首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
为了研究输煤皮带转载点密闭罩内流场对吸尘效果的影响,采用Fluent软件对某转载点密闭罩内气固两相流动情况进行了数值模拟。通过气流分布和煤尘浓度分布的分析,发现溜槽转折处较大的气流偏转会增加煤尘起尘量和导致局部煤尘积聚,吸尘罩的开口角度对吸尘效果也有较大影响。为了疏导气流并加强吸尘效果,提出了溜槽转折处和吸尘罩的结构优化设计方案。研究表明,改进后气流分布更加均匀,吸尘效果有所提高,从而为转载点密闭罩的优化设计提供了参考。  相似文献   

2.
采用碱化、醚化法制备了以废纸为原料的煤尘抑制剂,借助FTIR、SEM、TG-DTA及XRF等手段对合成物进行了表征,并将其用于抑制煤尘进行性能测试。结果表明,羧甲基纤维素的取代度为0.69;选用羧甲基纤维素含量为0.5g/mL的煤尘抑制剂进行应用实验,效果最佳。9 h内,喷洒含有羧甲基纤维素的煤尘抑制剂的煤样表面已经结壳,抗七级风,抑尘率在130 h都可保持在99%以上。在较高温燃烧条件下,煤尘抑制剂以H2O和CO2的形式失去,不会产生有害物质。  相似文献   

3.
A monitoring system for coal panicle dispersion at coal storage yards is necessary to meet environmental standards for the operation of coal fired power plants. We have developed a system having three functions as follows:
  • 1.(1) To measure coal particle concentrations at the first connecting part of belt conveyors.
  • 2.(2) To predict occurrence of coal particle dispersion during stacking.
  • 3.(3) To moisten the coal at the second connecting part of belt conveyors when coal particle dispersion occurs.
The generation of coal dispersion is determined by whether or not the hygroscopic moisture is greater than the critical hygroscopic moisture value for each coal type. Coal particle concentrations are measured using dust meters. In this report, the dust meter readings were related to emission rate of coal particle and dustiness index of coarse dust defined by ASTM D547-41 in order to predict occurrence of coal particle dispersion using dust meters.The adaptability of the system to real coal handling facilities was examined by a model which consisted of belt conveyors, a stacker, connecting parts and the monitoring system. As a result of these experiments, it was demonstrated that coal particle dispersion can be suppressed by means of wetting coal in response to dust meter readings.  相似文献   

4.
Environmental Science and Pollution Research - To control the dust pollution caused by open-pit coal mining and reduce or avoid the secondary hazards of existing dust suppressants to the...  相似文献   

5.

Aiming at the problems of complex environment and serious dust pollution in large open-pit coal yards, a dust suppression gel with a dual network structure was prepared by modifying the soluble starch and sodium alginate with iron ions. The changes of functional groups, thermal stability, and morphology structure before and after the reaction were analyzed by FTIR, TG-DSC, and SEM, and the formation mechanism of the dual network was revealed by XPS. Furthermore, the water absorption and water retention experiments proved that the dual network structure is more conducive to water retention than the single-layer network. According to molecular dynamics simulations and contact angle experiments, gel and adsorbed water molecules can approach coal dust molecules on their own to contact, wet, and combine with coal dust. The adhesion test proved that the dust suppression gel with iron ions had better adhesion to dust. The anti-freezing test shows that the dust suppression gel has good anti-freezing performance. The antifreeze test shows that the dust suppression gel still has excellent freeze–thaw resistance at the test temperature of??-20℃. The mechanical property test shows that the dust suppressant gel can prevent the product from being damaged by external force. The acid and alkali resistance experiments showed that the acid and alkali resistance of the gel was improved under the condition of iron ion modification, and the flying of coal powder was effectively prevented. This research provides a new theoretical idea for coal dust control in complex environment.

  相似文献   

6.
输煤皮带负压吸尘设备及系统的改进研究   总被引:1,自引:0,他引:1  
分析了输煤皮带负压吸尘设备及系统目前存在的主要问题 ,详细介绍了对该系统的改进措施和实际情况。  相似文献   

7.
Richards Bay, on the northern KwaZulu-Natal coast, is the largest coal exporting port in South Africa. The coal is stored at the Richards Bay Coal Terminal (RBCT) prior to export. Dust from coal operations is a major problem in the Richards Bay area. In this study, we tested the hypothesis that coal dust adversely affects photosynthetic performance of Avicennia marina (Forssk.) Vierh., the dominant mangrove species in the harbour. Photosynthetic performance was determined on 10 trees by measuring carbon dioxide uptake and chlorophyll fluorescence parameters at two elevation sites and on upper and lower leaf surfaces that were covered or uncovered with coal dust. Measurements were made on five clear, sunny days at saturating light (>1,000 micromol m(-2)s(-1)) and high temperature (28-30 degrees C). Coal dust significantly reduced carbon dioxide exchange of upper and lower leaf surfaces by 17-39%, the reduction being generally greater on the lower leaf surface that is covered by a dense mat of trichomes and salt glands. The reduction in carbon dioxide exchange by coal dust was higher at the high elevation site that supported isolated dwarfed trees. The chlorophyll fluorescence data indicated that leaves coated with dust exhibited significantly lower photosystem II (PS II) quantum yield, lower electron transport rate (ETR) through PSII and reduced quantum efficiency of PSII (FvFm). The chlorophyll fluorescence data supported the gas exchange measurements and are consistent with reduced photosynthetic performance of leaves coated with coal dust.  相似文献   

8.
Resuspended street dust is a source of inhalable particles in urban environments. Despite contaminated street dust being a possible health risk factor for local population, little is known about the contribution of atmospheric dust emissions and other factors to the content of toxic metals in street dust. The impact of smelting, traffic, and power plants on metal contaminates in street dust is the focus of street dust sampling at 46 locations in the Witbank area (Republic of South Africa). This area is characterized by numerous open-pit coal mines in the Karoo coal basin, which provides a cheap source of energy to numerous metallurgical smelters and ironworks and supplies coal to the coal-fired power plants located nearby. Street dust was collected on asphalt or concrete surfaces with hard plastic brushes, avoiding collecting of possible sand, soil, or plant particles. Chemical analysis was done on the <0.125 mm fraction using inductively coupled plasma mass spectrometry subsequent to total digestion. Exceptionally high concentrations of metals were detected with concentrations of Fe reaching 17.7 %, Cr 4.3 %, Mn 2 %, Ni 366 mg/kg, and V 4,410 mg/kg. Factor analysis indicates three sources for the pollution. Road traffic which contributes to the high concentrations of Cu, Pb, Sb, and Sn, with the highest impacts detected in the town of Witbank. The second source is associated with the metal smelting industry, contributing to Fe, Co, Mn, and V emissions. The highest factor scores were observed around four metallurgical smelter operations, located in the Ferrobank, Highveld, and Clewer industrial areas. Impact of vanadium smelter to street dust composition could still be detected some 20 km away from the sources. Exceptionally high concentrations of Cr were observed in four samples collected next to the Ferrobank industrial area, despite Cr not being loaded in factor 2. The last source of the pollution is most probably fly ash associated with the coal-fired power plants and fly ash dumps. Elements which are associated with this source are Al, Sr, and Li. This factor is abundant in the coal mining part of the study area.  相似文献   

9.
The accumulation by oysters of polycyclic aromatic hydrocarbons (PAH) from coal dust entering the estuarine environment has been postulated in the vicinity of coal transfer operations. Oysters Crassostrea virginica were exposed to coal dust plus 15 day leachate at concentrations of 10 mg litre(-1) and 1 mg litre(-1) coal dust for 28 days in a flow-through test system. Potential effects of the exposures were measured by comparing the uptake of PAH and the growth of the exposed animals versus control groups. Oysters sampled at 7, 14 and 28 days did not exhibit an increase in PAH body burden over control animals provided the guts were first purged of particulates. Even at the high test concentrations (10 mg litre(-1)), no effect of the exposure on shell growth was observed.  相似文献   

10.
针对粉煤灰排放产生二次污染问题,经过分析比较,选用了科学的加湿排放工作原理,设计了用于粉煤灰排放的新型灰料加湿卸灰机。  相似文献   

11.
针对粉煤灰排放产生二次污染问题,经过分析比较,选用了科学的加湿排放工作原理,设计了用于粉煤灰排放的新型灰料加湿卸灰机。  相似文献   

12.
The size distribution and chemical components of a fine fraction (<2.5 μm) of road dust collected at urban sites in Korea (Gwangju) and Mongolia (Ulaanbaatar) where distinct urban characteristics exist were measured. A clear bimodal size distribution was observed for the resuspended fine road dust at the urban sites in Korea. The first mode peaked at 100–110 nm, and the second peak was observed at 435–570 nm. Ultrafine mode (~30 nm) was found for the fine road dust at the Mongolia site, which was significantly affected by residential coal/biomass burning. The contribution of the water-soluble ions to the fine road dust was higher at the sites in Mongolia (15.8–16.8%) than at those in Korea (1.2–4.8%). Sulfate and chloride were the most dominant ionic species for the fine road dust in Mongolia. As (arsenic) was also much higher for the Mongolian road dust than the others. The sulfate, chloride, and As mainly come from coal burning activity, suggesting that coal and biomass combustion in Mongolia during the heating season should affect the size and chemical components of the fine road dust. Cu (copper) and Zn (zinc), carbonaceous particles (organic carbon [OC] and elemental carbon [EC]) increased at sites in Korea, suggesting that the fine road dust at these sites was significantly affected by the high volume of traffic (engine emission and brake/tire wear). Our results suggest that chemical profiles for road dust specific to certain sites should be applied to more accurately apportion road dust source contributing to the ambient particulate matter.

Implications: Size and chemical characteristics of fine road dust at sites having distinct urban characteristics were examined. Residential coal and biomass burning and traffic affected physiochemical properties of the fine road dust. Different road dust profiles at different sites should be needed to determine the ambient PM2.5 sources more accurately.  相似文献   


13.
输煤系统粉尘污染治理技术   总被引:2,自引:0,他引:2  
概述了输煤系统粉尘污染治理的现状,分析了采用常规方法治理输煤系统粉尘污染存在的缺点及除尘效率低的原因。介绍了近几年研究开发的2种输煤系统粉尘污染治理新技术的除尘机理、适用范围、系统组成及主要特点。  相似文献   

14.
微细水雾除尘技术的实验研究   总被引:7,自引:1,他引:7  
分析了煤矿并下呼吸性粉尘防治技术现状,并对水的超声雾化技术进行了实验研究,应用回归分析建立了超声雾化性能的数学模型。在分析微细水雾捕尘机理及捕尘水雾凝并沉降技术的基础上,设计了一集微细水雾捕尘-凝聚、凝并降尘-惯性沉降分离为一体的含尘气流净化系统,并对该系统的除尘效率进行了实验研究,建立了相应的数学模型。  相似文献   

15.
应用化学质量平衡模型解析烟台市污染源的排放贡献率   总被引:8,自引:0,他引:8  
根据烟台地区污染排放特点,应用化学质量平衡模型(CMB8)进行污染源解析分析,得出每个污染源对于受体地区颗粒物体样本的排放贡献率。最终的模型结果显示,建筑尘和居民烯煤锅炉排放,海洋尘和冶炼厂排放对于大气环境污染也有一定的贡献,以上分析可以为城市污染源治理提供一定的依据。  相似文献   

16.
Diagnostic ratios and multivariate analysis were utilized to apportion polycyclic aromatic hydrocarbon (PAH) sources for road runoff, road dust, rain and canopy throughfall based on samples collected in an urban area of Beijing, China. Three sampling sites representing vehicle lane, bicycle lane and branch road were selected. For road runoff and road dust, vehicular emission and coal combustion were identified as major sources, and the source contributions varied among the sampling sites. For rain, three principal components were apportioned representing coal/oil combustion (54%), vehicular emission (34%) and coking (12%). For canopy throughfall, vehicular emission (56%), coal combustion (30%) and oil combustion (14%) were identified as major sources. Overall, the PAH's source for road runoff mainly reflected that for road dust. Despite site-specific sources, the findings at the study area provided a general picture of PAHs sources for the road runoff system in urban area of Beijing.  相似文献   

17.
焦炉装煤和推焦烟气合用 1套收集系统。除尘废水经吸附后用于熄焦 ,熄焦水经吸附后用于湿式除尘 ,实现循环零排放。煤气洗涤水循环为废水中氨氮的处理提供了可行的方法  相似文献   

18.
本文论述了我国燃煤工业锅炉排放SO2对大气污染的状况及发展趋势,以及应用工业固硫型煤控制燃煤工业锅炉对大气的污染。燃煤工业锅炉燃烧工业固硫型煤时,可明显地降低SO2和烟尘的排放量,并节约煤炭。在当前及今后相当长的时期内,推广和发展工业固硫型煤,是防治燃煤工业锅炉大气SO2污染的一条投资少、见效快、简便易行的实用措施,其经济效益及环境效益相当可观。  相似文献   

19.
Very high concentration of suspended particulate matter (SPM) is observed at traffic junctions in India. Factor analysis-multiple regression (FA-MR), a receptor modelling technique has been used for quantitative apportionment of the sources contributing to the SPM at two traffic junctions (Sakinaka and Gandhinagar) in Mumbai, India. Varimax rotated factor analysis identified (qualitative) five possible sources; road dust, vehicular emissions, marine aerosols, metal industries and coal combustion. A quantitative estimation by FA-MR model indicated that road dust contributed to 41%, vehicular emissions to 15%, marine aerosols to 15%, metal industries to 6% and coal combustion to 6% of the SPM observed at Sakinaka traffic junction. The corresponding figures for Gandhinagar traffic junction are 33%, 18%, 15%, 8% and 11%, respectively. Due to limitation in source marker elements analysed about 16% of the remaining SPM at these two traffic junctions could not be apportioned to any possible sources by this technique. Of the observed lead in the SPM, FA-MR apportioned 62% to vehicular emissions, 17% to road dust, 11% to metal industries, 7% to coal combustion and 3% to marine aerosols at Gandhinagar traffic junction and about a similar apportionment for lead in SPM at Sakinaka traffic junction.  相似文献   

20.
The use of windbreaks to reduce wind-blown coal dust at the POSCO Kwang-Yang open storage yards was studied using wind simulations on a scale model of the yards. Based on these simulation results, a full-scale wind fence was constructed on two sides of the yard. Here, we present results on the wind behavior both for the real yard and for the simulation results that guided its construction. Wind-tunnel simulations were used to study the effect of a porous wind fence of porosity ε=30% on the surface pressure and shear stress on coal piles using a 1/1200 model of the POSCO Kwang-Yang open storage yards. In addition, the shelter effects found in the model system were verified in field measurements on the full-scale system. The storage yard model was fully embedded in an atmospheric surface boundary layer over open terrain. The fence and coal pile model had the same height (12.2 mm) and Reynolds number (Re=1.6×104, based on the model height). The mean and fluctuating surface-pressure distributions on the coal piles, which are closely related to the dust emission from the surface, were measured for several directions of the oncoming wind. The wind directions pertinent to the study were determined by statistical analysis of seasonal wind data over the storage yard. A porous wind fence of porosity ε=30% was found to be useful for reducing the wind speed without the formation of a recirculating bubble behind the fence. In addition, the fence caught the wind-borne particles when it was located behind the coal piles. The wind fence reduced the pressure fluctuations and surface shear stress on the coal piles to less than half of the levels observed in the no fence case. To verify the effectiveness of the porous wind fence installed around the Kwang-Yang open storage yard, the local wind speed and the concentration of suspended particles were measured directly. Full-scale porous fences installed around the Kwang-Yang open storage yard greatly decreased the turbulence intensity of the wind over the coal piles and reduced the total suspension particles by 70–80%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏