectively. The reported differences in outlet and inlet concentration above these ranges are outside the full-scale sensitivity of the gas sensing equipment. The use of 46–90 m of Teflon tubing with the flux chambers has apparently no effect on gas adsorption, because recovery was completed almost instantaneously at the beginning of the tests.  相似文献   

10.
This paper presents the results of continuous measurements of trace atmospheric gases and aerosol composition made at the summit of Whiteface Mountain, New York, for 28 days in July 1982. The gas phase species NO, NOx ( = NO + NO2 + PAN), HNO3, SO2 and NH3 were measured, as well as aerosol SO42−, NO3, H+ and NH4+. Mean and median NOx concentrations were 1.1 and 1.0 ppb, respectively, with maximum and minimum values of 3.2 and 0.3 ppb. HNO3 concentrations were variable, occasionally exceeding the simultaneously measured NOx levels. Mean and median SO2 were 0.8 and 0.3 ppb, with concentrations up to 12 ppb in pollution episodes. Mean and median NH3 were both 2.2 ppb. Monthly mean SO42− was 5.3 μg m−3, with values in clean air of about 1.5 μg m−3, and in polluted air up to 80 μg m−3. Trajectory calculations indicate that episodes of high pollutant concentrations occur in air masses arriving at Whiteface from the southwest. These episodes contributed most of the SO42−, HNO3 and aerosol acidity, and about half the SO2 and NOx to which the site was exposed during the measurement period. Limited comparisons of air chemistry data with the composition of cloudwater collected during the program are also presented.  相似文献   

11.
The suitability of a set of ecophysiological parameters, to be used as early warning indicator to detect signs of a worsening environment around geothermal power plants, was tested by comparison with the diversity of epiphytic lichens, a well-established indicator of geothermal air pollution. Samples of the lichen Evernia prunastri were transplanted around a geothermal power plant at Larderello (Tuscany, Italy) and at a control site, and integrity of cell membranes, concentration of chlorophyll a, b and carotenoids, chlorophyll integrity and variations in pH of thalli were measured. The results showed that cell membrane damage, expressed by changes in electrical conductivity, could be used to detect early (exposure periods as short as 1 month) deleterious effects of geothermal air pollution.  相似文献   

12.
The biowaste fractions in municipal solid waste (MSW) are the main odor sources in landfill and cause widespread complaints from residents. The ammonia (NH3) and hydrogen sulfide (H2S) generation processes were simulated and compared between four typical biowaste fractions individually and combined in the mixed MSW. Food waste was found to be the main contributor to odor emission in mixed MSW, with H2S generation potential of 48.4 μg kg?1 and NH3 generation potential of 4742 μg kg?1. Fruit waste was another source for NH3 generation, with 3933 μg kg?1 NH3 generation potential. Meanwhile, nitrogen (N) was released in a faster way than sulfur (S) in waste, since 31% and 46% of total NH3 and H2S were generated in the first 90 days after disposal, with 1811 and 72 μg kg?1, and more emphasis should be placed in this initial period.

Implications:?Monitoring of odor generation from biowastes in MSW on a laboratory scale showed that food waste is the main source for NH3 and H2S generation, whereas waste fruit is another main contributor for NH3 released. Generally, N was released in a faster way than S from mixed-waste landfilling.  相似文献   

13.
Odor pollution is a big environmental problem caused by large-scale livestock production in China, and developing a practical way to reduce these odors is pressing. In this study, a combination of 0.2–1.0 U/mL lignin peroxidase (LiP) and one of three peroxides (H2O2, CaO2, 2Na3CO3·3H2O2) was examined for its efficiency in reducing the release of eight chemicals (propionic acid, isobutyric acid, isocaproic acid, isovaleric acid, phenol, p-cresol, indole, and skatole), NH3, H2S, and odor intensity from pig manure. The results showed an approximately 90% reduction in p-cresol, 40–60% reduction in odor intensity, 16.5–40% reduction in indolic compounds, and 25–40% reduction in volatile fatty acids. Being the electron acceptors of LiP, 2Na3CO3·3H2O2 and CaO2 performed better than H2O2 in reducing the concentration of eight chemicals, NH3, H2S, and odor intensity from pig manure. The effect of deodorization can last for up to 72 hr.

Implications: In China, one of the major environmental problems caused by confined feeding is odor pollution, which brings a major threat to the sustainability, profitability, and growth of the livestock industry. To couple the LiP with the electron acceptors, a low–cost, simple, and feasible method for odor removal was established in this study. Based on the study results, a practical treatment method was provided for odor pollution and supply the farm operators a more flexible time to dispose treated manure.  相似文献   


14.
The evolution of H2S and SO2 from hot blast furnace slags by reaction with H2O has been found to be dependent upon the presence of O2 or H2 in the reaction zone as well as on the temperature. H2 has been found to produce a small increase in H2S and a small decrease in SO2 emission, while O2 has been found to produce a very great inhibiting effect on H2S emission and only a small increase in SO2 emission. The total emission of sulfur bearing gases is much less when H2O + air is blown at the slag than when H2O + Ar is blown at the slag, particularly at 1200°C and above. These effects may be useful in attempts to design systems for slag quenching which will produce less pollution.  相似文献   

15.
Abstract

Sewage sludge and yard waste compost were used as biofilter materials and tested with respect to their capacity for removing ammonia from air at different water contents. Ammonia removal was measured in biofilters containing compost wetted to different moisture contents ranging from air dry to field capacity (maximum water holding capacity). Filters were operated for 15 days and subsequently analyzed for NH3/NH4 +, NO2 -, and NO3 -. The measured nitrogen species concentration profiles inside the filters were used to calculate ammonia removal rates. The results showed that ammonia removal is strongly dependent on the water content in the filter material. At gravimetric water contents below 0.25 g H2O g solids-1 for the yard waste compost and 0.5 g H2O g solids-1 ammonia removal rates were very low but increased rapidly above these values. The sewage sludge compost filters yielded more than twice the ammonia removal rate observed for yard waste compost likely because of a high initial concentration of nitrifying bacteria originating from the wastewater treatment process and a high air-water interphase surface area that facilitates effective ammonia dissolution and transport to the biofilm.  相似文献   

16.
The MAP3S precipitation chemistry network base of event chemistry data includes nine sites widely distributed over the northeastern quadrant of the United States. Eight or these sites now have a period of record of at least 5 years. Four species (total sulfur, NO3, H+ and NH+4) account for the bulk of ionic equivalents at seven inland sites; Ca2+ is nearly as important as NH+4 at several of the inland sites, and sea salt species are major components at the two coastal sites. Average pH values (from arithmetic mean H+) range from 4.03 to 4.24 over the network. Time trend analyses for the period for sulfur and H+ show a consistent decrease, but the decrease is quite small and has low statistical significance; NO3; and NH+4 show similar though less consistent trends. Significant seasonal trends (summer maximum, winter minimum) are found at most sites for sulfur and NH+4; NO3 has a much weaker seasonal trend except at the coastal sites. Species pair correlations are strong among the four major ions, with the exception of correlations involving H+ at sites where crustal species are more important (Illinois, Ohio). Correlations can qualitatively be explained by common sources (crustal, sea-salt, anthropogenic), polluted vs nonpolluted events, and strong seasonal trends.  相似文献   

17.
The depsidone fumarprotocetraric acid as well as the depsides perlatolic and thamnolic acids are lichen secondary metabolites. Their first dissociation constants (pKa1) in methanol were determined to be 2.7 for perlatolic acid and 2.8 for fumarprotocetraric and thamnolic acids by UV spectroscopy. Lower pKa1 values are, so far, not known from lichen substances. Several lichens producing at least one of these compounds are known for their outstanding tolerance to acidic air pollution. This is demonstrated by evaluating published pH preferences for central European lichens. The low pKa1 values suggest that strong dissociation of the studied lichen substances is a prerequisite for the occurrence of lichens with these compounds on very acidic substrata, as protonated lichen substances of different chemical groups, but not their conjugated bases, are known to shuttle protons into the cytoplasm and thereby apparently damage lichens.  相似文献   

18.
Abstract

Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 µm in diameter, and total suspended particulate from swine and poultry production buildings in the United States.

This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with ≥10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.  相似文献   

19.
Topographic and meteorological conditions make the Columbia River Gorge (CRG) an 'exhaust pipe' for air pollutants generated by the Portland-Vancouver metropolis and Columbia Basin. We sampled fog, bulk precipitation, throughfall, airborne particulates, lichen thalli, and nitrophytic lichen distribution. Throughfall N and S deposition were high, 11.5-25.4 and 3.4-6.7 kg ha(-1) over 4.5 months at all 9 and 4/9 sites, respectively. Deposition and lichen thallus N were highest at eastern- and western-most sites, implicating both agricultural and urban sources. Fog and precipitation pH were frequently as low as 3.7-5.0. Peak NO(x), NH(3), and SO(2) concentrations in the eastern CRG were low, suggesting enhanced N and S inputs were largely from particulate deposition. Lichens indicating nitrogen-enriched environments were abundant and lichen N and S concentrations were 2x higher in the CRG than surrounding national forests. The atmospheric deposition levels detected likely threaten Gorge ecosystems and cultural resources.  相似文献   

20.
The rate of production of SO2 from H2S was measured in a series of experiments in a broad, ground-level plume from geothermal vents in New Zealand. The mean rate constant for the reaction was 3.5 ± 1.3 × 10−3 min−1 which produced a mean lifetime for H2S oxidation of 500 ± 240 min. It is likely that the major oxidant of H2S in the atmosphere is the OH radical, but it is also necessary to consider additional unknown mechanisms to fully explain the results.  相似文献   